CLOUDBOX Quick Start Guide

Similar documents
Remote Keyless Entry Installation Guide ca 2051

Security and Keyless Entry Installation Guide ca 1051

Smart Wi-Fi Sprinkler Timer and Flow Meters

6500DC Dual Motor Wireless Controller Kits

Engineering Standards. Engineering Standard Number C A. Name. Digital Breathing Air Remaining System BREATHING AIR

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

Flight Systems. Replacement for KASSEC DESCRIPTION

TIME REQUIREMENT GUIDE (TRG)

G3 LOW PROFILE AIRPOT BREWER

JRVCS105 TROUBLESHOOTING GUIDE

Installation Instructions & Users Manual

e-ask electronic Access Security Keyless-entry

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

INSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN

Hi-Z USB Wireless. Introduction/Welcome

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

JRVCS2 TROUBLESHOOTING

Installation Instructions TRACKNET TN-4003/4004

SAFE & SECURE ACTUATOR PRODUCT MANUAL

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALL GUIDE FLCI-IDS(RS)-BZ4-[FLRSBZ4]-EN

Units with pedestal and busbars on the short side (+H360, flat mounting)

QUICK INSTALLATION GUIDE

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Installation and Operations Manual

Senior Swing Control Box. Table of Contents

An ISO 9001:2008 Registered Company

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

SmartLock Fifth Wheel

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

USERS GUIDE LO-21U LOCKOUT RELAY

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

SST-3 Start-Stop-Throttle

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

Alarms & Remote Start

SCM-Power Distribution PLUS system Installation and User Instructions:

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

Engineering Standards. Engineering Standard Number C A. Name. Digital Oxygen Remaining System O2 REMAINING

Standby Generator Quick Reference Guide

Model AS-9234E. Owners Guides

Model PRO 9246CH Installation Manual

INSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO

install guide COM-IDS(RS)-BM1-[ADS-BM1]-EN

MapDCCD advanced WSS processor Installation and user guide

INSTALL GUIDE AKX-IDS(RS)-BM1-[ADS-BM1]-EN

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR JET JLX SERIES LED LIGHT BARS

Toughsat T-100 Communications Trailer Users Manual

Flotection: Building Main Shutoff System

Magnetek DSD 412 Drive

FM SECURITY AND REMOTE START SYSTEM

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

INSTALL GUIDE IDL-IDS(RS)-BM1-[ADS-BM1]-EN

INSTALL GUIDE DIR-IDS(RS)-BM1-[FLRSBM1]-EN

SRM 7.0 Detailed Requisitioning

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

To get started with RLINK, install the RLINK Smart Device on your bike using this guide.

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

SHIVVERS ROTATION DETECTOR. fshiwersf ROTATION DETECTOR 676A-001A

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

Power Distribution System User s Manual. Model: PDS-100

PIM701 (Police Interface Module) Dodge Charger Pursuit

6000DC Single 12V Motor Wireless Controller Kits With Extra Options

Aftermarket Interface Module

Engineering Standards

Model AX-510 Owner s Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Installation and Operation Instructions 10/04/13

Electric Actuator Instructions

C-PIM701 (Police Interface Module) 2018 Dodge Charger Pursuit

Omega RS-110-DP OPERATION MANUAL BACK COVER PRINTER S NOTE: production back cover. is color; this is a place marker cover. FRONT COVER PRINTER S NOTE:

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

Water Specialist EE Control Valve Programming and Cover Drawing Manual

Chevy Truck

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

Liebert. FP 50Z kva

12V PROGRAMMABLE POWER OUT

AL-100DP Full-Feature Vehicle Security System for Factory-Equipped Remote Keyless Entry Transmitters Owner s Guide

Constant Voltage/Constant Current Test System

Adaptronic esel015 Select ECU for Nissan R32/R33/R34GTR Skyline and Z32 300ZX / Fairlady

INSTALLATION MANUAL. Model: PLUS Vehicle Security

POWER DOOR LOCKS 8P - 1 POWER DOOR LOCKS CONTENTS

OnCommand Troubleshooting Guide Hayward Industries

2 Way Security and Keyless Entry Installation Guide ca 1553

Installation Instructions

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

P0030, P0036, P0050, P0053, P0054, P0056, P0059, P0060, P0135, P0141, P0155, or P0161

RS4000 Setup. Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping.

Overview of operation modes

ADVANCED PID TROUBLESHOOTING

Transcription:

CLOUDBOX Quick Start Guide

Welcome to FuelCloud! This quick start guide will help you get your FuelCloud system installed. Important: Online setup must be complete in order to finish installation and test your system. If you are the account owner, please complete online setup prior to your installation date. Go to Fuelcloud.com and follow the on-screen prompts. Need Help? Videos and more information available at help.fuelcloud.com

Confirm online account has been setup Create an Account at FuelCloud.com The Setup Page will walk you through the all of the necessary steps and features to get your system going. A few of these steps are mandatory for installation, while others can be set up later. For install, here s what you need: 1. Add a Default Payment Method Tip: Go to Settings > Billing in the left navigation. 2. Add a Site Important: Ensure that the location address and coordinates for the site are correct. 3. Add a Tank Tip: For installation and testing purposes, just make sure you ve added a tank to your installation site all other details can be edited at anytime. 4. Add Hardware and Configure Relay Important: To test the app, your CloudBox must be activated and the relay must be configured to your tank.

2 Identify your installation location FuelCloud uses a wireless signal to communicate with the hardware, and your mobile device needs a line of site to the CloudBox to connect and unlock the pump. Select an installation site that is in visual range, and do not install the CloudBox inside or behind a metal / cement barricade.

3 Turn power off Turn off all power to the pump at the breaker. OFF ON 4 Mount Attach the 4 included Mounting Brackets and screws to the CloudBox. Use any available fasteners to mount the CloudBox. Included with CloudBox (4x)

5 Wiring FuelCloud piggybacks AC power off of the input. Your wiring configuration will depend on whether the pump runs on AC or DC power. AC: AC power has a 100-240VAC power range. For power input, attach the appropriate wires (L, N, G) to the designated terminals on the top bank of terminals on the left-hand side of the CloudBox circuit board. For power output, attach the appropriate wires to the designated terminal on the bottom bank of terminals on the left-hand side of the CloudBox circuit board. DC: DC power has a 8-50VDC power range. For power input, attach the appropriate wires (DC+ & DC-) to the designated terminals on the top bank of terminals on the left-hand side of the CloudBox circuit board. For power output, attach the appropriate wires to the designated terminals on the bottom bank of terminals on the left-hand side of the CloudBox circuit board. In addition to input and output power, 8-50VDC is needed to power the hardware. Note: A Class 2 power source is needed to power the DC portion of the hardware.

CLASS 2 WIRING TERMINAL DC- DC+ DC INPUT OUTPUT INPUT AC OUTPUT

6 Pulsers Warning: Do not attach AC power to the terminal marked 12V+. This terminal is for DC active pulsers only. Attaching AC power to this terminal will destroy your FuelCloud board. The wiring configuration for pulsers depends on whether you are using a 2-wire (passive) or a 3-wire (active) pulser. All pulser wiring should be connected to the bank of terminals on the left on the bottom of the FuelCloud board, as demonstrated in the graphic on the right. 2-Wire (Passive) Pulser: Note: for 2 wire pulsers, it doesn t matter which of the two wires you attach to each terminal. Attach one wire to the terminal marked Pulse. Attach one wire to the terminal marked GND. 3-Wire (Active) Pulser: Note: 3 wire pulser if pulser requires 12V DC power. Attach the pulser 12V power wire to the 12V+ terminal. Attach signal wire to the Pulse. Attach the ground wire to the GND terminal.

2 Wire (Passive) Pulser: FUELCLOUD PULSER Pulse Pulse 12v+ GND Pulse Level 3 Wire (Active) Pulser: FUELCLOUD PULSER Pulse 12v+ GND Signal 12v+ GND Level

7 Power On Turn the power back on at the breaker. Verify that the board lights up - a green LED on the right of the board should activate, a Status LED should move from flashing red to yellow. If no LEDs illuminate: Verify that the terminals are correctly wired for your power supply. Verify that there is power coming to the CloudBox. STATUS POWER

8 Test Open the FuelCloud mobile app and connect to your newly installed FuelCloud hardware. Note: if you cannot connect to your FuelCloud hardware and the unit has powered up correctly, verify that you have completed online setup appropriately. Toggle the bypass switch and verify that the pump can run in bypass mode. Check that the Pulse LED flashes when running in bypass mode. Check that the latest version of the FuelCloud app is installed.