D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Similar documents
5 Port Solenoid Valve

VQ1000. How to Order Manifold. Kit type

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

5 Port Solenoid Valve

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

5 Port Solenoid Valve

5 Port Solenoid Valve

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Fieldbus System (Output device for driving 5 port solenoid valves)

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

How to Order Manifold. Kit type L8 B4 B6 B8 LM

Series SY3000/5000/7000

Series VQ Port Solenoid Valve

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

Specifications. Fluid Ambient and fluid temperature ( C)

Series SY3000/5000/7000

3 Port Solenoid Valve

Series SV1000/2000/3000/4000

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Pilot Operated 2 Port Solenoid Valve for Dry Air

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

New Concept Connector Type Manifold

3 Port Solenoid Valve

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Fieldbus System (Gateway Decentralized Type)

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Series PCW. PC Wiring System

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

4/5 Port Solenoid Valve

Plug Lead Unit: Flip Type

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Series SY3000/5000 How to Order Manifold

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

Series VP3145/3165/3185

5 Port Solenoid Valve

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

5 Port Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Example. U side. Stations SY5000

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

0.35 W (Without light)

5 Port Solenoid Valve Plug Lead Type

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

How to Order Manifold. Option Symbol

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

4/5 Port Solenoid Valve

Series VQZ1000/2000/3000 Single Unit

4 Port Solenoid Valve

3 Port Solenoid Valve

4 Port Solenoid Valve

5 Port Air Operated Valve

3 Port Air Operated Valve

Base Mounted Plug-in/Plug Lead: Single Unit

5 Port Solenoid Valve

SV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

Vacuum Release Valve with Restrictor

5 Port Solenoid Valve

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Vacuum System Peripherals

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Gateway Type Serial Transmission System

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Gateway System Serial Transmission System

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

Non-Contact Sensor for Workpiece Placement Verification

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Rubber Seal VP300/500/700

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Transcription:

Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (), () port Location Porting specifications Direction Port size Metric Inch D-sub connector Type 0F D-sub connector Conforming to MIL-C-0 JIS-X-0 Flat ribbon cable type 0P Type 0P Type 0PG Type 0PH Plug-in type Common SUP, EXH to 0 stations to stations to stations Flat ribbon cable connector Socket: pin MIL type with strain relief Conforming to MIL-C-0 Flat ribbon cable connector Socket: 0 pin MIL type with strain relief Conforming to MIL-C-0 Flat ribbon cable connector Socket: 0 pin MIL type with strain relief Conforming to MIL-C-0 +COM, COM Valve Lateral, Upward, Downward, /(R) port: ø (), () port: M, ø, ø, /(R) port: ø/" (), () port: ø/", ø/" Series 0-SZ000 / Non Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (), () port Location Porting specifications Direction Metric Port size Inch Type 0-SSZ-0 Non plug-in type Common SUP, EXH to 0 stations Valve Lateral, Upward, Downward, /(R) port: ø (), () port: M, ø, ø, /(R) port: ø/" (), () port: ø/", ø/" Series 0-SZ000 / Serial Transmission Type Protocol type CE-compliant NKE Corp.: Fieldbus System NKE Corp.: Fieldbus H System Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) DeviceNet OMRON Corp.: Compous/S ( outputs) OMRON Corp.: Compous/S ( outputs) CC-Link

Series 0-SZ000 How to Order Plug-in manifold with power supply terminal Connector type F: D-sub connector ( pins) LOCK FREE PG: Flat ribbon cable (0 pins) LOCK FREE LOCK FREE P: Flat ribbon cable ( pins) LOCK FREE PH: Flat ribbon cable (0 pins) LOCK FREE Connector mounting position Symbol Mounting position D 0-SSZ-0 Clean series D side Connector entry direction : Perpendicular connector : Lateral connector LOCK FREE F D - 0 U - P - SUP/EXH block mounting position U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to 0 stations) M Special specifications For special specifications, indicate separately with the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. Valve stations R Pilot type Internal pilot External pilot F: D-sub connector Symbol Stations Note 0 stations Note ) Double wiring 0 0 stations 0 stations Note ) Specified layout (Up to solenoids possible) 0 0 stations PG: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations 0 stations Double wiring 0 stations Specified layout (Up to solenoids possible) stations Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. Power supply terminal Symbol Specifications P VDC, Positive common P VDC, Positive common N VDC, Negative common N VDC, Negative common SUP/EXH block fitting type Straight L Elbow (Upward) Elbow (Downward) P: Flat ribbon cable connector ( pins) Symbol 0 Stations stations Note Double wiring stations 0 stations Specified layout (Up to solenoids possible) 0 0 stations PH: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations 0 stations 0 stations 0 Port Solenoid Valve Plug-in Type stations Double wiring [Option] n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. Specified layout (Up to solenoids possible) Note ) Double wiring: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, position and position valves cannot be used where single solenoid wiring has been specified.) - CE-compliant Q CE-compliant Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

How to Order [Option] n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. Plug-in manifold without power supply terminal 0-SSZ-0 F D - 0 U - Clean series - CE-compliant Q CE-compliant Connector type F: D-sub connector ( pins) LOCK FREE PG: Flat ribbon cable connector (0 pins) LOCK FREE P: Flat ribbon cable ( pins) LOCK FREE PH: Flat ribbon cable connector (0 pins) LOCK FREE SUP/EXH block mounting position U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to 0 stations) M Special specifications For special specifications, indicate separately with the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. Pilot type Internal pilot R External pilot Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block fitting type Straight L Elbow (Upward) Elbow (Downward) Valve stations Connector mounting position Symbol Mounting position D D side Connector entry direction : Perpendicular connector : Lateral connector LOCK FREE LOCK FREE F: D-sub connector Symbol Stations Note 0 stations Note ) Double wiring stations 0 stations Note ) Specified layout (Up to solenoids possible) 0 0 stations PG: Flat ribbon cable connector (0 pins) Symbol 0 0 Stations stations stations Note Double wiring 0 stations Specified layout (Up to solenoids possible) stations P: Flat ribbon cable connector ( pins) Symbol 0 Stations stations stations Note Double wiring 0 stations Specified layout (Up to solenoids possible) 0 0 stations PH: Flat ribbon cable connector (0 pins) Symbol Stations Note 0 stations 0 stations 0 stations 0 stations Double wiring Specified layout (Up to solenoids possible) Note ) Double wiring: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, position and position valves cannot be used where single solenoid wiring has been specified.)

How to Order [Option] How to order solenoid valve ctuation type C 0 - SZ Clean series position single solenoid () () (E) (E) position double solenoid () () (E) (E) position closed center () () (E) (E) position exhaust center () () (E) (E) position pressure center () () position dual port valve: N.C./N.C. () (E) (E) (E) position dual port valve: N.O./N.O. () (E) position dual port valve: N.C./N.O. () (E) () For plug-in (Common for both with and without power supply terminals) 0 - LOZ - C - (E) () (E) () (E) Rated voltage Switch VDC : Without switch VDC When using on a manifold with power supply terminals, be sure to match with the manifold's voltage specifications. ack pressure check valve J: With switch None K uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The product with back pressure check valve is not For switch operation, available for position solenoid refer to page. valves. Pilot type Internal pilot Common specifications R External pilot Positive common External pilot specifications N Negative common are not available for position When using on a manifold with dual port valves. power supply terminals, be sure to match with the manifold's common specifications. : Non-locking push type Manual override D: Push-turn locking slotted type CE-compliant Q CE-compliant, port size C: ø C: ø N: ø/" N: ø/" M: M x 0. Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly Flow Control Directional Control Valves ir Preparation Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 0 Pressure Switches/ Pressure Sensors

LOCK FREE How to Order Valve Manifold ssembly Ordering example (0-SZ000, positive common with power supply terminals) Double solenoid ( VDC) 0-SZ0-LOZ-C ( sets) SUP/EXH block (U side mounting) Single solenoid ( VDC) 0-SZ0-LOZ-C ( sets) With power supply terminals Plug-in manifold 0-SSZ-0PD-0U-P D side Stations U side Made to Order Made to Order (For details, refer to page.) 0-SSZ-0PD-0U-P set (Manifold part no.) 0-SZ0-LOZ-C sets (Single solenoid part no.) 0-SZ0-LOZ-C sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix to the part no. of the solenoid valve, etc. Stations are counted from the D side as the st one. dd the valve part number under the manifold part number. For complex arrangements, specify them on the manifold specification sheet. Manifold Specifications Model Manifold (P: SUP), / (R: EXH) D-sub connector Flat ribbon cable type 0P Type 0F Type 0P Type 0PG Type 0PH Plug-in type Common SUP, EXH Valve stations (With power terminal) to 0 stations to stations to stations D-sub connector Flat ribbon cable connector Flat ribbon cable connector Flat ribbon cable connector pplicable connector Conforming to Socket: pin MIL type Socket: 0 pin MIL type Socket: 0 pin MIL type MIL-C-0 with strain relief with strain relief with strain relief JIS-X-0 Conforming to MIL-C-0 Conforming to MIL-C-0 Conforming to MIL-C-0 Internal wiring +COM, COM (), () port Location Valve Porting specifications Direction Lateral, Upward, Downward Port size Metric, /(R) port: ø (), () port: M, ø, ø Inch, /(R) port: ø/" (), () port: ø/", ø/" Note ) Weight W (g) W =.n + n + m +. n: Number of SUP/EXH blocks m: Weight of DIN rail Note ) In cases such as those where many valves are operated simultaneously, use type (double side SUP/EXH), applying pressure to the ports on both sides and exhausting from the (R) ports on both sides. Note ) The weight W is the value for the D-sub connector manifold with power supply terminals only. To obtain the weight with solenoid valves attached, add the solenoid valve weights given on page for the appropriate number of stations. For DIN rail weight, refer to page. Flow Rate Characteristics Port size,,, Flow rate characteristics / (P /) / (/ R) (P, E, E) (, ) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.0] 0. [0.] C C 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] M 0.0 [0.] 0. [0.] 0. [0.] 0. [0.] Note) The values are for individually operated position type manifold bases with stations. Values inside [ ] are for position dual port valves. 0. [0.] 0. [0.]

Solenoid Valve Specifications Series Fluid Internal pilot operating pressure range (MPa) External pilot operating pressure range (MPa) position single position double position position dual port valve Operating pressure range Pilot position single pressure position double range position mbient and fluid temperature ( C) 0-SZ000 ir 0. to 0. 0. to 0. 0. to 0. 0. to 0. 00 kpa to 0. 0. to 0. 0. to 0. 0. to 0. 0 to 0 (No freezing. Refer to page 0.) position single, double Max. operating 0 position dual port valve frequency (Hz) position Manual override (Manual operation) Non-locking push type, Push-turn locking slotted type Pilot type Main/Pilot valve common exhaust Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s ) Note) 0/0 Enclosure Dust proof Note) Impact resistance: No malfunction occurred when it was tested with a drop tester in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition. (Default settings) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings) Solenoid Specifications Electrical entry Coil rated voltage (V) Note) llowable voltage fluctuation Power consumption (W) Surge voltage suppressor Indicator light Response Time L type (For plug-in), M type plug connector (M), VDC ±0% of rated voltage 0. (With light: 0.) Diode LED Note) ased on dynamic performance test, JIS -. (Coil temperature: 0 C, at rated voltage) Weight ctuation type position single position double position position dual port valve Valve model 0-SZ 0- - C N 0-SZ 0- - C N 0-SZ 0- -M position position position position position position position position position Response time (ms) (at the pressure of 0. MPa) Without surge voltage suppressor ctuation type or less 0 or less or less 0 or less Single Double Closed center Exhaust center Pressure center Dual port valve Single Double Closed center Exhaust center Pressure center Dual port valve Single Double Closed center Exhaust center Pressure center Dual port valve With surge voltage suppresser S, Z type or less or less 0 or less or less Port size (), () C N ø, ø/" C N ø, ø/" M x 0. Weight (g) Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Manifold Option SUP block disk y installing a SUP block disk in the pressure supply passage of a manifold valve, it is possible to supply two or more different high and low pressures to one manifold. (Use in combination with a pilot port block disk.) lanking block assembly SZ000-- These are mounted when later addition of valves is planned, etc. Series 0-SZ000 Part no. SZ000-- EXH block disk y installing an EXH block disk in the exhaust passage of a manifold valve, it is possible to divide the valve's exhaust so that it does not affect another valve. (Two block disks are needed to divide both exhausts.) Series 0-SZ000 Part no. SZ000-- Plug (White) These are inserted in unused cylinder ports or SUP/EXH ports. Purchase orders are available in units of 0 pieces. Pilot port block disk ød y installing a pilot port block disk in the pilot passage of a manifold valve, it can be function as an internal pilot/external pilot mixed manifold. (Use in combination with a SUP or EXH block disk.) ød Series 0-SZ000 Part no. SZ000-- Dimensions pplicable fitting size ød /" /" /" L Model L D 0-KQP-0 0-KQP-0 0-KQP-0 0-KQP-0 0-KQP-0 0-KQP-0 0. 0. ø ø ø0 ø ø. ø0

Manifold Option DIN rail dimensions / Weight VZ000--- Refer to the L dimension tables Enter a number from the DIN rail dimension table below. L (.) D-sub connector ( pins) / Cable assembly XT00-DS- 0 00 00 L Directional Control Valves. Rail mounting hole pitch. No. 0 L dimension 0.. 0.. 0. Weight (g).......... No. 0 L dimension. 0.. 0.. Weight (g) 0......... 0. Flat ribbon cable type / Cable assembly XT00-FC - to W Terminal no. Triangle mark position (.) Flat Ribbon Cable ssembly Cable length (L). m m m Connector width (W) 0 pins XT00-FC0- XT00-FC0- XT00-FC0-. 0 pins XT00-FC0- XT00-FC0- XT00-FC0-0 pins XT00-FC- XT00-FC- XT00-FC-. For other commercial connectors, use a type with strain relief conforming to MIL-C-0. Example of connector manufacturers HIROSE ELECTRIC CO., LTD. Japan viation Electronics Industry, Limited M Japan Limited J.S.T. Mfg. Co., Ltd. Fujitsu Limited L () () Red.0 Terminal no. Socket side D-sub Connector Cable ssembly Terminal No. Terminal no. Lead wire color Dot marking lack None rown None Red None Orange None Yellow None Pink None lue None Purple White Gray lack 0 White lack White Red Yellow Red Orange Red Yellow lack Pink lack lue White Purple None Gray None Orange lack 0 Red White rown White Pink Red Gray Red lack White White None D-sub Connector Cable ssembly SMC x M. x 0. Cable length (L) ssembly part no. Note. m XT00-DS-0 Cable cores m XT00-DS-00 x WG m XT00-DS-00 For other commercial connectors, use a pin type with female connector conforming to MIL-C- 0. Example of connector manufacturers HIROSE ELECTRIC CO., LTD. Japan viation Electronics Industry, Limited J.S.T. Mfg. Co., Ltd. Fujitsu Limited pprox. ø0 Multi-core vinyl cable 0. mm x C Electric Characteristics Item Characteristics Conductor resistance Ω/km, 0 C Withstand limit VC, minute Insulation resistance MΩkm, 0 C or less 000 or less Note) The minimum bending radius of the D-sub connector cable is 0 mm. Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Manifold Electrical Wiring Type 0F D-sub Connector Type ( pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common Common SOL.b Station SOL.a SOL.b Station SOL.a Positive pin (Common) Negative pin Unused terminal Station 0 Positive pin Negative pin (Common) Unused terminal Station 0 SOL.b SOL.a SOL.b SOL.a Station Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be Power supply terminal Power supply terminal accommodated is 0 manifold stations, with up to solenoids. The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The circuits above are for the double wiring specification with up to 0 or stations. Connect to SOL. for a single solenoid. Moreover, when wiring instructions are given on the manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from the D side as the st one. Type 0P Flat Ribbon Cable Type ( pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common Common SOL.b Station SOL.a SOL.b Station SOL.a 0 Positive pin (Common) Negative pin Unused terminal Station 0 0 Positive pin Negative pin (Common) Unused terminal Station 0 SOL.b Station SOL.a SOL.b Station SOL.a Triangle mark SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark The common polarity should be the same as the common specifications of the valve to be used. Power supply terminal Power supply terminal The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The maximum number of stations that can be accommodated is 0 manifold stations, with up to solenoids. The circuits above are for the double wiring specification with up to or stations. Connect to SOL. for a single solenoid. Moreover, when wiring instructions are given on the manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from the D side as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring.

Manifold Electrical Wiring Type 0PG Flat Ribbon Cable Type (0 pins) Without Power Supply Terminal 0 0 Common SOL.b SOL.a SOL.b SOL.a Station Station SOL.b Station SOL.a SOL.b Station SOL.a Triangle mark The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. Type 0PH Flat Ribbon Cable Type (0 pins) Without Power Supply Terminal Common SOL.b SOL.a Station SOL.b Station SOL.a SOL.b Station SOL.a Triangle mark With Power Supply Terminal Positive common 0 Positive pin (Common) Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark Power supply terminal Positive common 0 Negative pin Positive pin (Common) Negative pin Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark Negative common 0 Positive pin Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark Power supply terminal Negative common 0 Negative pin (Common) The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. The circuits above are for the double wiring specification with up to or stations. Connect to SOL. for a single solenoid. Moreover, when wiring instructions are given on the manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from the D side as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. With Power Supply Terminal Positive pin Negative pin (Common) Station SOL.b Station SOL.a Station SOL.a Station SOL.a Station SOL.a Station Triangle mark Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control The common polarity should be the same as the common specifications of the valve to be used. The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. Power supply terminal Power supply terminal The maximum number of stations that can be accommodated is manifold stations, with up to solenoids. The circuits above are for the double wiring specification with up to stations. Connect to SOL. for a single solenoid. Moreover, when wiring instructions are given on the manifold specification sheet, the signal for single and the, signals for double should be wired in order,,,...etc., without skipping or leaving any connectors remaining. Stations are counted from the D side as the st one. Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. Flow Control Pressure Switches/ Pressure Sensors

Wiring of Plug-in Type Manifold with Power Supply Terminal (Example) Since the power supply to drive valves with power supply terminals can be supplied from either the control side or the manifold side, these wiring examples should be used for reference when wiring is performed.. Wiring example when using manifold power supply terminal PLC (Programmable Logic Controller) Manifold valve (0-SSZ-0PGD-0U- ) 0-SZ manifold internal wiring (Flat ribbon cable, Positive common specifications) Negative 0 pin Control side (PLC, etc.) (NPN open collector output) COM DC power supply Solenoid valve Power supply + terminal + Power supply Cable assembly XT00-FC0- etc. Triangle mark. Wiring example when not using manifold power supply terminal (Power is supplied to the control side or along the wiring, etc.) PLC (Programmable Logic Controller) Manifold valve (0-SSZ-0PGD-0U- ) 0-SZ manifold internal wiring (Flat ribbon cable, Positive common specifications) Positive pin 0 Power supply + Control side (PLC, etc.) (NPN open collector output) COM DC power supply Solenoid valve + Power supply terminal Cable assembly XT00-FC0- etc. Triangle mark Caution Signal wire, COM position, etc. of PLC are different from each manufacturer. When connecting with PLC, read the specifications carefully and understand the electrical circuit. Poor wiring could cause damage to PLC, power source, etc. as well as manifold and valve.

FREE Dimensions: 0-SZ000 for Plug-in 0-SSZ-0FD - Stations U- [, (R) port] pplicable tubing O.D.: ø, ø/". DIN rail.. Light/surge voltage suppressor.. Press and turn for ( ) (Pitch) P = 0. R P M x 0. [(), () port] L Switch for locking a connector Manual override (Station n) (Station ) ON OFF ON OFF LOCK the locking type. () port side: Orange () port side: Green L (Rail mounting hole pitch.) L [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" (L)........ (.). [With External Pilot Specifications] (X, PE port) pplicable tubing O.D.: ø, ø/" DIN rail holding screw Power supply terminal (M terminal screw) (.) 0.. (When equipped with switch). R PE X P. JIS-X-0 pplicable D-sub connector: MIL-C-0 equivalent Terminal no.. { }. (The voltage indication marking is for VDC.) Note) For manifold dimensions with elbow fitting, refer to page. Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Internal Pilot Manifold L Dimension... 0.... L n L L L L 0. 00 0. 0.... Switch (When equipped with switch)... 0.. External Pilot Manifold L Dimension... 0.... 0. 0.. L n L L L L....... 0 0. 00.. Flow Control Pressure Switches/ Pressure Sensors

FREE Dimensions: 0-SZ000 for Plug-in 0-SSZ-0FD - Stations -. (Pitch) P = 0. [, (R) port] pplicable tubing O.D.: ø, ø/" [With External Pilot Specifications]... R R R PE R [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" P L P M x 0. [(), () port] (L) (X, PE port) pplicable tubing O.D.: ø, ø/" X P P { } JIS-X-0 pplicable D-sub connector: MIL-C-0 equivalent (.) Switch for locking a connector.. 0.... DIN rail LOCK.. Terminal no... Manual override Press and turn for ( the locking type. ) () port side: Orange () port side: Green L (Rail mounting hole pitch.) L (Station n) (Station ) DIN rail holding screw Power supply terminal (M terminal screw). (When equipped with switch). (The voltage indication marking is for VDC.) Light/Surge voltage suppressor.. ON ON OFF OFF.. (.) Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension L n L L L L.. 0.. 0. 0.. External Pilot Manifold L Dimension L n L L L L. 0.. 0. 0....... 0 Switch (When equipped with switch). 0. 0.. 0. 0. 00 0 0. 00 0..... 0. 0........ 0. 0.. 0. 0................ 0. 00.. 0. 00.. 0. 00. 0 0. 00. 0...

FREE Dimensions: 0-SZ000 for Plug-in 0-SSZ-0PD - Stations U- ( pins). (Pitch) P = 0. M x 0. [(), () port] [With External Pilot Specifications]. Directional Control Valves [, (R) port] pplicable tubing O.D: ø, ø/". L n L L L L 0. 00.. DIN rail Light/surge voltage suppressor. R P Press and turn for ( ) Internal Pilot Manifold L Dimension... 0.... [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" L (L) Switch for locking a connector Manual override the locking type. 0. 0... LOCK () port side: Orange () port side: Green L (Rail mounting hole pitch.) L (Station n) (Station ) ON OFF ON OFF.......... 0.. External Pilot Manifold L Dimension... 0.... 0. 0.. L n L L L L (X, PE port) pplicable tubing O.D.: ø, ø/".. DIN rail holding screw Power supply terminal (M terminal screw). (.) Switch (When equipped with switch). (.) 0.. (When equipped with switch) 0PG (0 pins) R P Triangle mark pplicable connector: 0 pin MIL type with strain relief (Conforming to MIL-C-0).. Triangle mark position PE X.. pplicable connector: pin MIL type with strain relief (Conforming to MIL-C-0).. 0PH (0 pins)... Triangle mark position (The voltage indication marking is for VDC.) pplicable connector: 0 pin MIL type with strain relief (Conforming to MIL-C-0) Triangle mark position Note ) Types 0PG and 0PH differ only in their connectors, and the L through L dimensions are the same as type 0P. Note ) For manifold dimensions with elbow fitting, refer to page.... 0 0. 00.. 0 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

FREE Dimensions: 0-SZ000 for Plug-in 0-SSZ-0PD - Stations -. (Pitch) P = 0. ( pins) M x 0. [(), () port] [, (R) port] pplicable tubing O.D.: ø, ø/" [With External Pilot Specifications].... P X P P P R PE R R R (.) [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" L. Switch for locking a connector (L) (X, PE port) pplicable tubing O.D.: ø, ø/" pplicable connector: pin MIL type with strain relief (Conforming to MIL-C-0).... 0.. LOCK. Triangle mark.. DIN rail Manual override Press and turn for ( ) the locking type. () port side: Orange () port side: Green L (Rail mounting hole pitch.) L Power supply terminal (M terminal screw) DIN rail holding screw. (When equipped with switch) pplicable connector: 0 pin MIL type with strain relief (Conforming to MIL-C-0). Triangle mark position (The voltage indication marking is for VDC.) pplicable connector: 0 pin MIL type with strain relief (Conforming to MIL-C-0) (Station n) (Station ) Light/surge voltage suppressor.... ON ON OFF OFF.. (.) Triangle mark position Triangle mark position Internal Pilot Manifold L Dimension L n L L L L.. 0.. 0. 0.. External Pilot Manifold L Dimension L n L L L L. 0.. 0. 0.... Switch (When equipped with switch)... 0. 0. 0.. 0. 0. 00 0 0. 00 0.. 0PG (0 pins) 0PH (0 pins) Note ) Types 0PG and 0PH differ only in their connectors, and the L through L dimensions are the same as type 0P. Note ) For manifold dimensions with elbow fitting, refer to page. 0. 0.. 0. 0... 0.. 00 00 0.............. 0.... 0. 0......... 0. 00.. 0. 00. 0...

Dimensions with Elbow Fitting: 0-SZ000 for Plug-in, D-sub Connector L 0-SSZ-0FD - Stations U - (The fitting dimension of the flat ribbon cable and non plug-in types is the same.). (Pitch) P = 0. Directional Control Valves 0.. (.) (R) port port..... U side [, (R) port] pplicable tubing O.D.: ø (Station n) FREE LOCK (Station ) D side () port () port. 0.. 0.. (.). (.). Downward (Type ) [Valve] [Supply/Exhaust block] (.).. () () (). (R) (.). () ir Preparation Flow Control Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders Pressure Switches/ Pressure Sensors

Series 0-SZ000 How to Order Non plug-in manifold 0 0 0-SSZ-0 Clean series Stations stations 0 stations - 0 U - SUP/EXH block mounting position D D side ( to 0 stations) U U side ( to 0 stations) oth sides ( to 0 stations) M Special specifications For special specifications, indicate separately with the manifold specification sheet. Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block fitting type L Straight Elbow (Upward) Elbow (Downward) Port Solenoid Valve Non Plug-in Type [Option] n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. - CE-compliant Q CE-compliant Pilot type Internal pilot R External pilot How to Order Valve Manifold ssembly Ordering example (0-SZ000, Non plug-in) Double solenoid ( VDC) 0-SZ0-MZ-C ( sets) SUP/EXH block (U side mounting) Single solenoid ( VDC) 0-SZ0-MZ-C ( sets) U side D side Stations 0-SSZ-0-0U set (Manifold part no.) 0-SZ0-MZ-C sets (Single solenoid part no.) 0-SZ0-MZ-C sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix to the part no. of the solenoid valve, etc. Stations are counted from the D side as the st one. dd the valve part number under the manifold part number. For complex arrangements, specify them on the manifold specification sheet.

How to Order [Option] ctuation type C 0-SZ 0 - M - C - position single solenoid () () position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. () Clean series (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) (E) position dual port valve: N.O./N.O. () (E) position dual port valve: N.C./N.O. () (E) () () (E) () (E) () (E) Pilot type Internal pilot R External pilot External pilot specifications are not available for position dual port valves. ack pressure check valve None K uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The product with back pressure check valve is not available for position solenoid valves. Rated voltage VDC VDC Common specifications Positive common N Negative common The symbol is for no light/surge voltage suppressor. Manual override : Non-locking push type D: Push-turn locking slotted type Light/Surge voltage suppressor S Z Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor Electrical entry M: With lead wire (Length 00 mm) MN: Without lead wire - + - COM - + - COM CE-compliant Q, port size C: ø C: ø N: ø/" N: ø/" M: M x 0. CE-compliant Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly MO: Without connector Flow Control Directional Control Valves ir Preparation Pressure Control Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders Pressure Switches/ Pressure Sensors

Manifold Specifications Model Type 0-SSZ-0 Made to Order Made to Order (For details, refer to page.) Manifold (P: SUP), / (R: EXH) Valve stations (), () port Location Porting specifications Direction Metric Port size Inch Note ) Weight W (g) n: Number of SUP/EXH blocks m: Weight of DIN rail Non plug-in type Common SUP, EXH to 0 stations Valve Lateral, Upward, Downward, /(R) port: ø (), () port: M, ø, ø, /(R) port: ø/" (), () port: ø/", ø/" W = n + m + Note ) In cases such as those where many valves are operated simultaneously, use type (double side SUP/EXH), applying pressure to the ports on both sides and exhausting from the (R) ports on both sides. Note ) The weight W is the value for the manifold only. To obtain the weight with solenoid valves attached, add the solenoid valve weights given on page for the appropriate number of stations. For DIN rail weight, refer to page. Flow Rate Characteristics Port size Flow rate characteristics,,, / (P /) / (/ R) (P, E, E) (, ) C [dm /(s bar)] b Cv C [dm /(s bar)] b Cv C 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.0] 0. [0.] C C 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] M 0.0 [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] 0. [0.] Note) The values are for individually operated position type manifold bases with stations. Values inside [ ] are for position dual port valves.

COM COM COM COM COM Dimensions: 0-SZ000 for Non Plug-in 0-SSZ-0- Stations U [, (R) port] pplicable tubing O.D.: ø, ø/" (.). 0. DIN rail. U side... R P Light/Surge voltage suppressor L (Pitch) P = 0. Manual override (Press and turn for the locking type.) () port side: Orange () port side: Green L (Rail mounting hole pitch.) L (Station n)...(station ) [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" (L).. D side..... DIN rail holding screw.. pprox. 00 Lead wire length [With External Pilot Specifications].. R P (X, PE port) pplicable tubing O.D.: ø, ø/" PE X Note) For manifold dimensions with elbow fitting, refer to page. Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Internal Pilot Manifold L Dimension 0. 00 0... 0.. L n L L L L. 0.. 0. 0.. 0. External Pilot Manifold L Dimension 0. 00 0... 0.... L n L L L L 0. 0... 0.. Flow Control Pressure Switches/ Pressure Sensors

COM COM COM COM COM Dimensions: 0-SZ000 for Non Plug-in 0-SSZ-0- Stations D (Pitch) P = 0.. [, (R) port] pplicable tubing O.D.: ø, ø/" [With External Pilot Specifications]... P R P X R PE [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" (.) U side L. (L) D side 0...... DIN rail Manual override (Press and turn for the locking type.) () port side: Orange () port side: Green L (Rail mounting hole pitch.) DIN rail holding screw pprox. 00 Lead wire length. L (Station n)...(station ) Light/surge voltage suppressor... (X, PE port) pplicable tubing O.D.: ø, ø/" Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension 0. 00 0... 0.. L n L L L L. 0.. 0. 0.. 0. External Pilot Manifold L Dimension 0. 00 0... 0.... L n L L L L 0. 0... 0..

COM COM COM COM COM Dimensions: 0-SZ000 for Non Plug-in 0-SSZ-0- Stations [, (R) port] pplicable tubing O.D.: ø, ø/" (Pitch) P = 0.. [With External Pilot Specifications]. Directional Control Valves.. R P [(), () port] pplicable tubing O.D.: ø, ø/" ø, ø/" (.). 0. DIN rail U side. Light/surge voltage suppressor. L R P (Station n)...(station ) Internal Pilot Manifold L Dimension L n L L L L 0. 00... 0.. 0. 0 External Pilot Manifold L Dimension L n L L L L.... 0.... 0. 0........ Manual override (Press and turn for the locking type.) () port side: Orange () port side: Green L (Rail mounting hole pitch.) L....... 0 (L) D side... DIN rail holding screw 0. 0 0 0. 00 0. pprox. 00 Lead wire length. R P (X, PE port) pplicable tubing O.D.: ø, ø/" PE X Note) For manifold dimensions with elbow fitting, refer to page. 0. 00 0.... 0... 0....... 0. 0 0. 0........ R P.. 0. 00 0 0. 00 0 0. 00.. Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Type 0S Series 0-SZ000 EX0 Integrated-type (For Output) Serial Transmission System How to Order Manifold Note) Refer to the SI unit part no. for the SI unit comparable with CE. [Option] n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. 0 SSZ 0S Q D 0 U Clean series SI unit specifications Symbol Protocol type 0 Without SI unit NKE Corp.: Fieldbus System ( outputs) F H J J Q DeviceNet R R V CC-Link NKE Corp.: Fieldbus H System Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) OMRON Corp.: Compous/S System ( outputs) OMRON Corp.: Compous/S System ( outputs) SI unit mounting position D D side This should be indicated even without SI unit. Valve stations Symbol 0 Stations stations Note Double wiring 0 0 stations stations Specified layout (Up to solenoids possible.) stations Note ) Double wiring: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Note ) R and J are available with up to solenoids. CE-compliant Q CE-compliant Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block fitting type Straight L Elbow (Upward) Elbow (Downward) Pilot type Internal pilot R External pilot SI unit part no. Symbol Protocol type F NKE Corp.: Fieldbus System H NKE Corp.: Fieldbus H System J Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) J Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK ( outputs) Q DeviceNet R OMRON Corp.: Compous/S ( outputs) R OMRON Corp.: Compous/S ( outputs) V CC-Link SI unit part no. CE-compliant EX0-SUW EX0-SUH EX0-SSL EX0-SSL EX0-SDN EX0-SCS EX0-SCS EX0-SMJ SUP/EXH block mounting position U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to stations) M Special specifications For special specifications, indicate separately with the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. How to Order Valve Manifold ssembly Ordering example (Compous/S compatible SI unit) SUP/EXH block assembly (U side mounting) Double solenoid ( VDC) 0-SZ0-LOZ-C(-Q) ( sets) Single solenoid ( VDC) 0-SZ0-LOZ-C(-Q) ( sets) 0-SSZ-0SRD-0U (-Q) 0-SZ0-LOZ-C (-Q) 0-SZ0-LOZ-C (-Q) set (Manifold part no.) sets (Single solenoid part no.) sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix it to the part no. of the solenoid valve, etc. U side Stations Stations are counted from the D side as the st one. dd the valve part number under the manifold part number. For complex arrangements, specify them on the manifold specification sheet. Manifold base ( stations) 0-SSZ-0SRD-0U(-Q) D side SI unit (D side mounting)

How to Order Solenoid Valve [Option] 0 SZ 0 LOZ C Directional Control Valves C Clean series ctuation type position single solenoid () (E) () () (E) position double solenoid () (E) (E) position closed center () () (E) (E) position exhaust center () () (E) (E) position pressure center () () (E) (E) position dual port valve: N.C./N.C. () (E) () (E) () (E) () (E) position dual port valve: N.O./N.O. () (E) position dual port valve: N.C./N.O. () (E) Pilot type Rated voltage VDC Internal pilot R External pilot External pilot specifications are not available for position dual port valves. Switch : Without switch J: With switch For switch operation, refer to page. ack pressure check valve None K uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The product with back pressure check valve is not available for position solenoid valves. Manual override : Non-locking push type D: Push-turn locking slotted type Made to Order X0, port size C: ø C: ø M: M x 0. CE-compliant Q CE-compliant Main valve fluororubber (Refer to page.) Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders 00

R X P PE R Dimensions: 0-SZ000 for EX0 Integrated-type (For Output) Serial Transmission System 0-SSZ-0S D- Stations U [With External Pilot Specifications]. (X, PE port) pplicable tubing O.D.: ø.. (Pitch) P = 0. [(), () port] pplicable tubing O.D.: ø ø (.) P.. 0.... [, (R) port] pplicable tubing O.D.: ø L M x 0. [(), () port] (L) SI unit.. DIN rail DIN rail holding screw Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L. (When equipped with switch) (Station n) (Station ) Light/Surge voltage suppressor side: Orange side: Green. (.) (DIN rail dimension) ON ON OFF OFF Note) For manifold dimensions with elbow fitting, refer to page. Switch (When equipped with switch) Internal Pilot Manifold L Dimension L n L L L L. 0.. 0. 0... 0. 0.... 0. 00.. 0.. External Pilot Manifold L Dimension L n L L L L.. 0. 0... 0. 0.... 0. 00.... 0. 0.. 0

Dimensions: 0-SZ000 for EX0 Integrated-type (For Output) Serial Transmission System 0-SSZ-0S D- Stations [With External Pilot Specifications]. (X, PE port) pplicable tubing O.D.: ø Directional Control Valves (.) DIN rail. 0.. DIN rail holding screw Light/Surge voltage suppressor side: Orange side: Green. (.) (DIN rail dimension). (Pitch) P = 0. R P L ON OFF ON OFF R P Manual override Press and turn for the locking type. (): Orange (): Green L (Rail mounting hole pitch.) L (Station n) (Station ). pplicable tubing O.D.: ø ø (L). PE R X P. Switch (When equipped with switch). SI unit... (When equipped with switch) R P Note) For manifold dimensions with elbow fitting, refer to page. Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Internal Pilot Manifold L Dimension L n L L L L. 0. 0..... 0. 00. 0. 00.. External Pilot Manifold L Dimension L n L L L L 0. 0..... 0. 00. 0. 00... 0 Flow Control L n 0 L L L L. 0.. 0. 0... 0. 0.... L n 0 L L L L.. 0. 0... 0. 0.... 0. 00.. Pressure Switches/ Pressure Sensors 0

Type 0S Series 0-SZ000 EX0 Gateway-type Serial Transmission System How to Order Manifold [Option] n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. 0 SSZ 0S D 0 U Clean series SI unit specifications NPN output (+ COM) N PNP output ( COM) CE-compliant Q CE-compliant Unit mounting position D D side Valve stations Symbol 0 Stations stations Note Double wiring Note ) 0 stations 0 stations Specified layout Note ) (Up to solenoids possible.) stations Includes the number of blanking block assemblies. Note ) Double wiring: Single, double, position and position solenoid valves can be used at all of the manifold stations. Note ) Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) How to Order Valve Manifold ssembly Ordering example SUP/EXH block assembly (U side mounting) Double solenoid ( VDC) 0-SZ0-LOZ-C(-Q) ( sets) Single solenoid ( VDC) 0-SZ0-LOZ-C(-Q) ( sets) Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. (Max. ) SUP/EXH block fitting type Straight L Elbow (Upward) Elbow (Downward) Pilot type Internal pilot R External pilot SUP/EXH block mounting position U U side to 0 stations D D side oth sides to stations M Special specifications For special specifications, indicate separately with the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. Stations U side LOCK FREE Manifold base ( stations) 0-SSZ-0SD-0U(-Q) 0 PW COM SI unit part no. Symbol SI unit specifications NPN output (+ COM) N PNP output ( COM) SI unit part no. EX0-S00 EX0-S0 D side 0-SSZ-0SD-0U (-Q) set (Type 0S -station manifold part no.) 0-SZ0-LOZ-C (-Q) sets (Single solenoid part no.) 0-SZ0-LOZ-C (-Q) sets (Double solenoid part no.) The asterisk denotes the symbol for assembly. Prefix it to the part no. of the solenoid valve, etc. Stations are counted from the D side as the st one. dd the valve part number under the manifold part number. For complex arrangements, specify them on the manifold specification sheet. 0

How to Order [Option] How to order solenoid valve For plug-in (Common for both with and without power supply terminals) 0 SZ 0 LOZ C Clean series C ctuation type position single solenoid () (E) () () (E) position double solenoid () (E) (E) position closed center () () (E) (E) position exhaust center () () (E) (E) position pressure center () () (E) (E) position dual port valve: N.C./N.C. () (E) () (E) () () (E) position dual port valve: N.O./N.O. () (E) position dual port valve: N.C./N.O. () Pilot type Rated voltage VDC ack pressure check valve K None uilt-in The built-in back pressure check valve type has an effective area approximately 0% smaller. The product with back pressure check valve is not available for position solenoid valves. Internal pilot R External pilot External pilot specifications are not available for position dual port valves. : Non-locking push type Switch : Without switch J: With switch For switch operation, refer to page. Common specifications Positive common N Negative common When the SI unit specifications are PNP output ( COM), the common specifications of valves should be negative common. Manual override D: Push-turn locking slotted type, port size C: ø C: ø M: M x 0. CE-compliant Q Mede to Order X0 CE-compliant Main valve fluororubber (Refer to page.) Elbow fitting assembly (Upward) L: ø elbow fitting assembly L: ø elbow fitting assembly Elbow fitting assembly (Downward) : ø elbow fitting assembly : ø elbow fitting assembly Directional Control Valves Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control (E) (E) Flow Control 0 Pressure Switches/ Pressure Sensors

R P ON OFF ON OFF 0 R P Dimensions: 0-SZ000 for EX0 Gateway-type Serial Transmission System 0-SSZ-0S D- Stations U-. (Pitch) P = 0. M x 0. [With External Pilot Specifications]. X PE... pplicable tubing O.D.: ø ø (X, PE port) pplicable tubing O.D.: ø U side L (L) D side. 0. (.) (When equipped with switch). DIN rail. (.) FREE LOCK DIN rail holding screw Manual override (Press and turn for the locking type.) (): Orange (): Green L (Rail mounting hole pitch.) L SI unit 0.. PWR COM Light/Surge voltage suppressor side: Orange side: Green (Station n) (Station ).. Switch (When equipped with switch) Note) For manifold dimensions with elbow fitting, refer to page. Internal Pilot Manifold L Dimension L n L 0. L 0 L. L External Pilot Manifold L Dimension L n L L. L. L 0....... 0... 0... 0... 0.. 0. 00.. 0. 00......... 0.. 0.. 0.... 0 0.. 0....

R P ON OFF ON OFF R P 0 R P Dimensions: 0-SZ000 for EX0 Gateway-type Serial Transmission System 0-SSZ-0S D- Stations -. (Pitch) P= 0. M x 0. [(), () port] [With External Pilot Specifications]. Directional Control Valves. 0. (.). (When equipped with switch) DIN rail.. L L (.) L (Rail mounting hole pitch.) Internal Pilot Manifold L Dimension L n L L. L. L U side Light/Surge voltage suppressor side: Orange side: Green.... External Pilot Manifold L Dimension L n L L L L.... 0. 00..... FREE LOCK (L) DIN rail holding screw Manual override (Press and turn for the locking type.) (): Orange (): Green (Station n) (Station ) 0. 00... pplicable tubing O.D.: ø ø... 0.. 0..... 0. 0. 0 0. 0. 0......... D side SI unit 0 Switch (When equipped with switch) Note) For manifold dimensions with elbow fitting, refer to page.... 0.... (X, PE port) pplicable tubing O.D.: ø. 0.. 0... 0.. 0. 00.. PWR COM PE 0. 00........ 0... X 0 Fittings & Tubing Modular F. R. ir Grippers Rotary ctuators ir Cylinders ir Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Type 0GD Series 0-SZ000 PC Wiring System Plug-in Type [Option] Connector entry direction Symbol 0 0 0 Stations stations stations stations 0 stations SSZ 0GD 0 U Clean series Upward Lateral Valve stations Note Double wiring Specified layout (Up to solenoids possible.) Note ) Double wiring: Single, double, position and position solenoid valves can be used at all of the manifold stations. Specified layout: Indicate wiring specifications on the manifold specification sheet. (Note that double, and position valves cannot be used where single solenoid wiring has been specified.) Note ) The number of the blanking block is also included. How to Order Manifold SUP/EXH block assembly mounting position U U side ( to 0 stations) D D side ( to 0 stations) oth sides ( to stations) M Special specifications For special specifications, indicate separately with the manifold specification sheet. Note) total of up to SUP/EXH blocks can be mounted. Please contact SMC if or more will be mounted. n order cannot be placed with only the manifold part no. e sure to order solenoid valves for mounting at the same time while referring to the ordering example. Pilot type R Internal pilot External pilot Option When a longer DIN rail is desired than the specified stations, specify the station number to be required. SUP/EXH block assembly fitting type L Straight Elbow (Upward) Elbow (Downward) CE-compliant Q CE-compliant How to Order Valve [Option] C 0 0 Clean series ctuation type SZ 0 LOZ C position single solenoid position double solenoid position closed center position exhaust center position pressure center position dual port valve: N.C./N.C. position dual port valve: N.O./N.O. position dual port valve: N.C./N.O. R Pilot type Internal pilot External pilot External pilot specifications are not available for position dual port valve. K J Without switch With switch Rated voltage VDC None uilt-in Switch ack pressure check valve The built-in back pressure check valve type has an effective area approximately 0% smaller. The product with back pressure check valve is not available for position solenoid valves. D, port size C C M L L Manual override ø ø M x 0. ø Elbow fitting assembly (Upward) ø Elbow fitting assembly (Upward) ø Elbow fitting assembly (Downward) ø Elbow fitting assembly (Downward) Non-locking push type Push-turn locking slotted type CE-compliant Q CE-compliant Made to Order Main valve fluororubber X0 (Refer to page.)