Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Similar documents
Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-43 Extruded Airfoil Blade Control Damper

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

VCD-23 Low Leakage CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

VCD-23. Flange Options. Size Limitations

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Thermal Isolation. Break

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-331 Combination Fire Smoke Dampers

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

HCD-230 Industrial Control Damper

HVAC Control & Balancing Dampers

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

HVAC Control & Balancing Dampers

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Air Measuring Products AMD AMS IAQ

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

ID-141x 12-Gauge Hat Channel Industrial Damper

LOW LEAKAGE VOLUME CONTROL DAMPER

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

BD-1600 Balancing/Zone Control Damper

Series HCD Airfoil Control Damper

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

ARROW INDUSTRIAL PRODUCTS

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Motorized Fire Dampers

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Blast Protection Damper

Blast Protection Damper

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS WE CONTROL AIR

SECTION CONTROL DAMPERS

VD-1600 Series Volume Control Dampers

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

Installation, Operation and Maintenance Manual

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

VOLUME CONTROL DAMPER

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

L O U V E R S & D A M P E R S

When Time is Everything... We Manufacture in Days - Not Weeks!

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

Fusible Link (replaceable) Horizontal Mount

ARROW UNITED INDUSTRIES

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Installation, Operation, and Maintenance Instructions

RM-1200 Slim Round Control Damper

Fusible Link (replaceable) Horizontal Mount

Introduction to Johnson Controls Dampers

Smoke Dampers. Installation Instructions

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

CFSD Series. Product Description

Installation, Operation and Maintenance Manual

PC-125x Counter-Balanced Backdraft Damper

AIR DUCT ACCESSORIES

SMOKE DAMPER - CLASS F MODEL BMSD

AD-1250 Airflow Measuring Station

Transcription:

Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also IECC (International Energy Conservation Code) compliant with a leakage rating of 3 cfm/ft 2 @ 1 in. wg (55 cmh/m 2 @.25 kpa) or less. Ratings (See page 3 for specific limitations) Pressure: 10 in. wg (2.5 kpa) - pressure differential Velocity: Up to 4000 (20.3 m/s) Leakage: Class 1A @ 1 in. wg (.25 kpa) Class 1 @ 4 in. - 10 in. wg (1 kpa - 2.5 kpa) Temperature: Up to 250 F (121 C). Consult Greenheck for higher temperatures. Model Low Leakage Insulated Airfoil CONTROL DAMPER Standard Construction Optional Construction Frame Material Galvanized steel 304SS or Painted Frame Material Thickness Frame Type 16 ga. (1.5mm) 12 ga. (2.7mm) 5 in. x 1 in. (127mm x 25mm) hat channel Single flange Single Reversed flange Double flange Blade Action Opposed Parallel Blade Material Galvanized steel 304SS or Painted Blade Material Thickness 2 skins of 20 ga. (1mm) Blade Type Insulated Airfoil - Linkage Plated steel out of airstream Axle Bearings Synthetic (acetal) 304SS Axle Material Plated steel - Blade Seals TPE Silicone Jamb Seals 304SS - Paint Finishes - Baked Enamel, Epoxy, Hi Pro Polyester Size Limitations W x H Minimum Maximum Size Size Single Section Multiple Section Inches 10 x 6 60 x 74 Unlimited mm 254 x 152 1524 x 1880 Unlimited - - Flange Options 13/8 in. Max. 13/8 in. 13/8 in. Max. Max. W* * W&H dimension furnished approximately 1/4 in. (6mm) undersize. Shown with optional extension pin and standoff bracket. 5 in. 5 in. 5 in. Single Flange Blade Operation 1 1/2 in. (Typical) Reversed Flange Shown with optional internally mounted actuator. 13/8 Max. in. H* Double Flange Features & Options Double skin blades filled with 1 2 in. (13mm) fiberglass insulation for improved thermal insulation. Airfoil shape reduces pressure drop and turbulence at velocities to 4000 (20.3 m/s). Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. (432mm) high. Actuators (120V, 24V, 230V, Pneumatic or Manual Quadrant) OCI (Open Close Indicator) 5" 5" Parallel Blades Opposed Blades Installation instructions available at www.greenheck.com.

Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

AMCA Certified Data Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. AMCA 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 1000 0.03 1000 0.03 1000 0.02 1500 0.07 1500 0.06 1500 0.04 2000 0.13 2000 0.10 2000 0.07 2500 0.19 2500 0.15 2500 0.11 3000 0.26 3000 0.21 3000 0.15 3500 0.35 3500 0.28 3500 0.20 4000 0.45 4000 0.36 4000 0.26 12 in. x 48 in. (305mm x 1219mm) 1000 0.03 1500 0.07 2000 0.11 2500 0.17 3000 0.23 3500 0.31 4000 0.39 48 in. x 12 in. (1219mm x 305mm) 1000 0.02 1500 0.04 2000 0.08 2500 0.12 3000 0.16 3500 0.21 4000 0.27 AMCA 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 1000 0.02 1000 0.01 1000 0.01 1500 0.05 1500 0.03 1500 0.02 2000 0.08 2000 0.05 2000 0.04 2500 0.12 2500 0.09 2500 0.06 3000 0.17 3000 0.13 3000 0.08 3500 0.23 3500 0.17 3500 0.12 4000 0.30 4000 0.22 4000 0.15 12 in. x 48 in. (305mm x 1219mm) 1000 0.02 1500 0.04 2000 0.08 2500 0.12 3000 0.17 3500 0.22 4000 0.29 48 in. x 12 in. (1219mm x 305mm) 1000 0.02 1500 0.04 2000 0.07 2500 0.11 3000 0.15 3500 0.20 4000 0.25 AMCA 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 500 0.03 500 0.03 500 0.02 1000 0.12 1000 0.11 1000 0.09 1500 0.27 1500 0.26 1500 0.21 2000 0.48 2000 0.45 2000 0.38 2500 0.74 2500 0.71 2500 0.58 3000 1.07 3000 1.02 3000 0.85 3500 1.46 3500 1.40 3500 1.15 4000 1.91 4000 1.89 4000 1.52 12 in. x 48 in. (305mm x 1219mm) 500 0.03 1000 0.11 1500 0.24 2000 0.43 2500 0.67 3000 0.96 3500 1.31 4000 1.71 48 in. x 12 in. (1219mm x 305mm) 500 0.03 1000 0.11 1500 0.24 2000 0.44 2500 0.68 3000 0.97 3500 1.32 4000 1.73

AMCA Certified Leakage Air leakage is based on operation between 32 F (0 C) and 120 F (49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data are based on a torque of 7.0 in.lb./ft² (0.79 N m) applied to close and seat the damper during the test. Maximum Damper Width 60 in. (1524mm) Leakage Class 1 in. wg 4 in. wg 8 in. wg (0.25 kpa) (1 kpa) (2 kpa) 10 in. wg (2.5 kpa) 1A 1 1 1 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. *Leakage Class Definitions The maximum allowable leakage is defined by AMCA as the following: Leakage Class 1A - 3 cfm/ft 2 @ 1 in. wg (class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 2 @ 1 in. wg - 8 cfm/ft 2 @ 4 in. wg - 11 cfm/ft 2 @ 8 in. wg - 12.6 cfm/ft 2 @ 10 in. wg Velocity Limitations 74 60 Damper Height (in.) 48 36 24 4000 3500 3000 2500 12 0 0 12 24 36 48 Damper Width (in.) 60

Space Envelopes On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. Damper frame T D Optional Jackshaft B Actuator Type/Model Height T B D AFBUP (-S) and FSNF Series, Belimo MSxx20 Series, Honeywell; 33x- 2976 Series, Siemens FSLF, LF and TFB Series, Belimo MSxx04 & MSxx09 Series, Honeywell MS75xx Series, Honeywell 33x-4551 Series, Siemens 331-2856, Siemens Inches (mm) Inches >6 to <10 0 12 3 4 6 >10 to <18 0 2 6 >18 0 0 10 >6 to <10 0 3 1 2 6 >10 0 0 6 >6 to <9 0 4 3 4 6 >9 0 0 6 >6 to <10 0 12 3 4 6 >10 to <18 0 7 6 >18 0 0 6 >6 to <10 0 7 1 2 6 >10 to <17 0 1 1 2 6 >17 0 0 6 <12 N/A N/A N/A >12 to <18 0 2 1 2 10 >18 0 0 10 This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. Internal mount only Actuator model All except - EFB & EFCX Series A B C 7.75 in (197 mm) 3.75 in (95 mm) 5.375 in (136.5 mm) A B EFB & EFCX Series 8.50 in (216 mm) 6.00 in (152mm) 8.50 in (216 mm) Actuator Mounting External - includes extension pin (standoff bracket optional) External kit - actuator and all mounting hardware Internal - blade lever C 5"

Assemblies Specifications Multi-Section Assembly Dampers larger than the maximum single section size, will be made up of a multiple of equal size sections. Multiple section dampers can be jackshafted together so that all sections operate together as shown below. NOTE: Dampers larger than 60 in. x 74 in. (1524mm x 1880mm) are not intended to be structurally self supporting. Additional horizontal bracing is recommended to support the weight of the damper and vertical bracing should be installed as required to hold against system pressure. Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall consist of: a 16 ga. (1.5mm) galvanized steel channel frame with 5 in. (127mm) depth; airfoil shaped, galvanized steel double skin construction blades (2 skins of 20 ga. [1mm]) filled with 1 /2 in. (13mm) polystyrene; blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper; 1 /2 in. (13mm) dia. plated steel axles turning in synthetic (acetal) sleeve bearings; TPE blade seals for 200 F (93 C) maximum temperature; flexible stainless steel jamb seals; and external (out of the airstream) blade-to-blade linkage. Damper manufacturer's printed application and performance data including pressure, velocity and temperature limitations shall be submitted for approval showing damper suitable for pressures to 10 in. wg (2.5 kpa), velocities to 4000 (20.3m/s) and temperatures to 250 F (121ºC). Damper manufacturer's submittal data shall certify all air leakage and air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test figures 5.2, 5.3 and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Basis of design is Greenheck model. Copyright 2018 Greenheck Fan Corporation Rev. 16 August 2018