CNC Router Parts CNC Router Parts 2.2 kw Plug and Play Spindle / VFD System CRP800 Retrofit Guide

Similar documents
VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

Mitsubishi. VFD Manuals

VFD. Variable Frequency Drive

imach III P1A CNC Control Pendant

OEM TM-50 Quick Start Guide

Select a convenient position for the display on a panel or bulk head.

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

BX88175 Installation Instructions ToadStop II Vacuum Brake System

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Overview of operation modes

Introduction. Drenth Motorsport Gearboxes Fleuweweg AG Enter The Netherlands Phone: +31 (0) Fax: +31 (0)

Utilizing Kollmorgen Goldline Series Servo Motors with the AKD Drive

Your Legal Fuel Tank Source.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Subaru MY07 - MY15 STi/WRX Plug-in Manual

AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

DELCO AD Series Alternators

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

ADJUSTABLE FREQUENCY CRANE CONTROLS

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Motor Tuning Instructions

Induction Power Supplies

PLATINUM Series CAN WIDEBAND CONTROLLER WBC 1 & WBC 2 QUICK START GUIDE (HT & HT059980) Version 4

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Mega 475

SAISBM V36W Installation Instructions

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Paddle-wheel flow controller for On/Off control

Filtered PWM Speed Control for Permanent Magnet DC Motors

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

INSTALLATION INSTRUCTIONS

Congratulations on purchasing the epump solar pumping solution.

Positive displacement batch controller

Paddle-wheel flow controller for On/Off control

750 Paso Wiring Upgrade

Amp & Speaker Upgrade Install Instructions for Road Glide

Using the Gratec Gasoline software

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Installing the gate post bracket with the cardboard arm template

TL UNIVERSAL WIRING PROCEDURE

PULSE-8: MASTER PULSATION CONTROL

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

GM 6-Cylinder Cam Tool Set 3.0L and 3.2L Operating Instructions

TABLE OF CONTENTS YOUR MISTBOX S SERIAL NUMBER

MX150L ASSEMBLY INSTRUCTIONS

Installation Instructions for Foam Marker INTERMEDIATE also applies: JR, JR36

Flight Systems. Replacement for KASSEC DESCRIPTION

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

CENTRIFEEDER ELECTRONICS

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Paddle-wheel flow controller with optical principle for On/Off control

HP COOL TECH, INC. COOLANT PUMP. PowerPump. INSTALLATION MANUAL HANWHA XD20 Series 10000/11000

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Master Power Brakes Electric Vacuum Pump Kit Various Applications P/N: AC9001K

Model PM5000 Portable Milling Machine

In-Place-Inclinometer Installation Manual

ELITE 600

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Validator and Control Board Update Instructions for BC1

ELITE 625 With Dial Display Control

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

8D Series D38999 Stainless Steel Series

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

!" # )("*"+,$' 0*.!0&!&1* &23# 0 &*&.444#3# 0

CST F1 Pedals. Owner s Manual. (Adjustable Angle version)

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

Work Light Kit - Installation - Mini Mill - Toolroom Mill

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Cut zip ties and remove 2 plastic wiring harness brackets.

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

MODEL 396/398 ELECTRON BEAM SOURCE ROTARY CRUCIBLE INDEXER

PRSalpha Air Drill (Double Valve)

CX-SERIES ADVANCED BATTERY CHARGER

Application Note: SyMAX Permanent Magnet Motor Simple Startup Procedure

Insulated Crimp Terminals

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Part Number Analog Style 15 PSI Fuel/Boost Pressure Gauge. NOTE: Faceplate Configuration Instructions Included on Separate Sheet

Getting Started with the Digilent Electronics Explorer Board

Desktop 5.5 Z Axis Retrofit

Microgrid Storage Integration Battery modeling and advanced control

SP PRO KACO Managed AC Coupling


Lingenfelter ECSS-001 Ethanol Content Sensor Signal Simulator Installation & Operating Instructions

Crop Link Pump Control Wiring

FlexJet Carriage Circuit Board (PCB) Replacement

3. X-axis assembly. 3. X-axis assembly. X axis guide. Written By: Josef Prusa manual.prusa3d.com/ Page 1 of 14

If You Are Experiencing This, Click Thru:

perma STAR VARIO Operators pocket guide

!" # 0*.!0&!&1* &23# 0

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Installation Instructions. Manual # For Installing: Part # Painless Gauge Controller

Plug-In XEDE Installation (Version 1.2)

Model: AEM14 Analog Engine Monitor

TL UNIVERSAL WIRING GUIDELINE TRCM - J jan18jh

Water Valve Shutoff. WVS Water Valve Shutoff

TECHNICAL DOCUMENT. PCNC Mill Enclosure Door Switch Kit. Installation

Transcription:

Step 1: Congratulations on your purchase of the 2.2 kw Plug and Play Spindle / VFD System! The first step in setting up your Spindle will be to upgrade your current CRP800 Control Unit with VFD Compatibility. You should have received a 14 pin connector with your Retrofit Kit. (See below) This connector will be zip tied to separate out the 4 pins used for speed and fault signaling from the relay wiring. (See Below) 1

To install this 14 Pin connector, first remove the SP/THC port cover on your CRP800 Control Unit. (See below). Next install the 14 pin connector from the back side of the gland plate, with the square plastic flange inside of the Control Unit. (See below). 2

Now using the supplied #6-32 screws and nuts, secure the 14 pin connector to the gland plate. (See below). The 14 pin connector must now be wired to the break out board inside of the Control Unit. Install the four pin SUPU connector onto the break out board in the orientation and position shown below. 3

Then, install the Orange and Green quick disconnects on the 3 rd relay of the red break out board mounted to the gland plate (furthest to the left when facing down into the control unit, closest to the relay sockets on the gland plate). Note, you may have to crimp down on the QDCs to create a solid connection. Your CRP800 Control Unit is now ready to connect to the VFD via the grey 14 pin cable included with your Spindle and VFD Package. 4

Step 2: You may now physically connect your VFD to your CRP800 Control Unit with the supplied 14 pin cable. (See below). The 14 pin male-to-male cable should connect to the female 14 pin connectors on both the control box and the VFD as shown below. The included M23 cable should be used to connect your VFD to your spindle and the VFD power cable should be plugged into an appropriate L6-20 240 volt outlet. 5

The arrows on the M23 cable ends should align with the panel mount M23 receptacles on both the spindle and the VFD enclosure. If these arrows do not align, the cable will not make a functional connection (see below). 6

Step 3: Now that all physical connections are complete, you must modify the Mach3 settings on your PC to ensure proper spindle operation. Under Config select ports and pins, then select Motor Outputs Under the Motor Outputs tab, make the following changes to the Spindle row: Spindle Enabled must show a green check mark (click on the red X to change it to a green check) Step Pin set to 1 Dir Low Active must show a red X Step Low Active must show a red X Step Port set to 2 7

Now navigate to the Output Signals tab (Under Config select ports and pins, then select Output Signals ). Under the Output Signals tab make the following changes: In the Output #1 Row o Enabled must show a green check o Port must be set to 2 o Pin Number must be set to 17 o Active Low must show a green check In the Output #2 Row o Enabled must show a green check o Port must be set to 2 o Pin Number must be set to 16 o Active Low must show a green check In the Output #3 Row o Enabled must show a green check o Port must be set to 2 o Pin Number must be set to 14 o Active Low must show a green check 8

Now navigate to the Spindle Setup Tab (Under Config select ports and pins, then select Spindle Setup ). Under the Spindle Setup tab make the following changes: In Relay Control o CW M3 Output# must be 3 o CCW M4 Output# must be 3 In Flood Mist Control o Mist M7 Output# must be 2 o Flood M8 Output# must be 1 In Motor Control o Use Spindle motor Output must be checked o PWM Control must be checked o PWM Base Freq. must be 100 o Minimum PWM % MUST BE 0 In General Parameters o CW Delay Spin UP Should be 5 Seconds (or greater if you prefer a longer delay) 9

Now navigate to Pulley Selection (Under Config select Spindle Pulleys, then select Pulley Number 4 ) Under Pulley Settings make the following changes: Set Min Speed to 7980 Set Max Speed to 24000 Set Ratio to 1 10

Now navigate to Motor Tuning (Under Config select Motor Tuning then select the Spindle tab) Under the Spindle tab in Motor Tuning make the following changes: Set Steps Per to 1000 Set Velocity to 60 Set Acceleration to 200 Save Axis Settings and then hit OK 11

Now navigate to ESS Config (Under Plugin Control select ESS-XXXXX Config ) Under ESS Config make the following changes: Under spindle ensure the PWM box is checked Base Hz must be 100 12

With the above changes complete, you are now ready to run your Spindle with Mach3! Please read the below guidelines for operation of your spindle. When using your spindle, enter a speed between 8000 and 24000 into the Spindle Speed box. If you enter a value too low, it will bump to 7980, too high and it will bump to 24000. If you accidentally enter a value too low or high, hit reset twice to clear the Status. Once you have input a valid spindle speed, (not rpm or S-ov), Click the Spindle CW F5 button to turn the spindle on and run it at that speed. 13

If you experience any trouble while following this guide, please feel free to contact us at: support@cncrouterparts.com 14