Control Box CBJ1 / CBJ2. Data sheet LINAK.COM/MEDLINE-CARELINE

Similar documents
Actuator LA44. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CB12. Data sheet LINAK.COM/MEDLINE-CARELINE

ACTUATOR LA28 PRODUCT DATA SHEET

Actuator LA32. Data sheet LINAK.COM/TECHLINE LINAK.COM/MEDLINE-CARELINE

Actuator LA34. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA43. Data sheet LINAK.COM/MEDLINE-CARELINE

Battery Li-Ion BA21. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA27 HOMELINE Analogue. Data sheet LINAK.COM/HOMELINE

Actuator LA23. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator systems for patient lifts

Actuator LA31. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA30. Data sheet LINAK.COM/TECHLINE LINAK.COM/MEDLINE-CARELINE

Actuator LA40. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA27. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA40. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA23 DESKLINE. Data sheet LINAK.COM/DESKLINE

Actuator LA29. Data sheet LINAK.COM/HOMELINE

Kick & Click TM. Data sheet LINAK.COM/DESKLINE

Kick & Click TM. Data sheet LINAK.COM/DESKLINE

Actuator systems for hospital beds Perfection in movement LINAK.COM/MEDLINE-CARELINE

ACTUATOR LA31 PRODUCT DATA SHEET

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C

DESKLIFT TM DL6. Data sheet LINAK.COM/DESKLINE

LIFTING COLUMN LC2 PRODUCT DATA SHEET

ACTUATOR LA44 PRODUCT DATA SHEET

Actuator LA35. Data sheet LINAK.COM/TECHLINE

Better Solutions - Better Care. Product Overview LINAK.COM/MEDLINE-CARELINE

Focus on marine LINAK.COM/TECHLINE

Focus on Ventilation and Farming Solutions LINAK.COM/TECHLINE

MOVE ON GO ELECTRIC! A Comparison of motion control systems: - Hydraulic - Electric

Focus on. Mining Equipment.

ACTUATOR LA31 PRODUCT DATA SHEET

esense article overview E series Document ID: E1409_ _esense 9000 article overview_r10.00

LIFTING COLUMN BL3 PRODUCT DATA SHEET

All-in-One Hoist User Manual , , ,

JUMO MIDAS Pressure transmitter

LIFTING COLUMN LC2 PRODUCT DATA SHEET

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing

TA1. series. Comfort Motion Care Motion Auto Motion Ergo Motion. Product Segments

Hoyer Elara The illuminating solution for your ceiling lift needs.

NCF fans 60Hz. Protection class IP 55

4-11 CB20 Features Options

U S E R M A N U A L INTELLIPAC Contact Vancare:

Maxi Sky 2 Plus The complete ceiling lift system

ACTUATOR LA30 PRODUCT DATA SHEET

Liko M220 / Liko M230

NCF 60 Hz. Protection class IP 55

Eva400EE/Eva400EM. Functional inspection. Always read the manual. SystemRoMedic TM. Manual - English

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Thermal Overcurrent Circuit Breaker 3120-F...

Energy Monitoring (Plug-in to II *1 )

Preface... 4 Valid for... 5 Important information... 6 Safety instructions... 6 Manufacturer s declaration... 8

ORION PLUS three-phase kVA

NCF fans 50 Hz. Protection class IP 55

Thermal Overcurrent Circuit Breaker 3120-F...

Mounting- and operating instructions Indoor Air Quality Guard LGW-13 CO 2 Detector

Technical Data Sheets

LineaSPACE flush-mounting cabinets 8, 12 & 18 modules

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

AKM 105, 115: Rotary actuator for ball valve

EXCa. Exhaust register

Bocube. Colour: Graphite grey, similar to RAL 7024; light grey, similar to RAL 7035; special colours on request

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Thermal Overcurrent Circuit Breaker 3120-F...

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

SKF linear motion solutions for medical equipment

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Thermal-Magnetic Circuit Breaker M1-..

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Inclined Platform Lifts SUPRA & SUPRA LINEA

Polyester-Enclosures MBP

Inclined Platform Lifts SUPRA & SUPRA LINEA

Maxi Sky 2 A complete patient handling system

Safety Sensor CSS 180 Product Information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Single foot switches PX and PA series

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing Push Handle. Base Width Adjustment Handle.

HEINE NT4 MED V

LE-12 VIGO 2 with scale system LE-13 VIGO 3. ICU beds.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

LED safety Luminaries

Isolating transformer ES710

TIG. Product Catalogue 1.0 / V1.

PRODUCT CATALOGUE. Innovative mounting solutions for projectors, flat panels & whiteboards. Flat Panel Kiosks & Housings

2.7. IT system floor-standing distribution cabinet Series -IPS-F

MAXI SKY with people in mind

Leading the way in hazardous areas Features EATON

NBE50-250/205 A-F2-A-BAQE

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Thermal Circuit Breaker / Switch Series 3131

Electronic Circuit Breaker ESS20-0..

Technical Data Sheets

Thermal Circuit Breaker / Switch Series 3131

atient lifters Assembly, Maintenance & Specifications Manual SUNRISE HML400 Hoyer Manual Patient Lift HPL400 Hoyer Power Patient Lift Sunrise Medical

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

Technical Data Sheets

Transcription:

Control Box CBJ1 / CBJ2 Data sheet LINAK.COM/MEDLINE-CARELINE

CBJ1 / CBJ2 The control boxes CBJ1 and CBJ2 are part of the battery driven JUMBO system. JUMBO is a modular system combining an actuator, a control box (CBJ1, CBJ2), a battery (BAJ1) and a charger (CHJ2) in a flexible solution, specially developed for patient lifts. The complete system is medically approved and contains a series of features which meet the patients need for a safe and comfortable lift, e.g. CBJ1 and CBJ2 are equipped with a soft-start/stop function, emergency lowering function etc. CBJ1 and CBJ2 are available in a special edition that can be used in the harsh conditions in the pool environment both outdoor and indoor. Features and Options: Output voltage: 24 V DC Soft start/stop on channel 1 Emergency operation for lifting/lowering (CBJ1), Emergency function down (CBJ2) Acoustic battery alarm at approx. 50% battery capacity Bayonet lock for locking the handset plug (The DIN-plug) Protection class: IPX5 Colours: Dark grey (RAL 7016) or light grey (RAL 7035) bottom and light grey top (RAL 7035) Electronic overload protection (EOP) 2 speed operation of the actuator on channel 1 (CBJ1) Matching handset for: CBJ1: HB30, HB51J, HB52J, HB53J, HB70 and HB80 CBJ2: HB30, HB51B, HB52B, HB70 and HB80 Emergency stop button LCD-display showing the actual battery capacity and indicating when the battery needs recharging Socket for external battery pack. This socket for external battery pack enables furthermore charging of the JUMBO battery pack BAJ1 with CH01 through the control box. Internal charger possible Possible to mount an Emergency Stop Guard Customised front covers Variable current cut-off Pool Lift version Features and Options - differs from CBJ1, CBJ2 - Improved contact terminals - Rubber seal around contact terminals - Stainless steel screws - Robot injected sealing glue - Internal charger not possible - Always external charger CHJ2 - No display option - No emergency stop - Always IPX5 Usage: Duty cycle: Max. 10% or 2 min. continuous use then 18 min. without use Ambient temperature: +5 to +40 C For one or two actuators (lift and leg spreader actuator) Approvals: IEC60601-1:2005 3 rd edition, ANSI / AAMI ES60601-1:2005 3 rd edition, CAN / CSA-22.2 No 60601-1:2008 LINAK.COM/MEDLINE-CARELINE

Dimensions: Emergency stop guard Combination examples: BAJ1/2 BAJ1/2 BAJ1/2 CBJ1/CBJ2 w/o internal charger CHJ2 CHJ2 CBJ1/CBJ2

CBJ1/CBJ2 Ordering example: IP-rating: 1 = IPX5 4 = IPX4 Front cover: See the front cover table for details - xx (last 2 digits) 01-99 Type Charger Display Emergency stop Front cover no. Front cover CBJ1 A, B, E, F 0 0 04 00J1CB004 A, B, E, F 0 1,3 02 00J1CB002 A, B, E, F 1 0 03 00J1CB003 A, B, E, F 1 1,3 01 00J1CB001 C, D, G, H 0 0 None - C, D, G, H 0 1,3 09 00J1CB009 C, D, G, H 1 0 None - C, D, G, H 1 1,3 08 00J1CB008 CBJ2 A, B, E, F 0 0 09 00J2CB009 A, B, E, F 0 1,3 02 00J2CB002 A, B, E, F 1 0 17 00J2CB017 A, B, E, F 1 1,3 03 00J2CB003 C, D, G, H 0 0 08 00J2CB008 C, D, G, H 0 1,3 04 00J2CB004 C, D, G, H 1 0 54 00J2CB054 C, D, G, H 1 1,3 01 00J2CB001 C, D, G, H 1 1,3 51 00J2CB051* *Light Grey Bottom plastic: Emergency stop: LCD display: Option: Version: 1 = RAL7016, dark grey (Standard) 2 = RAL7035, light grey 0 = without emergency stop 1 = with emergency stop 3 = with emergency stop and guard 0 = without LCD display 1 = with LCD display A = LINAK battery BAJ1 and BAJ2 B = External batteries via CBJ1 plug C = LINAK batteries BAJ1 and with internal charger. (Max. IPX4) D = External batteries and with internal charger (Max. IPX4) E = LINAK battery BAJ1 and BAJ2 and variable current cut-off CH1 F = External batteries via CBJ1 plug and variable current cut-off CH1 G = LINAK batteries BAJ1, int. charger and variable current cut-off CH1 (Max. IPX4) H = External batteries, int. charger and variable current cut-off to CH1 (Max. IPX4) (see the combinations table on next page) 1N 1H 2N 2H 3H Only for CBJ2 4H 5N 5H 6H Only for CBJ2 7H Only for CBJ2 8H Only for CBJ2 Not used: Type: CBJ1 or CBJ2 * Pool lift version should be ordered as special article. Please contact LINAK A/S sales for further information if you need this CBJ1 or CBJ2 solution.

Internal battery charger: The internal charger is a Switch Mode Power Supply (SMPS) version which makes charging of the batteries more efficient. The charging time for a BAJ1 battery pack is approx. 4-5 hours. Mains voltage from 100-240 V AC (50 / 60 Hz) is possible on same charger. The charger indicates whether the charger is connected to mains (green LED) or whether the battery is being charged (yellow LED). Medically approved. When connected to mains (AC) When connected to mains (AC)

Recommendations: The mains cable must always be ordered separately when ordering a CBJ1, CBJ2 with an internal charger. Use only original LINAK mains cables to ensure proper connection to internal charger. Standard front covers for version without internal charger. CBJ1 00J1CB001 00J1CB002 00J1CB003 00J1CB004* CBJ2 00J2CB002 00J2CB003 00J2CB009* 00J2CB017 *Standard front covers for pool lift

Standard front covers for version with internal charger. CBJ1 00J1CB008 00J1CB009 Standard front covers for version with internal charger. CBJ2 00J2CB001 00J2CB004 00J2CB008 00J2CB051 00J2CB054

JUMBO combinations CHJ2 BAJ1, BAJL CH01 LA23 HB70 LA28 HB80 LA30 DIN CH2 JACK HD80 CH1 JACK LA31 HB30 LA44 LA23 LA43 LA28 LA31 LA34 LA30 LA31 Copyright LINAK 2017.10. MA M9-02-097-X. Chapter 7.2 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK. FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER S MANUALS