HPK04 Max Flow: 120 gpm (454 lpm)

FPK02 In-Line Cartridge Filters

FPK04 Max Flow: 100 gpm (379 lpm)

HMK05/25 DURAMAX Spin-Ons

Medium Pressure Filters

Suction Filters S8-455 SE56-560

Medium Pressure Filters

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

High-pressure inline filter, flangeable

Duplex Pressure Filters

LIQUID PURIFICATION SYSTEMS FLUSHING SYSTEMS & SERVICES

HIGH PRESSURE FILTERS

MEDIUM PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Block mounting filter, lateral flange-mounting possible

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Series RFL In-Line Filter

Low / Medium Pressure Duplex Filter Inline mounting. Type : 40/160-LD/LDN. Filters. Accumulators. Hydraulic Symbol. Technical Data

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

Replacement cartridge filter

SPIN-ON FILTERS & ELEMENTS

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

50P Series High Pressure Filters

10 Hydraulic Filters

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Low Pressure Filters

10 Hydraulic Filters

Series RFLD Duplex In-Line Filter

FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need

NFH Low Pressure Filters

MPD Series. Medium Pressure Duplex

MPD Series. Medium Pressure Duplex

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology

Low Pressure Medium Pressure High Pressure Accessories Off-line Filtration

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

IL8 Series. Medium Pressure Filters

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

15P/30P Series High Pressure Filters

MPD Series Medium Pressure Filters

Low & High Pressure ProGuard Filters

15/40/80CN Series. Medium Pressure Filters

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Stainless Steel Pressure Filters

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

IL8 Series. Medium Pressure Filters

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

World Pressure Filters A new standard in 7,000 psi pressure filters

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

Inline filter with filter element according to DIN 24550

15/40/80CN Series Coreless Medium Pressure Filters

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

VacuClean Systematic Oil Treatment Patented

Line filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Accessories. Service, In-Line and Reservoir. Accessories ACCESSORIES

12CS/50CS Series. Coreless Spin-on Filters

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

WITH P INDICATOR OPTION INDICATOR POSITION # INDICATOR POSITION # P3000G04=4.0" P3000G08=7.8"

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

Type 400LDN0040 to 1000; 400LD0130, 0150

Return Line Filter RF

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Moduflow. ILP and RFP Low Pressure Filters. Series

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Low Pressure Filters

Block mounting filter, for vertical flange-mounting

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

THE IMPORTANCE OF AN EFFICIENT FILTRATION

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

In line high pressure filters. HF 735 series

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

RF4 Series. Return Line Filters

HYDRAULIC AND LUBE OIL FILTERS RFM Series

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

12CS/50CS Series Coreless Medium Pressure Filters

Inline filter with filter element according to DIN 24550

Transcription:

DT-35 In-Line Hydraulic Filter Features The DT-35 T-type ported series offers flows to 5 gpm with 3 bypass options and conforms to the HF3 automotive standard. Our standard bowl drain plug helps relieve system pressure during filter change-outs. Donaldson Triboguard TM 5-layer media is offered in a variety of designs. Five different media grades are offered. Donaldson elements core collapse options range from 15 to 3, psi. The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal lockout and surge control are two key features incorporated in the differential indicators. 5 gpm (189 l/min) Conforms to HF3 specifications Wide range of indicator options High collapse element available for use in non-bypass applications Fluorocarbon seals standard Max. Working Pressure Fatigue Pressure Rating Typical Burst Pressure Operating Temp. Range Head Material Bowl Material Weight (w/o elements) 3, psi (1 bar) 1,5 psi (1 bar) 7,5 psi max (517 bar) - to 5 F (-9 to 11 C) Cast Iron Steel Assembly length 4 : 13 lbs (5,9 kg) Assembly length 8 : 15 lbs (6,8 kg) Technical Data DT-35 series filter housing is a suitable replacement for competitor filter housings such as: Pall 965, Schroeder TF3, Parker 3P, Hydac LF

DT-35 Performance Data Housing and Filter Element Flow versus Pressure Drop 15 SUS (3 cst.) oil with specific gravity <.9 Viscosity Correction Formula ΔP Element = ΔP from curve x New Viscosity (SUS) x New Specific Gravity 15.9 ΔP Housing = ΔP from curve x New Specific Gravity.9 ΔP Assembly = ΔP Element + ΔP Housing 5 Housing Only Bypass Valve PSID 4 3 1 1 3 4 GPM 5 6 PSID 1 5 9 PSID cracking 5 PSID cracking 5 PSID cracking 1 3 4 5 GPM PSID DT-96-4 LPM 4 6 8 1 1 14 µm 5 µm 1 8 µm 15 1 14 µm 8 1 6 5 µm 4 5 1 3 4 GPM kpa PSID DT-96-8 LPM 4 6 8 1 1 14 16 18 µm 1 15 5 µm 1 8 8 µm 1 6 14 µm 4 5 5 µm 1 3 GPM 4 5 kpa

DT-35 Ordering Code Example Model Housing Length Bypass Valve Indicator Porting Element Construction Micron Rating DT-35 1 A B B A 14 TABLE 1 TABLE TABLE 3 TABLE 4 TABLE 5 TABLE 6 Housing shipped without element. Select one option from each table below. (See example shown above.) TABLE 1 Housing Length 1 4 A No bypass TABLE Bypass Valve A TABLE 3 Indicator Visual Indicator 35 psid 8 B 5 psid bypass C Visual/Electrical 35 psid C 9 psid bypass B Visual Indicator 7 psid D Visual/Electrical 7 psid N No indicator A SAE-1 O-Ring TABLE 4 Porting TABLE 5 Element Construction A Standard ( psid) TABLE 6 Micron Rating Beta 1, at < 4 micron B SAE-16 O-Ring B High Collapse (3, psid) 5 Beta 1, at 5 micron Please note: Element selection to be ordered separately. 8 Beta 1, at 8 micron 14 Beta 1, at 14 micron 5 Beta 1, at 5 micron Length 1 Element Chart Micron Rating Construction 5 8 14 5 A DT-96-4-µm DT-96-4-5µm DT-96-4-8µm DT-96-4-14µm DT-96-4-5µm B DT-961-4-5µm DT-961-4-14µm A DT-96-8-µm DT-96-8-5µm DT-96-8-8µm DT-96-8-14µm DT-96-8-5µm B DT-961-8-5µm DT-961-8-14µm

DT-35 Components Electric Indicator (Aluminum Housings) Schematic Wiring Diagram Note: The female plug (connector) is to be furnished by customer Differential Indicators Indicators are designed to actuate at approximately 8% of bypass valve cracking pressure. It is recommended that an indicator with a bypass setting of 7 psid is used with a non-bypass housing. Surge Control This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surge control delays the indicator response. Thermal Lockout Thermal Lockout (TL), prevents actuation below 6 F and allows actuation above 1 F system operating temperature. Its purpose is to avoid false actuations during periods of high fluid viscosity such as experienced during cold start. Dimensions: millimeter (inch) Donaldson Company, Inc. P.O. Box 199 Minneapolis, MN 5544-199 U.S.A. Tel 8.846.1846 Fax 95.73.4913 hydraulicfilters@mail.donaldson.com www.donaldson.com Information in this document is subject to change without notice. 7 Donaldson Co., Inc. Printed in U.S.A. on recycled paper Bulletin No. HYD-53

DT-44 In-Line Hydraulic Filter Features The DT-44 filter assembly can be manifold mounted to the hydraulic system. The size and material configuration are well-suited for today s demanding proportional and servo valve applications. Our standard bowl drain plug helps relieve system pressure during filter change-outs. Donaldson Triboguard TM 5-layer media is offered in a variety of designs. Five different media grades are offered. Donaldson elements core collapse options range from 15 to 3, psi. The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal lockout and surge control are two key features incorporated in the differential indicators. gpm (91 l/min) Conforms to HF specifications High collapse element available for use with non-bypass applications Positive sealing poppet bypass for reliability and zero leakage Wide range of indicator options Compact design for use with servo or proportional valve Two bowl length options for design flexibility Fluorocarbon seals standard Max. Working Pressure Fatigue Pressure Rating Typical Burst Pressure Operating Temp. Range Head Material Bowl Material Weight (w/o elements) 4, psi (76 bar),45 psi max (169 bar) 1, psi max (69 bar) - to 5 F (-9 to 11 C) Cast Iron Steel Assembly length 4 : 8.4 lbs (3,8 kg) Assembly length 8 : 1.6 lbs (4,8 kg) Technical Data DT-44 series filter housing is a suitable replacement for competitor filter housings such as: Pall 9, Schroeder DF4, Parker 15P, Hydac HFP, Eaton HFP

DT-44 Performance Data Housing and Filter Element Flow versus Pressure Drop 15 SUS (3 cst.) oil with specific gravity <.9 Viscosity Correction Formula ΔP Element = ΔP from curve x New Viscosity (SUS) x New Specific Gravity 15.9 ΔP Housing = ΔP from curve x New Specific Gravity.9 ΔP Assembly = ΔP Element + ΔP Housing 4 Housing Only 1 Bypass Valve PSID 18 1 6 PSID 9 6 3 9 PSID cracking 5 PSID cracking 4 8 1 16 GPM 4 6 1 18 4 GPM DT-9-4 LPM 3 1 3 4 5 µm 5 µm DT-9-8 LPM 3 1 3 4 5 6 7 µm PSID 1 8 µm 14 µm 5 µm 15 1 5 kpa PSID 1 5 µm 8 µm 14 µm 5 µm 15 1 5 kpa 5 1 15 GPM 5 1 15 GPM PSID DT-91-4 LPM 3 1 3 4 5 5 µm 15 14 µm 1 1 5 kpa PSID DT-91-8 LPM 3 1 3 4 5 6 7 5 µm 14 µm 1 15 1 5 kpa 5 GPM 1 15 5 1 15 GPM

DT-44 Ordering Code Example Model Housing Length Bypass Valve Indicator Porting Element Construction Micron Rating DT-44 C D M A 5 TABLE 1 TABLE TABLE 3 TABLE 4 TABLE 5 TABLE 6 Housing shipped without element. Select one option from each table below. (See example shown above.) TABLE 1 Housing Length 1 4 A No bypass TABLE Bypass Valve A TABLE 3 Indicator Visual Indicator 35 psid 8 B 5 psid bypass C Visual/Electrical 35 psid C 9 psid bypass B Visual Indicator 7 psid D Visual/Electrical 7 psid N No indicator M Manifold Mount TABLE 4 Porting TABLE 5 Element Construction A Standard (15 psid) TABLE 6 Micron Rating Beta 1, at < 4 micron B High Collapse (3, psid) 5 Beta 1, at 5 micron Please note: Element selection to be ordered separately. 8 Beta 1, at 8 micron 14 Beta 1, at 14 micron 5 Beta 1, at 5 micron Length 1 Element Chart Micron Rating Construction 5 8 14 5 A DT-9-4-µm DT-9-4-5µm DT-9-4-8µm DT-9-4-14µm DT-9-4-5µm B DT-91-4-5µm DT-91-4-14µm A DT-9-8-µm DT-9-8-5µm DT-9-8-8µm DT-9-8-14µm DT-9-8-5µm B DT-91-8-5µm DT-91-8-14µm

DT-44 Components Electric Indicator (Aluminum Housings) Schematic Wiring Diagram Note: The female plug (connector) is to be furnished by customer Differential Indicators Indicators are designed to actuate at approximately 8% of bypass valve cracking pressure. It is recommended that an indicator with a bypass setting of 7 psid is used with a non-bypass housing. Surge Control This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surge control delays the indicator response. Thermal Lockout Thermal Lockout (TL), prevents actuation below 6 F and allows actuation above 1 F system operating temperature. Its purpose is to avoid false actuations during periods of high fluid viscosity such as experienced during cold start. Dimensions: millimeter (inch) Donaldson Company, Inc. P.O. Box 199 Minneapolis, MN 5544-199 U.S.A. Tel 8.846.1846 Fax 95.73.4913 hydraulicfilters@mail.donaldson.com www.donaldson.com Information in this document is subject to change without notice. 7 Donaldson Co., Inc. Printed in U.S.A. on recycled paper Bulletin No. HYD-54

DT-451 In-Line Hydraulic Filter Features The DT-451 base-mounted filter series provides for easy servicing featuring top cover access for element change out. The ductile iron filter head design provides for SAE ports along with optional space saving manifold mounting. This product features the popular HF4 automotive element. Donaldson Triboguard TM 5-layer media is offered in a variety of designs. Five different media grades are offered. Element core collapse options range from 15 to 3, psi. The differential pressure indicator line is designed to work with the wide assortment of bypass valves. Thermal lockout and surge control are two key features incorporated in all of the indicators. 15 gpm (568 l/min) Conforms to HF4 automotive specifications High collapse element available for use with non-bypass applications Three bowl length options for design flexibility Wide range of visual or electrical/visual indicators Diagnostic port in head for easy system analysis Drain port in base Fluorocarbon seals standard Max. Working Pressure Fatigue Pressure Rating Typical Burst Pressure Operating Temp. Range Head & Cap Material Bowl & Notched Material Weight (w/o elements) 4,5 psi (31 bar) 3, psi max (7 bar) 13,5 psi max (931 bar) -45 to 5 F (-43 to 11 C) Cast Iron Steel Assembly length 9 : 56 lbs (5,4 kg) Assembly length 18 : 8 lbs (37,5 kg) Assembly length 7 : 19 lbs (49,5 kg) Technical Data DT-451 series filter housing is a suitable replacement for competitor filter housings such as: Pall 97, Schroeder KF3 & KF5, Parker 5P, Hydac HF4P

DT-451 Performance Data Housing and Filter Element Flow versus Pressure Drop 15 SUS (3 cst.) oil with specific gravity <.9 Viscosity Correction Formula ΔP Element = ΔP from curve x New Viscosity (SUS) x New Specific Gravity 15.9 ΔP Housing = ΔP from curve x New Specific Gravity.9 ΔP Assembly = ΔP Element + ΔP Housing 9 Housing Only SAE 4 15 Bypass Valve PSID 6 1-1/ Flg. Mt. 3 35 7 15 15 GPM PSID 1 5 9 PSID cracking 5 PSID cracking 5 1 15 GPM PSID DT-HF4-9 LPM 4 8 1 16 15 1 5 µm 5 µm 8 µm 14 µm 5 µm 1 8 6 4 1 3 4 5 GPM kpa PSID DT-HF4-18 LPM 1 1 3 5 µm 6 µm 8 µm 5 4 5 14 µm 3 5 µm 1 4 6 8 1 GPM kpa PSID DT-HF4-7 LPM 1 3 4 5 1 µm 5 µm 6 5 8 µm 14 µm 5 µm 5 1 15 GPM 5 4 3 1 kpa Note: Pressure Drop curve for DT-HF4-HC elements was not available at the time this brochure was printed. Please, contact Donaldson Customer Support at 1-8-846-1846 for updated information.

DT-451 Ordering Code Example Model Housing Length Bypass Valve Indicator Porting Element Construction Micron Rating DT-451 1 A C M A 14 TABLE 1 TABLE TABLE 3 TABLE 4 TABLE 5 TABLE 6 Housing shipped without element. Select one option from each table below. (See example shown above.) TABLE 1 Housing Length 1 9 A No bypass TABLE Bypass Valve A TABLE 3 Indicator Visual Indicator 35 psid 18 B 5 psid bypass C Visual/Electrical 35 psid 3 7 C 9 psid bypass B Visual Indicator 7 psid D Visual/Electrical 7 psid N No indicator D G L M SAE-4 O-Ring TABLE 4 Porting 1½ SAE 4 bolt flange, Code 61 1½ SAE 4 bolt flange, Code 6 Manifold Mount TABLE 5 Element Construction A Standard ( psid) B High collapse (3, psid) Please note: Element selection to be ordered separately. TABLE 6 Micron Rating Beta 1, at < 4 micron 5 Beta 1, at 5 micron 8 Beta 1, at 8 micron 14 Beta 1, at 14 micron 5 Beta 1, at 5 micron Length 1 3 Construction Micron Rating 5 8 14 5 Element Chart A DT-HF4-9-µm DT-HF4-9-5µm DT-HF4-9-8µm DT-HF4-9-14µm DT-HF4-9-5µm B DT-HF4HC-9-µm DT-HF4HC-18-14µm A DT-HF4-18-µm DT-HF4-18-5µm DT-HF4-18-8µm DT-HF4-18-14µm DT-HF4-18-5µm B see below* see below* A DT-HF4-7-µm DT-HF4-7-5µm DT-HF4-7-8µm DT-HF4-7-14µm DT-HF4-7-5µm B see below** see below** *Requires () DT-HF4HC-9-xµm elements and (1) P16734 connector. **Requires (3) DT-HF4HC-9-xµm elements and () P16734 connectors.

DT-451 Components Electric Indicator (Aluminum Housings) Schematic Wiring Diagram 146.5 (5.75).35 (.88) Min Element Removal Clearance Refer To Model Code (Element Length) 8.77 (3.18) Torque Cover To Cylinder 73 N.M (55 Lbs-Ft) 139.7 (5.5) Fill Plug 7/16-UNF SAE-4 Straight Thread 38.1 (1.5) Hex Note: The female plug (connector) is to be furnished by customer 388.6 (15.3) 19.5 (.75) 67.38 (4.7) 863.6 (34.) 35.81 (1.41) P Indicator Differential Indicators Indicators are designed to actuate at approximately 8% of bypass valve cracking pressure. It is recommended that an indicator with a bypass setting of 7 psid is used with a non-bypass housing. Surge Control This optional feature is used to dampen pressure surges or spikes to avoid premature actuation of the indicator. Surge control delays the indicator response. 161.8 (6.37) Drain Plug 9/16-18UNF SAE-6 Straight Thread 17. (5.) 63.5 (.5) 5.8 (.) IN OUT Inlet Port (Outlet Port On Opposite Side) 114.3 (4.5) 57.15 (.5) Inlet and Outlet Port C'Bore 45.97 (1.81) Dia. 38.1 (1.5) Flow Port Dia. For Visual P Indicator Thermal Lockout Thermal Lockout (TL), prevents actuation below 6 F and allows actuation above 1 F system operating temperature. Its purpose is to avoid false actuations during periods of high fluid viscosity such as experienced during cold start. 7.87 (.31) Manifold Mounting Inlet and Outlet Port O-rings(-13) supplied. 8.64 (.34) 14.3 (.563) Thru 4 plcs 194.6 Max (7.64) 5.49 Max (8.9) For Electrical P Indicator Dimensions: millimeter (inch) Donaldson Company, Inc. P.O. Box 199 Minneapolis, MN 5544-199 U.S.A. Tel 8.846.1846 Fax 95.73.4913 hydraulicfilters@mail.donaldson.com www.donaldson.com Information in this document is subject to change without notice. 7 Donaldson Co., Inc. Printed in U.S.A. on recycled paper Bulletin No. HYD-55

Industrial Filters Accumulators High Pressure Duplex Filters 5/45 LD 3-145 5/45 LDN 4-1 Filters for inline installation for continuous operation LDN-Type with Filter Elements according to DIN 455 Optimised flow characteristics by 3D computer aided design Operating pressure: 5/45 bar Connections up to SAE Low pressure drop Special high efficient filter media Quality assured!

High Pressure Duplex Filters 5/45 LD 3-145 5/45 LDN 4-1 Operating pressure 5/45 bar Operating temperature -1 C up to +1 C Connections up to SAE Performance Characteristics Pressure drop curves for filter assembly Oil viscosity: 3 mm /s Specific weight: <,9 kg/dm 3 Recommended initial p for filter selection =, bar (5 LD/LDN)/,5 bar (45 LD/LDN) Recommended max velocity = 6 m/sec. (5 LD/LDN)/7m/sec. (45 LD/LDN) Application Filtration of liquids and lubricants. Filtration of liquids and gases. Installation in pipelines to protect subsequent system components from contamination. Continuous operation due to duplex filter design. Design Filter head with inlet, outlet and filter element spigots. Filter bowl is unscrewed downwards. Filter head includes further switching valve for closure ref. starting filter side. Material: as per spare part list in this brochure. Filter Element Pleated design with optimised pleat density and various filter media. The filter element is the most important component of the filter in view of prolonged life and wear protection of the system. Oil cleanliness, the initial pressure drop and the dirt holding capacity are the most important criteria for selection. For further detailed information please refer our Filter Elements brochure. A proper filter selection is enabled by our EPE- FILTERSELECT software. Accessories Maintenance Indicators For monitoring the filter element s contamination status; visual und visual/electrical indicators, with one or two switching points are available. Vent Valve For removing the air from the filter during start up and for secure de pressurising.

Ordering Information Selection of the filter size: using the computer program "EPE-FILTERSELECT or performance characteristics in this brochure. Special designs available on request.. LD Filter Type = Duplex filter with EPE standard filter element LDN = Duplex filter with filter element acc. to DIN 455 Magnet = Without Maintenance Indicator = Without A = Maintenance visual B = Maintenance visual/elect. with equipment connector thread D = Maintenance visual/elect. with signal lights and two switching points Standard switch pressure: 5, bar See illustrations of maintenance indicator for detailed information and technical data. Connection R = Pipe thread for 5/45 LD 3-13 and 5/45 LDN 4-1 S = SAE-flange for 5/45 LD 15-145 and 5/45 LDN 16-1 Material = Standard Filter Assembly 5 LD 13 H1SL B B5, R P Seal Kit 5 LD 13 H1 SL B R P Pressure 5 bar 45 bar Filter Element Type:. Nominal Size 5/45 LD... 3* 5 8 13 15 18 3 45 5/45 LD... 4 63 1 16 5 4 45 LD... 95 145 45 LDN... 63 1 *filter element.4 Filtration Grade Nominal filtration grade in µm G = Stainless steel wire mesh; cleanable G1 G5 G4 G6 G8 G1 VS = Nonwoven media, non cleanable VS5 VS4 VS6 P = Paper, not cleanable P5 P1 P5 Absulute filtration grade (ISO 457) in µm H SL = Micro glas-fibre, non cleanable H1SL H3SL H6SL H1SL HSL AS = Micro glas-fibre, water adsorbent, non cleanable AS1 AS3 AS6 AS1 AS Differential Pressure Maximum allowable differential pressure drop across the filter elementes A = 3 bar B = 33 bar C = 16 bar Filter Element Design = Standard adhesive T = 1 C E = Special adhesive T = 16 C = Standard material Z = Zinc free Bypass Valve = Without Seal P=Buna N V=Viton E=Ethylene- Propylene N=Neoprene Additional Information = Without 4 = Drain plug 5 = Silicone free A = Pressure equalisationline E = Vent valve Z = Inspection certificate 5 = Silicone free Z = Inspection certificate Filterelement. 13 H1SL B P Maintenanance Indicator The maintenance indicator monitors the degree of clogging of the filter elements: They are available as visual or visual/electrical displays. See Maintenance Indicator brochure for technical data. Filter Switching Symbol A A Visual B Visual/Electrical D Visual/Electrical with three 4 V diodes and two switching points Ordering information A5, = F5, A P* Ordering information B5, = F5, GW P* Switching symbol Ordering information D5, = R5, GW 9 ZP* Switching symbol B V1 LED/ green in use V LED/ red S=1% V3 LED/ yellow S=75% *P = Buna N, V = Viton, E = Ethylene-Propylene, N = Neoprene possible 3

Dimensions Filter Housing for Filter Elements according to EPE Standard Type Volume in ltrs. Weight in kg 1) A1 A A3 ) A4 A5 A6 B1 B B3 B4 B5 B6 B7 B8 C1 Connect. R/S C 5 45 C3 C4 D1 D SW 5/45 LD 3 x, 5/45 LD 5 x, 5/45 LD 8 x,3 1,5 1,5 14, 9 155 19 11 6 6 1 38 9 85 16 4 56 G 1 / Ø64 Ø67 Ø9 35 4 5/45 LD 13 x,5 18,5 45 5/45 LD 15 x,9 5/45 LD 18 x1,1 3, 34, 191 17,5 41 75 7,5 17 3 1 111 16 75 7,76 57,15 8 SAE 1 6 psi Ø9 M1 Ø14 36 5/45 LD x1,3 5/45 LD 3 x1,9 5/45 LD 45 x3, 56, 6, 66, 171 6 41 184 1 15 15 45 35 15 143 19 1 36,5 79,38 1 SAE 1 1 / 6 psi Ø114 M16 Ø18 5 43 3 45 LD 95 x4,5 45 LD 145 x6, 1,5 148,5 418 639 19 11 11 4 44 19 166 45 1 44,45 96,8 11 SAE 6 psi Ø14 M Ø3 Ø156 3 46 41 Filter Housing for Filter Elements according to DIN 455 Type Volume in ltrs. Weight in kg 1) A1 A A3 ) A4 A5 A6 B1 B B3 B4 B5 B6 B7 B8 C1 Connect. R/S C 5 45 C3 C4 D1 D SW 5/45 LDN 4 x, 1,5 9 5/45 LDN 63 x,3 14, 155 19 11 6 6 1 38 9 85 16 4 56 G 1 / Ø64 Ø67 - Ø9-35 4 5/45 LDN 1 x,5 18,5 45 5/45 LDN 16 5/45 LDN 5 5/45 LDN 4 45 LDN 63 45 LDN 1 x1,3 x1,9 x3, x4,5 x6, 56, 6, 66, 1,5 148,5 171 6 41 418 639 184 19 1 15 11 15 11 45 4 35 44 15 19 143 166 19 45 1 1 36,5 79,38 44,45 96,8 1 11 SAE 1 1 / 6 psi SAE 6 psi Ø114 M16 Ø18 Ø14 M Ø3 Ø156 5 3 43 46 3 41 1) = weight including standard filter element and maintenance indicator ) = servicing height for filter element replacement 4

Spare Parts List Part 1 3 3.1 4 5 6 7 8 9 1 1.1 11 1 13 14 15 16 17 18 19.1 1 Qty. 1 4 4 1 1 8 3 4 1 1 Size LD Size LDN Designation Filter head Filter bowl Filter element O-ring Supporting ring O-ring Bottom Supporting ring O-ring Plug Lever Clamping sleeve Hexagon screw Hexagon screw Hexagon screw Set screw Supporting ring O-ring O-ring Maintenance Indicator Maintenance Indicator Stud bolt Measuring connection Vent valve Sealing ring Measuring connection Pressure equalisation device Material GGG 5 C-steel/4CrMo5/4CrMo4 various Buna N/Viton Teflon Buna N/Viton 4CrMo4 Teflon Buna N/Viton St St Spring steel/a4 A4 8.8 8.8 St Teflon Buna N/Viton Buna N/Viton various various 8.8 St/Viton Bronze Iron St/Viton various 3 5 45 Switching lever indicates side in use 5 4 8 63 5 45 5 45 5 45 5 45 5 45 5 45 5 45 5 45 --- 45 Part-Number please indicate ordering information Filter please indicate ordering information Filter please indicate ordering information Filter Element please indicate ordering information Seal Kit please indicate ordering information Seal Kit please indicate ordering information Seal Kit 778 373 374 375 745 3434 747 3388 979 654 661 3959 71 715 719 please indicate ordering information Seal Kit please indicate ordering information Seal Kit please indicate ordering information Seal Kit please indicate ordering information Maintenance Indicator please indicate ordering information Maintenance Indicator 4371 18 18 18 18 18 18 18 18 18 18 848 848 848 848 848 848 848 848 848 please indicate ordering information Seal Kit 18 please indicate ordering information Filter indicate ordering inform. Seal Kit Quality and Standardisation The development, manufacture and assembly of EPE-industrial filters and filter elements is carried out within the framework of a certified quality-management-system in accordance with DIN EN ISO 91. Certification of the filters by accredited institutions (for example TÜV, GL, LRS, LRIS, ABS, BV, DNV, DRIRE, UDT etc.) is available on request. The stability calculation and testing of the filters proceeds according to existing pressure vessel regulations, as well as in accordance with national and international norms. The CE identification mark according to the Pressure Equipment Directive 97/3/EG depends upon the individual application and operating conditions. On request we will classify the filters. 13 1 15 18 16 3 5 45 4 95 63 145 1 --- 45 4374 5

Industrial Filters Accumulators K. & H. Eppensteiner GmbH & Co. KG Hardtwaldstraße 43 D-68775 Ketsch P.O. Box 11 D-68768 Ketsch Phone: +49 6 /6 3- Telefax: +49 6 /6 3-199 E-Mail: info@eppensteiner.de Internet: www.eppensteiner.de Installation, Starting and Maintenance Filter Installation Verify operating pressure with name plate information. Mount the filter assembly using mounting device on the head Part 1 considering flow direction (direction arrows) and servicing height required for cleaning/replacing elements Part 3. Remove dust protection plugs from filter inlet and outlet, screw filter in pipeline without tension stress. Connection of Electrical Maintenance Indicator See brochure 64 and list according this brochure. Starting Put valve handle Part 1 in the central position to fill both filter sides. Switch on system pump. Ventilate filter by opening the valves Part 19/Part, close when operating liquid emerges. Put valve handle Part 1 in end stop for standard operation. Maintenance The filter element is clogged and needs to be replaced or cleaned when at the operating temperature the visual indicator s Part 17 red pin reaches its final position and/or the electrical switch is activated. Filter Element Service Open pressure-equalisation valve Part to equalise pressure in both filter housings. Switch change over valve on other side by moving lever Part 1. Close pressure-equalisation valve Part. Open the valves Part 19/Part on the filter taken out of operation and reduce the pressure. Unscrew filter bowl Part /Bottom Part 6 (only 45 LD 145 and 45 LDN 1) of filter bowl Part and remove filter element Part 3, turning slightly off its spigot in the filter head (Part1). Check filter Part inside and clean if necessary. Replace filter element H SL, P, VS and AS. The filter element with G media is cleanable. The efficiency of the cleaning process depends on the characteristics of contamination and the final pressure drop prior to servicing/cleaning the element. If the differential pressure after the filter element s cleaning process exeeds more than 5% of the pre service value the G element also needs to be replaced. Install cleaned or replaced filter element by slightly turning it back on its spigot. 5/45 LD 3 45 or 5/45 LDN 4 4: Check o-ring Part 5 on filter bowl Part, replace in case of damage or wear. 45 LD 95 145 or 45 LDN 63 1: Check o-ring Part 8 on filter bowl Part, replace in case of damage or wear. Screw filter bowl Part /Bottom Part 6 and tighten it at hexagon bolt using a suitable tool. Open pressure-equalisation valve Part, ventilate filter by opening the valves Part 19/Part, close when operating liquid emerges. Close pressure-equalisation valve Part. Warning Assemble and disassemble filter only when system is switched off! Vessel is under pressure! Leave pressure-equalisation valve closed while filter housing is out fo service! Do not operate switching device while filter housing is out of service! Do not change maintenance indicator or pressure-equalisation valve when filter is under pressure: Functions and safety warranty only with EPE-spare part! Service filter only by trained personal! Technical modifications reserved! 6 51B-GB/1/.3/

5 gpm, 95 l/min FPK Highlights Working Pressures to: Rated Static Burst to: Flow Range to: 69 psi 4, kpa 4 bar 9135 psi 63, kpa 63 bar 5 gpm 95 l/min High Pressure Filters Features The FPK is built to withstand pressures upwards of 6 psi. It features a cast iron head and cold-extruded steel housing for ultimate strength and durability. This filter meets the HF in-plant automotive specification. Bypass options include 87 psid bypass, bypass with reverse-flow check valve, or no bypass. Take advantage of our Mix n Match system of in-stock heads, housings & cartridges so you can get exactly what you need! Likewise, choose the media type and configuration that s best for your application. All FPK filters contain Synteq, Donaldson s exclusive synthetic fiber media formulated especially for liquid filtration! (See page 8 for details on Synteq.) Beta Rating Performance to ß 6(c) =1 T-Type Porting Sizes SAE-1 O-Ring Ports (standard) Assembly Weight 4" Assembly: 9. lbs / 4. kg 8" Assembly: 13. lbs / 6. kg Replacement Filter Lengths 4" / 11.5mm 8" / 3mm Standard Bypass Ratings 87 psi / 6 kpa / 6 bar 87 psi Bypass with reverse-flow check valve No Bypass Operating Temperatures - F to 5 F / -9 C to 1 C Element Collapse Ratings 9 psi / kpa / bar (standard) 3 psi /,7 kpa / 7 bar (high collapse) 8 Call 1-8-846-1846

FPK Assembly - Side View 3.54 9. 1.61 41. for: Servo Valve Circuits In-Plant & Mobile Equipment Power Steering Circuits High Pressure Circuits Meets HF Specification 9.11 31.5 HOUSING Head - Top View 3.8 83.4 13.9 33.5 HOUSING 1.7 4 3.7 94.91 3. M8 X 17 X 1.81 46. Head - Side View High Pressure Filters OUTLET INLET 4.47 113.5 Indicator Plug Remove plug to install visual or electrical indicator. All dimensions above are shown in inches [millimeters] www.donaldson.com 81

5 gpm, 95 l/min High Pressure Filters FPK Components Element Choices Media Bx(c) = 1 Length Part Comments Number Rating (in./mm) No. No. 1 6μm 4.37/111 P16949 BunaN Seal P16718 Fluorocarbon Seal High Collapse 8.1/3 P167838 BunaN Seal P16718 Fluorocarbon Seal High Collapse No. 9μm 4.37/111 P16541 BunaN Seal 8.1/3 P16543 BunaN Seal No. ½ 1μm 4.37/111 P1656 BunaN Seal P167181 Fluorocarbon Seal High Collapse 8.1/3 P16515 BunaN Seal P167183 Fluorocarbon Seal High Collapse No. 9 3μm 4.37/111 P165136 BunaN Seal 8.1/3 P165138 BunaN Seal Filter Notes Synteq filter media, which is in all FPK filter cartridges, is compatible with petroleum based fluids, as well as with most phosphate esters, water oil emulsions, and HWCF (high water content fluids). If you re filtering petroleum-based oil, filters with seals made of BunaN are appropriate for most applications. If you re filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF over 15 F/ 83 C, use filters with seals made of fluorocarbon, such as Viton from DuPont Dow Elastomers, or Fluorel from 3M Company. Donaldson high collapse elements, with their steel endcaps and wire-backed media, are rated to withstand up to 3 psi/,7 kpa before collapsing. Housing Choices All FPK filters contain Synteq, our synthetic filter media designed especially for liquid filtration. Learn more about Synteq on page 8! Length (in./cm) Part No. 4" element P76769 8" element P7677 Head Choices Port Size 4 Bypass Rating Part No. 3/4" O-Ring* 87 psi Bypass P76766 3/4" O-Ring* 87 psi Bypass P76767 with reverse-flow check valve 3/4" O-Ring* No Bypass P76768 NOTE: Port is machined and plugged. Replace plug with indicator of choice: P171945 (visual) or P76156 (electrical). See illustration on opposite page for details. 8 Call 1-8-846-1846

FPK FPK Service Parts When installing the FPK housing onto an installed head, torque it to 15 ft-lbs. Visual Indicator P171945 5 bar, 7.5 psid Head Plug remove only when installing indicator. Filter Element AC/DC Electrical Indicator P76156 5 bar, 7.5 psid Housing Performance Data For a full explanation of how our performance curves were derived, see page 15. FPK 4" Element Only FPK 8" Element Only - oil before assembling High Pressure Filters FPK Housing Only www.donaldson.com 83

gpm, 75 l/min HPK Highlights Working Pressures to: Rated Static Burst to: Flow Range to: psi 13,79 kpa 137.9 bar 45 psi 31,3 kpa 31.3 bar gpm 75 l/min High Pressure Filters Features The HPK is a heavy-duty filter built for high pressure applications, with cast aluminum head and impact-extruded aluminum housing for strength and durability at relatively light weight. Take advantage of our Mix n Match system of in-stock heads, housings and cartridges so you can get exactly what you need! HPK is available with your choice of visual or AC/DC electrical indicators. Likewise, choose the bypass option that s right for your application 5 psi bypass, or no bypass. Seals made of fluorocarbon (such as Viton and Fluorel ) or BunaN are available with HPK. All HPK filters contain Synteq, our synthetic filter media designed especially for liquid filtration. Beta Rating Performance to ß 6(c) =1 T-Type Porting Sizes SAE-1 O-Ring Assembly Weight 4.3 lbs / 1.95 kg (short) 5.5 lbs /.49 kg (long) Replacement Filter Lengths 4.37" / 111mm 8.1" / 6mm Standard Bypass Ratings 5 psi / 345 kpa / 3.5 bar No Bypass Operating Temperatures - F to 5 F / -9 C to 11 C Element Collapse Ratings 15 psi / 135 kpa / 1.6 bar (standard) 3 psi /,7 kpa / 6.9 bar (high collapse) 76 Call 1-8-846-1846

HPK Assembly - Side View for: Servo Valve Circuits In-Plant & Mobile Equipment Meets HF Specification Power Steering Circuits High Pressure Circuits Short Assembly Long Assembly High Pressure Filters Head - Top View with Visual Service Indicator on both sides with Electrical Service Indicator on left side and Visual Indicator on right side All dimensions above are shown in inches [millimeters] www.donaldson.com 77

5 gpm, 95 l/min HPK Components Element Choices Media Bx(c) = 1 Length Part Comments Number Rating (in./mm) No. No. 1 6μm 4.37/111 P16949 BunaN Seal P16718 Fluorocarbon Seal High Collapse 8.1/3 P167838 BunaN Seal P16718 Fluorocarbon Seal High Collapse No. 9μm 4.37/111 P16541 BunaN Seal 8.1/3 P16543 BunaN Seal No. ½ 1μm 4.37/111 P1656 BunaN Seal P167181 Fluorocarbon Seal High Collapse 8.1/3 P16515 BunaN Seal P167183 Fluorocarbon Seal High Collapse No. 9 3μm 4.37/111 P165136 BunaN Seal 8.1/3 P165138 BunaN Seal High Pressure Filters Filter Notes Synteq filter media, which is in all FPK filter cartridges, is compatible with petroleum based fluids, as well as with most phosphate esters, water oil emulsions, and HWCF (high water content fluids). If filtering petroleum-based oil, filters with seals made of BunaN are appropriate for most applications. If filtering diester, phosphate ester fluids, water glycol, water/oil emulsions, or HWCF over 15 F/ 83 C, use filters with seals made of fluorocarbon, such as Viton from DuPont Dow Elastomers, or Fluorel from 3M Company. Donaldson high collapse elements, with their steel endcaps and wire-backed media, are rated to withstand up to 3 psi/,7 kpa before collapsing. Housing Choices Length* Part No. short long * See dimensional drawings on page 77. P167443 P16745 Head Choices Port Size Bypass Rating Indicators 1 Part No. SAE-1 O-Ring 5 psi Visual indicator, left side 1, P16778 SAE-1 O-Ring No bypass Visual indicator, left side 1, P16773 Notes on Indicators 1 Donaldson uses the inlet port as the reference point. Left side, for instance, means that the indicator mounts on the side of the filter head that is on your left when you face the inlet port. Alternate indicator choice: Electrical Indicator (P16698, illustrated on pages 56-57) mounts in place of the visual indicator on the left side. Visual indicator can then be moved to the right side of the head, which is drilled and tapped with blank plate installed. 78 Call 1-8-846-1846

HPK HPK Service Parts When installing the HPK housing onto an installed head, torque it to 15 ft-lbs. Visual Service Indicator P164315 (includes O-Ring & hardware) Max Temp: 18 F/83 C Set: 5 psi/345 kpa or use blank plate P166134 AC/DC Electrical Service Indicator P16698 (3-wire switch in conduit box, for left side of head only) Max Temp: 5 F/11 C Set: 5 psi/345 kpa Voltage: 1 VAC / 8 VDC Current: 5 ma Circuit: Normally open (red) / normally closed (blue) / common (white) - oil before assembling Performance Data O-Ring P161315 Fluorocarbon Size 6 For a full explanation of how our performance curves were derived, see page 15. Blank Plate P166134 installed with two P161315 Fluorocarbon O-Rings on R side of head - o Head Assembly P16773 no bypass P16778 5 psi (Includes head seal) Head Seal P16768 Fluorocarbon Replacement Filter Synteq Filter Media (see list, page 78) Housing P167443 short P16745 long High Pressure Filters HPK 4" Element Only HPK 8" Element Only HPK Housing Only PRESSURE DROP (PSID) 15 1 5.75 " PORT 5 1 15 5 3 FLOW (gpm) www.donaldson.com 79

6 gpm, 7 l/min HPK3 Highlights Working Pressures to: Rated Static Burst to: Flow Range to: 3 psi,7 kpa 6.9 bar 6 psi 41,4 kpa 413.8 bar 6 gpm 7 l/min High Pressure Filters Features The sturdy HPK3 filter is constructed of ductile iron for durability in high pressure applications. Standard bowl drain plug means simplified servicing. Bowl includes a fluoroelastomer head-to-housing seal. Meets HF3 specification. Take advantage of our Mix n Match system of in-stock heads and cartridges so you can get exactly what you need! HPK3 is available with your choice of visual or AC/DC electrical indicators. Likewise, choose the bypass option that s right for your application 5 psi or no bypass. Seals made of fluorocarbon (such as Viton and Fluorel ) or BunaN are available with HPK3. All HPK3 filters contain Synteq, our synthetic filter media designed especially for liquid filtration. Beta Rating Performance to ß 6(c) =1 T-Type Porting Sizes SAE-1 O-Ring SAE-16 O-Ring Assembly Weight 6 lbs / 11.8 kg Replacement Filter Lengths 8" / 3mm Standard Bypass Ratings 5 psi / 345 kpa / 3.5 bar No Bypass Operating Temperatures - F to 5 F / -9 C to 11 C Element Collapse Ratings psi / 138 kpa / 13.8 bar (standard) 3 psi /,7 kpa / 6.9 bar (high collapse) 84 Call 1-8-846-1846

HPK3 Assembly - Side View for: High Pressure Circuits In-Plant & Mobile Equipment Servo Valve Circuits Meets HF3 specifications Torque housing to 75 ft-lbs. Head - Top View High Pressure Filters Standard Head - Top View with Visual Service Indicator left side, blank plate right side Alternate Head - Top View with Electrical Service Indicator left side All dimensions above are shown in inches [millimeters] www.donaldson.com 85

5 gpm, 95 l/min HPK3 Components Element Choices Media Bx(c) = 1 Part Seal Comments Number Rating No. No. 1 6μm P16784 BunaN No. 1 6μm P167185 Viton High Collapse for No Bypass applications. No. 9μm P164594 BunaN No. 9μm P16461 Viton No. ½ 1μm P164166 BunaN No. ½ 1μm P167186 Viton High Collapse for No Bypass applications. No. 4 μm P164365 Viton No. 9 3μm P164174 BunaN No. >5μm P165319 BunaN Media Part Seal Comments Number No. No. 74 75μm nominal P1633 BunaN Wire Mesh Media All HPK3 filters contain Synteq, our synthetic media specially-developed for liquid filtration. Find out more on page 8! High Pressure Filters Filter Notes SEALS: Filters with seals made of BunaN are appropriate for most applications involving petroleum oil. Filters with seals made of Viton (a fluoroelastomer) are required when using diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF (high water content fluids) over 15 F. (Viton is a registered trademark of DuPont Dow Elastomers.) SYNTHETIC MEDIA: Synteq filter media is compatible with petroleum based fluids, most phosphate esters, water oil emulsions, and HWCF (high water content fluids). Donaldson high collapse filters are physically designed to withstand up to 3 psi /,7 kpa before collapsing. Housing The P179579 housing is 1.73 inches (73mm) long and accepts the filter element that is 8 inches (3mm) long. It includes a head-to-housing seal. Head Choices Port Size 4 Bypass Rating Indicators 1 Part No. SAE-16 O-Ring 5 psi Visual indicator, left side 1, P166353 SAE-1 O-Ring 5 psi Visual indicator, left side 1, P17489 SAE-1 O-Ring No bypass Visual indicator, left side 1, P17491 Notes 1 Donaldson uses the inlet port as the reference point. Left side, for instance, means that the indicator mounts on the side of the filter head that is on your left when you face the inlet port. Alternate indicator choice: electrical indicator (P16698) mounts in place of the visual indicator on the left side. Visual indicator can then be moved to the right side of the head, which is drilled and tapped with blank plate installed. 86 Call 1-8-846-1846

HPK3 HPK3 Service Parts Visual Service Indicator P164315 (includes O-Ring & hardware) Max Temp: 18 F/83 C Set: 5 psi/345 kpa or use blank plate P166134 AC/DC Electrical Service Indicator P16698 (3-wire switch in conduit box, for left side of head only) Max Temp: 5 F/11 C Set: 4 psi/76 kpa Voltage: 1 VAC / 8 VDC Current: 5 ma Circuit: Normally open (red) / normally closed (blue) / common (white) O-Ring P161315 Viton Size 6 - o - o Head O-Ring Size 38 P165 BunaN P16588 Viton Head Assembly (3 choices, listed in table on p.86) Replacement Filter Synteq media on all, except No.74, which has Wiremesh media (listed in table on p.86) Housing P179579 (with Viton O-Ring) - oil before assembling Performance Data For a full explanation of how our performance curves were derived, see page 15. Drain Plug Kit: P169564 (with Viton O-Ring) O-Ring Size 98 P16375 BunaN P169563 Viton High Pressure Filters HPK3 Element Only HPK3 Housing Only 1 1 #1 # 8 PRESSURE DROP (PSID) 8 6 4 #.5 #9 # PRESSURE DROP (PSID) 6 4 3/4" PORT 1" PORT 1 3 4 5 6 FLOW (gpm) 1 3 4 5 6 FLOW (gpm) www.donaldson.com 87

1 gpm, 454 l/min HPK4 Highlights Working Pressures to: Rated Static Burst to: Flow Range to: 6 psi 41,4 kpa 413.8 bar 1 psi 88 kpa 87.6 bar 1 gpm 454 l/min High Pressure Filters Features The HPK4 high pressure filter series is made of ductile iron for strength and durability. Machined bypass valves are case-hardened at critical points to provide maximum strength and reliability. Reverse flow bypass valve allows bi-directional flow through the filter head, and filter changeout is simplified with standard bowl drain plug. Meets HF3 specification. Take advantage of our Mix n Match system of in-stock heads, housings & cartridges so you can get exactly what you need! Likewise, choose the media type and configuration that s best for your application. Filter cartridges for HPK4 contain Synteq, Donaldson s exclusive synthetic fiber media formulated specially for liquid filtration. Beta Rating Performance to ß 6(c) =1 T-Type Porting Sizes SAE- O-Ring 1¼" & 1½" SAE 4-Bolt Flange (codes 61, 6) Assembly Weight 8" Assembly: 6 lbs / 1 kg 16" Assembly: 39.5 lbs / 18 kg Replacement Filter Lengths 8" / 3mm 16" / 46mm Standard Bypass Ratings 6 psi / 414 kpa / 4.1 bar 9 psi / 61 kpa / 6. bar with reverseflow check valve No Bypass Operating Temperatures - F to 5 F / -7 C to 11 C Element Collapse Ratings psi / 138 kpa / 13.8 bar (standard) 3 psi /,7 kpa / 6.9 bar (high collapse) 88 Call 1-8-846-1846

HPK4 Assembly - Side View Long Assembly (16" element) for: High Pressure Circuits Hydrostatic Transmissions Servo Valve Circuits Meets HF3 Specifications Short Assembly (8" element) Torque housing to 75 ft-lbs. Torque housing to 75 ft-lbs. Head - Top View High Pressure Filters With Visual Service Indicators With Electrical Service Indicator Bypass Valve Alternatives INLET OUTLET FILTERED FLOW BYPASS FLOW INLET OUTLET FILTERED FLOW BYPASS FLOW INLET 6 psi / 414 kpa Bypass Valve 9 psi / 61 kpa Bypass Valve with Reverse Flow Check Valve No Bypass All dimensions above are shown in inches [millimeters] www.donaldson.com 89

1 gpm, 454 l/min High Pressure Filters HPK4 Components Element Choices Media Bx(c) = 1 Length Part Number Rating (in./mm) No. Comments 1 6μm 8/3 P16784 P167185 High Collapse 16/46 P169433 P167187 High Collapse 9μm 8/3 P164594 P16461 Viton Seals 16/46 P164598 P16463 Viton Seals ½ 1μm 8/3 P164166 P167186 High Collapse 16/46 P16417 P164367 Viton Seals P167188 HIgh Collapse 4 μm 8/3 P164365 Viton Seals 9 3μm 8/3 P164174 16/46 P164178 >5μm 8/3 P165319 74 ----/----/75 8/3 P1633 wiremesh screen Housing Choices Length Part (in./mm) No. 8/3 P16451 16/3 P1645 Note: Head assemblies include head-to-housing seal. Filter Notes SEALS: Filters with seals made of BunaN are appropriate for most applications involving petroleum oil. Filters with seals made of Viton (a fluoroelastomer) are required when using diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF (high water content fluids) over 15 F. (Viton is a registered trademark of DuPont Dow Elastomers.) SYNTHETIC MEDIA: Synteq filter media is compatible with petroleum based fluids, and most phosphate esters, water oil emulsions, and HWCF (high water content fluids.) Donaldson high collapse filters are physically designed to withstand up to 3 psi/,7 kpa before collapsing. Head Choices Port Size 4 Working Pressure Bypass Rating Indicators 1 Part No. 1½" SAE 4-Bolt Flange (code 61) and 3 psi 6 psi visual LH, blank plate RH P16617 SAE- O-Ring 1½" SAE 4-Bolt Flange (code 61) and 3 psi 9 psi with visual LH, blank plate RH P166149 SAE- O-Ring reverse flow check valve 1½" SAE 4-Bolt Flange (code 61) and 3 psi no bypass visual LH, blank plate RH P169754 SAE- O-Ring 1½" SAE 4-Bolt Flange 6 psi 6 psi visual LH only P164346 (code 6) 1½" SAE 4-Bolt Flange 6 psi 9 psi with visual LH, blank plate RH P1757 (code 6) reverse flow check valve 1¼" SAE 4-Bolt Flange 6 psi 9 psi with visual LH, blank plate RH P1758 (code 6) reverse flow check valve 1¼" SAE 4-Bolt Flange 6 psi 9 psi with blank plate LH, drilled, tapped, 3 P173887 (code 6) reverse flow check valve plugged RH for P17399 Head Notes On all HPK4 heads where an indicator is NOT installed, a blank plate or a plug is there. 1 Donaldson uses the inlet port as the reference point. Left side, for instance, means that the indicator mounts on the side of the filter head that is on your left when you face the inlet port. Alternate indicator: Electrical indicator (P16698) mounts in place of visual model on left side only. 3 Alternate indicator: Electrical indicator (P17399) mounts on right side of head only. 4 CAUTION: Consult fitting manufacturers for maximum allowable operating pressures. 9 Call 1-8-846-1846

HPK4 HPK4 Service Parts Visual Service Indicator (includes O-Ring & hardware) Max Temp: 18 F/83 C Set: 5 psi/345 kpa P164315 Normal Flow model P16663 Reverse Flow model P166134 Blank plate AC/DC Electrical Service Indicators P16698 (3-wire switch in conduit box, for left side of head only) Max Temp: 5 F/11 C Set: 4 psi/76 kpa Voltage: 1 VAC / 8 VDC Current: 5 ma Circuit: Normally open (red) normally closed (blue) common (white) O-Ring (Size 6) P161315 Viton Head Assemblies See Head Assembly Options table Head O-Ring & Back-up Kit (Size 4) P1674 BunaN O-Ring, Teflon back-up P163619 Viton O-Ring, Teflon back-up Replacement Filter Synteq media on all, except No. 74 which has Wiremesh media (listed in table on p. 9) Housing See housing assembly options table on page 9. O-Ring (Size 94) P161551 BunaN P163616 Viton - oil before assembling Performance Data Drain Plug Kit P16155 (with BunaN O-Ring) For a full explanation of how our performance curves were derived, see page 15. High Pressure Filters 3 HPK4 Housing Only 5 HPK4 16" Element Only PRESSURE DROP (PSID) 5 15 1 5 Reverse flow check valve standard flow direction Reverse flow check valve reverse flow direction No reverse flow check valve 1.5" ports No reverse flow check valve 1.5" ports REVERSE FLOW STANDARD FLOW 1.5" port PRESSURE DROP (PSID) 15 1 5 #1 # #.5 #9 4 6 8 FLOW (gpm) 1.5" port # 4 6 8 1 FLOW (gpm) HPK4 8" Element Only 3 #1 # PRESSURE DROP (PSID) 1 #.5 #9 # 4 6 8 1 FLOW (gpm) www.donaldson.com 91

gpm, 757 l/min HPK5 Highlights Working Pressures to: Rated Static Burst to: Flow Range to: 3 psi,7 kpa.6 bar 6 psi 41,4 kpa 413.8 bar gpm 757 l/min High Pressure Filters Features The HPK5 high pressure filter series is made of ductile iron for strength and durability. Machined bypass valves are case-hardened at critical points to provide maximum strength and reliability! Reverse flow bypass valve allows bi-directional flow through the filter head, with head up or head down mounting capabilities. Available with your choice of visual or AC/DC electrical service indicator; choose Viton or BunaN seals. The HPK5 filters contain Synteq, Donaldson s exclusive synthetic fiber media formulated especially for liquid filtration! Beta Rating Performance to ß 6(c) =1 T-Type Porting Sizes " SAE 4-Bolt Flange (code 61) Assembly Weight 63 lbs / 8.5 Replacement Filter Length 5.53"/648mm Standard Bypass Ratings 6 psi / 414 kpa / 4.1 bar with reverse- flow check valve No Bypass Operating Temperatures - F to 5 F / -9 C to 11 C Element Collapse Ratings psi / 138 kpa / 13.8 bar (standard) 3 psi /,7 kpa / 6.9 bar (high collapse) 9 Call 1-8-846-1846

HPK5 Assembly Side View for: High Pressure Circuits In-Plant & Mobile Equipment Hydrostatic Transmissions Centralized Lube Systems Head Top View With Visual Indicators Torque housind to 75 ft-lbs. With Visual & Electrical Indicators High Pressure Filters Bypass Valve Alternatives 6.81 3.65 3.6 INLET 6 psi /414 kpa Bypass Valve with Reverse Flow Check Valve BYPASS FLOW FILTERED FLOW OUTLET 7.88 3. O-RING BACK-UP RING 3 PSI BOLTED FLANGE CONNECTION " NOMINAL FLANGE SIZE NO BYPASS 1.688 1/-13UNC-B X 1.6 DEEP, 8 PLACES All dimensions above are shown in inches [millimeters] No Bypass www.donaldson.com 93

gpm, 757 l/min HPK5 Components Head Assemblies Port Bypass Indicator Assembly Media Element Size 4 Rating Style/Location 1 Number Number Part No. " SAE 4-Bolt Flange 6 psi / 414 kpa Visual, Left side K54 No. 9 P1649 (Code 61) Reverse flow check valve No Bypass Visual & Electrical 3 K539 No. 9 P17137 4 Assembly Notes 1 Donaldson uses the inlet port as the reference point. Left side, for instance, means that the indicator mounts on the side of the filter head that is on your left when you face the inlet port. Alternate choice: Electrical indicator (P16698) is available for mounting in place of the visual indicator on either side. 3 Visual indicator is mounted on left side of the head; electrical indicator (P17365) is mounted on the right side. 4 Rated as high collapse (3 psi / 7 kpa); has Viton seals. Synteq Element Choices Media Bx(c) = 1 Length Part Seal & Number Rating (in./mm) No. Comments High Pressure Filters No. 1 6μm 5.5 / 648 P167841 BunaN No. 9μm 5.5 / 648 P164585 BunaN No. ½ 1μm 5.5 / 648 P1647 BunaN P164435 Viton Built to order No. 9 3μm 5.5 / 648 P1649 BunaN P17137 Viton High Collapse Element Notes Filters with seals made of BunaN are appropriate for most applications involving petroleum oil. Filters with seals made of fluoroelastomer (such ad Viton or Fluorel ) are required when using diester, phosphate ester fluids, water glycol, water/oil emulsions, and HWCF (high water content fluids) over 15 F. (Viton is a registered trademark of DuPont Dow Elastomers and Fluorel is a registered trademark of the 3M Company.) Synteq filter media is compatible with petroleum based fluids, and most phosphate esters, water oil emulsions, and HWCF (high water content fluids). Donaldson high collapse filters, with their steel endcaps and reinforcing wire-backed media, are rated to withstand up to 3 psi /,7 kpa before collapsing. In this photo from our scanning electron microscope that shows Donaldson Synteq filter media magnified hundreds of times, you can see the rounded fibers that are specially designed for low resistance to flow. Filters made with Donaldson Synteq maintain low pressure drop over the life of the filter. 94 Call 1-8-846-1846

HPK5 HPK5 Service Parts Visual Service Indicator P164315 (includes O-Ring & hardware) Max Temp: 18 F/83 C Set: 5 psi/345 kpa or use blank plate P166134 O-Ring Size 6 P161315 Viton - o Head Assembly P165695 Reverse Flow Bypass Set Screw P1696 O-Ring & Back-Up Kit P1686 BunaN P1661 Viton AC/DC Electrical Service Indicator P16698 (shown) (3-wire switch in conduit box, for left side of head only) Max Temp: 5 F/11 C Set: 4 psi/76 kpa Voltage: 1 VAC / 8 VDC Current: 5 ma Circuit: Normally open (red) normally closed (blue) common (white) Housing P16485, 6" length Replacement Filter Synteq Filter Media Length 5.5" 648mm O-Ring & Back-Up Kit P1686 BunaN P1661 Viton - oil before assembling Performance Data For a full explanation of how our performance curves were derived, see page 15. 1 HPK5 Housing Only Cap Assembly P16866 (includes BunaN O-Ring and Back-Up Kit) O-Ring Size 94 P161551 BunaN P163616 Viton Drain Plug Kit P16155 (7/16- UNF SAE-4) HPK5 Housing with Standard Reverse Flow Valve 3 High Pressure Filters 8 5 PRESSURE DROP (PSID) 6 4 " Port PRESSURE DROP (PSID) 15 1 5 Reverse flow with " port Standard flow with " port 5 5 75 1 15 15 175 FLOW (gpm) HPK5 Element Only 15 #1 5 5 75 1 15 15 175 13 PRESSURE DROP (PSID) 1 8 5 3 # #4 #9 # 5 5 75 1 15 15 175 FLOW (gpm) www.donaldson.com 95