Power Distribution Blocks

Similar documents
A powerful way to manage your power distribution challenges. I Power Distribution Blocks

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

Power Distribution Blocks

Power Distribution Blocks

SERIES POWER DISTRIBUTION BLOCKS

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

USCC & USM UltraSafe TM Fuseholders

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Fuse Blocks & Holders

LFJ602003C 200A 600V Fus Block

CLASS J 600 Volt Fuse Blocks

Selection Guide. Control Circuit and Load Protection

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Compact Circuit Protector

Complete and reliable solar circuit protection

Modulostar US10 Modular fuse-holders

UltraSafe US22 Modular fuse-holders

Fused Coordination Panelboard

Compact Circuit Protector (CCP)

General Purpose US Fuses

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Industrial Control Transformers

CUBEFuse. CUBEFuse catalog numbers (amps)

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Application Note

Compact Circuit Protector (CCP)

Solar Power Product SOLUTIONS GUIDE. Comprehensive photovoltaic protection

1492-CB 1492-GH 1492-GS

Compact Circuit Protector (CCP)

Selection Guide Motor Control Device Solutions

Fuse holders and fuses

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

KLKD SERIES 10x38 FUSES

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Section Contents. Disconnect Switches

T CLASS T FUSE BLOCKS

UL 508 Non-Fusible Disconnect Switches

Fuseblocks. Voltage Ratings: Ampere Ratings: Leakage Current: Catalog/system number Torque Range System Number

Low-Peak 600V Class RK1

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Compact Circuit Protector

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

Bussmann series Quik-Spec Coordination Panelboard

Bussmann. Circuit Protection Solutions

Fused Coordination Panelboard

UL 508 Non-Fusible Disconnect Switches

PANDUCT Type NNC Halogen Free Metric Wiring Duct

Now - Up To 400A Mains!

Fuse Blocks & Holders

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

CATALOG. Ty-Duct Wiring duct

Class J modular ferrule and knifeblade fuse blocks

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

North American Power Fuses

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Control Circuit Protection

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Photovoltaic System Overcurrent Protection

Bussmann series NH catalogue. Leadership in circuit protection

Specification made simple for selective coordination in a compact size

Selection and application guide

Ferrule fuses. High Speed Fuses

Solar Combiner Solutions

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

POWR-BLOKS. POWR-GARD Blocks and Holders Datasheet. Distribution Blocks Splicer Blocks Covers. Connectors. Ampere Ratings. Description.

AC Line / Load Reactors

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Limitor -G General Purpose Fuses

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Modulostar CMS10 Modular fuse-holders

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Table of contents. 1. Overview Product ordering and information Appendix Wiring duct styles 4. 1.

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

G eneral Purpose Fuses

Subject: SPF 25A and 30A Product Update. Date: May 1, 2017

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Medium Voltage Metal-Enclosed Switches

TERMINATION ENCLOSURE OPTIONS

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

footprint of traditional fusible switches

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Flexible, Customizable Power Solutions for Mission Critical Success

Transcription:

I Finger-Safe Power Distribution Blocks Power Distribution Blocks Safety evolving Ratings: Volts: 1,2,3 1500VAC/ DC; 4,5 600VAC/DC Amps: 175 to 840A SCCR: 600V or less, 100kA with proper fuse; Over 600V, 10kA Mersen s introduce a new level of safety and ease for installing power distribution blocks. An IP20 level of finger-safe protection is achieved using s, eliminating the need for special covers or custom Plexiglas sheets to protect your panels. s (sizes 1 to 4) simply snap onto 35mm DIN rail to provide the quickest installation. Modular design also allows for multi pole applications by use of assembly pins. s provide a safe, convenient way of splicing cables, splitting primary power into a variety of secondary circuits or providing a fixed junction tap-off point. Features/Benefits: Finger-safe protection: Fully insulated block ensures touch safe isolation of live parts. Recessed termination screws and wire openings provide IP20 grade protection and qualify as fingersafe per IEC 529. Compact modularity: Single or multiple pole configurations in the most compact footprint. Allows users to build smaller or higher density panels. Snap on DIN-rail mounting: Sizes 1 to 4 feature integral DIN rail adaptors allowing for quick and easy installations on 35mm DIN rail yielding lower installed costs. Captive termination screws: Unique channel design ensures captive metric wire termination screws. Screws can never be lost. Available accessories: For multi-pole panel mounting, simply snap in pins for rigid fit. Cap plugs provide the ability to maintain touch safety on unused openings. Circuit identification markers simply snap into blocks to ID circuits. End anchors provide rigid end stops. (Continued on next page.) Contact Technical Services for instruction sheet. Approvals: UL Recognized Component Guide XCFR2, File E73571 CSA Certified: Class 6228, File 69363 IEC-947-7-1, 529, 68-2-6, CE Marked I2 ep.mersen.com

Finger-Safe PDBs Power distribution blocks I Features/Benefits (continued): Multiple wire ratings: Provide users more versatility by offering capability of using multiple conductors in #2 and 2/0 openings. AC & DC ratings: 1, 2, and 3 have been evaluated for use at 1000V (AC or DC) provided they are installed on DIN-rails only and with barriers between poles of opposite polarity of sufficient size to maintain required spacings. Catalog Numbers Catalog Number Ampere Rating Line Load Aluminum Copper Wire Range Wire Range Short Circuit Current Rating (Based on NEC (Connector (Connector Openings Per Table 310-16 rated for 90 C rated for 75 C AWG/ mm for 75 C Cu Openings AWG/ kcmil mm 2 Pole Cu/AL wire) Cu wire only) wire only) 1A 1C 175 2/0-#14 70-2.5 1 2/0-#14 70-2.5 1 100kA 2A 2C 175 2/0-#14 70-2.5 1 #2-#14 35-2.5 4 100kA 3A 3C 310 350-#6 185-16 2/0-#14 70-2.5 1 #8-#14 8-2.5 8 100kA 4A 4C 335 400-#6 185-16 1 400-#6 185-16 1 100kA 5A 5C 840 600-#4 300-25 2 600-#4 300-25 2 100kA Contact Mersen Technical Services at technicalservices.nby@mersen.com for fuse type and maximum ampere required. Multiple Wire Ratings (Same Size & Type Wires Only) 2/0 Openings #2 Openings (2) #4 AWG (2) #8 AWG (2) #12 AWG (2) #6 AWG (2-4) #10 AWG (2-4) #14 AWG (2) #6 AWG (2) #10 AWG (2) #14 AWG (2) #8 AWG (2-4) #12 AWG Dimensions 1A 2A 3A 4A 5A Dimension 1C 2C 3C 4C 5C Figure 1 Figure 1 Figure 2 Figure 1 Figure 2 mm in mm in mm in mm in mm in A 25.4 1.00 28.4 1.12 46.9 1.85 39 1.54 72 2.84 B 43.3 1.70 57.8 2.28 64.3 2.53 108 4.25 91 3.58 C 49.5 1.95 56.0 2.21 64.3 2.53 80 3.15 80 3.15 D 45.1 1.78 51.6 2.03 59.8 2.36 75.5 2.97 - - E 39.4 1.55 39.4 1.55 51.5 2.03 50.1 1.97 50.1 1.97 F 72.6 2.86 87.7 3.45 100.8 3.97 145.5 5.73 145 5.71 G 59.6 2.35 74.6 2.94 82.4 3.24 120.6 4.75 127.5 5.02 H 5.3 0.21 5.1 0.20 6.5 0.26 7 0.28 3 0.12 I - - - - 31.5 1.24 - - 52 2.04 J 5.3 0.21 6.4 0.25 6.5 0.26 6.5 0.26 6.5 0.26 K 10 0.40 11.7 0.46 8.9 0.35 16 0.63 8.5 0.34 Figure 1 K Figure 2 H Accessories Catalog No. FSPIN1 FSCIM1 FSCIM2 FSCAP1 FSCAP2 FSCAP3 FSEA Description Accessory pin to form multiple pole block Circuit identification marker for 2/0 & #2 max. conductors (80 per card) Circuit identification marker for 350, 400 & 600 kcmil max. conductors (56 per card) Cap plug for spare 2/0 openings Cap plug for spare 350 kcmil openings Cap plug for spare 600 kcmil opening Pair of end anchors H I K B F G B G E D C A J E D C F J A ep.mersen.com I3

Properties of Materials* Fuse Blocks, Fuseholders, Power Distribution Blocks, Fuses & Accessories Property Units Astm Glass Filled Polyethelene Polysulfone Phenolic Polyamide Test Polycarbonate Terphthalate Copolymer Polyphtalamide Nylon Specific Gravity - D792 1.4 1.21 1.36 1.67 1.52 1.71 1.16 IZOD ft-lb/in D256 0.29 4-6 3.2 1.7 1.8 1.5 0.63 Flexural Strength psi D790 11,000 13,200 38,000 29,000 26,900 37,300 18,500 Flexural Modulus psi D790 1.1 x 10 6 325,000 1.25 x 10 6 1.5 x 10 6 1.4 x 10 6 1.9 x 10 6 4.3 x 10 5 Tensile Strength psi D638 7,000 9,000 25,000 20,000 17,600 26,000 12,000 Compressive Strength psi D695 28,800 12,500 34,000 29,000 - - - Water Absorption 24 hrs % D570 0.45 0.15 1.3 0.05 0.1 0.18 1.5 Hardness Rockwell D785 M-110 M-85 R-105 R-120 - - - Dielectric Strength 60 hertz, 25ºC, s/t kv/in - 300 425 435 460 500 460 432 60 hertz, 25ºC, s/s kv/in - 250 425-355 - - - Dielectric Constant 60 hertz dry - D150 5.96 3.01-3.8 - - - 1 Mhertz dry - D150 4.9 2.96 3.6 3.7 3.8 4.9 3.6 Volume Resistivity ohm-cm D257 50 x 10 6 >101 6 101 6 >101 5 >101 6 3 x 101 6 >101 6 Heat Deflection ºF D648 320 270 410 435 330 523 167 (ºF @ 264 psi) Flammability - - 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0 94 V-0 (UL 94) Relative Thermal Index (RTI) (UL746B) Electrical ºC - 150 125 150 155 150 140 140 Mechanical without ºC - 150 125 140 155 150 130 110 impact *Note: Above data represents approximate values and are for Product Types & Families reference only. 64XXXX MPDB USM GPM SHR AOS 22XXXX DRM USCC FEB EI 24XXXX DFC USGM FEX 26XX 603XXX USGCC IL P266 203XXX US3J TPMOV P243 206XXX US6J Surge Trap 1MSC 303XXX US14 1SC PS2OX127 306XXX US22 FHXXX P243X CC 703XX MSC U705XX NH U710XX 21XXXX 61XXXSJ P 61XXXX 62XXXX P61

Mersen Product Selector Tools Select-A-Fuse The industry s first point-and-click, Windows -based fuse selection software, Select-A-Fuse is fast, easy and accurate. With Select-A-Fuse, you can quickly and accurately choose the right overcurrent protection for low- and medium-voltage motors, power and control transformers, and general loads. With Version 4.1, you can do even more. Because in addition to product specs, melting time and peak let-thru curves, and the ability to check fuse coordination, our enhanced Select-A- Fuse software package features: Select-A-SPD Quickly and accurately choose the right residential, commercial, and industrial surge protection device (SPD). Access Select-A-SPD online Select-A- Access Select-A-, Select-A- Enclosed, and Select-A-Elevator to choose the right switch. Access Select-A- online An Arc Flash calculator you can use to calculate incident heat energies for Mersen s Amp-Trap 2000 current-limiting fuses Data and selection routines for our low- and medium-voltage capacitor fuses, High-Speed J fuses and finger-safe power distribution blocks A cross-reference list with more than 18,000 entries Select-A-Fuse will save you time and effort, and best of all, it s free. Visit the web address below to get your copy today. Select-A-PDB Quickly find a power distribution block for your application by entering your desired attributes from pre-populated drop-down menus. Access Select-A-PDB online Access Select-A-Fuse online Q Q9

Wind Power Circuit Protection Mersen brings its knowledge, innovation and technical expertise to the wind power industry, with a complete line of problem-solving products. A wide range of circuit protection solutions are available for the Nacelle, Utility and Tower Base, including Fingersafe Power Distribution Blocks () Time-delay Class J Fuses (), E-Rated Current-limiting Power Fuses and more. Download Mersen s wind power solutions brochure at ep-us.mersen.com > Resources > Literature. To learn more about how Mersen products can protect people and equipment: Call: 978-462-6662 Email: info.nby@mersen.com Web: ep-us.mersen.com Mersen Electrical Protection 5 6 Turbine Component Fuses Surge Protection Other 4 1 Control Cabinet 3 2 1 Nacelle 2 Rotor 3 Stator NH - G NH - G Associated Associated 4 HUB 5 Obstruction Lighting 6 Anemometer Midget 12 Base 7 Heading Control Cabinet 8 (230V) Control Cabinet 9 (24V/ 48V) NH Midget NH or NH 11 10 7 9 8 Both 10 11 12 Inverter for Rotor Power Supply Transformer & Utility Lines Inverter & Generators PSC Form101 NH - g NH Holder Cable Protector High High Heatsinks Q12