APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

Similar documents
Applicant: INTEX DEVELOPMENT COMPANY LTD. Date: Jul 14, /F, DAH SING FINANCIAL CENTRE,108 GLOUCESTER ROAD,WANCHAI, HONG KONG.

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

Test Report. On Behalf of CHANGZHOU AIRWHEEL TECHNOLOGY CO.,LTD. AIRWHEEL WHEELCHAIR H3,H3S,H3P,H3PS,H3T,H3TS

POL. IND. LA VARIANTE. MONTE LA PILA, LARDERO (LA RIOJA) SPAIN Marta Montero Product Name:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

Name of Laboratory : SGS CAMBODIA LABORATORY Accreditation Number : Testing : 1076 A-C, Street 371, Sangkat Stung Meanchey, Khan Meanchey,

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

Technical Report No D Dated

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

: JUSTFOG DONGGUAN CO., LTD. BLDG, 3, DASHADUN INDUSTRIAL PAPK, WUSHAJIANGBEI VILLAGE, CHANG AN TOWN, DONGGUAN. SUMMARY OF TEST RESULTS

Technical Report No C Dated

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Technical Report No A Dated

Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

SHENZHEN TIMEWAY TESTING LABORATORIES

TAI FAT BAKELITE INDUSTRIAL LTD.

Test Report No. C Date: Sep 14, 2016 Page 1 of 11

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

ADDRESS : 5/F., NO NAIYAN RD, JIAOJIANG, TAIZHOU, ZHEJIANG, CHINA. TURN AROUND TIME : 19-Jun-2012 to 25-Jun-2012, 4 working days

Technical Report No A Dated

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

Technical Report No B Dated

: SHENZHEN INNOKIN TECHNOLOGY CO., LTD BUILDING 6,XINXINTIAN INDUSTRIAL PARK, XINSHA ROAD, SHAJING,BAOAN DISTRICT,SHENZHEN, CHINA

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO.,LTD

Safety and Quality 2.0 Bike Specifications

: PARTICLE INDUSTRIES, INC 126 POST ST, 4TH FLOOR, SAN FRANCISCO, CA USA SUMMARY OF TEST RESULTS

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

SUMMARY OF TEST RESULTS

APPLICANT : FLASHBAY ELECTRONICS BLDG B&C XI FENG CHENG IND ZONE, NO. 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN SUMMARY OF TEST RESULTS

TECHNICAL INFORMATION

MANUFACTURER : FLASHBAY ELECTRONICS BLGD B&C XI FENG CHENG IND ZONE, NO. 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN

Technical Report No A Dated

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

EN 1154:1997 / A1:2002

Page 2 of 23 UNT150420C11

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Technical Report No A Dated

FLASHBAY ELECTRONICS

Applicant: NEAT-OH! INTERNATIONAL, LLC Date: Jul 07, W FRONTAGE ROAD SUITE 303 NORTHFIELD IL USA Attn: ELAN FELDMAN

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

Emissions Testing Report

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Technical Report No Rev. 00 Dated

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

APPLICANT : FLASHBAY ELECTRONICS BLDG B&C XI FENG CHENG IND ZONE, NO.2 FU YUAN ROAD HE PING, VILLAGE, FU YONG TOWN, SHENZHEN

Amendment to Test Report

PASS TEST REPORT OVERALL RESULT: At the request of the client, the following tests were conducted:

Supplier s Product Safety Warranty (EU)

PASS. Vincent Chow Wai Kit Manager, Chemical Laboratory

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Town, DongGuan City, Guangdong Test specification :

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

SUMMARY OF TEST RESULTS

List of Attachments (including a total number of pages in each attachment):

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

4 A village survey: Mandari, Lakshmipur

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

Laboratory Bureau Veritas Consumer Products Services Lanka (Pvt.) Ltd., No. 570, Galle Road, Katubedda, Moratuwa, Sri Lanka

Report No.: STR S. ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3

IECEx Certificate of Conformity

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

SGS Australia Pty Ltd

Installation Couplers intended for permanent connection in fixed installation

TRACE ELEMENTS IN URINE

Experiences with domestic waste treatment and co-processing of Solid Recovered Fuels (SRF)

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Discipline Chemical Testing Issue Date Certificate Number T-1695 Valid Until Last Amended on - Page 1 of & 2013.

SEPA Statement Processed Fuel Oil

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT Test Report # 17A E Date of Report Issue: April 24, 2017 Date of Sample Received: April 14, 2017 Pages: Page 1 of 8

Proposed Sydport Container Terminal-Sydney Harbour Sediment Quality Analysis

TRACE ELEMENTS IN WHOLE BLOOD. Event #2, 2010

FLASHBAY ELECTRONICS

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

LIA Laboratories Limited

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

TEST REPORT IEC 61427:2005 Secondary cells and batteries for photovoltaic energy systems (PVES) General requirements and methods of test

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

APPLICANT : FLASHBAY ELECTRONICS BLDG B&C XI FENG CHENG IND ZONE, NO 2 FUYUAN ROAD HE PING, VILLAGE, FUYONG TOWN, SHENZHEN,CHINA

Obtaining ASTM D6400- D6868 Approval

Variation Notice with introductory note

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

SEM.Test Compliance Service Co., Ltd

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Presentation to: Cedar Hills City Council Division of Water Quality Utah Department of Environmental Quality

AS/NZS AS/NZS

Test Report issued under the responsibility of:

COVER PAGE FOR TEST REPORT

Test Result No.1. Lead (Pb) % ND See comment if > Cadmium (Cd) % ND Mercury (Hg) % ND

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

Melos Infill EPDM ST. Made for top performances: Infill Granules by Melos. »Our aim: Infill granules for the perfect artificial turf system«

TRACE ELEMENTS IN URINE. Event #3, 2012

IECEx Certificate of Conformity

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Transcription:

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of Nanjing Feeling Rubber & Plastic Produces Co., Ltd EPDM Rubber Granule Prepared For : Nanjing Feeling Rubber & Plastic Produces Co., Ltd QIAOLIN INDUSTRIAL PARK, LANHUA ROAD NO.11, PUKOU DISTRICT, NANJING, CHINA Prepared By : U.K.: Flat 107, 25 Indescon Square, London, United Kingdom China: 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao an Dist, Shenzhen, China Date of Test : May.24-30,2016 Date of Report : May.31,2016 Report Number : B-S16059897 Page 1 of 6

Safety of Toys Report EN 71 Part 3: Migration of certain elements Testing laboratory : Address : Report body........: Address (U.K.)....: Address (China).....: Applicant : Address...: Client No..: 00254186 China: 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao an Dist, Shenzhen, China Flat 107, 25 Indescon Square, London, United Kingdom China: 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao an Dist, Shenzhen, China Nanjing Feeling Rubber & Plastic Produces Co., Ltd QIAOLIN INDUSTRIAL PARK, LANHUA ROAD NO.11, PUKOU DISTRICT, NANJING, CHINA Standard : Test Result : Non-standard test method..: Type of test object.: Trademark...: Model/type reference : Manufacturer..: Address : EN 71-3: 2013+A1:2014 Compliance with EN 71-3: 2013+A1:2014 N.A. EPDM Rubber Granule N.A. N.A Nanjing Feeling Rubber & Plastic Produces Co., Ltd. QIAOLIN INDUSTRIAL PARK, LANHUA ROAD NO.11, PUKOU DISTRICT, NANJING, CHINA Page 2 of 6

Possible test case verdicts : test case does not apply to the test object.. : N(.A.) test object does meet the requirement. : P(ass) test object does not meet the requirement. : F(ail) Name and address of the testing laboratory:. 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao an Dist, Shenzhen, China Reported by : Signature / Rocky Date May.31,2016 Checked by : May.31,2016 Signature / Apollo Date Approved by : May.31,2016 Signature / Bruce Date Page 3 of 6

General remarks: "(see remark #)" refers to a remark appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. Attached with: 1. photo documentation. Remark: The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Page 4 of 6

EN 71-3 Clause Requirement Test Result - Remark Verdict Test value form of element migration from EPDM Rubber Granule Results according to EN 71-3: 2013+A1:2014-Migration of certain elements Category I Category II Category III Elements Limit Result Limit Result Limit Result Aluminium 5625 N.A. 1406 BL 70000 BL Antimony) 45 N.A. 11.3 BL 560 BL Arsenic 3.8 N.A. 0.9 BL 47 BL Barium (Cd) 1500 N.A. 375 BL 18750 BL Boron 1200 N.A. 300 BL 15000 BL Cadmium 1.3 N.A. 0.3 BL 17 BL Chromium(III) 37.5 N.A. 9.4 BL 460 BL Chromium(VI) 0.02 N.A. 0.005 BL 0.2 BL Cobalt 10.5 N.A. 2.6 BL 130 BL Copper 622.5 N.A. 156 BL 7700 BL Lead 13.5 N.A. 3.4 BL 160 BL Manganese 1200 N.A. 300 BL 15000 BL Mercury 7.5 N.A. 1.9 BL 94 BL Nickel 75 N.A. 18.8 BL 930 BL Selenium 37.5 N.A. 9.4 BL 460 BL Strontium 4500 N.A. 1125 BL 56000 BL Tin 15000 N.A. 3750 BL 180000 BL Organic tin 0.9 N.A. 0.2 BL 12 BL Zinc 3750 N.A. 938 BL 46000 BL NOTE: (Results shown are of the total weight on samples) BL= Below Limit N.A.= Not Applicable -mg/kg = Milligram per Kilogram Based On Dry Weight of Sample Page 5 of 6

EN 71-3 Clause Requirement Test Result - Remark Verdict Toy material categories Toy Material Category I Category II Category III Coatings of paints, varnishes, lacquers, printing - - Y inks, polymers, foams and similar coatings Polymeric and similar materials, including - - Y laminates, whether textile reinforced or not, but excluding other textiles Paper and paper board - - N Textiles, whether natural or synthetic - - N Glass, ceramic, metallic materials - - N Other materials whether mass coloured or not - - N (e.g. wood, fibre board, hard board, bone and leather) Compressed paint tablets, materials intended to N - - leave a trace or similar materials in solid form appearing as such in the toy (e.g. the cores of colouring pencils, chalk, crayons) Pliable modelling materials, including modelling N - - clays and plaster [3] Liquid paints, including finger paints, varnishes, - N - lacquers, liquid ink in pens and similar materials in liquid form appearing as such in the toy (e.g., slimes, bubble solution) Glue sticks - N - Note: Y meas Contain such substances N meas Not Contain such substances - meas Not belong to this class material Page 6 of 6

Appendix 1 Photo view of EPDM Rubber Granule