BODYGUARD 323 AMBULATORY INFUSION PUMP

Similar documents
BODYGUARD 595 REGIONAL ANALGESIA INFUSION PUMP

Dedicated, ambulatory nerve block and wound infiltration treatment

Syringe Infusion Solutions

Syringe Infusion Solutions

Pain Management Solutions

Multi Therapy Solutions

Multi Therapy Solutions

Pain Management Solutions

CADD -Solis VIP Ambulatory Infusion Pump Model 2120

BodyGuard 121 Twins Infusion System Operator Manual

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

CADD Ambulatory Infusion Systems

BodyGuard 323 Infusion Pump System Operator Manual

BodyGuard 323 Infusion Pump System Operator Manual

CADD Amulatory Ambulatory Infusion Systems CADD. Ordering Information. CADD Tubing Sets with Flow Stop Free-Flow Protection.

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

CADD Ambulatory Infusion Systems

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

Syringe Driver Introduction. Christine Hull & Anita Webb Staff Nurses, Hospice in the Home 2015

Nimbus Flex Ambulatory Infusion Pump

Quick Reference Guide

Patient s Manual for Using Nimbus Ambulatory Pump for Continuous Peripheral Nerve Block Application

Accumate 2300 Volumetric Infusion Pump

Ambulatory Syringe Pump Operation Manual

Deltec 3000 and Deltec Micro 3100 Large Volume Infusion Pumps Modular Infusion System

CADD-TPN. Model 5700 Operator s Manual. Deltec. Ambulatory Infusion System. SIMS Deltec, Inc., St. Paul, MN U.S.A.

Operator s Manual. spectrum 35700BAX & 35700ABB. Generation 2 Operating System Pump Operating Software v6.05 For Use with MDL Editor v6.2.

NIKI T34 pump. Knowing your way around the NIKI T34 pump

CADD-Solis Infusion Pump

Instruction for Use (IFU)

Companion. Enteral Nutrition Pump. Operating Manual. For Enteral Use Only Not for IV Use NOTES. No Purchase No.

Light / Vario Basal Mode

CADD -Solis VIP Ambulatory Infusion Pump. Technical Manual Model 2120

CRONO S-PID 50 Ambulatory infusion pump

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

Cole-Parmer Pro-Spense

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Companion. Enteral Pump. Operating Manual. For Enteral Use Only Not for IV Use

Operator Manual of Guangzhou Huaxi Medical Technology Co., Ltd. JORVET INFUSION PUMP J1060 OPERATOR MANUAL

CADD-Prizm PCS II. Operator's Manual. Ambulatory Infusion Pump. Model 6101

Ambulatory. Infusion. Pumps

Technical specifications

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

For detailed instructions, specifications, warnings, warranties, and additional information on operating the CADD -Solis ambulatory infusion pump,

CADD-PCA. Model 5800R Operator s Manual. Deltec. Ambulatory Infusion Pump. SIMS Deltec, Inc., St. Paul, MN U.S.A.

Actuator systems for hospital beds Perfection in movement LINAK.COM/MEDLINE-CARELINE

for Kids Infusion Therapy Products for Neonatal and Pediatric Patients

INTECH Micro 2300-RTD6

LIST OF FIGURES... ii. LIST OF WARNINGS and CAUTIONS... iii CHAPTER 1 - GENERAL INFORMATION... 1 CHAPTER 2 - DIRECTIONS FOR USE...

O p e r a t o r ' s M a n u a l

FLEXIFLO Companion. Enteral Nutrition Pump OPERATING MANUAL

S1-568, S1-1068, S1-1568

Hand-Held Pressure Measuring Instrument "Manoport"

Going home with a CADD Pump - Chemotherapy Medication

Hoyer Elara The illuminating solution for your ceiling lift needs.

CADD-1. Model 5100 HFX Operator s Manual. Note: Colors are Black and Cyan (as second color) Deltec. Ambulatory Infusion Pump

CADD-Legacy 1 Ambulatory Infusion Pump Model 6400

Owners Manual for TPMS plus GPS

Laerdal Compact Suction Unit 4

PRODUCT CODE: 2M8153, 2M8153K

Pro. BeneHeart D1 Defibrillator

Syringe Pump. Model:SK-500II Instruction Manual. Shenzhen Shenke Medical Instrument Technical Development Co., Ltd.

2-BP Set: 1-Automatic counting chamber: 3-Pneumatic tourniquet small and adult: Adult cuff (22-32 cm upper limb size

OPERATOR S MANUAL. Ambulatory Infusion Pump Model 6300 PATIENT CONTROLLED ANALGESIA

MED-HUB E and Transfer Cart

Urgent Field Safety Notice

MGE TM Galaxy TM 7000 GFC

CRONO TWIN. Ambulatory infusion pump USER MANUAL

U S E R M A N U A L SAVE THESE INSTRUCTIONS

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

ReadStar & CapStar Range Torque Readouts & Torque Testers. Crane Electronics Inc The force in torque management

SR7 Micro-infusion Syringe Pump. Contents

Handheld Micro Ohmmeters RMO-H series

Battery Li-Ion BA21. Data sheet LINAK.COM/MEDLINE-CARELINE

Portable pressure calibrator, Wally Box III Model CPH7600

FEATURES AND BENEFITS

DGC-2020 DIGITAL GENSET CONTROLLER

Pressure Transmitter

» Sophisticated» Reliable» Intelligent

Eickemeyer Operating Manual Syringe Pump "Advanced"

Don t get caught out by the Sharps Directive

Portable TOC Analyser for Stack Emissions

Operator Instructions for Tension Links

FIRST FOR PORTABLE PARTICLE COUNTING

MGE TM Galaxy TM 7000

Benchmark. Pulsatile Pump PD Medical Device Testing & Equipment Simulation Platforms Silicone Vessels

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

PR1000ELCD / PR1500ELCD User s Manual

Language specific user manuals are available on

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

OMNI EXPRESS PORTABLE PATIENT MONITOR

Intermittent Delivery Mode

Defender 3000 Series Base Instruction Manual

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

COUNTIS E22 Three-phase energy meter Direct - 80 A

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Transcription:

BODYGUARD 323 AMBULATORY INFUSION PUMP The BodyGuard 323 Ambulatory Infusion Pump is a multi-therapy pump suitable for the hospital and homecare environments with three programmable modes (TPN, continuous and step).

Main Features: The piston pump mechanism ensures unparalleled accuracy and linearity of infusion, even at lowest rates to meet the standards of the most demanding specialities Configurable modes of operation which can be set to a speciality or patients understanding TPN, continuous and step Adjustable air-in-line detection. The cumulative ultrasonic counter can be set according to local protocols Variable occlusion pressure settings, configurable to the route of infusion/ patient type Lightweight and compact, suitable for both bedside and ambulatory use A delayed start infusion option means no reminder and no additional clinical intervention needed once pump has been set up for general infusion Designed to be intuitive to program and use Automatic occlusion alarm cancelling and infusion restart on resolution of inadvertent simple line kinking episodes

Features and Applications Safety Features: Built-in event log automatically records accurate and reliable data on pump use Lockable keypad to prevent inadvertent key presses Fixed or variable code protected programmes that are configured and locked into the pump memory and can only be accessed by authorised personnel or technicians Post Occlusion Bolus Reduction System will safely release pressure from the line, following an occlusion, without administering a post occlusion bolus Pump event log accessible via INFO MENU or downloaded to PC through BodyComm software Modes of Operation: Parenteral nutrition (PN) Continuous Step

Intended Use: The BodyGuard 323 TM Infusion Pump System is designed for infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including but not limited to: Intravenous Subcutaneous Percutaneous Intra-arterial Common Applications: Parenteral nutrition (PN) Maintenence of general fluids or medication Speak to our team who have the knowledge and experience to support you in choosing the right medical infusion products to meet your requirements.

Accessories and Consumables Accessories Carry Pouch 100ml Carry Pouch 250ml/500ml Blue 3 Litre Rucksack Black 2 Litre Rucksack Grey 2 Litre Rucksack Pink 2 Litre Rucksack Battery Cell X2 9V Battery Charging Cable (DC Cable) External Battery Charger Charger LED and DC Charger - No Display Standard Life Battery 1800mAh Extended Life Battery 3600mAh 13A Plug Lead 1.8m (Straight) BodyComm Kit UK Wall Charger - 8.2V

The BodyGuard 323 TM Ambulatory Infusion Pump has a range of dedicated administration sets. These are 1.2 and 0.2 micron filter with optional manual priming valve. All sets are non-dehp 1 PVC plasticized with TOTM 2, are BSE-TSE 3 free, latex free and EVA 4 free. Length and priming volume are approximate. For more information on administration sets or for product codes, please visit our website; cmemedical.co.uk. You can also contact our Customer Support team on 01253 206700 or email customersupport@cmemedical.co.uk References 1. Bis(2-ethylhexyl) phthalate, 2. Tris (2-Ethylhexyl) Trimellitate, 3. Bovine spongiform encephalopathy, 4. Ethylene-vinyl acetate.

Ongoing Support Clinical Support Network We cover the UK and work in partnership with healthcare providers to help ensure successful pump conversions and deliver device user training programmes. All our Clinical Support Specialists have backgrounds in areas such as critical care, pain management, theatre and recovery, community and palliative care. Technical Support Our Technical Support team comprises of experienced medtech engineers who ensure quality servicing, maintenance and repair of our products. Please contact our team to discuss the different levels of service support available to best suit your needs. Quality Assurance and Regulatory Support Our team of experienced Quality Assurance professionals can resolve customer complaints, conduct first line testing (in conjunction with our Technical Support team), whilst managing relations with local regulatory bodies, supplier and quality audits and regulatory approvals.

Regional Field Sales Support When you want to make informed choices about which products will meet the needs of your service and patients, our team has the knowledge and experience to talk to you, wherever you are in the UK or Ireland. Customer Support Whether you are a clinician, an engineer or a patient using CME Medical products or services, our team of experienced customer support professionals are available to deal with your enquiry.

Technical Specification Device type Flow rate Priming rate Total infused volume Piston mechanism, ambulatory infusion pump with a single channel 0.1ml/hr to 100ml/hr in 0.1ml/hr increments and 100ml/hr to 1,200ml/hr in 1ml/hr increments 100ml/hr to 1,200ml/hr in 1ml/hr increments 0.1ml to 1,000ml Pump accuracy +/- 5% KVO rate Air sensor Maximum pressure Power supply Battery Battery operation at 125 ml/hr Battery charging Alarms Dimensions 0ml/hr to 50 ml/hr Ultrasonic, adjustable air bubble size +/-155mmHg (+/-3psi) AC mains power Rechargeable, Li-Polymer, 7.4V, 1800mAh (typical) 11.3 hours (average) infusing @ 350ml/hr Battery charging commences automatically when the pump is mounted into the charger unit (docking station) that is connected to an AC Mains source. (LED confirmation of AC Mains connected) Air/upstream occlusion, down occlusion, door open, pump paused too long (un-attended), end program, end battery, missing key, restart pump, system/technical problem, wrong TPN data, lock mode, fatal error 112mm x 89mm x 32mm

Classification Housing Weight Electrical safety Standards EMC Environmental specifications Temperature Humidity Air pressure Operating conditions Temperature Humidity Air pressure Type CF Equipment, degree of protection against electrical shock class II equipment, IPX3 protection against ingress of water ABS (fire retardant) 397g (with battery) Complies with EN 60601-1 (Medical Electrical Equipment Safety), IEC 60601-2-24 (Infusion pumps and controllers), IEC 60601-1-4 (Programmable Electrical Medical System) Manufactured in accordance with ISO 9001;2008 and ISO 13485;2003. CE marked (In accordance with the Medical Devices Directive 93/42/EEC) The BodyGuard Infusion System is designed to be in compliance with EN 60601-1 (safety) and IEC 601-1-2 (EMC) Non operating conditions (transportation and storage): -25 C to +50 C (-13 F to +122 F) 5% to 100% R.H., non-condensing 48kPa to 110kPa The system may not meet all performance specifications if operated outside of the following conditions: +18 C to +45 C (+59 F to +113 F) 20% to 90% R.H. at +40 C, non-condensing 70kPa to 110kPa

CME Medical UK Limited Kincraig Business Park Kincraig Road Blackpool FY2 0PJ Tel: 01253 206700 Fax: 01253 896648 Email: customersupport@cmemedical.co.uk cmemedical.co.uk Say hello! Ref: MD001