HMV Variable Motors Data and Specifications

Similar documents
PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

DuraForce HMV / HMR / HMF / HMA Closed and Open Loop Hydraulic Motor

Eaton Closed and Open Loop Hydraulic Motor DuraForce HMV / HMR / HMF / HMA

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Gold Cup Hydrostatic Transmission

3/3-Way-Proportional Valve

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

Technical Principles of Valves

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

AXIAL PISTON PUMPS VARIABLE DISPLACEMENT

Axial Piston Variable Motor A6VM

Section 7.1. Wheel Drive Circuit - General System

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Axial Piston Variable Motor AA6VM (A6VM)

Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Flow direction is reversed by tilting the swash plate to the opposite side of the neutral or zero displacement position.

Sectional Directional Control Valve RSQ 240

Variable Displacement Motor AA6VM (A6VM)

New Generation Hydraulics. Series 02

Flow sharing control block in mono block / sandwich plate design M6-22

LogSplitterPlans.Com

LUDV control block in mono block/sandwich plate design M7-20

Axial Piston Variable Motor A6VM

Flow sharing control block in sandwich plate design M7-25

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 40

Axial Piston Variable Double Pump A8VO

Definitions of Technical Terms

Axial piston variable motor A6VM series 65. Americas. RE-A Edition: Replaces:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

AXIAL PISTON PUMPS AND MOTORS

Axial piston variable motor A6VM series 71. Americas. RE-A Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Flow sharing control block in mono block / sandwich plate design M6-15

Axial Piston Variable Motor A6VM (US-Version)

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

M7X / M7V Series. Swash Plate Type Axial Piston Motor. Precision Machinery Company

Axial Piston Variable Motor A6VM

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

3/2-way Solenoid Valve for pneumatics

2.4 HEAVY DUTY SERIES

Axial piston variable motor A6VM series 71

Directional Control Valve CV550

Fixed Displacement Motor A2FM

Fixed Displacement Plug-In Motor A2FE

Hydrokraft Piston Motors Technical Catalog MVX

2.3 MEDIUM HEAVY DUTY SERIES

TUTORIAL QUESTIONS FOR COURSE TEP 4195

Variable Displacement Plug-In Motor A6VE

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

HMF/A/V/R-02. Hydraulic motors for closed and open loop operation

Series PAVC Variable Volume, Piston Pumps

Axial piston variable pump A4VG Series 40

Radial piston motor for wheel drives MCR-F

PUmP REfEREncE guide Bulletin E

HMF/A/V/R-02. Hydraulic motors for closed and open loop operation

Fixed Displacement Motor AA2FM (A2FM)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

AXIAL PISTON MOTORS MF S E R I E S 2 0 C L O S E D C I R C U I T

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial piston variable pump A4VG Series 40. Americas. RE-A Edition: Replaces:

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Hydraulic Motor Series V12 Variable Displacement

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

NUMBER: S.M. REF.: Refer to 2.5 ENGINE: 60 DATE: January 2007

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Input, Control and Processing elements

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Hydraulic Pump Series VP1 Variable Displacement

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Axial piston variable pump A10V(S)O Series 31

US 8,570,835 B in a forward or aft position causing a vibratory source assembly 175 to vibrate back and forth propagating sound waves out and a

HPR-02. REGULATING PUMPS for open loop

PREHEATER BYPASS SYSTEMS

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Variable Displacement Pump A4VG for closed circuits

Axial piston variable pump A4VG Series 40

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Radial Piston Motor (Multi-Stroke) MCR3

Series PVP Variable Volume Piston Pumps

Radial piston motor for track drives MCR-T

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

V33D-250 CLOSED LOOP. Tradition Quality Future

Axial Piston Variable Pump AA4VG

Axial piston variable pump A10VO Series 32

HP3V SERIES. Swash-plate Type Axial Piston Variable Displacement Pump

COOPERATIVE PATENT CLASSIFICATION

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

CENTAC Inlet and Bypass Valve Positioners

Variable Plug-in Motor A6VE

Series 20 Axial Piston Pumps. Technical Information

Variable plug-in motor A6VE Series 71

Transcription:

Data and Specifications Specifications HMR 55 HMR 75 HMR 105 HMR 135 cm 3/rev in 3/rev 55 3.36 75 4.57 105 6.40 135 8.23 Pressure Ratings Nominal 5000 PSIG Maximum 6090PSIG Peak 7250 PSIG Rated Speed 4000 3700 3300 3000 Max. Disp. Rated Speed 5000 4600 4100 3700 Min. Disp. Envelope Size L W H 9.0 8.0 9.2 9.5 8.2 9.8 10.5 8.2 9.8 11.3 10.1 10.7 Weight 75.0 71.0 73.0 125.0 HP Rating Count 107.0 161.0 205.0 241.0 1

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override Circuit Diagram E 1 14 4 3 X' qmax qmin L U 2 M1 M2 T X X L U Main ports SE Flow in at port Flow in at port EXPLNTIONS Control pressure port pressure range 8-14 bar Drain (filling, vent) ports. Connection enabling case to be filled with oil. : Direction of rotation left : Direction of rotation right Solenoid switching operations M1/M2: d.c. solenoid 12 V 12 V El. Cold power rating P 20 < 26W M1/M2 de-energized : main port side pressure-controlled M1 de-energized : main port side M2 energized : pressure-controlled M1 energized : acting as fixed displacement motor HMF... - 02 (qmax operation) 2

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override The variable displacement motor HMV 02 is a swash-plate axial piston motor for the closed circuit. The motor is equipped with a proportional hydraulic displacement control and a pressure override (regulator). s an additional installation the motor has: - electric maximum displacement override - electric brake pressure shut-off - purging system Functioning of infinitely variable displacement In this control system, the motor operates at maximum displacement. The motor is control pressure dependent, with an infinitely adjustable displacement between a maximum and a minimum setting. Servo pressure >16 bar is delivered to the control mechanism from the charge pressure (see circuit diagram) via channel E. This servo pressure is transmitted via the pilot valve (1) in the normal position to the maximum displacement piston. The second displacement piston is relieved through the pilot valve into the motor casing. When a control pressure is applied at port X, the pilot valve (1) is moving against a spring force. This provides control pressure from port E to the actuator cylinder piston for minimum displacement and releases the actuator cylinder piston for maximum displacement to the tank (assumed that the system pressure < regulation begin of pressure regulator and solenoid M1 is not energized). The pressure in the actuating cylinder is increased until the swash plate swings back, causing equilibrium to prevail between the control pressure X and the feedback spring. The pilot then has a balance position. The motor holds this position until the control pressure X changes. This feedback system permits exact actuation of all qmax and qmin intermediate positions as a function of the control pressure at port X. djustment from qmax towards qmin is proportional to the control pressure (normally 8 14 bar). 3

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override Functioning of pressure regulator In the unregulated condition, the motor operates at a displacement proportional to control pressure, which is applied at connection X (see functioning of infinitely variable displacement). Following attainment of a set pressure (regulation begin), the motor swings steplessly towards maximum displacement. The two main connections of the HMV are designated and (see circuit diagram). Depending on the position of the electrically operated 3/2 directional control valve M2, one of the channels is connected with regulator 2. The start of the feedback control is determined by the pressure setting of the regulator 2, the pressure at which the motor begins to move towards maximum displacement. s soon as the pilot in the regulator 2 is shifted against the spring force, the control pressure X is relieved through the pilot valve M1 into the motor casing (hydraulic tank). daption to the required torque is effected steplessly through the changing of the swash angle. Diagram Control behaviour of the HMV-02 EH1P operating pressure p (bar) % 100 p-re p-rb 0 100 min stroke volume q (cm?) % 100 p-ae p-ab 0 control pressure X p (bar) % 4

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override Functioning of electric displacement override For a variety of applications (deliberate switching off the high-pressure influence in specific drive operations) it is necessary that the regulating motor can also be set below start of regulating control to maximum displacement. For this purpose the valve (2) is switched electrically with the solenoid M1. Functioning of electric brake pressure shut-off The electric brake pressure shut-off prevents that the back pressure in braking mode of the closed loop acts on the regulator. The solenoid M2 is operated by selection of the forward or reverse direction of travel. Depending on whether the solenoid M2 is energized or de-energized, the high pressure can only pass to the regulator (2) from one high-pressure side or. If pressure is reversed in the braking operation, the increasing brake pressure cannot affect the regulator and the motor remains in qmin. Example: Connection is the admission side The oil flow in this channel flows to the hydraulic motor. If the pressure is increased above begin of regulation set in the regulator (2) by increasing the tractive resistance in, then the motor is regulating. During braking the direction of flow and direction of rotation are maintained but the higher pressure now occurs in the return side. This, however, has no effect on the regulator. The hydraulic motor remains in the qmin position or returns to this position (exception, electric qmax operation actuated). It brakes at the torque resulting from qmin, which in vehicles corresponds to a lightly braked coasting behaviour. 5

Electric rake Pressure Shutoff Electric Maximum Displacement Override Linde purging system The hydraulic motor is equipped with a Linde purging system. This comprises two scavenging systems: Circuit scavenging - circuit scavenging - case scavenging If temperature problems occur (e.g. in the case of high ambient temperature), the temperature in the closed circuit can be substantially reduced by the scavenging system. The shuttle valve (3) connects the low-pressure side to the discharge valve (4). The purge oil can then be cooled and fed back into the system via a make up circuit (not in motor) to cool the closed loop. Case scavenging The heat generated in the rotating group of the hydraulic motor (bearings, linkages, slide faces) can only be discharged from the motor casing through the drained-off leakage. Under certain unfavourable operating conditions, e.g. high motor speed and low operating pressure, the resulting leakage is not sufficient to dissipate the frictional heat. With the Linde purging system, a quantity of oil flows from the discharge valve (4) at about 10 l/min as a cooling scavenging oil, into the casing of the hydraulic motor and then, after having scavenged the casing, drains off together with the resultant leakage. 6

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override Functioning of the Linde purging system When high-pressure lines are without load and have only boost pressure (e.g. when the pump is in the neutral position), the two pistons of the shuttle valve (3) (Fig.1) are in the spring-centered position. Operating fluid is unable to flow to the discharge valve (4) from either the high-pressure connection or the high-pressure connection. Fig. 1 1 1 3 Outlet 4 However, if high pressure (HP) builds up on, for example the side, then this high pressure displaces the piston 1, driving the piston 1 towards the low-pressure () connection (Fig.2). The conical seat (5) on piston 1 acts as a stop, thereby simultaneously preventing high-pressure fluid from being transferred out of the spring chamber 1 towards the discharge valve (4). Fig. 2 HP Inlet 1 1 5 3 Outlet 4 7

Proportional Hydraulic Control and Pressure Override Electric rake Pressure Shutoff Electric Maximum Displacement Override asic Design of Rotating Group 2 3 1 4 5 EXPLNTIONS 1 Shaft 2 Piston assembly 3 Cylinder barrel 4 Swash plate 5 Port plate 8

Proportional Hydraulic Displacement Control Circuit Diagram L (U) F E X 1 U (L) L1 Vmin Vmax 10 valve pressure 10 bar drain rate approx. 5 l/min 10 10 bar 9 l/min EXPLNTIONS Working connections F uxiliary control signal X Control pressure connection (Control pressure range 8... 14 bar) E L U Servo pressure connection (PE = 20... 40 bar) Drain (filling, vent) ports Connection enabling case to be filled with oil. Connection F for auxiliary control signal, special cases only ( normally closed ) Flow in at port : Direction of rotation left Flow in at port : Direction of rotation right 9

Proportional Hydraulic Displacement Control In this control system, the motor operates nominally at maximum displacement. The motor is control pressure dependent, with an infinitely adjustable displacement between a maximum and minimum setting. Servo pressure (minimum 20 bar) is delivered to the displacement mechanism from the pilot circuit via the connection E. This servo pressure is transmitted, via the pilot valve (1) in the normal position, (see circuit diagram), the maximum displacement piston. The second displacement piston is relieved through the pilot valve (1) into the motor casing. When a control pressure is applied at connection X, the pilot valve (1) is displaced against a spring force so the control just opens the displacement control piston minimum displacement side to port E and connects the control piston maximum displacement side to tank. The pressure in the actuating cylinder is increased until the rocker swings back, causing equilibrium to prevail between the control pressure X and the feedback spring. The pilot then has a balance position. The motor holds this position until the control pressure X changes. This feedback system permits exact actuation of all Vmax and Vmin intermediate positions as a function of the control pressure at connection X. djustment from Vmax towards Vmin is proportional to the control pressure (normally 8 14 bar), see diagram. For special cases, an auxiliary pressure signal can be applied to the back side of the pilot valve (1) via the normally closed connection F. This pressure signal supports the force of the feedback spring. This, however, requires a plug to be located in the connecting channel (in the control stage mounting) to the casing. Diagram Motor displacement [ cm? ] Vmax Vmin 8 [bar] 14 [bar] Pilot pressure 10

Proportional Hydraulic Displacement Control Functional description Linde purging system The hydraulic motor is equipped with a Linde purging system. This comprises two scavenging systems: - circuit scavenging - case scavenging Circuit scavenging If temperature problems occur (e.g. in the case of high ambient temperature), the temperature in the closed circuit can be substantially reduced by the scavenging system. The shuttle valve (8) connects the low-pressure side to the discharge valve (9). The purge oil can then be cooled and fed back into the system via a make up circuit (not in motor) to cool the closed loop. Case scavenging The heat generated in the hydraulic motor s rotating group (bearings, linkages, slide faces) can only be discharged from the motor casing through the drained-off leakage. Under certain unfavourable operating conditions, e.g. high motor speed and low operating pressure, the resulting leakage is not sufficient to dissipate the frictional heat. With the Linde purging system, a quantity of oil flows from the discharge valve (9) at about 10 l/min, as a cooling scavenging oil, into the casing of the hydraulic motor and then, after having scavenged the casing, drains off together with the resultant leakage. 11

Proportional Hydraulic Displacement Control Functioning of the Linde purging system When high-pressure lines are without load and have only boost pressure (i.e., when the pump is in the neutral position), the two pistons of the shuttle valve (8) (Fig.1) are in the spring-centered position. Operating fluid is unable to flow to the discharge valve (9) from either the high-pressure connections ( or ). Fig. 1 1 1 8 Outlet 9 However, if high pressure (HP) builds up on, for example, the side, then this high pressure displaces the piston 1, driving the piston 1, towards the low-pressure () connection (Fig.2). The conical seat (10) on piston 1 acts as a stop, thereby simultaneously preventing high-pressure fluid from being transferred out of the spring compartment 1 towards the discharge valve (9). Fig. 2 HP Inlet 1 1 10 8 Outlet 9 12

Proportional Hydraulic Displacement Control asic Design of Rotating Group 3 4 1 2 5 EXPLNTIONS 1 Shaft 2 Swash plate 3 Working piston 4 Cylinder barrel 5 Valve plate 13

Proportional Electro Hydraulic Displacement Control Speed Sensor Circuit Diagram L E Mp 10 U L1 1 qmin qmax EXPLNTIONS Working connections SE (6000psi) Flow in at port : Direction of rotation left Flow in at port : Direction of rotation right E L U Servo pressure connection (PE = 20... 40 bar) Drain (filling, vent) ports Connection enabling case to be filled with oil. 14

Proportional Electro Hydraulic Displacement Control Speed Sensor Proportional electro- hydraulic control E1 motor with this control system normally operates at maximum displacement. The displacement is electro-hydraulically variable, i.e. infinitely adjustable between maximum and minimum setting. Servo pressure of minimum 20 bar is delivered to the control mechanism from the pilot circuit via connection port E. This servo pressure is transmitted via pilot valve (1) in its normal position to one of two control pistons, which effects a move towards max. displacement, as long as the proportional solenoid Mp stays de-energized. The second control piston is relieved to the inside of the motor housing via pilot valve (1). When a pre-selected current is applied to the proportional solenoid Mp, this generates a proportional magnetic force Fm1 on the pin, thereby pushing the pilot valve (1) against the feed back spring Fm2, causing the control edges to open channel E with p con (min) and to connect to tank with p con (max). Pressure in the actuating cylinder is increased until the swash plate swings back and estabilishes an equilibrium condition of the forces Fm1 and Fm2 of the feed back spring. The pilot then is in a balance position. The motor will hold this position until the current signal is changed. Owing to this feedback system, any intermediate positions from qmax. to qmin. can be achieved accurately by means of the current at the proportional solenoid. The current values in the diagram below are to be understood as examples. Speed sensor CEH 10/.. This hydraulic motor is equipped with an RPM sensor. This sensor provides 20 impulses per revolution. These can be handled by suitable electronics, e.g. to control or supervise rotational speed. Diagram I (m) 1460 ±6 rated voltage: 10 V 834 ±6 qmin displacement V [cm?] qmax 15

Proportional Electro Hydraulic Displacement Control Speed Sensor Linde purging system The hydraulic motor is equipped with a Linde purging system. This comprises in fact two systems: - circuit scavenging - case flushing Circuit scavenging If temperature problems occur (e.g. in the case of high ambient temperature), the temperature in the closed circuit can be substantially reduced by the scavenging system. The shuttle valve (8) connects the low-pressure side to the discharge valve (9). The purged oil can then be cooled and fed back into the system via a make up circuit (not in motor) to cool the closed loop. Case flushing The only way to get rid of the heat generated in the rotating group of the hydraulic motor (bearings, linkages, slide faces) is through the leakage spill. Under certain unfavourable operating conditions, e.g. high motor speed and low operating pressure, the resulting leakage may be insufficient to dissipate the frictional heat. With the Linde scavenging system, a quantity of oil flows from the discharge valve (9) at about 10 l/min, as a scavenge-cooling oil, into the casing of the hydraulic motor and then, after having scavenged the casing, drains off together with the resultant leakage. 16

Proportional Electro Hydraulic Displacement Control Speed Sensor Functioning of the Linde purging system When high-pressure lines are without load and have only boost pressure (e.g. when the pump is in the neutral position), the two pistons of the shuttle valve (8) (Fig.1) are in the spring-centered position. Operating fluid is unable to flow to the discharge valve (9) from the high-pressure connection nor the high-pressure connection. Fig. 1 L 1 1 8 Outlet U 9 However, if high pressure (HP) builds up on, for example, the side, then this high pressure displaces the piston 1, driving the piston 1 towards the low-pressure () connection (Fig.2). The conical seat (10) on piston 1 acts as a stop, thereby simultaneously preventing high-pressure fluid from being transferred out of the spring compartment 1 towards the discharge valve (9). Fig. 2 HP Inlet L 1 1 10 8 Outlet U 9 17

Proportional Electro Hydraulic Displacement Control Speed Sensor Functioning of the Linde purging system When high-pressure lines are without load and have only boost pressure (e.g. when the pump is in the neutral position), the two pistons of the shuttle valve (8) (Fig.1) are in the spring-centred position. Operating fluid is unable to flow to the discharge valve (9) from the high-pressure connection nor the high-pressure connection. Fig. 1 L 1 1 8 Outlet U 9 However, if high pressure (HP) builds up on, for example, the side, then this high pressure displaces the piston 1, driving the piston 1 towards the low-pressure () connection (Fig.2). The conical seat (10) on piston 1 acts as a stop, thereby simultaneously preventing high-pressure fluid from being transferred out of the spring compartment 1 towards the discharge valve (9). Fig. 2 HP Inlet L 1 1 10 8 Outlet U 9 17

Proportional Electro Hydraulic Displacement Control Speed Sensor asic Design of Rotating Group 3 4 6 7 1 2 5 EXPLNTIONS 1 Shaft 2 Swash Plate 3 Working Piston 4 Cylinder arrel 5 Valve Plate 6 Speed Sensor CEH 10/.. 7 Impulse Wheel 18