Fixture Spec Sheet HFB3 Series 4/15/2011

Similar documents
Fixture Spec Sheet HFA2 Series 4/15/2011

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Highbay Fluorescent - Six Lamp Flat Profile Design

Highbay Fluorescent - Six Lamp Low Profile Design

Linear Fluorescent Lighting. Energy-Saving Lighting Systems

Vaporproof Strip - 4 Foot 1-3 Lamps

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

LED Stairwell Fixture

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

TCPHB4UNI1250K10 4' 12, 000 Lumen Unv Volt Led High Bay 5000K

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)


LED Flat Panel Luminaires

LED Flat Panel Luminaires

DESCRIPTION & APPLICATION

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

2 LED Designer Series

LED Flat Panel Luminaires

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

PHONE: (303) FAX: (970) WEBSITE:

LEN Series 2x2 / 2x4 LED

LED E-Series. we know light. LED Cents LED E-Series troffers gives you the appearance of fluorescent technology with a tube-like glow.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

PHONE: (303) FAX: (970) WEBSITE:

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

LED Black Housing High Output Remote Capable

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

Calibration Due Date Chroma Programmable AC Source 61604

LHBC Commercial-Grade High or Low Bay Luminaire

PDMHB Watt LED I-Beam High Bay

RLP Edge-Lit 2X2, 2X4, 1X4

Lumination LED Luminaires

Calibration Due Date Chroma Programmable AC Source 61604

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Test Sample Description Catalog Number: Description:

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u

Rail 4 RM4DI (Formerly Grande) LED. Pendant. Direct/Indirect

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

PART #: PROJECT: NOTES: APPROVAL SIGNATURE: Color Rendering (CRI) QTY Series

LHBIP LED High Bay High Performance

PHONE: (303) FAX: (970) WEBSITE:

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

HOME COMPANY LED PRODUCTS T5 PRODUCTS TECHNOLOGY FIND A REP FEATURED PROJECT PROJECTS LOGIN

LED INDOOR Lighting Guide

Lighting Tables for Existing/Base Equipment 4/15/2011

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Standard Grade 14 Inch Reflector. Ordering Information

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Applications. Illustrated Features

L CHTM. LCH Lensed LED Channel LED. Technical Specifications. LCH Lensed LED Channel Configuration. Project Catalog Number Type Date

PHONE: (303) FAX: (303) WEBSITE:

PROJECT INFORMATION. Catalog No.

Lighting Tables for Existing/Base Equipment 4/15/2011

HBL HIGH-BAY INDUSTRIAL LUMINAIRE

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

Lighting Tables for New Equipment 3/9/2016

Experience the Howard Advantage

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Electronic Fluorescent Ballasts

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

Metalux HB LED STANDARD EFFICACY

Model Size # Lamps Lamp Type Voltage Options RDI-C 2X MV. T5 Lamps 14= F14T5 24 = F24T5HO. T8 Lamps 17 = F17T8

Lighting Tables for New Equipment 2/24/2015

Lighting Systems Argus-7

Applications. Standard Materials

QCF IP65. LED Gas Canopy Fixture SPECIFICATIONS CERTIFICATION ORDERING INFORMATION EXAMPLE QCF-UL-60C-F-51K-GCO CERTIFIED

131 1 x 4. Lensed Static Troffer, Grid Mount FEATURES & SPECIFICATIONS ORDERING INFORMATION

Metalux HB LED STANDARD EFFICACY

SIRIUS ON/OFF SU OF50SUS PRODUCT SPECIFICATION PRODUCT DESCRIPTION CERTIFICATIONS & QUALIFICATIONS E DIMENSIONS. Tolerance Range : ± 10%

Lighting: Explosionproof Area HID. Applications. Standard Materials

Recessed. HP90 Fluorescent 1x4

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

Industrial. LED high bay FBX. 8000, 12,000, 16,000, 20,000, 24,000, 36,000 or 45,000 lms

NIPPO Seamlessline LED PRODUCT LISTING

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

DL2000. High Brightness 6 LED Downlight Module. Transforming Your Vision into Higher Performance Solutions. Overview

DRIVER OUTPUT F Fixed DM 0-10v Dimming 1 COLOR TEMP 51K 5100

Areamaster LED Flood/High Bay Luminaires

Metalux HB LED STANDARD EFFICACY

FVT / LED Vapor Tight

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Lighting Tables for Existing/Base Equipment 1/1/2014

Nema Head We light your world

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

FVH / LED Vapor Proof Highbay

Solid State T8 tube is the smart alternative to a

Micro-Bay 1 Lamp T8 Focus Beam 30. PSMH 400 Watt 30. I5 4 Lamp, T5HO 25. System Performance

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Example: RBX15L840-UNV-WT ARR22L. Family Lumens Color Temperature Voltage Finish Options Optics

T5 COOL BEAM FLUORESCENT HIGH BAY (6 LAMP FULL BODY SPECIFICATION GRADE) Up to 700 L. for T5 or T5HO (Blank) (Blank) Electronic Program Start

Transcription:

HIGH BAY FLUORESCENT FOUR LAMP DESCRIPTION HFB3 series high-bay fluorescent fixture is a great energy saving alternative to traditional HID high-bay fixtures. This fixture operates four lamps and as a standard feature comes equipped with Howard ballasts. Factory Installed Option J Benefits of fluorescent high-bay luminaries include: APPLICATIONS Warehouse Manufacturing facility Retail Store Gymnasium Cafeteria Auditorium LOWEST ENERGY Only 102 Watts! one EPL4/32IS/MV/MC Ballast and FOUR Howard F28T8 Lamps (7112 initial lumens) MOST LIGHT Only 240 Watts! two EP2/54HO/PRS/MV Ballasts and FOUR Howard F54T5/HO Lamps (17400 initial lumens) Energy Saving Compared to HID systems Exceptional Color Rendering High System Efficacy Long Lamp Life Instant On/Re-strike Capability Howard Ballast and Howard Lamp as a system is covered by Howard Industries Warranty Quality Lamp holders Computer Designed Reflectors System Tested, Designed, Approved, and Manufactured by Howard Industries in Mendenhall Mississippi. Compliant with Safety and performance standards. FEATURES Easy access to wiring compartment & ballast Access plate provides access to electrical wiring without the need to open the fixture Knock-outs for easy electrical wiring and assembly Factory Installed Occupancy Sensor option Factory Installed Emergency ballast option Lamp Installation option available Multiple power cord set options, (voltage, length, gage) Pendant mount kit provides a top J-box to simplify HID retrofit installations. Can be used with a hook or rigid conduit and fasteners (Fixture must be specified with J option) Choice of 86% Standard Specular Aluminum Reflector, 95% Specular Enhanced Aluminum Reflector or 91% White Reflector Heavy Duty pre-painted steel construction Custom configurations available Can be easily mounted by a single person Suspended or Pendant mounting insures a quick painless install Chain and V-Clip Hanging option Wire cable hanging option. Special wiring available upon request Reflector Assembly pivoted open after removal of 2 Screws Pendant mount option assembly Pendant Mount lances included only if Factory Installed Option J is selected

Ordering Information: Model Family Reflector/ Lens No. of Lamps Lamp Type/ Wattage CRI/CCT Ballast Input Volts Factory Installed Options Cord/Plug Description TBA Packaging HFB3 E 4 32 A HI MV 0CJ 06 0 I HFB3 A E: W: Standard specular aluminum (86%) Enhanced specular aluminum (95%) Reflective white (91%) 4 28: F28T8 30: F30T8 32: F32T8 54: F54T5HO A: B: C: D: E: F: G: H: I: J: K: L: M: N: CRI CCT High Lumen T5 T8 No lamps installed 75 3000 No x 75 3500 No x 75 4100 No x 75 5000 No x 85 3000 No x x 85 3500 No x x 85 4100 No x x 85 5000 No x x 85 6500 No x 85 3000 Yes x 85 3500 Yes x 85 4100 Yes x 85 5000 Yes x HI: LI: SI: HE LE SE PS: High BF Electronic Instant Start (T8 only) Low BF Electronic Instant Start (T8 only) Standard BF Electronic Instant Start (T8 only) High BF Electronic Instant Start CEE Listed High Efficiency (T8 only) Low BF Electronic Instant Start CEE Listed High Efficiency (T8 only) Standard BF Electronic Instant Start CEE Listed High Efficiency (T8 only) Programmed Start Electronic (T8 CEE Listed) (1) 02: 08: 09: MV: HV: AX: 120V 277V 347V 120-277V Universal 347-480v Universal (T5HO only) 480-477 Step-down autotransformer (2) 000: A: B: D: I: J: T: No factory installed options Occupancy sensor with extender arm (3) Emergency ballast (specify lumen requirement) Wrap Lens (7) Special wiring instructions J-Box (Pendant Mount) Configuration (5) Toggle switch bi-level lighting control (4) 00 Standard luminaire power disconnect (No Cord) TBA I: Single 01 6' SJT 18/3; no plug 02 10' SJT 18/3; no plug 03 6' SJT 18/3; L5-15 twist lock (120V) 04 10' SJT 18/3; L5-15 twist lock (120V) 05 6' SJT 18/3; 5-15 non twist lock(120v) 06 10' SJT 18/3; 5-15 non twist lock(120v) 07 6' SJT 18/3; L7-15 twist lock (277V) 08 10' SJT 18/3; L7-15 twist lock (277V) 09 6' SJT 18/3; 7-15 non twist lock(277v) 10 10' SJT 18/3; 7-15 non twist lock(277v) 11 16/3 no plug; specify length 12 6' SJT 16/4 16 16' SJT 18/3; 7-15 non twist lock(277v) 17 18/3 no plug; specify length 18 6' SJT 16/3; L8-20 twist lock (480v) 19 10' SJT 16/3; L8-20 twist lock (480v) X: Special 20 16' SJT 18/3; L5-15 twist lock (120V) Field Installed Options 21 16' SJT 18/3; L7-15 twist lock (277) 22 6' SJT 16/3; L7-20 twist lock(277v) HF-WCH HFB3-WG Wire cable hanging kit (2 pcs. Per kit) Wire Guard HF SK1 Stabilizer kit: Hub, collar and wire cable (6) HF 2CV HF 3CV 2' hanging chain & v-clips 3' hanging chain & v-clips 23 6' SJT 18/3; L6-15 twist lock (240V) 25 3' SJT 16/3; L8-20 twist lock (480v) 26 NEMA L6-20 6'L 240V CSET 27 NEMA L6-20 10'L 240V CS 28 20' SJT 16/3; L8-20 twist lock (480v) 29 14/3 no plug; specify length 30 10' SJT 18/3; L6-15 twist lock (240V) Sample Ordering Number HFB3 E 432H SI MV 000 06 0 I HFB3 Series Hi-Bay Fluorescent Enhanced Specular Aluminum 4 lamp design; F32T8/841 Lamps Standard Ballast Factor Ballast w/ Universal Input (120-to-277v) 000 no factory installed options 10' SJT 18/3; 5-15 non twist lock(120v) Individual Box Packaging 31 10' SJT 16/3; L7-20 twist lock(277v) 32 6' SJT 16/3; L5-20 twist lock (120V) 51 White 6' SJT 18/3; no plug 52 White 10' SJT 18/3; no plug Footnotes: 53 White 6' SJT 18/3; L5-15 twist lock (120V) (1) T8 Programmed Rapid Start recommended only in the case of abnormally frequent switching (as with an occupancy sensor). Instant Start T8 is appropriate for most ordinary applications. (2) Allows hook-up of standard MV ballast to 480V (3) Recommend use of programmed rapid start with occupancy sensor (4) Allows for separate control of two ballasts through simple toggling of a standard wall switch. Recommend use of programmed rapid start ballast with this control. (5) Unless otherwise specified, fixture will include field installed J-box. Supply wires will exit the center of the fixture, not the access plate. J-box can be installed without entering the fixture. (7) Standard Acrylic Prismatic, Pattern 12, 0.100 thick. Call for options.

Wire Cable Hanging Kit Pendant Mount Kit Our Fluorescent fixtures can be ordered with lamps installed. Call factory for details, availability and lead times. Stabilizer Kit Hanging Chain & V-clips Energy Cost $ En ergy Cost per Yea r $300 Existing System New System System Descriptions Hours burned per year Cost per kwh $ 400 Watt MH High Bay HFB3E432HSI High Ballast Factor Fluorescent Highbay 4368 Number of Fixtures 1 Number of Fixtures 1 0.12 Watts per Fixture (exiting system) (ballast input watts) 458 Watts per Fixture (new system) (ballast input watts) 108 $250 $200 $150 $100 7 6 % A nuua l S a v i ngs Energy Cost Estimation Energy used per yr. (existing system) $240 Energy used per yr. (new system) Potential Yearly Savings: $183 $57 $50 $0 $240 $57 Exis t ing S ys t e m N e w S ys t e m Howard Industries provides this tool to examine the potential impact of lighting decisions. This tool provides an ESTIMATE only. The analysis of this tool does not warrant or guarantee the actual costs or savings that will be realized as the analysis suggested. You can find the full version of this cost saving tool at the Howard Lighting Website www.howardlightingproducts.com. Click Cost of Ownership Calculator. Copyright (c) 2008 Howard Industries All Rights Reserved.

Photometric Data - 4 Lamp T8 (HFB3432) Candela Polar Graph Luminaire Efficiencies* Reflector Type T8 Enhanced Specular 90% Specular 84% White 85% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 2796.29 24.10 26.80 0-40 4443.61 38.30 42.60 HFB3E432 Test report: HFB3E432.IES Spacing Criteria (0-180): 1.28 Spacing Criteria (90-270): 1.12 Spacing Criteria (Diagonal): 1.30 Maximum Candela = 3798.24 Located at Horizontal Angle = 70, Vertical Angle = 5 1 Vertical Plane through Horizontal Angles (70-250) (Max Cd.) 2 Vertical Plane through Horizontal Angles (45-225) 3 Vertical Plane through Horizontal Angles (5) (Through Max. Cd.) 0-60 7633.57 65.80 73.20 0-90 10425.63 89.90 100.00 0-180 10425.63 89.90 100.00 Angle In Degrees LUMINANCE DATA (cd/sq.m) 0-Deg 45-Deg 90-Deg 45 7999 5689 5384 55 7517 5036 5938 65 6806 5279 5798 75 5619 4965 5566 85 2854 3142 3597 COEFFICIENTS OF UTILIZATION -ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 107 107 107 107 105 105 105 105 100 100 100 96 96 96 92 92 92 90 1 96 92 87 83 94 90 86 82 86 82 79 82 79 77 79 77 75 73 2 87 79 73 67 85 77 71 66 74 69 65 71 67 63 68 65 62 60 3 79 69 61 55 77 68 61 55 65 59 54 63 57 53 60 56 52 50 4 73 61 53 47 70 60 52 46 58 51 46 56 50 45 54 49 44 42 5 67 55 46 40 65 54 46 40 52 45 39 50 44 39 48 43 39 37 6 62 49 41 35 60 48 41 35 47 40 35 45 39 34 44 38 34 32 7 57 45 37 31 56 44 36 31 43 36 31 41 35 30 40 34 30 28 8 53 41 33 28 52 40 33 28 39 32 27 38 32 27 37 31 27 25 9 50 38 30 25 49 37 30 25 36 29 25 35 29 25 34 29 25 23 10 47 35 28 23 46 34 27 23 33 27 23 33 27 22 32 26 22 21

Photometric Data - 4 Lamp T5 (HFB3454) Candela Polar Graph Luminaire Efficiencies* Reflector Type T5 Enhanced Specular 93% Specular 88% White 88% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 5018.63 25.10 26.90 0-40 8217.01 41.10 44.00 HFB3E454 Test report: HFB3-454-MOD.IES Spacing Criteria (0-180): 1.26 Spacing Criteria (90-270): 1.30 Spacing Criteria (Diagonal): 1.40 Maximum Candela = 6505.34 Located at Horizontal Angle = 60, Vertical Angle = 10 1 Vertical Plane through Horizontal Angles (60-240) (Max Cd.) 2 Vertical Plane through Horizontal Angles (45-225) 3 Vertical Plane through Horizontal Angles (10) (Through Max. Cd.) 0-60 14314.51 71.60 76.60 0-90 18683.6 93.40 100.00 0-180 18683.6 93.40 100.00 Angle In Degrees LUMINANCE DATA (cd/sq.m) 0-Deg 45-Deg 90-Deg 45 15860 15289 14862 55 14682 13909 12227 65 13288 11505 13835 75 11396 12493 12773 85 9001 7421 7403 COEFFICIENTS OF UTILIZATION -ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 111 111 111 111 109 109 109 109 104 104 104 99 99 99 95 95 95 93 1 101 96 92 88 98 94 90 87 90 87 84 84 86 81 83 81 79 77 2 92 84 77 71 89 82 76 70 78 73 69 75 71 67 72 69 66 64 3 83 73 65 59 81 72 64 59 69 63 58 66 61 57 64 59 56 53 4 76 65 56 50 74 64 56 50 61 54 49 59 53 48 57 52 48 46 5 70 58 49 43 68 57 49 43 55 48 42 53 47 42 51 46 41 39 6 65 52 44 38 63 51 43 37 50 42 37 48 42 37 46 41 36 34 7 60 47 39 33 58 47 39 33 45 38 33 44 37 33 42 37 32 30 8 56 43 35 30 54 42 35 29 41 34 29 40 34 29 39 33 29 27 9 52 40 32 27 51 39 32 27 38 31 26 37 31 26 36 30 26 24 10 49 37 29 24 48 36 29 24 35 28 24 34 28 24 33 28 24 22