VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Similar documents
VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Application example of a motor controlled by MCD100 and protected by a circuit breaker

MCD 200 Series Soft Starters

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Design Guide. VLT Soft Start Controller MCD 100

AuCom - Soft Starters

ABB Softstarter Benefits Charnchanok Thongprad

Pocket Guide VLT Soft Starter the single speed drive

An Engineering Guide to. Soft Starters

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Pocket Guide VLT Soft Starter the single speed drive

RVS-DN Digital Reduced Voltage Motor Starter

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

4491 en / c. D IGISTART et. Reference guide

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443


Variable speed drive or soft starter?

CTi Automation - Phone: Fax: Web:

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Size for Size Best Value in the Industry

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

USERS MANUAL MCD REMOTE OPERATOR

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Starts, stops and protects. Emotron TSA Softstarter

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

RVS-AX Instruction Manual

RVS-DX Digital Reduced Voltage Motor Starter

Section 0.0 Warnings... 2 Section 1.0

A softstarter beyond the ordinary

PCS compact soft starters

Contents. MCD 200 Design Guide. Contents

EMX3 SOFT STARTER. Take control from the start

Starting Torque Limiter Type TCI (Soft Start)

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

Application Description

Dimensions WxHxD [mm] Weight [kg]

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

AUCOM NORTH AMERICA. Complete range of motor starting solutions

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

Softstarters Softstarters

Operating Instructions VLT Soft Starter MCD 500

SOLSTART Instruction Manual

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

SSW07. Soft Starters. Applications. Standard Features

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Electronic soft starters

Features and Benefits. Control Features

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Operating Guide. VLT Soft Starter MCD 600

Product Description. Application Description

Number 1 in efficiency

ABB Softstarters The new PSS line from 3A to 515A

a revolution in soft start motor control The future of soft start motor control at your fingertips

Game changing soft starters

The future of soft start motor control at your fingertips

Number 1 in efficiency

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

Benefits. transmission devices (gearboxes, pulleys, gears, conveyers, etc) Soft-Star ters are static star ting switches, designed for the

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

HVW701 HVAC Drive with By-Pass

Contactors and Motor Starters. Smoother running. Longer lasting. Electronic contactors and motor controllers. Product overview and selection guide

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries

Softstarters from ABB. ABB Low Voltage Products. Controlling the elements

RVS-DN Instruction Manual

825-P Modular Protection System for motors Specification Guide

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

RVS-DX Instruction Manual

Catalog. Softstarters Type PSR, PSS, PSE, PST and PSTB

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

SECTION MOTOR CONTROL

Guide to the Application of Soft Starters

MAKING MODERN LIVING POSSIBLE. Service Manual VLTp Soft Starter - MCD500 *MG17L402*

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Distributed intelligence

Panorama. Softstarters The complete range

Features and Benefits

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Fairford Electronics Product Selector

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

ELECTRONIC SOFT STARTER

Operating Guide VLT Soft Starter MCD 500

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

Softstarters Type PSR, PSS, PSE, PST and PSTB

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Reduced Voltage Motor Starters

Transcription:

.5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator kit. The operator (IP5/NEMA) is mounted on the cabinet front and allows remote control, status indication and motor monitoring of an individual using RS85 serial. It incorporates the following features: AC5b* (Amps) (mm) HxWxD 8A: 6: 5 5 A: 6: 5 8 0x98x6 A: 6: 5 8A: 6: 5 C 60A: 6: 5 0/ A: 6: 59 0 5xx9 85A: 6: 59 Ctick 00A: 6: 59 0A: 6: 59 0x0x 70A: 6: 59 00A: 6: 59 0 E.g. kw 0 kw 0 0 00 0 V 00 5 V 6 00 5 8 00 0 85 0 0 5 00 500 600 700 AC5a* (Amps) (mm) HxWxD 6A: 0: 500 8A: 0: 500 A: 0: 500 0A: 0: 500 5xx70 5A: 0: 500 70A: 0: 500 76A: 0: 500 00A: 0: 500 C 0A: 0: 500 59A: 0: 500 5x6x70 88A: 0: 500 Ctick 98A: 0: 500 5x96x70 99A: 0: 500 5A: 0: 500 5A: 0: 500 850xx80 5A: 0: 500 666A: 0: 500 78A: 0: 500 985A: 0: 500 86A: 0: 500 000x560x5 8A:0: 500 0 0 00 Serial V AC/DC 0 0V AC * Example: AC5b: A: 6: 5 starting current max. times FLC (A) in 6 seconds. 5 seconds minimum between starts. Start/stop, reset LED for start, run, trip Trip codes Current display Motor temp. display 0 ma output T C V IP5/NEMA 0 and 0 come with optional plugin modules for serial. DeviceNet Profibus Modbus RTU ASi* Optional modules are available for serial with 00: DeviceNet Profibus Modbus RTU (*as of May 005) E.g. kw kw Constant effort to improve 00 V 00 6 V The focus is clear at Danfoss: as a leading supplier of drives solutions throughout the world, we have spent years accumulating our technological and application knowhow. Danfoss drives have been produced since 968 and Danfoss Bauer geared 5 7 Enclosure Bookstyle IP ( 07) Compact IP () Compact IP0 (85) B C C0 motors since 97. Today, a long list of references indicates that the name of Danfoss is widely accepted as being synonymous with excellent quality and operational security. We have focused our professional resources on just one techno logical area for years: drives solutions. Years of applying these resources to industrial production lines have given us a wealth of experience and expertise. The results speak for themselves. Danfoss has enjoyed great success, and we are proud of what we do. 0 V AC 00V AC * Example: AC5a: 70A: 0: 500 Starting current max. times FLC (70A) in 0 seconds 50% on load duty cycle and max. 0 starts per hour. 00, 0, 0, 00 s in tables above are for max. 0 C ambient temperature. For other ratings contact Danfoss. DKDD.PB.06.B.0 VLT is a trademark of Danfoss A/S www.simpatico.dk.00.

Type Concept VLT Soft Start Controller 00 VLT Soft Start Controller 00 0 A true fit and forget soft starter for DIN rail mount 00 provides basic soft start and stop function a physically compact starter physically similar to providing basic soft start and 0 but providing enhanced soft start functionality and stop functionality various motor protection functionality s Motor protection 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Enhanced soft start and soft stop Motor and system protection kw @ 00V 00 6V mains voltage 0 00V AC control supply Timed voltage rampup Adjustable start torque Selectable kickstart function Timed voltage rampup Adjustable initial torque Initial current rampup Initial current rampup Torque control Torque boost Dual parameter function Timed voltage rampdown Principle of Phase Angle Control A soft starter is an electronic device that regulates the voltage to the motor and this provides a smooth transition from standstill to full speed operation of the application. s all use the principle of phase angle control.: Backtoback coupled thyristors ramp up the motor voltage. In some s current transformers measure the motor current providing feedback for starting current control but also for numerous motor and application protection functions. s cover a comprehensive range ing and stopping can be controlled in a number of ways depending on the application. Some applications require nonlinear voltage rampup and the voltage ramp is therefore related to the actual current drawn. Conversely, a bandsaw usually requires a quick stop function provided by a DC brake. Then again, a number of applications require a kickstart torque for an instantaneous period of time followed by a soft rampup acceleration. s cover all of these applications and much more. 00: Micro Soft Start Controller for motors up to kw with heavy ratings as standard Unlimited number of starts per hour Contactor style design for easy selection, installation and commissioning 00: Compact Soft Starter for motors up to 0kW Voltage ramps, current limit start and intregrated motor protection Integral bypass design reduce heat dissipation Wide power range with advanced accessory modules 00: Fully featured Soft Starter for motors up to kw Total motor starting solution Advanced start, stop and protection features Local programming keypad and display Timed voltage rampdown Outputs Other features Universal two wire control Programmable via rotary for unlimited number of starts per hour LED indication IP 0 Timed voltage rampdown Linear voltage rampdown Three autoadjustable voltage ramps DC brake function Soft brake function Motor overload (adjustable trip class) Excess start time Reverse phase rotation Motor thermistor input Shorted SCR no start Supply fault no start As 0 + Under current Instantaneous overload Starter overtemperature Restart delay Warning before trips Adjustable phase imbalance sensitivity One output relay: Two output relays: Three output relays: DC brake contactor Programmable via rotary Programmable via 8 rotary Local key pad Buttons for start, stop, reset and remote control Inputs for two or three wire control IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) Protection Control the total motor starter solution providing numerous functionality to control starting and stopping and protection of motor as well as application 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal speed as quickly as possible. This draws maximum current from the power supply and accelerates the application with its maximum torque. Depending on the application, this can cause different problems. Applications like pumps, conveyers, centrifuges and bandsaws must be started slowly, and sometimes stopped slowly, to prevent mechanical shocks such as water hammer, and strains on bands, couplings and shafts. 00 0. kw @ 00V 08 600V mains voltage 80 V AC/DC control voltage 00 Start/stop 0 Built in bars for easy connection of bypass contactor. All motor protection functions are retained in bypass mode Inside delta wiring kit ( kw) Automatic reset function Password parameter protection Trip log function IP ( kw @ 00V) IP 0 (85 kw @ 00V) Advantages of ing over Star/ Delta and Auto transformer starting Torque Soft Starters are a far better alternative to star/delta and auto transformer starters. The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. Furthermore star/ does not always allow selection of the best start current level. This sometimes means the load cannot accelerate to full speed in star configuration thereby making the star/delta starter totally ineffective. A star/delta starter does not impact the way the motor stops, thus leaving the voltage ramp down with no control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters do not however eliminate the risk of a jump in torque when shifting voltage. Soft Starter xtn Auto transformer Star/Delta DOL TN Current 6xIN IN Benefits: Pumps Reduced hydraulic shocks in pipelines during start and stop Minimized mechanical stress on motor shaft Reduced starting current Undercurrent protection preventing damage from blocked pipe or low water situations (00) Automatic reset functionality ensures continued operation of unmanned pump stations (00) Phase rotation protection prevents damage from reverse pump rotation (0 and 00) Instantaneous overload protection prevents damage from debris drawn into the pump (0 and 00) Conveyors Controlled start without mechanical shocks causing damage to products and application Minimized belt stretch. Reduced counter balance stress Controlled stop without mechanical shocks Optimum soft start even with varying starting loads, e.g. coal conveyors starting loaded or unloaded (0 and 00) Extended mechanical lifetime Compressors Reduced mechanical shocks extend the life of the compressor, couplings and motor Limited start current enables large compressors to be started even when maximum power capacity is limited Phase rotation protection prevents operation in reverse direction (0 and 00) Instantaneous overload protection prevents possible damage from liquid ammonia entering the compressor screw (0 and 00) Fans Smooth application of torque Reduced starting times over star/ Centrifuges Smooth application of torque Reduced starting times over star/ Reduced stopping times thanks to DC brake and soft braking (00) Band saws Reduced time for saw band replacements since the soft braking function stops the motor quickly (00) Extended saw band life thanks to eliminated torque shocks during start Easier saw band alignment. Slow acceleration allows saw bands to be tracked without jogging Maximum overload capability available for ridethrough of operating overloads (00) The motor thermal model (0 and 00) accounts for the actual overload capability of the connected motors and will trip only if absolutely necessary.

Type Concept VLT Soft Start Controller 00 VLT Soft Start Controller 00 0 A true fit and forget soft starter for DIN rail mount 00 provides basic soft start and stop function a physically compact starter physically similar to providing basic soft start and 0 but providing enhanced soft start functionality and stop functionality various motor protection functionality s Motor protection 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Enhanced soft start and soft stop Motor and system protection kw @ 00V 00 6V mains voltage 0 00V AC control supply Timed voltage rampup Adjustable start torque Selectable kickstart function Timed voltage rampup Adjustable initial torque Initial current rampup Initial current rampup Torque control Torque boost Dual parameter function Timed voltage rampdown Principle of Phase Angle Control A soft starter is an electronic device that regulates the voltage to the motor and this provides a smooth transition from standstill to full speed operation of the application. s all use the principle of phase angle control.: Backtoback coupled thyristors ramp up the motor voltage. In some s current transformers measure the motor current providing feedback for starting current control but also for numerous motor and application protection functions. s cover a comprehensive range ing and stopping can be controlled in a number of ways depending on the application. Some applications require nonlinear voltage rampup and the voltage ramp is therefore related to the actual current drawn. Conversely, a bandsaw usually requires a quick stop function provided by a DC brake. Then again, a number of applications require a kickstart torque for an instantaneous period of time followed by a soft rampup acceleration. s cover all of these applications and much more. 00: Micro Soft Start Controller for motors up to kw with heavy ratings as standard Unlimited number of starts per hour Contactor style design for easy selection, installation and commissioning 00: Compact Soft Starter for motors up to 0kW Voltage ramps, current limit start and intregrated motor protection Integral bypass design reduce heat dissipation Wide power range with advanced accessory modules 00: Fully featured Soft Starter for motors up to kw Total motor starting solution Advanced start, stop and protection features Local programming keypad and display Timed voltage rampdown Outputs Other features Universal two wire control Programmable via rotary for unlimited number of starts per hour LED indication IP 0 Timed voltage rampdown Linear voltage rampdown Three autoadjustable voltage ramps DC brake function Soft brake function Motor overload (adjustable trip class) Excess start time Reverse phase rotation Motor thermistor input Shorted SCR no start Supply fault no start As 0 + Under current Instantaneous overload Starter overtemperature Restart delay Warning before trips Adjustable phase imbalance sensitivity One output relay: Two output relays: Three output relays: DC brake contactor Programmable via rotary Programmable via 8 rotary Local key pad Buttons for start, stop, reset and remote control Inputs for two or three wire control IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) Protection Control the total motor starter solution providing numerous functionality to control starting and stopping and protection of motor as well as application 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal speed as quickly as possible. This draws maximum current from the power supply and accelerates the application with its maximum torque. Depending on the application, this can cause different problems. Applications like pumps, conveyers, centrifuges and bandsaws must be started slowly, and sometimes stopped slowly, to prevent mechanical shocks such as water hammer, and strains on bands, couplings and shafts. 00 0. kw @ 00V 08 600V mains voltage 80 V AC/DC control voltage 00 Start/stop 0 Built in bars for easy connection of bypass contactor. All motor protection functions are retained in bypass mode Inside delta wiring kit ( kw) Automatic reset function Password parameter protection Trip log function IP ( kw @ 00V) IP 0 (85 kw @ 00V) Advantages of ing over Star/ Delta and Auto transformer starting Torque Soft Starters are a far better alternative to star/delta and auto transformer starters. The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. Furthermore star/ does not always allow selection of the best start current level. This sometimes means the load cannot accelerate to full speed in star configuration thereby making the star/delta starter totally ineffective. A star/delta starter does not impact the way the motor stops, thus leaving the voltage ramp down with no control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters do not however eliminate the risk of a jump in torque when shifting voltage. Soft Starter xtn Auto transformer Star/Delta DOL TN Current 6xIN IN Benefits: Pumps Reduced hydraulic shocks in pipelines during start and stop Minimized mechanical stress on motor shaft Reduced starting current Undercurrent protection preventing damage from blocked pipe or low water situations (00) Automatic reset functionality ensures continued operation of unmanned pump stations (00) Phase rotation protection prevents damage from reverse pump rotation (0 and 00) Instantaneous overload protection prevents damage from debris drawn into the pump (0 and 00) Conveyors Controlled start without mechanical shocks causing damage to products and application Minimized belt stretch. Reduced counter balance stress Controlled stop without mechanical shocks Optimum soft start even with varying starting loads, e.g. coal conveyors starting loaded or unloaded (0 and 00) Extended mechanical lifetime Compressors Reduced mechanical shocks extend the life of the compressor, couplings and motor Limited start current enables large compressors to be started even when maximum power capacity is limited Phase rotation protection prevents operation in reverse direction (0 and 00) Instantaneous overload protection prevents possible damage from liquid ammonia entering the compressor screw (0 and 00) Fans Smooth application of torque Reduced starting times over star/ Centrifuges Smooth application of torque Reduced starting times over star/ Reduced stopping times thanks to DC brake and soft braking (00) Band saws Reduced time for saw band replacements since the soft braking function stops the motor quickly (00) Extended saw band life thanks to eliminated torque shocks during start Easier saw band alignment. Slow acceleration allows saw bands to be tracked without jogging Maximum overload capability available for ridethrough of operating overloads (00) The motor thermal model (0 and 00) accounts for the actual overload capability of the connected motors and will trip only if absolutely necessary.

Type Concept VLT Soft Start Controller 00 VLT Soft Start Controller 00 0 A true fit and forget soft starter for DIN rail mount 00 provides basic soft start and stop function a physically compact starter physically similar to providing basic soft start and 0 but providing enhanced soft start functionality and stop functionality various motor protection functionality s Motor protection 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Enhanced soft start and soft stop Motor and system protection kw @ 00V 00 6V mains voltage 0 00V AC control supply Timed voltage rampup Adjustable start torque Selectable kickstart function Timed voltage rampup Adjustable initial torque Initial current rampup Initial current rampup Torque control Torque boost Dual parameter function Timed voltage rampdown Principle of Phase Angle Control A soft starter is an electronic device that regulates the voltage to the motor and this provides a smooth transition from standstill to full speed operation of the application. s all use the principle of phase angle control.: Backtoback coupled thyristors ramp up the motor voltage. In some s current transformers measure the motor current providing feedback for starting current control but also for numerous motor and application protection functions. s cover a comprehensive range ing and stopping can be controlled in a number of ways depending on the application. Some applications require nonlinear voltage rampup and the voltage ramp is therefore related to the actual current drawn. Conversely, a bandsaw usually requires a quick stop function provided by a DC brake. Then again, a number of applications require a kickstart torque for an instantaneous period of time followed by a soft rampup acceleration. s cover all of these applications and much more. 00: Micro Soft Start Controller for motors up to kw with heavy ratings as standard Unlimited number of starts per hour Contactor style design for easy selection, installation and commissioning 00: Compact Soft Starter for motors up to 0kW Voltage ramps, current limit start and intregrated motor protection Integral bypass design reduce heat dissipation Wide power range with advanced accessory modules 00: Fully featured Soft Starter for motors up to kw Total motor starting solution Advanced start, stop and protection features Local programming keypad and display Timed voltage rampdown Outputs Other features Universal two wire control Programmable via rotary for unlimited number of starts per hour LED indication IP 0 Timed voltage rampdown Linear voltage rampdown Three autoadjustable voltage ramps DC brake function Soft brake function Motor overload (adjustable trip class) Excess start time Reverse phase rotation Motor thermistor input Shorted SCR no start Supply fault no start As 0 + Under current Instantaneous overload Starter overtemperature Restart delay Warning before trips Adjustable phase imbalance sensitivity One output relay: Two output relays: Three output relays: DC brake contactor Programmable via rotary Programmable via 8 rotary Local key pad Buttons for start, stop, reset and remote control Inputs for two or three wire control IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) IP 0 ( kw @ 00V) IP 00 ( 0kW @ 00V) Protection Control the total motor starter solution providing numerous functionality to control starting and stopping and protection of motor as well as application 0kW @ 00V 00 5V mains voltage 0 0V AC or V AC/DC control supply Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal speed as quickly as possible. This draws maximum current from the power supply and accelerates the application with its maximum torque. Depending on the application, this can cause different problems. Applications like pumps, conveyers, centrifuges and bandsaws must be started slowly, and sometimes stopped slowly, to prevent mechanical shocks such as water hammer, and strains on bands, couplings and shafts. 00 0. kw @ 00V 08 600V mains voltage 80 V AC/DC control voltage 00 Start/stop 0 Built in bars for easy connection of bypass contactor. All motor protection functions are retained in bypass mode Inside delta wiring kit ( kw) Automatic reset function Password parameter protection Trip log function IP ( kw @ 00V) IP 0 (85 kw @ 00V) Advantages of ing over Star/ Delta and Auto transformer starting Torque Soft Starters are a far better alternative to star/delta and auto transformer starters. The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. Furthermore star/ does not always allow selection of the best start current level. This sometimes means the load cannot accelerate to full speed in star configuration thereby making the star/delta starter totally ineffective. A star/delta starter does not impact the way the motor stops, thus leaving the voltage ramp down with no control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters do not however eliminate the risk of a jump in torque when shifting voltage. Soft Starter xtn Auto transformer Star/Delta DOL TN Current 6xIN IN Benefits: Pumps Reduced hydraulic shocks in pipelines during start and stop Minimized mechanical stress on motor shaft Reduced starting current Undercurrent protection preventing damage from blocked pipe or low water situations (00) Automatic reset functionality ensures continued operation of unmanned pump stations (00) Phase rotation protection prevents damage from reverse pump rotation (0 and 00) Instantaneous overload protection prevents damage from debris drawn into the pump (0 and 00) Conveyors Controlled start without mechanical shocks causing damage to products and application Minimized belt stretch. Reduced counter balance stress Controlled stop without mechanical shocks Optimum soft start even with varying starting loads, e.g. coal conveyors starting loaded or unloaded (0 and 00) Extended mechanical lifetime Compressors Reduced mechanical shocks extend the life of the compressor, couplings and motor Limited start current enables large compressors to be started even when maximum power capacity is limited Phase rotation protection prevents operation in reverse direction (0 and 00) Instantaneous overload protection prevents possible damage from liquid ammonia entering the compressor screw (0 and 00) Fans Smooth application of torque Reduced starting times over star/ Centrifuges Smooth application of torque Reduced starting times over star/ Reduced stopping times thanks to DC brake and soft braking (00) Band saws Reduced time for saw band replacements since the soft braking function stops the motor quickly (00) Extended saw band life thanks to eliminated torque shocks during start Easier saw band alignment. Slow acceleration allows saw bands to be tracked without jogging Maximum overload capability available for ridethrough of operating overloads (00) The motor thermal model (0 and 00) accounts for the actual overload capability of the connected motors and will trip only if absolutely necessary.

.5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator kit. The operator (IP5/NEMA) is mounted on the cabinet front and allows remote control, status indication and motor monitoring of an individual using RS85 serial. It incorporates the following features: AC5b* (Amps) (mm) HxWxD 8A: 6: 5 5 A: 6: 5 8 0x98x6 A: 6: 5 8A: 6: 5 C 60A: 6: 5 0/ A: 6: 59 0 5xx9 85A: 6: 59 Ctick 00A: 6: 59 0A: 6: 59 0x0x 70A: 6: 59 00A: 6: 59 0 E.g. kw 0 kw 0 0 00 0 V 00 5 V 6 00 5 8 00 0 85 0 0 5 00 500 600 700 AC5a* (Amps) (mm) HxWxD 6A: 0: 500 8A: 0: 500 A: 0: 500 0A: 0: 500 5xx70 5A: 0: 500 70A: 0: 500 76A: 0: 500 00A: 0: 500 C 0A: 0: 500 59A: 0: 500 5x6x70 88A: 0: 500 Ctick 98A: 0: 500 5x96x70 99A: 0: 500 5A: 0: 500 5A: 0: 500 850xx80 5A: 0: 500 666A: 0: 500 78A: 0: 500 985A: 0: 500 86A: 0: 500 000x560x5 8A:0: 500 0 0 00 Serial V AC/DC 0 0V AC * Example: AC5b: A: 6: 5 starting current max. times FLC (A) in 6 seconds. 5 seconds minimum between starts. Start/stop, reset LED for start, run, trip Trip codes Current display Motor temp. display 0 ma output T C V IP5/NEMA 0 and 0 come with optional plugin modules for serial. DeviceNet Profibus Modbus RTU ASi* Optional modules are available for serial with 00: DeviceNet Profibus Modbus RTU (*as of May 005) E.g. kw kw Constant effort to improve 00 V 00 6 V The focus is clear at Danfoss: as a leading supplier of drives solutions throughout the world, we have spent years accumulating our technological and application knowhow. Danfoss drives have been produced since 968 and Danfoss Bauer geared 5 7 Enclosure Bookstyle IP ( 07) Compact IP () Compact IP0 (85) B C C0 motors since 97. Today, a long list of references indicates that the name of Danfoss is widely accepted as being synonymous with excellent quality and operational security. We have focused our professional resources on just one techno logical area for years: drives solutions. Years of applying these resources to industrial production lines have given us a wealth of experience and expertise. The results speak for themselves. Danfoss has enjoyed great success, and we are proud of what we do. 0 V AC 00V AC * Example: AC5a: 70A: 0: 500 Starting current max. times FLC (70A) in 0 seconds 50% on load duty cycle and max. 0 starts per hour. 00, 0, 0, 00 s in tables above are for max. 0 C ambient temperature. For other ratings contact Danfoss. DKDD.PB.06.B.0 VLT is a trademark of Danfoss A/S www.simpatico.dk.00.

.5 00 (mm)hxwxd (Amps) 0x,5x, CSA, A: :0 (AC5b) 5A: 8:0000 0xx8 5A: 65:0080 0xx8 0 T C V Remote operation Series + protection Remote operation of 0, 0 and 00 is facilitated by the dedicated remote operator kit. The operator (IP5/NEMA) is mounted on the cabinet front and allows remote control, status indication and motor monitoring of an individual using RS85 serial. It incorporates the following features: AC5b* (Amps) (mm) HxWxD 8A: 6: 5 5 A: 6: 5 8 0x98x6 A: 6: 5 8A: 6: 5 C 60A: 6: 5 0/ A: 6: 59 0 5xx9 85A: 6: 59 Ctick 00A: 6: 59 0A: 6: 59 0x0x 70A: 6: 59 00A: 6: 59 0 E.g. kw 0 kw 0 0 00 0 V 00 5 V 6 00 5 8 00 0 85 0 0 5 00 500 600 700 AC5a* (Amps) (mm) HxWxD 6A: 0: 500 8A: 0: 500 A: 0: 500 0A: 0: 500 5xx70 5A: 0: 500 70A: 0: 500 76A: 0: 500 00A: 0: 500 C 0A: 0: 500 59A: 0: 500 5x6x70 88A: 0: 500 Ctick 98A: 0: 500 5x96x70 99A: 0: 500 5A: 0: 500 5A: 0: 500 850xx80 5A: 0: 500 666A: 0: 500 78A: 0: 500 985A: 0: 500 86A: 0: 500 000x560x5 8A:0: 500 0 0 00 Serial V AC/DC 0 0V AC * Example: AC5b: A: 6: 5 starting current max. times FLC (A) in 6 seconds. 5 seconds minimum between starts. Start/stop, reset LED for start, run, trip Trip codes Current display Motor temp. display 0 ma output T C V IP5/NEMA 0 and 0 come with optional plugin modules for serial. DeviceNet Profibus Modbus RTU ASi* Optional modules are available for serial with 00: DeviceNet Profibus Modbus RTU (*as of May 005) E.g. kw kw Constant effort to improve 00 V 00 6 V The focus is clear at Danfoss: as a leading supplier of drives solutions throughout the world, we have spent years accumulating our technological and application knowhow. Danfoss drives have been produced since 968 and Danfoss Bauer geared 5 7 Enclosure Bookstyle IP ( 07) Compact IP () Compact IP0 (85) B C C0 motors since 97. Today, a long list of references indicates that the name of Danfoss is widely accepted as being synonymous with excellent quality and operational security. We have focused our professional resources on just one techno logical area for years: drives solutions. Years of applying these resources to industrial production lines have given us a wealth of experience and expertise. The results speak for themselves. Danfoss has enjoyed great success, and we are proud of what we do. 0 V AC 00V AC * Example: AC5a: 70A: 0: 500 Starting current max. times FLC (70A) in 0 seconds 50% on load duty cycle and max. 0 starts per hour. 00, 0, 0, 00 s in tables above are for max. 0 C ambient temperature. For other ratings contact Danfoss. DKDD.PB.06.B.0 VLT is a trademark of Danfoss A/S www.simpatico.dk.00.