GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Similar documents
GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

ESE Series Cast Iron Sewage Pumps

FADE Series Wall Axial Fans

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

StormPro BA Series Sump Pump

Air Curtain. Installation, Operating and Maintenance Instructions

Raydot LLC 24 Actuator (115 VOLT)

ADI-125/750 ADI-125/1500 ADI-125/2500

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

StormPro BCV400 Sewage Ejector Pump

DC to AC Power Inverters

DC to AC Power Inverters

MIL-24/2600Q MIL-24/3200DQ

Cabling for power, control, and video must be run to the installation site before the mount is installed.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

OWNERS MANUAL JANUARY 2007 ISO

Type Flexair Pneumatic Pressure Control Valves

Pack-Master Air, Spark Resistant Product Manual

Penguin Gentoo 600B Cordless Sprayer User s Manual

END USER TERMS OF USE

Kitchen Tech Series Air Curtain

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

OWNERS MANUAL JANUARY 2007 ISO

Fifth Wheel Power Hitch Operations Manual

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

DISC BRAKE CALIPER TOOL SET

PVI 60KW, PVI 82KW, PVI 95KW

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Model 7500 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS. Terrco, Inc.

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

RECHARGEABLE 24 LED WORK LIGHT

Effective June 1, 2013 This guide supersedes all previous versions

Water Jetter Units DU JT50 / DU JT100

25 GALLON PORTABLE OIL LIFT

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

HP190SL Series Slimline Radon Fans

User s Manual and Operating Instructions

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Rapid Shrink 100. Owner s Manual

Electromagnetic Particle Brakes Model: PRB-H

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

TPAK Series COOLANT PUMP

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Operating Instructions for PAC800 Battery Charger

Harvil 4 Foot Air Hockey Table

Dispenser Pan Sensors & Containment Sump Sensors

Power. On Your Terms.

Instruction Manual. Fudge Puppy Display Case

Lint Slide Grid Moist Air Applicator

OBE, OBEXU, ON BOARD Battery Chargers

Read this entire manual before operation begins.

OBAE, OBAEXU, ON BOARD Battery Chargers

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Read this entire manual before operation begins.

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

HR-20P Pneumatically Controlled Pressure Regulator

SUBMERSIBLE POND PUMP

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

TPHK Series Immersible Pump

MACHINES / RECLAIMS WITH DUST BAG

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

QUALITY MISTING PUMPS

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

2SHE Series Direct-Drive Shutter Fans

TPHK Series Immersible Pump

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Pack-Master Product Manual

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

R E A D T H I S F I RST SAW USER GUIDE MODEL SVC4

Owner s Manual Instructions for Installation/Set-up, Operation, Servicing, & Storage

SPC-PANEL Simplex, Single Phase Pump Control Panel

V-Twin Forward Control Installation Instructions

Cincinnati, OH USA

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

TYPE S RELAY VALVE (Volume booster) Service Manual

LBT-3 WITH 300 CFM RECLAIM MANUAL NUMBER: 506 TABLE OF CONTENTS

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

DeZURIK 2 20" BOS BUTTERFLY VALVES

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

10 Year Limited Warranty

A Member of the. Integrated Metering Technologies

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

Installation & Operators Manual

Transcription:

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

2320 Lakecrest Drive, Pekin, Illinois 61554 Telephone: 888-747-4389 Fax: 309-495-0625 Website: www.getzequipment.com Limited Warranty Products manufactured by Getz Equipment Innovators (with exception of electrical products or components) will be free from defects for a period of one year from shipment date. Electrical products and/or components used in manufactured products will have a (6) month warranty from shipment date. During the warranty period, customers who experience any manufacture-related service issues with our products, the product may be returned for repair or replacement. Customer must contact Getz Equipment for approval prior to any product return. Notwithstanding the foregoing, the limited warranty set forth shall be immediately void of customer uses any replacement parts other than those provided by Getz Equipment Innovators. The warranty does not cover normal wear and tear items, defects resulting from modification, alteration, misuse, exposure to corrosive conditions, extremely high temperatures, improper installation or maintenance. Warranties on component items not manufactured by Getz Equipment Innovators are provided by others whose warranty, evaluation and judgment will be final. All implied warranties, including, but not limited to, warranties of fitness for purpose and merchantability, are limited to the time periods as stated above. In no event shall Getz Equipment Innovators be liable to incidental or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusions or limitation of incidental or consequential damages, so that the above limitations or exclusions may not apply to you. Getz Equipment Innovators neither assumes nor authorizes any representative or other person to assume for it any obligation or liability other than as expressly set forth herein. Mobile Service Vehicles: The warranty does not cover: Defects in the chassis and or power unit Defects in separately manufactured products not produced by Getz Equipment Innovators Deterioration due to normal wear, tear, and exposure Repairs made necessary by negligent use, misuse, abuse, loading the service vehicle beyond its gross vehicle weight limitations, accident, acts of God, or other contingencies beyond the control of Getz Equipment Innovators. Repairs deemed necessary by reason of the failure to follow ordinary maintenance procedures. Repairs deemed necessary by reason of alterations done without Getz Equipment Innovators written approval. Warranty Service: All warranty repairs will be performed by Getz Equipment Innovators in Pekin, IL, unless otherwise authorized by Getz Equipment Innovators. Freight: Getz Equipment Innovators will not be liable for shipping or transportation charges to or from customer's location. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To obtain performance to the obligation of the warranty, write to Getz Equipment Innovators, 2320 Lakecrest Drive, Pekin IL 61554, USA for instructions.

TABLE OF CONTENTS 1... HAZARDS 2... INTRODUCTION 3... SET-UP 4... OPERATION 5... DIAGRAM 6... PARTS LIST

HAZARDS Operating the dust collection system involves certain known hazards. EXPLOSION HAZARD: Do not operate this system where flammable vapors are present. FIRE HAZARD: No sparks should be allowed to enter the machine. Mixing chemically reactive materials should be avoided. Personnel should never allow smoking or smoldering materials to enter the machine. Avoid using or storing combustible materials near this machine. A properly installed fire suppression system can minimize the risk of damage. HIGH VOLTAGE HAZARD: Dust collection system operates on 120 volts AC. All service personnel should be aware of this fact and should have adequate training before any repairs are attempted on the equipment. All repairs are to conform to National Electrical Code (NEC) electrical standards. ROTATING MACHINERY HAZARD: The fan inside this unit is rotating at 1740-3600 rpm. The electrical power source must be disconnected and the power switch locked out prior to attempting repairs. Allow the unit to fully stop before any entry is made into the fan compartment below the dust collection filters. 1

INTRODUCTION IMPORTANT!!! This manual contains specific information concerning safety and precautionary measures in some sections. Read this manual thoroughly and comply with each section while using the most stringent safety precautions. The electrical requirements for the dust collection system are 120 volts on a 15 or 20 amp circuit. The dust collection system reduces the amount of airborne dust particles floating in air when servicing dry chemical fire extinguishers. 1. Using this system for any purpose other than dry chemical fire extinguisher agents will void all expressed and implied warranties. WARNING All electrical work should be done by licensed electricians in accordance with the National Electrical Code. 2. Installing a ground fault interrupter receptacle outlet in the power supply source prior to utilizing this system reduces the chance of electrical shock. 4. Do not operate this system without the filter (item 24) or filters (if secondary filter is used) installed and properly seated. 5. Discarded filter media must be disposed of in compliance with local, state, and federal codes. 2

SET-UP INSPECTION As soon as the shipment is received, it should be carefully inspected to make certain that the equipment has arrived in good condition. Even though the equipment is mounted on heavy shipping skids at our plant, it is possible for it to be damaged in shipment. All damages and shortages should be noted on the Bill of Lading and purchaser should take steps to file reports and damage claims to the carrier. Any damage incurred to a unit is the responsibility of the carrier, since it is the manufacturer s policy to make shipments FOB its factory i.e. ownership passes to the purchaser when the unit is loaded and accepted by the driver. Any claims for transit damage or shortage must be brought against the carrier by the purchaser. UNLOADING RECOMENDATION A forklift is recommended for unloading and placement of the system. SET-UP Remove the rubber mat covering the metal grate and examine the filter (item 24) or filters (if secondary filter is used) to be sure the filter or filters are laying flat on the sponge rubber seal material to ensure an adequate seal against dust leakage. Install any (optional) tool holders, nitrogen regulators, blow guns and any other extinguisher service tools on the back wall of the system marked as C. Side panels on the dust collection system item A & B can be unbolted and swung open to accommodate equipment to the sides of the system. Opening the side panels will reduce the pull of air borne dust particles from the front of the system and will equally pull from the front and sides of the system. 3

OPERATING INSTRUCTIONS 1. Move the power switch item (11) to the on position and adjust the angle position of the air louvers on item (13) to direct the air flow out of the system in the most beneficial direction. 2. The magnehelic gauge item (24) will monitor the efficiency of the filter media to collect dust particles. 3. Changing filters on the recommended interval will keep the efficiency of the system at the maximum level and will extend the service life of the blower motor. 4. Recommended Filter Element Change (Single Filter) When the system is operating check the magnehelic gauge (item 19), if the gauge reading is above 1.2 the filter Item (24) needs to be replaced. Primary Filter Part Number: 1G53898. Recommended Filter Element Change (Dual Filter) When the system is operating check the magnehelic gauge (item 19), if the gauge reading is above 1.3, the filter Item (24) needs to be replaced and the secondary filter checked for cleanliness. The secondary filter is the Hepa Filter. (Part Number: 1G53899) The benefit of having the secondary filter is improved filtration. Caution, running the system with clogged or missing filters will result in overheating or damage to the blower motor. 5. Secondary Filter Installation Install the secondary filter below the primary filter (item 24). 4

4G59542 DUST COLLECTOR REPLACEMENT PARTS LIST BLOWER: 1G54419 CAPACITOR: 1G54353 PRIMARY FILTER: 1G53898 SECONDARY (HEPA) FILTER: 1G53899 MAGNEHELIC GAUGE: 1G53929 POWER SWITCH: 1G54057 MAGNEHELIC TUBE: 1G54062 RUBBER MAT: 1G54059 SIDE GRATE: 1G53283 6