DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Similar documents
Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

AF40... AF96 3-pole contactors Technical data

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Electronic overload relay EF65, EF96 and EF146

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Electronic overload relays EF205 and EF370

AF series contactors (9 2650)

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF65 and TF96

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

CA Z-EN Overload relays, CT-operated overload relays

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF series contactors (9 2650)

Thermal overload relay TF140DU and TF140DU-V1000

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Modular contactor for installation into distribution boards

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal Overload Relays

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

ASL09..S 3-pole Contactors - Spring Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

B Mini Contactor V Hz

AE 9... AE 40 Contactors NE... Contactor Relays

Technical Information

C E R T I F I C A T E O F C O M P L I A N C E

MS General Information Extended Product Type: MS

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

BETA Switching Switches and Light Indicators

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Short form catalogue. Motor protection & control

For Info: Phone: Fax:

Micro Contactor MA Series

Technical data for manual motor starters Type MS325

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Description. Positive safety relays

TAE pole Contactors

IEC CONTACTORS AND OVERLOAD RELAYS

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

SIRIUS 3RU2 Thermal Overload Relays

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Technical Information

Bulletin 193-T1 Bimetallic Overload Relays

Solid State Relays, 3-phase

Technical Information

4 - Miniature controls

BC Mini Contactor VDC

Industrial Contactors CTX 3 3P 185A - 800A

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Mini contactors B6, BC6 with 3 pole

Electrical sector solutions E Line family. Industry leading design in a compact package

MS25, MST25, MS20, MST20

Series KTU7 UL489 Molded Case Circuit Breakers

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Flexible. Intelligent. Trendsetting.

Electrical sector solutions E Line family. Industry leading design in a compact package

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Selection Guide Motor Control Device Solutions

CI-TI Contactors and Motor Starters Type CI 6-50

C E R T I F I C A T E O F C O M P L I A N C E

Transcription:

DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical DC operated Operations x 10 6 10 Operating frequency, mechanical DC operated Operations/h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +60 Enclosed C - 25-40 Storage C - 40-80 Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Main contacts N/O contact g 10 Auxiliary contacts N/O contact g 7 N/C contact g 5 Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted Half-sinusoidal shock, 10 ms Main contacts N/O contact g 5.7 Auxiliary contacts N/O contact g 3.4 N/C contact g 3.4 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight DC operated kg 0.29 Spring-loaded terminal connection Terminal capacity main cable Solid 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) flexible 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) flexible with ferrules 2 mm 1 x (0.75-1.5) 2 x (0.75-1.5) Solid or stranded AWG 18-14 Stripping length mm 10 Terminal capacity control circuit cables Solid 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) 07/31/2018 Eaton 277468 ED2018 V46.0 EN 1 / 12

Tool Flexible 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) Flexible with ferrule 2 mm 1 x (0.75-1.5) 2 x (0.75-1.5) Solid or stranded AWG 18-14 Stripping length mm 10 Screwdriver blade width mm 3.5 Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to EN 61140 between coil and contacts V AC 400 between the contacts V AC 400 Making capacity (p.f. to IEC/EN 60947) Breaking capacity Up to 690 V A 126 220 V 230 V A 90 380 V 400 V A 90 500 V A 70 660 V 690 V A 50 Short-circuit rating Short-circuit protection maximum fuse Type 2 coordination 400 V gg/gl 500 V A 20 690 V gg/gl 690 V A 16 Type 1 coordination 400 V gg/gl 500 V A 35 AC AC-1 690 V gg/gl 690 V A 20 Rated operational current Conventional free air thermal current, 3 pole, 50-60 Hz Open at 40 C I th =I e A 22 at 50 C I th =I e A 21 at 55 C I th =I e A 21 at 60 C I th =I e A 20 enclosed I th A 18 Conventional free air thermal current, 1 pole open I th A 50 enclosed I th A 45 AC-3 Rated operational current Open, 3-pole: 50 60 Hz 220 V 230 V I e A 9 240 V I e A 9 380 V 400 V I e A 9 415 V I e A 9 440V I e A 9 500 V I e A 7 660 V 690 V I e A 5 380 V 400 V I e A 9 07/31/2018 Eaton 277468 ED2018 V46.0 EN 2 / 12

AC-4 DC Motor rating P kwh 220 V 230 V P kw 2.5 240V P kw 3 380 V 400 V P kw 4 415 V P kw 5.5 440 V P kw 5.5 500 V P kw 4.5 660 V 690 V P kw 4.5 Open, 3-pole: 50 60 Hz 220 V 230 V I e A 6 240 V I e A 6 380 V 400 V I e A 6 415 V I e A 6 440 V I e A 6 500 V I e A 5 660 V 690 V I e A 4.5 Motor rating P kwh 220 V 230 V P kw 1.5 240 V P kw 1.6 380 V 400 V P kw 2.5 415 V P kw 2.8 440 V P kw 3 500 V P kw 2.8 660 V 690 V P kw 3.6 Rated operational current, open DC-1 60 V I e A 20 110 V I e A 20 220 V I e A 15 Current heat loss 3 pole, at I th (60 ) W 4.4 Current heat loss at I e to AC-3/400 V W 0.9 Impedance per pole mω 4.6 Magnet systems Voltage tolerance DC operated Pick-up x U c 0.8-1.1 Notes 0.85-1.1 only with auxiliary contact module with 3 or more N/C contacts 0.7 1.3 without auxiliary contact module and at ambient air temperature + +40 C DC operated Drop-out x U c 0.15-0.6 Notes at least smoothed two-phase bridge rectifier or three-phase rectifier Power consumption of the coil in a cold state and 1.0 x U S DC operated Pick-up W 4.5 DC operated Sealing W 4.5 Duty factor % DF 100 Changeover time at 100 % U S (recommended value) Main contacts DC operated ms Closing delay ms 31 Opening delay ms 12 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference according to EN 60947-1 Interference immunity according to EN 60947-1 07/31/2018 Eaton 277468 ED2018 V46.0 EN 3 / 12

Rating data for approved types Switching capacity Maximum motor rating Three-phase 200 V 208 V 230 V 240 V 460 V 480 V 575 V 600 V HP 3 HP 3 HP 5 HP 7.5 Single-phase 115 V 120 V 230 V 240 V HP 0.5 HP 1.5 General use A 20 Auxiliary contacts Pilot Duty AC operated A600 DC operated P300 General Use AC V 600 AC A 10 DC V 250 DC A 1 Short Circuit Current Rating SCCR Basic Rating SCCR ka 5 max. Fuse A 45 max. CB A 60 480 V High Fault SCCR (fuse) ka 30/100 max. Fuse A 25 Class RK5/20 Class J SCCR (CB) ka 65 max. CB A 16 600 V High Fault SCCR (fuse) ka 30/100 max. Fuse A 25 Class RK5/20 Class J Special Purpose Ratings Electrical Discharge Lamps (Ballast) 480V 60Hz 3phase, 277V 60Hz 1phase A 18 600V 60Hz 3phase, 347V 60Hz 1phase A 18 Incandescent Lamps (Tungsten) 480V 60Hz 3phase, 277V 60Hz 1phase A 14 600V 60Hz 3phase, 347V 60Hz 1phase A 14 Resistance Air Heating 480V 60Hz 3phase, 277V 60Hz 1phase A 18 600V 60Hz 3phase, 347V 60Hz 1phase A 18 Refrigeration Control (CSA only) LRA 480V 60Hz 3phase A 60 FLA 480V 60Hz 3phase A 10 LRA 600V 60Hz 3phase A 60 FLA 600V 60Hz 3phase A 10 Definite Purpose Ratings (100,000 cycles acc. to UL 1995) LRA 480V 60Hz 3phase A 54 FLA 480V 60Hz 3phase A 9 07/31/2018 Eaton 277468 ED2018 V46.0 EN 4 / 12

Elevator Control 200V 60Hz 3phase HP 2 200V 60Hz 3phase A 7.8 240V 60Hz 3phase HP 2 240V 60Hz 3phase A 6.8 480V 60Hz 3phase HP 3 480V 60Hz 3phase A 4.8 600V 60Hz 3phase HP 5 600V 60Hz 3phase A 6.1 Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 9 Heat dissipation per pole, current-dependent P vid W 0.3 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 2.6 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 60 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching (ecl@ss8.1-27-37-10-03 [AAB718012]) Rated control supply voltage Us at AC 50HZ V 0-0 Rated control supply voltage Us at AC 60HZ V 0-0 Rated control supply voltage Us at DC V 24-24 Voltage type for actuating DC Rated operation current Ie at AC-1, 400 V A 22 07/31/2018 Eaton 277468 ED2018 V46.0 EN 5 / 12

Rated operation current Ie at AC-3, 400 V A 9 Rated operation power at AC-3, 400 V kw 4 Rated operation current Ie at AC-4, 400 V A 6 Rated operation power Ie at AC-4, 400 V kw 2.5 Modular version No Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as normally closed contact 0 Type of electrical connection of main circuit Spring clamp connection Number of normally closed contacts as main contact 0 Number of main contacts as normally open contact 3 Approvals Product Standards IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking UL File No. E29096 UL Category Control No. NLDX CSA File No. 012528 CSA Class No. 2411-03, 3211-04 North America Certification UL listed, CSA certified Specially designed for North America No 07/31/2018 Eaton 277468 ED2018 V46.0 EN 6 / 12

Characteristics 1: Overload relay 2: Suppressor 3: Auxiliary contact modules 07/31/2018 Eaton 277468 ED2018 V46.0 EN 7 / 12

Squirrel-cage motor Operating characteristics Starting:from rest Stopping:after attaining full running speed Electrical characteristics Make: up to 6 x rated motor current Break: up to 1 x rated motor current Utilization category 100 % AC-3 Typical applications Compressors Lifts Mixers Pumps Escalators Agitators Fans Conveyor belts Centrifuges Hinged flaps Bucket-elevators Air conditioning system General drives in manufacturing and processing machines 07/31/2018 Eaton 277468 ED2018 V46.0 EN 8 / 12

Extreme switching duty Squirrel-cage motor Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 x rated motor current Break: up to 6 x rated motor current Utilization category 100 % AC-4 Typical applications Printing presses Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines 07/31/2018 Eaton 277468 ED2018 V46.0 EN 9 / 12

Switching conditions for non-motor consumers, 3 pole, 4 pole Operating characteristics Non inductive and slightly inductive loads Electrical characteristics Switch on: 1 x rated operational current Switch off: 1 x rated operational current Utilization category 100 % AC-1 Typical examples of application Electric heat 07/31/2018 Eaton 277468 ED2018 V46.0 EN 10 / 12

Dimensions Contactor with auxiliary contact module 07/31/2018 Eaton 277468 ED2018 V46.0 EN 11 / 12

07/31/2018 Eaton Industries GmbH http://www.eaton.eu 07/2018 by Eaton Industries GmbH Eaton 277468 ED2018 V46.0 EN 12 / 12