NH DIN Dual Indication Fuse Links

Similar documents
NH DIN Dual Indication Fuse Links

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

General Purpose IEC Fuses

Leadership in Circuit Protection

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

Leadership in Circuit Protection

500 Volts gg/gl NH Fuse links

Utilisation category gl/gg 500VAC with combi indicator

MEDIUM VOLTAGE DIN Fuse-Links

Bussmann 7.2 kv Medium voltage fuse links

Low voltage NH knife-blade fuse-links

NH Dual NHIndicator Fuse System Fuse System

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

DIN Dual indication fuse links

Safety switches for hinged doors

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Limitor -G General Purpose Fuses

NH LOW VOLTAGE a FUSE SYSTEM

Bussmann series NH catalogue. Leadership in circuit protection

Product family. D type fuse-links

MEDIUM VOLTAGE DIN Fuse-Links

Single foot switches PX and PA series

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

XL Photovoltaic fuse links

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

NH (H.R.C) FUSES AND FUSE BASES

Protistor size 70 gr 690VAC (IEC)

NEOZED D0 fuse-links gg 400/440VAC

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Control switch/load disconnect switch Series 8008

LINOCUR Size D02 63A 230VAC/440VAC

TMC 91H is now TMC 60 C Series

Glass fuse 16x5 mm time lag. Number Amp. Number Amp.

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Bussmann series NH bases

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Safety switches for hinged doors

500 and 690 V a.c. am NH fuse links

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

MULTIFIX 60 Universal Bus Bar Carriers

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Prewired position switches FF series

34-SDMS-02 SPECIFICATIONS FOR

Medium Voltage current limiting Fuse links

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Special Purpose Fuses

Medium Voltage current limiting Fuse links

IGS-EL-002(0) National Iranian Gas Co. Research and Technology Management. Standardization Division IGS. Iranian Gas Standards.

D & D0 LOW VOLTAGE FUSE SYSTEM

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole


6-0. Product family. LV HRC strip-fuseways

FL series position switches

NH Bases BUSSMANN SERIES. Technical Data Product description. Standard features

Safety rope switch without reset for simple stop

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

International products

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Safety rope switches with reset for emergency stop

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Prewired position switches FF series

SAFECLIP. Applications. Technical Data. Approvals ASTA Certified. Performance. Application Notes. Features. Associated Fusegear Equipment

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

BETA Switching Switches and Light Indicators

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Solenoid System FLANGE MOUNTING VERSION

Safety rope switch with reset for emergency stop

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

IEC and British Standard Fuses.

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

BETA Fuses and Fuse Systems

Motor Circuit Breakers C4

General_technical_data Series

Controls HIGH SPEED FUSES

EMO-21. Specifications. Elcom International Pvt. Ltd. Approvals: Screw mounting IEC outlet. Terminals: 6.3 mm Quick Disconnect Tabs.

Standardized fuse characteristics

2013 JEAN MÜLLER Products

fuse-links & fuse holders PHOTOVOLTAIC

Transcription:

Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide variety of applications. All fuse links are packed in 3 s. CATALOGUE SYMBOL: (amp)g(size)b HRC FUSE LINKS CLASS OF OPERATION gl/gg 500V AC 10 to 630 AMPS SIZES 000 to 3 Technical Data: : 500V AC Breaking Capacity: 120kA Frequency: 50Hz Operating Frequency: 45-62 Hz Design -Insulator: Steatite -Metal s: Corrosion-proof (aluminium) Contact Blade: Full contact blades, Silver plated copper Dimensional Data Size a a1 a2 (max) a3 a4 b (nom) c1(± 8) c2 (nom) D (nom) e1 (max) e2 (max) e3 (max) e4 (nom) f (max) 000 78.5 ± 1.5 54 45 ± 1.5 49 ± 1.5 15.1 35 9.5 2 48 30 20 6 15 00 78.5 ± 1.5 54 45 ± 1.5 68 ± 1.5 15.1 35 9.5 2.5 48 30 20 6 15 0 125 ± 2.5 68 62 ± 2.5 68 ± 2.5 15.1 35 9.5 2.5 48 40 25 6 15 01 &1 135 ± 2.5 75 62 ± 2.5 68 ± 2.5 20.1 40 9.5 2.5 53 52 25 6 15 02 & 2 150 ± 2.5 75 62 ± 2.5 68 ± 2.5 25.1 48 9.5 2.5 61 60 25 6 15 03 & 3 150 ± 3 75 62 ± 2.5 68 ± 2.5 32.1 60 9.5 2.5/3 76 75 25 6 15 Form No. Page 1 of 8

Class of Operation gl/gg, 500V AC, 10 to 100 s Sizes 000 Time Current Characteristics for Size 000 Size 000 Details: Standards/Approvals: IEC60269, DIN 43 620, VDE0636 Currents: 10, 16, 20, 25, 32, 35, 40, 50, 63, 80 & 100 s I 2 t(ere 2 seconds) 10G000B 10 58 290 232 1.5 16G000B 16 234 1170 1000 2.3 20G000B 20 584 3000 2400 2.2 25G000B 25 1000 4600 3700 2.8 32G000B 32 2400 11800 9400 3.7 35G000B 35 2400 11800 9400 3.7 40G000B 40 3300 16500 13200 4.0 50G000B 50 5600 27800 16700 4.9 63G000B 63 6300 24900 18700 4.5 80G000B 80 9800 38900 29200 6.3 100G000B 100 18100 72300 54300 7.4 0.119 kg 500Vac Form No. Page 2 of 8

Class of Operation gl/gg, 500V AC, 125 & 160 s Sizes 00 Time Current Characteristics for Size 00 Size 00 Details: Standards/Approvals: Currents: IEC60269, DIN 43 620, VDE0636 125 & 160 s I 2 t(ere 2 seconds) 125G00B 125 25000 125000 80000 10.0 160G00B 160 62000 310000 204600 10.0 0.185 kg 500Vac Form No. Page 3 of 8

Class of Operation gl/gg, 500V AC, 10 to 160 s Sizes 0 Time Current Characteristics for Size 0 Size 0 Details: Standards/Approvals: IEC60269, DIN 43 620, VDE0636 Currents: 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125 & 160 s I 2 t(ere 2 seconds) 10G0B 10 58 290 240 1.7 16G0B 16 240 1200 1000 3.0 20G0B 20 490 2500 2000 3.2 25G0B 25 1200 5600 4500 3.2 32G0B 32 1800 9000 7200 4.8 35G0B 35 2400 11800 9400 4.4 40G0B 40 3300 16500 13200 4.7 50G0B 50 5600 22300 16700 6.3 63G0B 63 6600 26100 19600 5.6 80G0B 80 9800 38900 29200 7.1 100G0B 100 20600 82300 61700 7.5 125G0B 125 25000 125000 72500 10.0 160G0B 160 62000 310000 179800 11.5 0.251kg 500Vac Form No. Page 4 of 8

Class of Operation gl/gg, 500V AC, 10 to 250 s Sizes 01 & 1 Time Current Characteristics for Size 01 & 1 Size 01 & 1 Details: Standards/Approvals: IEC60269, DIN 43 620, VDE0636 Currents: 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160, 200, 224 & 250 s I 2 t(ere 2 seconds) 10G01B 10 58 300 300 2.0 16G01B 16 240 1200 1000 3.0 20G01B 20 490 2500 2000 3.2 25G01B 25 1200 5600 4500 3.2 32G01B 32 1800 9000 7200 4.8 35G01B 35 2400 11800 9400 4.6 40G01B 40 3300 16500 13200 5.0 50G01B 50 5600 22300 16700 6.7 63G01B 63 6600 26100 19600 5.6 80G01B 80 9800 38900 29200 7.1 100G01B 100 20600 82300 61700 7.7 125G01B 125 25000 125000 72500 11.6 160G01B 160 62000 310000 179800 12.3 200G1B 200 97000 368600 291000 15.0 224G1B 224 124000 471200 372000 15.0 250G1B 250 151300 574900 453800 19.0 0.269kg 0.387kg 500Vac Form No. Page 5 of 8

Class of Operation gl/gg, 500V AC, 35 to 400 s Sizes 02 & 2 Time Current Characteristics for Size 02 & 2 Size 02 &2 Details: Standards/Approvals: IEC60269, DIN 43 620, VDE0636 Currents: 35, 40, 50, 63, 80, 100, 125, 160, 200, 224, 250, 315, 355 & 400 s I 2 t(ere 2 seconds) 35G02B 35 2400 11800 9400 4.4 40G02B 40 3300 16500 13200 5.0 50G02B 50 5600 22300 16700 6.4 63G02B 63 6600 26100 19600 6.0 80G02B 80 9800 38900 29200 7.0 100G02B 100 20600 82300 61700 8.0 125G02B 125 25000 100000 72500 12.0 160G02B 160 62000 248000 179800 12.0 200G02B 200 96900 367900 290500 15.0 224G02B 224 124000 472000 372000 15.0 250G02B 250 151300 574900 453800 19.0 315G2B 315 361700 1446500 940300 21.0 355G2B 355 446500 1785800 1160800 27.0 400G2B 400 642900 2571500 1671500 29.0 0.402kg 0.630kg 500Vac Form No. Page 6 of 8

Class of Operation gl/gg, 500V AC, 250 to 630 s Sizes 03 & 3 Time Current Characteristics for Size 03 & 3 Size 03 & 3 Details: Standards/Approvals: Currents: IEC60269, DIN 43 620, VDE0636 250, 315, 355, 400, 500 and 630 s I 2 t(ere 2 seconds) 250G03B 250 160800 642900 417900 20.0 315G03B 315 361700 1446500 940300 21.0 355G03B 355 446500 1785800 1160800 27.0 400G03B 400 642900 2571500 1671500 29.0 500G3B 500 886000 3898400 2923800 37.0 630G3B 630 1590000 6996000 5406000 46.0 0.634kg 1.043kg 500Vac Form No. Page 7 of 8

Class of Operation gl/gg, 500V AC, 10 to 630 s Cut off Current Characteristics Size 000 to 3 Details: Standards/Approvals: IEC60269, DIN 43 620, VDE0636 1 Currents: 10 to 630 amps Form No. Page 8 of 8