CRIMP TEST SPECIFICATION SHEET CABLECRAFT 0.5MM² HD RANGE

Similar documents
CRIMP TEST SPECIFICATION: CABLECRAFT COPPER TUBE 10MM 2 HD RANGE

HYDRAULIC CRIMPING TOOL ,7. C sleeve Connectors. Purchase. separately HYDRAULIC PRESSHEAD ,6. C sleeve Connectors

STRATO-THERM Terminals and Splices for High Temperature Applications

Products Catalogue Cable Lugs, Crimping Tools & Bus Bar

Tubing & Hose Metric. Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel

RK-03, RK-HS-03, RK-OC-03, and RK-IR-03 Flow Through Adapters

Cu-terminals and connectors mm²

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

DIMENSIONS DIMENSIONS PKG. WIRE MAX. BOLT REC. STOCK PKG. WIRE MAX. BOLT REC. STOCK CAT. NO. QTY. RANGE INS. HOLE TOOL

Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2

Cu-terminals and connectors mm²

MDual Power Connector

Termco Lugs and Terminals

September Cable termination solutions Lugs and tools for reliable crimping

2M Series Contacts and Tools

Weldable ISO KF Thread. ConFlat Ø.75 [19.1] Ø.062 [1.6] Ø2.73 [69] 1010/1020 CRS Conductor 1-14 Thread Ø1.12 [28.6] 96 [2440] Ø.27 [6.

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY

DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

Battery Operated Compression Tool

Connector Installation Guide Compression and Mechanical Connectors

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

CONNECTORS AND FITTINGS

machines that have experienced premature failures. This applies to machines manufactured between January 2014 and March 2015.

L&T MANUFACTURING, INC.

PICO 500 SERIES SERVICE MANUAL

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

PAD RETAINING AND SPRING APPLICATION PAGE

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

CONTENTS OVERHEAD SLEEVES AND LUGS

Tools and Accessories

Good for ABS applications. Temperature rating -87ºF to 150ºF (-66ºC to 66ºC) Temperature rating -87ºF to 150ºF (-66ºC to 66ºC)

UK Utility Solution Provider Ltd Catalog. Table of Contents. Product Code Page

SPIRAL POINT TAPS for through hole tapping

Low-Pressure Transportation and Hydraulic Hose and Fittings the right solution for special applications and requirements

Chevy Colorado / GMC Canyon INSTALL GUIDE

Thank you for your interest in the Copper Battery Terminals through the farm magazine.

Evolve LED Roadway Lighting

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Connecting Solutions

3 Terminals, Kits and Tools

CABLE MANAGEMENT. Call Connectronics (888) / / OUR RESOURCES ARE YOUR SOLUTION. Stackable Snap-In Hanger Kits

Wire Piercing Guide Heavy Duty Circuit Tester 6, 12, 24 Volt Professional Circuit Tester 6, 12 Volt

H05 V-K PVC-Single Cores, fine wire stranded

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Part number: (X1361-) Description: Conduit Duraflex;.218 O.D. Coiled construction; H.D.P.E. jacket only, unlined.

32L-CR-P-D. Inde-Pendant Pendant Direct. Ordering Guide. Key Features 32L-CR-P-D. Fixture Type: Project Name: Quick Find litecontrol.

CURRENT TRANSFORMER - AST line

CP 600V Cable Protectors

Powerlock Termination Guide

HP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending

12-M1. Amphenol. Micro-Miniature Connectors for Harsh Environments

MA-LINE TOOLS AND ACCESSORIES

Aluminium Alloy: EN Standards for Aluminium Extrusions

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS

Form No Parts List for: MODEL B HYDRAULIC PUMP GENERAL SECTION PG PG553-2UK FT600 PG554. PG120A Series Y70G Series. Sheet No.

AMPLIMITE Cable Connector Accessories

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

CMC/CPP/CMB SERIES. Power & signal connectors with screw locking system. Human photo. Can be environmental/ documentaty style or portrait of engineer.

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

AIR HYDRAULIC PUMP SIDE VIEW

LPK1550 Hydraulic Crimping Tool 15 ton

Brass BS 2874 CZ121 (HPC103, HPC111) Al. Alloy 2014A T6 (HPC105)

HBB power connector. Product description

DIE DESIGN AND CONSTRUCTION SPECIFICATIONS STAMPING - EUROPE. COMPRESSION SPRINGS DIMS IN MM. FORCE IN N Fn. DIM. TOL.+ Sn if ig e 1 e

Broadcast. Use Solid Reliability. Return Loss Graph Lo-Pro. Environmental. Electrical. Contact. millohm

Master Power Brakes Electric Vacuum Pump Kit Various Applications P/N: AC9001K

Tools and ferrules. Contents. Tools and ferrules. Tools and ferrules J.1

CATALOG. Sta-Kon Power, connection & control Wire termination & insulation

JEEP TJ INSTALL GUIDE

Compression Connectors

J&JK SERIES SUBMINIATURE. DCONNECTOR EMI prevention shielding cover ( J cover) J COVER. Cover nut. Cover. Dimensions mm(in.) W.

Termination Products. Installing Kits. Recommended Tools. Plier-Type Tools Used for installation of various Sta-Kon terminal series

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor

Aluminum Mechanical Lugs

SCREW HOSE COUPLINGS SCREW HOSE COUPLINGS B.1. STANDARD. LMC s screw hose couplings with a smooth hose shank comply with EN / DIN 2817.

SSD400/EURO SOLARIS SCRUBBER DRYER PARTS LIST 230V 50/HZ SSD400/EURO (Series B from Serial Number 01450)

Application Specification Pin&3Pin Miniature waterproof connector 28July2016 REV: C

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)

MODEL DESCRIPTION IN LBS.

DSUBMINIATURE CONNECTOR J SERIES

This group contains information on the coach parking brake from the actuating lever to the transmission. ...Parking Brake Cables and Hardware

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Unit 3 Lesson 2 Electric Current. Copyright Houghton Mifflin Harcourt Publishing Company

Type Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3

UNIT CONVERSIONS & FORMULAS

FAKRA-Compliant SMB Gen-4 Connector System

SUBMERSIBLE SECONDARY CONNECTORS

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI

Shell material Insulator Contacts Sealing Temperature Mating Protection

RA CONNECTOR IDC. 1Certified LR Features. Standards. Disconnectable Insulation displacement connectors for 1.27mm pitch ribbon cables. 2.

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

40 Ton and 50 Ton Ironworker

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

FLEET ESSENTIALS QUICK REFERENCE GUIDE Fax Burke Street, Santa Fe Springs, CA 90670

Drive, Fuse & Circuit Breaker Ratings

Key Switches and Keys Emergency Stop Switch Pushbutton Assemblies

Transcription:

Copper tube I/D 1.73mm Test cable 0.5mm² (16/0.2mm) Tri-rated cable to BS 6231 Initial volt drop across joint with 2A dc test current 0.00046v typical Initial resistance across joint = 230 µω typical Initial cable resistance of twice the length of the compression barrel = 544 µω (volt drop test pass) Minimum pull force required to meet electrical installation standard BS EN 60352-2-2006 = 60 Newtons Minimum pull force required to meet London Underground Engineering Rail Standard E 6487 A2 = 75 Newtons Pull force achieved = 113 Newtons typical (pass on both standards) Crimp Test Specification Sheet Cablecraft 0.5mm² HD Range CRIMP TEST SPECIFICATION SHEET CABLECRAFT 0.5MM² HD RANGE

Crimp Test Specification Sheet Cablecraft 0.75mm² HD Range Copper tube I/D 1.73mm Test cable 0.75mm² (24/0.2mm) Tri-rated cable to BS 6231 Initial volt drop across joint with 2A dc test current 0.00023v typical Initial resistance across joint = 115 µω typical Initial cable resistance of twice the length of the compression barrel = 424 µω (volt drop test pass) Minimum pull force required to meet electrical installation standard BS EN 60352-2-2006 = 85 Newtons Minimum pull force required to meet London Underground Engineering Rail Standard E 6487 A2 = 115 Newtons Pull force achieved = 171 Newtons typical (pass on both standards) CRIMP TEST SPECIFICATION SHEET CABLECRAFT 0.75MM² HD RANGE

Crimp Test Specification Sheet Cablecraft 1.0mm² HD Range Copper tube I/D 1.7mm Test cable 1mm² (32/0.2mm) Tri-rated cable to BS 6231 Initial volt drop across joint with 2A dc test current 0.00025v typical Initial resistance across joint = 125 µω typical Initial cable resistance of twice the length of the compression barrel = 319 µω (volt drop test pass) Minimum pull force required to meet electrical installation standard BS EN 60352-2-2006 = 108 Newtons Minimum pull force required to meet London Underground Engineering Rail Standard E 6487 A2 = 150 Newtons Pull force achieved = 221 Newtons typical (pass on both standards) CRIMP TEST SPECIFICATION SHEET CABLECRAFT 1.0MM² HD RANGE

Crimp Test Specification Sheet Cablecraft 1.5mm² HD Range Copper tube I/D 1.9mm Copper tube O/D 3.6mm Test cable 1.5mm² (30/0.25mm) Tri-rated cable to BS 6231 Crimp die - Cablecraft Pt Nº RK 1060, hexagon size 2.8mm A/F (measure crimped terminal top to bottom) Initial volt drop across joint with 6A dc test current 0.00046v typical Initial resistance across joint = 77 µω typical Initial cable resistance of twice the length of the compression barrel = 247 µω (volt drop test pass) Minimum pull force required to meet electrical installation standard BS EN 60352-2-2006 = 150 Newtons Minimum pull force required to meet London Underground Engineering Rail Standard E 6487 A2 = 220 Newtons Pull force achieved = 267 Newtons typical (pass on both standards) Comments: The volume of wall thickness was generous relative to the terminal cross sectional area. There is a noticeable amount of flash after crimping. Indentor is to be positioned on the under side of the terminal. Use hand tool CCT1.5-3HD CCT1.5-4HD CCT1.5-5HD CRIMP TEST SPECIFICATION SHEET CABLECRAFT 1.5MM² HD RANGE

Crimp Test Specification Sheet Cablecraft 4mm² HD Range Copper tube I/D 2.8mm Copper tube O/D 4.7mm Test cable 4mm² (56/0.3mm) Tri-rated cable to BS 6231 Crimp tool - Cablecraft Pt Nº Rennsteig PEW 9.32 marked 6190323 Crimp die - Cablecraft Pt Nº built in die, third cavity in from the tip of the tool, crimp height 2.35mm Initial volt drop across joint with 6A dc test current 0.00031v typical Initial resistance across joint = 51 µω typical Initial cable resistance of twice the length of the compression barrel = 122 µω (volt drop test pass) Minimum pull force required to meet electrical installation standard BS EN 60352-2-2006 = 310 Newtons Minimum pull force required to meet London Underground Engineering Rail Standard E 6487 A2 = 590 Newtons Pull force achieved = 803 Newtons typical (pass on both standards) Comments: The volume of wall thickness was generous relative to the terminal cross sectional area. Indentor is to be positioned on the under side of the terminal. CCT4-4HD CCT4-5HD CCT4-6HD Crimp Section Photo CRIMP TEST SPECIFICATION SHEET CABLECRAFT 4MM² HD RANGE