Polymer Insulator. ITEM 15kV 25kV 35kV 69kV. Section length(l) 330±15mm 445mm 539mm 888mm. Min. arcing distance 215mm 300mm 340mm 701

Similar documents
HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

KC5 PV Charge Controller Instruction Manual

PO Box 2484 Rowville Vic 3178

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Distribution Arresters

GROUP D. Switch & Protective device.

High Voltage Surge Arresters Station Class

LS0512 Solar Charge Controller

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

USER MANUAL MPS 1-5KW SERIES

LS0512R Solar Light Controller

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Solar Inverter 3kW-8kW Inverter (off-grid)

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Solar Inverter Manual

EE 741 Over-voltage and Overcurrent. Spring 2014

Duo Battery Charge Controller

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Solar Power System. User Manual

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

MEDIUM VOLTAGE NETWORKS

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

SCC-MPPT Solar Charge Controller

Solar Charge Controller

SCC-MPPT Solar Charge Controller

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

SCC-MPPT Solar Charge Controller

Figure 1. HX cutout fuseholders.

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

Surge Arrester 3EL2 superior protection up to 550 kv

Solid Dielectric, Three Phase Reclosers CATALOG VS11

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Suitcase solar power system

34-SDMS-01 SPECIFICATIONS FOR

Figure 1. HX cutout fuseholders. Positive Interruption

Domae. The right solution for distribution boards

3EQ Composite Housed Surge Arresters

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

شركة كهرباء محافظة القدس المساهمة المحدودة

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Directly Molded Polymer Surge Arresters

PRODUCT CATALOGUE. Overhead System

EPEVER. LS-E Series. Solar Charge Controller USER MANUAL

3EK7 Medium Voltage Silicone Insulated Surge Arresters

3EP6 porcelain surge arrester

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Product Group Brochure. PS Range Capacitor Vacuum Switches

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Technical Specification for Pole Mounted Capacitor Rack

1 Phase electronic contactor (SC 1)

User Manual. Solar Charge Controller 3KW

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

GENERAL. CONSTRUCTION External

Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line

SPECIFICATIONS LOW COST 2404R CHARGER

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Eclipse Solar Suitcase

SPECIFICATIONS CAA Supercharger

KC3 PV Charge Controller Instruction Manual

POLYMER INSULATOR. Index

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

3EK7 Distribution Class Surge Arresters. Answers for energy.

SPECIFICATIONS SRF SuperchargerPlus

To ensure proper installation, digital pictures with contact information to before startup.

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

LS1024R / LS1524R / LS2024R. Solar Light Controller INSTRUCTION MANUAL

K-Limiter high ampere Companion II fuse

USER MANUAL. Insulation Tester + DMM. Model MG320

True RMS Autoranging Multimeter

Manual Installation & Operation

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

OTEC Transfer switch open transition

Safety technique. Emergency Stop Module BH 5928, BI 5928

SPECIFICATIONS SRF

General Precautions. Personnel Precautions

Transcription:

Polymer Insulator Characteristics of Polymer Insulator The main element of polymer insulator displays very excellent properties in terms of heatproof performance, chemical stability, electrical insulation, wear resistance and glossy performance compared to general organic rubbers thanks to its both sides nature-organic and inorganic properties expressed simultaneously by silicone. Merits of Polymer Insulator 1. Light weight : Lighter than porcelain insulator, providing easy work and shortened period of construction(reducing power interference by shortened electricity failure time) 2. Elastic body : Easier handing and transportation by reduced damage from careless 3. Weather resistance : Reducing maintenance cost without need for washing or cleaning 4. Water repellency : Excellent insulation performance with water-resistion properties Product Picture Specification ITEM 15kV 25kV 35kV 69kV Section length(l) 330±15mm 445mm 539mm 888mm Dimension Leakage distance 439mm 642mm 850mm 2037mm Min. arcing distance 215mm 300mm 340mm 701 Electrical Rating Mechanical Rating Low frequency dry flash over voltage test Low frequency wet flash over voltage test Critical impulse flashover voltage test Radio influence Voltage test 97 143 168 260 67 115 137 210 Positive 173 217 258 425 Negative - 304 340 425 Max. Voltage test 1(Max) 1(Max) 1(Max) 3 Phase to earth 20 25 25 30 Failing load test 700kgf 700kgf 700kgf 1000kgf Number of sheds 4 6 8 15

CUT OUT SWITCH Introduction The Cut out switch is used with expulsion fuse links for sectionalizing and transformer protection. Features of cut out switchs include, Fuse holders are mutually Interchangeable with the other company s cutouts. Single vent and drop-out type. Repeated usability after operation (replace the fuse link only) Cut out provide reliablee protection from low level overload that just melt the fuse link. Superior breaking capability from intermediate through maximum interrupting current. Product Picture Drop-out action Outdoor distribution Single-Insulator (Polymer) Light-Weight Hot Stick operation Specification Bending Nominal Power freq. voltage Lighting Impulse No. TYPE Withstand Creepage Withstand Load(kN) Distance(mm) Dry Wet voltage(kv) 1 YJC27K 7 580 60 50 150 2 YJC36K 7 680 90 70 170

LIGHTNING ARRESTER Introduction & Installation Polymer-housed arresters are used for limiting the overvoltage due to a lightning and switching surge to the required protective level. The superior protective characteristics of arrester provide level. The superior protective characteristics of arrester provide excellent overvoltage protection for distribution system equipments. Features of arresters include, Light weight and easy installation. Excellent discharge capacity compared with porcelain-housed arrester Verified the performance in contaminated environments. Insulated mounting base and ground lead isolator, wildlife protector available(optionally). Product Picture 10kV Electrical Character TYPE Rated Voltage(kN ) MCOV (kv) Steep Current Impulse Switching Current Impulse Lighting Current Impulse High Current Impulse KW10A-9 9 7.65 28.5 23.1 27 100 KW10A-12 12 10.2 38.5 30.8 69 100 KW10A-15 15 12.7 47.5 38.5 45 100 KW10A-18 18 15.3 57.0 46.2 54 100 KW10A-21 21 17.0 66.5 53.9 63 100 KW10A-24 24 19.2 76.0 61.6 72 100 KW10A-27 27 21.9 85.5 69.3 81 100 KW10A-36 36 29.0 114 92.4 108 100

INTERRUPTER SWITCH Introduction Interrupter switch(lbs) is a three phase transmission part operated swith utilized to sectionalize or isolate circuits on electrical distribution systems up through 25.8KV, the distribution switch is rated for 600 amperes continuous current and 40.000 amperes momentary. Specification Items Data Origin Rated voltage(kv) 24/25.8 Rated current(a) 600/630 Momentary(KA) 40 1 sec(ka) 25 Rated frequency(hz) 50/60 Han Sung/ Withstand voltage(1 Min, Dry)(KV) 70 Korea Impulse withstand voltage(kv) 150 Support insulator (polymer) TR-208 Weight(Kg) 90 Tolerance ±5%

Vertical Axis Wind Turbine Introduction This product can be used by in any areas where has good wind resource, such as building roofs in cities, environment favorable buildings, and dependent small power stations in suburbs. It can provide stable and reliable electricity for lighting, household electrical appliances, beacon light, microwave communication, equipment, meters. It is ideal power supply equipment for families and companies. Specification P - 10 Mill diameter:30cm Blade length:30cm Start up wind speed: Working wind speed: 4.20m/ /s Rating wind speed: 10m/s Safe wind speed: 40m/s Rating out put: DC 12V Brake style: Mechanism Net weight: 20kg (No pillar) P - 300 Mill diameter:138cm Blade length:130cm Start up wind speed: 2m/s Working wind speed: 4-25m/ /s Rating wind speed: 10m/s Safe wind speed: 40m/s Rating out put: DC28/36V Brake style: Mechanism Pillar high: 5.5m Net weight: 90 Kg (No Pillar)

P - 1000 Mill diameter:180cm Blade length:200cm Start up wind speed: 2m/s Working wind speed: 4-25m/ /s Rating wind speed: 12m/s Safe wind speed: 50m/s Rating out put: DC48V Brake style: Mechanism Pillar high: 5.5m Net weight: 180 Kg (No Pillar) P 3000 Milll diameter:300cm Blade length:360cm Start up wind speed: 2m/s Working wind speed: 4-25m/s Rating wind speed:12m/s Safe wind speed: 50m/ /s Rating out put: AC230/ /115V Brake style: Mechanism Pillar high: 5.5m/11m Net weight: 500 Kg (No Pillar)

SOLAR HOME SYSTEM General Information. I. Use MCU and professional software as the control center to fulfill intelligent system control. II. The accurate control point depends on the battery discharge rate, final discharging voltage is the control point of corrected discharging curve. eliminate the discrepancy by the single voltage control, meet the battery characteristics, which is different charge rate has different final voltage. III. With intelligent protection against over charging, over discharging, electronicc short-circuit, over load, polarity reverse and etc. no damage for any components, and no burning for the fuse. IV. With series PWM charging circuit, the voltage loss of charging loop is only half of the LED charging circuit, the charging efficiency is higher 3% %-6% than the ON/OFF one, and saved the energy. The boost, direct, and float charging enhanced the lifetime of the system. Also it has specific temperature compensation. V. Direct LED indicator for the statues of the system. With flash memory saving the control make the setting digital, eliminate the discrepancy. VI. One key setting, easy and convenient. Specifications Type Rated charge current Rated DC load current Rated AC load Capacity Work voltage Solar home system 50W MAX DC 10A MAX DC 10A MAX 150W DC 12V / AC 220V

1.25 rated load current 60sec Over load, short circuit protection DC 1.5 rated loads current 5sec over load protection action. 3 Rated load current short circuit protection action. AC Fuse Quiescent current 6 ma Charge circuit voltage drop DC 0.26V Load circuit voltage drop DC 0.15V Over voltage protection Work temperature Boost charge voltage Direct charge voltage 17V Industry stage:-35 to +55 ;Commercial stage -5 to +50 14.6V; (keep 10min) 14.4V; (keep 10min) Float charge voltage 13.6V charge return voltage 13.2v Temperature compensation -5mv/ /2v(Boost charge, Direct charge, Float charge, charge return voltage); Lower voltage indicate 12.0V Over discharge voltage Over discharge return voltage Over-discharge pressed return voltage DC Control mode 11.1V(no load)- modified voltage by discharge rate of battery; 2/24V 13.1 V 12.4 V PWM charge mode; modified discharge voltage by the discharge rate Description Rated Power Voltage Using Time Fluorescent lamp 1EA 7 W 12Vdc 50 Hour Radio 1EA 50W 12Vdc 7 Hour 14 Notebook 75W 220Vac 5 Hour 19 Color TV 160W 220Vac 2 Hour Desktop Computer with Monitor 500W 220Vac 1 Hour