Getting Started With Your System

Similar documents
System 3 ZB1PS Device Chassis. Operator s Manual

DP140e. Installation & Operations Manual

Technical Specifications

Installing the Switch Chassis

Technical Specifications

E-Series and EF-Series Systems

Expansion Modules for Dell PowerConnect Switches

Powerware Vdc Extended Battery Cabinet User s Guide.

Revision A

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

Cabinet and Rack Installation

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

NetSure. 211 Series DC Power System

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

SCXI Power Supply/Float Charger Installation Guide

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Digital/Analog Amplifiers Installation Instructions

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

BroadBand PowerShield. 20 AHr Battery. User Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DART Charger Product Description, Information and Specification

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

CPS2000 Cabinet Power System

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Expansion Signal (XSIG) Card Installation Instructions

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Cabinet and Rack Installation

The Power of Reliability INSTRUCTION MANUAL

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

High Frequency SineWave Guardian TM

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Cabinet and Rack Installation

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Galaxy Receiving and Unpacking 09/

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Cabinet and Rack Installation

Seeker HL Source Transmitter. User s Guide

UPS5000-E (25-75 kva) Series

Top Microsystems Proprietary Specification P/N: A190047LV6 FSM RB VA.1 SPECIFICATION

Installation Instructions. Y-Series Brushless Servo Motor

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

AeroVironment Universal Solar Pump Controllers

1U 4 Bay Chassis Rack Mounting Instructions

IOA Expansion Cabinet. Dual Line Cords Upgrade Instructions

Innovative Circuit Technology Ltd.

CTFRP Series Power Supplies

G2 Portable oxygen concentrator User Manual

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

POWER-WIN TECHNOLOGY CORP.

Model 700 Microarray Oven

ActiveLED Solar and DC Systems

AccuPower AQU128B Installation Instructions

ComfortPoint Programmable Lon, VAV/Unitary Controllers

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

MRC-135A Single Battery Solar Charger Operation Manual

VERTIV XTE 401 SERIES. Ordering Guide

Low Profile DC Power Supply with Zero Voltage Soft Switching

Power Inverter 400 MW Owner s Manual

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS XX and XX Series Electric Attitude Indicator

Applications. Overview. Technical Specifications

Model Fixed Rack-Mount Kit

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Power Consumption Reduction: Hot Spare

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

GB60S 60W Single Output General Purpose Series

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Technical Information Manual

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

and other -48VDC Power Systems. 19 or 23 Wide (Nominal) Relay Rack (part of system).

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

FULL REDUNDANCY POWER SYSTEM

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

Power and Cooling. Chassis Power System

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Flex Amplifiers Installation Instructions

Model G14SD Vapor Management System

V1606 3U RACK ENCLOSURE

Power Supplies PSS Series

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Installation and Operations Manual

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Cisco Nexus 7700 Switches Environment

Transcription:

Dell PowerConnect RPS720, MPS600, MPS1000, and MPS 1U Shelf Getting Started With Your System Regulatory Model PowerConnect RPS720, MPS600, and MPS1000

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Information in this publication is subject to change without notice. 2010 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, and PowerConnect are trademarks of Dell Inc. EMC is a registered trademark of EMC Corporation. Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Regulatory Model PowerConnect RPS720, MPS600, and MPS1000 November 2010 P/N KPCT8 Rev. A00

Features Dell PowerConnect RPS720 Figure 1-1. Front Panel Indicators-PowerConnect RPS720 Supports up to four PowerConnect switches through 12 V DC output Dedicated 180 W power supply for up to four connected switches Front panel LEDs display status of individual power supplies 1U, 19-inch rack mountable system NOTE: The PowerConnect RPS720 redundant power bank provides four external redundant power supplies for your PowerConnect switches, eliminating the power supply as a single point of failure. Dell PowerConnect MPS600 Figure 1-2. Front Panel Indicators-PowerConnect MPS600 Supports one PowerConnect 55xxP (PoE) switch through 48 V DC output Dedicated 600 W power supply for one connected switch Front panel LEDs display status of the power supply Getting Started With Your System 3

1U, 19-inch rack mountable system with brackets Up to three MPS600 units in a MPS 1U Shelf (density 3per 1U, 19-inch rack) Dell PowerConnect MPS1000 Figure 1-3. Front Panel Indicators PowerConnect MPS1000 Supports one PowerConnect 70xxP (PoE+) switch through 54 V DC output Dedicated 1000 W power supply for one connected switch Front panel LEDs display status of the power supply 1U, 19-inch rack mountable system with brackets Up to three MPS1000 units in a MPS 1U Shelf (density 3 per 1U, 19-inch rack) Unpacking Package Contents Before you install the RPS720, MPS600, MPS1000, or MPS 1U Shelf, verify your package contents for: One of the following units: RPS720 Redundant power bank (supports up to four switches) MPS600 Modular power supply 600 watts MPS1000 Modular power supply 1000 watts MPS 1U Shelf Mechanical shelf holds up to three MPS600, MPS1000, or a combination 4 Getting Started With Your System

Rack mounting kit AC power cord: RPS720 Type C13 plug MPS600 Type C13 plug MPS1000 Type C15 plug (with notch) Switch DC power cords: RPS720 14-pin DC power cords (4) MPS600 16-pin DC power cord (1) MPS1000 16-pin DC power cord (1) Installation WARNING: Before performing the following procedure, review the safety instructions that came with the system. CAUTION: Before you install the PowerConnect RPS720, MPS600, or MPS1000, consult your PowerConnect Switch User's Guide to confirm that your switch supports the PowerConnect RPS720 redundant power bank or the MPS600/MPS1000 external power supply. PowerConnect RPS720 Installing PowerConnect RPS720 on a Flat Surface You can install the PowerConnect RPS720 on any appropriate level surface that can safely support the weight of the switches, the PowerConnect RPS720, and their attached cables. There must be adequate space around the PowerConnect RPS720 for ventilation and to access cable connectors. CAUTION: Allow at least 2 inches (5.1 cm) on each side for proper ventilation and 5 inches (12.7 cm) at the back for power cord clearance. 1 Set the RPS720 on a flat surface and check for proper ventilation. 2 Attach rubber feet (optional) on each marked location at the bottom of the chassis. NOTE: Although optional, rubber feet are recommended to keep the unit from slipping. Getting Started With Your System 5

Installing PowerConnect RPS720 in a Rack The PowerConnect RPS720 can be installed in most standard 19-inch racks. NOTE: For racks that are not pre-threaded, cage nuts are provided. Figure 1-4. Attaching Mounting Brackets PowerConnect RPS720 3 Use the screws that are provided to attach a mounting bracket to each side of the PowerConnect RPS720. 4 Position the PowerConnect RPS720 in the rack and align the holes in the mounting bracket with the holes in the rack. 5 Insert and tighten two screws through each of the mounting brackets. 6 Getting Started With Your System

Operating the PowerConnect RPS720 After Installation 1 Plug one end of the switch DC power cord (14-pin) into the connector labeled RPS on the back of the switch. Connect the other end of the switch DC power cord to any available RPS connector on the back of the PowerConnect RPS720. Figure 1-5. Back View PowerConnect RPS720 2 Attach the AC power cord to the PowerConnect RPS720 and to an AC power outlet. The switch is now using both power supplies simultaneously. You can monitor the status of the two power supplies through the front panel LEDs on your PowerConnect switch and the PowerConnect RPS720. PowerConnect MPS600 or MPS1000 Installing PowerConnect MPS600 or MPS1000 on a Flat Surface You can install the PowerConnect MPS600 or MPS1000 on any appropriate level surface that can safely support the weight of the switch, the PowerConnect MPS600 or MPS1000, and their attached cables. There must be adequate space around the PowerConnect MPS600 or MPS1000 for ventilation and to access cable connectors. CAUTION: Allow at least 2 inches (5.1 cm) on each side for proper ventilation and 5 inches (12.7 cm) at the back for power cord clearance. 1 Set the PowerConnect MPS600 or MPS1000 on the flat surface and check for proper ventilation. 2 Attach rubber feet (optional) on each marked location at the bottom of the chassis. NOTE: Although optional, rubber feet are recommended to keep the unit from slipping. Getting Started With Your System 7

Installing PowerConnect MPS600 or MPS1000 in a Rack The PowerConnect MPS600 or MPS1000 can be installed in most standard 19-inch racks. NOTE: For racks that are not pre-threaded, cage nuts are provided. Figure 1-6. Attaching Mounting Brackets PowerConnect MPS600 or MPS1000 3 Use the screws that are provided to attach a mounting bracket to each side of the PowerConnect MPS600 or MPS1000. 4 Position the PowerConnect MPS600 or MPS1000 in the rack and align the holes in the mounting bracket with the holes in the rack. 5 Insert and tighten two screws through each of the mounting brackets. 8 Getting Started With Your System

Operating the PowerConnect MPS600 or MPS1000 After Installation 1 Plug one end of the switch DC power cord (16-pin) into the connector labeled MPS on the back of the switch. Connect the other end of the switch DC power cord to the DC OUT connector on the back of the PowerConnect MPS600 or MPS1000. Figure 1-7. Back View PowerConnect MPS600/MPS1000 2 Attach the AC power cord to the MPS600 or MPS1000 and to an AC power outlet. The switch is now using both power supplies simultaneously. You can monitor the status of the two power supplies through the front panel LEDs on your PowerConnect switch and the MPS600 or MPS1000. PowerConnect MPS 1U Shelf Installing PowerConnect MPS 1U Shelf on a Flat Surface You can install the PowerConnect MPS 1U Shelf on any appropriate level surface that can safely support the weight of up to three switches, up to three PowerConnect MPS600 or MPS1000, and their attached cables. There must be adequate space around the PowerConnect MPS 1U Shelf for ventilation and to access cable connectors. CAUTION: Allow at least 2 inches (5.1 cm) on each side for proper ventilation and 5 inches (12.7 cm) at the back for power cord clearance. 1 Set the PowerConnect MPS 1U Shelf on the flat surface and check for proper ventilation. 2 Attach rubber feet (optional) on each marked location at the bottom of the chassis. NOTE: Although optional, rubber feet are recommended to keep the unit from slipping. Getting Started With Your System 9

Installing PowerConnect MPS 1U Shelf in a Rack The PowerConnect MPS 1U Shelf can be installed in most standard 19-inch racks. NOTE: For racks that are not pre-threaded, cage nuts are provided. 1 Use the screws that are provided to attach a mounting bracket to each side of the PowerConnect MPS 1U Shelf. 2 Position the PowerConnect MPS 1U Shelf in the rack and align the holes in the mounting bracket with the holes in the rack. 3 Insert and tighten two screws through each of the mounting brackets. Operating the PowerConnect MPS600 or MPS1000 in the MPS 1U Shelf After Installation 1 Install up to three PowerConnect MPS600 or MPS1000 (or combinations) into the MPS 1U Shelf. Figure 1-8. Back View PowerConnect MPS 1U Shelf 2 Plug one end of the switch DC power cord (16-pin) into the connector labeled MPS on the back of an available switch. Connect the other end of the switch DC power cord to the DC OUT connector on the back of an available PowerConnect MPS600 or MPS1000. 3 Attach the AC power cord to the PowerConnect MPS600 or MPS1000 and to an AC power outlet. The switches are now using both power supplies simultaneously. You can monitor the status of the all the power supplies through the front panel LEDs on your PowerConnect switches and the PowerConnect MPS600s or MPS1000s. 10 Getting Started With Your System

Other Information You May Need WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. The rack documentation included with your rack solution describes how to install your system into a rack. The PowerConnect Switch User Guides provide information about system features and describes how to troubleshoot the system and install or replace system components. These documents are available online at support.dell.com/manuals. NOTE: Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents. Obtaining Technical Assistance If you need help with a technical problem, see the Dell Support website at support.dell.com for the latest updates on documentation and firmware. Technical Specifications PowerConnect RPS720 The PowerConnect RPS720 contains four independent 180 W power supplies. Physical Height Width Depth 43.2 mm (1.7 in) 440 mm (17.32 in) 257 mm (10.18 in) Getting Started With Your System 11

180 W AC-DC power supply NOTE: The power supply has an universal input (90 VAC to 264 VAC) and a 12 VDC regulated output. This regulated output supplies power to other power supply backup source. The power supply incorporates over current protection and OVP. Input Voltage Universal input 90 to 264 VAC Nominal input 15 to 230 VAC. Input Frequency Range 47 to 63 Hz Max. Input AC Current 2.3 A max per supply (9.2 A total for four supplies in PowerConnect RPS720) Output Voltage and Current Parameter 12 V output unit Nominal Output Voltage +12 V Absolute Maximum Tolerance +/- 5 % Output Ripple Voltage 500 mv pk-pk Minimum Current 0.0 A Maximum Current 15 A DC FAN Specification Bearing Type Two-ball bearing Rated Voltage 12 V DC Operating Voltage Range 7.0 V 13.8 V Speed (Reference Value) 9000 RPM Air Delivery 10.10 CFM Noise 32.5dB Operating Temperature -20 to +70 ºC Storage Temperature -40 to +70 ºC 12 Getting Started With Your System

PowerConnect MPS600 The PowerConnect MPS600 contains a 600 W power supply. Physical Height Width Depth 41.6 mm (1.64 in)(maximum) 133.8 mm (5.27 in)(maximum) 401.4 mm (15.8 in)(maximum) 600 W AC-DC power supply NOTE: The power supply has an universal input (90 VAC to 264 VAC) and a 12 VDC regulated output. This regulated output supplies power to other power supply backup source. The power supply incorporates over current protection and OVP. Input Voltage Universal input 90 to 264 VAC Input Frequency Range 47 to 63 Hz, single phase AC Max. Input AC Current 8.0 A (maximum) Output Voltage and Current No of Output 1 Nominal Output Voltage Set Point 48 V DC Set Point Tolerance +/- 1% Total Error Band +/- 2% Minimum Current 1.0 A Maximum Current 12.5 A PowerConnect MPS1000 The PowerConnect MPS1000 contains a 1000 W power supply. Physical Height Width Depth 41.6 mm (1.64 in)(maximum) 133.8 mm (5.27 in)(maximum) 401.4 mm (15.8 in)(maximum) Getting Started With Your System 13

1000 W AC-DC power supply NOTE: The power supply has an universal input (100 VAC to 240 VAC). This regulated output supplies power to other power supply backup source. The power supply incorporates over current protection and OVP. Input Voltage Universal input 100 to 240 VAC Input Frequency Range 47 to 63 Hz, single phase AC Max. Input AC Current 12.0 A (maximum) Output Voltage and Current No of Output 1 Nominal Output Voltage Set Point 48 V DC Set Point Tolerance +/- 1% Total Error Band +/- 2% Minimum Current 1.0 A Maximum Current 18.52 A PowerConnect MPS 1U Shelf Physical Height Width Depth 44 mm (1.73 in)(maximum) 440 mm (17.32 in)(maximum) 402 mm (15.83 in)(maximum) PowerConnect RPS720, MPS600, and MPS1000 Environmental Considerations NOTE: For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets. Temperature Operating 0 to 45 C (32 to 113 F) Relative humidity Operating 0% to 95% (noncondensing) Altitude Operating 0 to 3,048 m (0 to 10,000 ft) 14 Getting Started With Your System