HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Similar documents
HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Protistor size 70 gr 690VAC (IEC)

Protistor size 120 gr 750VDC (IEC)

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1)

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

HelioProtection Program

Limitor -G General Purpose Fuses

Semiconductor (AC) fuses

NH Solid Blades 690 VAC sizes 000 to 3

Special Purpose Fuses

URDC-PV. Features and Benefits FUSES. URPV Fuses for PV Semiconductor Protection. gpv. Class: Voltage ratings: 600V DC to 1500V DC.

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

NEOZED D0 fuse-links gg 400/440VAC

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

UltraSafe US22 Modular fuse-holders

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Modulostar US10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders

Complete and reliable solar circuit protection

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Bussmann series NH photovoltaic fuse links

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

AF40... AF96 3-pole contactors Technical data

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

LINOCUR Size D02 63A 230VAC/440VAC

fuse-links & fuse holders PHOTOVOLTAIC

MANUALLY OPERATED CHANGEOVER SWITCHES

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Semiconductor Fuses European Fuses

onlinecomponents.com

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

XL Photovoltaic fuse links

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

NH photovoltaic fuse links

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

PANEL PANEL MOUNTING COMPONENTS

EVpack-fuse MEV70 BATTERY PACK FUSES FEATURES & BENEFITS APPLICATIONS

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

INNOZED D0 fuse-bases with touch protection

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

Panel-mounting components

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIVERT 1000A Main Incomer, 690VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

Bussmann series NH catalogue. Leadership in circuit protection

DRX 100 B/N/H Circuit breaker (not adjustable)

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

Fuse holders and fuses

IEC Low Voltage General Purpose Protection

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Solar circuit protection application guide. Complete and reliable solar circuit protection

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Load Break Disconnect Switches FSLBS

Special Purpose Fuses

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

TAE pole Contactors

What you need to know. Â Conformity to standards

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

2013 JEAN MÜLLER Products

3 - Protection components Motor circuit-breakers

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Transcription:

SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection HP10NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gpv type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting. TECHNICAL DATA OVERVIEW Voltage DC 1000 VDC Ampere Range (A) 50... 250 A Size per Standard NH1 and NH2 Speed/Characteristic gpv I.R. DC (UL) 50 ka (L/R = 1ms) Global acceptance Low fault current interrupting capability Temperature cycle withstand capability Durable construction for enhanced system longevity High efficiency with low power losses Small footprint Available in two versions: Plain Blade & Direct Mounting APPLICATIONS All photovoltaic applications Inverter DC input protection Re-combiner applications (sub combiner, array combiner, master combiner) STANDARDS IEC 60269-6 UL 2579 RoHS compliance EP.MERSEN.COM 1

PRODUCT RANGE NH fuse links gpv 1000VDC Plain Blade size 1 Catalog Item Rated current In at 0.7xIn at In Width Package Weight HP10NH1GPV125 HP10NH1GPV50 Z1028283 50 A 4.6 W 11 W 39.5 mm 3 0.3 kg HP10NH1GPV63 A1028284 63 A 5.4 W 13 W 39.5 mm 3 0.3 kg HP10NH1GPV80 B1028285 80 A 6.1 W 15 W 39.5 mm 3 0.3 kg HP10NH1GPV100 C1028286 100 A 7.2 W 17 W 39.5 mm 3 0.3 kg HP10NH1GPV125 D1028287 125 A 7.4 W 18 W 39.5 mm 3 0.3 kg HP10NH1GPV160 E1028288 160 A 9.6 W 23 W 39.5 mm 3 0.3 kg NH fuse links gpv 1000VDC Direct Mounting size 1 Catalog Item Rated current In at 0.7xIn at In Width Package Weight HP10NH1GPV50B B1048663 50 A 4.6 W 11 W 39.5 mm 3 0.4 kg HP10NH1GPV63B C1048664 63 A 5.4 W 13 W 39.5 mm 3 0.4 kg HP10NH1GPV80B D1048665 80 A 6.1 W 15 W 39.5 mm 3 0.4 kg HP10NH1GPV100B E1048666 100 A 7.2 W 17 W 39.5 mm 3 0.4 kg HP10NH1GPV125B F1048667 125 A 7.4 W 18 W 39.5 mm 3 0.4 kg HP10NH1GPV160B G1048668 160 A 9.6 W 23 W 39.5 mm 3 0.4 kg NH fuse-links gpv 1000VDC Plain Blade size 2 Catalog Item Rated current In at 0.7xIn at In Width Package Weight HP10NH2GPV250 HP10NH2GPV250 Y1037620 250 A 12.9 W 31 W 51 mm 3 0.6 kg HP10NH2GPV200 X1037619 200 A 11.3 W 27 W 51 mm 3 0.6 kg HP10NH2GPV200B HPBB11PPRFS HPBB11PPR NH fuse-links gpv 1000VDC Direct Mounting size 2 Catalog Item Rated current In at 0.7xIn at In Width Package Weight HP10NH2GPV200B H1048669 200 A 11.3 W 27 W 51 mm 3 0.63 kg HP10NH2GPV250B J1048670 250 A 12.9 W 31 W 51 mm 3 0.63 kg NH fuse-bases for NH fuse-links gpv 1000VDC, size 1, 250A, single pole Catalog Item Power acceptance HPBB11PPRFS K1032916 32 W 8 kv HPBB11PPR A1030607 32 W 8 kv Rated impulse withstand voltage Uimp Cable termination M10 terminal screw M = 27-32Nm M10 terminal screw M = 27-32Nm Design Package Weight with touch protection, for DIN-rail or screw mounting (M8/M10, M = 14/17 Nm), for NH fuse links size 1 open design, for DIN-rail or screw mounting (M8/M10, M = 14/17 Nm), for NH fuse links size 1 3 0.71 kg 3 0.44 kg EP.MERSEN.COM 2

PRODUCT RANGE NH fuse-bases for NH fuse-links gpv 1000VDC, size 2, 315A, single pole Catalog Item Power acceptance Rated impulse withstand voltage Uimp Cable termination Design Package Weight HPBB21PPR HPBB21PPR C1037509 45 W 8 kv HPBB21PPRFS D1037510 45 W 8 kv %sm10 terminal screw M = 27-32Nm M10 terminal screw M = 27-32Nm open design, for DIN-rail or screw mounting (M8/M10, M = 14/17 Nm), for NH fuse links size 1 and 2 with touch protection, for DIN-rail or screw mounting (M8/M10, M = 14/17 Nm), for NH fuse links size 2 3 0.54 kg 3 0.81 kg HPBB21PPRFS NH Fuse handle for NH fuse links size 00-4 Catalog Item Size Design Package Weight NHHANDLE NHHANDLE P215592 00 to 4 without arm protection to DIN VDE 0636-2, DIN VDE 608-4 5/25 0.28 kg 08024.000000 X216105 00 to 4 with fire proof arm protection to DIN VDE 0636-2, DIN VDE 608-4 1 0.54 kg 08024.000000 EP.MERSEN.COM 3

TIME CURRENT CHARACTERISTIC CURVES Special purpose gpv fuse link size NH1 1000V 50-160A 10000 7000 5000 Pre-arcing time (s) 3000 2000 1000 700 500 300 200 100 70 50 30 20 a = 110 A2 = 0.8 B1 = 1.25 B2 = 0.7 Cf3 = 0.8 50 A 10 7 5 3 2 63 A 80 A 1 0.7 0.5 0.3 0.2 0.1 0.07 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 10 20 30 50 70 100 200 300 RMS value of prospective current (A) +/-10% 500 700 1000 2000 3000 100 A 125 A 160 A 5000 7000 10000 EP.MERSEN.COM 4

TIME CURRENT CHARACTERISTIC CURVES Special purpose gpv fuse link size NH2 1000V 200-250A 10000 7000 5000 3000 2000 Pre-arcing time (s) 1000 700 500 300 200 100 70 50 30 20 10 7 5 3 2 200 A 1 0,7 0,5 0,3 0,2 250 A 0,1 0,07 0,05 0,03 0,02 0,01 0,007 0,005 0,003 0,002 0,001 0,0007 0,0005 0,0003 0,0002 0,0001 100 200 300 500 700 1000 2000 3000 5000 7000 10000 RMS value of prospective current (A) +/-10% 20000 30000 50000 70000 100000 EP.MERSEN.COM 5

CORRECTION FACTOR Rated power dissipation at rated current fuse-link gpv NH1 1000V 125-160A 1 0,8 0,6 0,4 0,2 0 20 30 40 50 60 70 80 90 100 % rated current Correction factor for power dissipation EP.MERSEN.COM 6

Special purpose gpv fuse link size NH1 Plain Blade without trip indicator 68 ± 2,5 2,5 2,5 2,75 ± 0,1 24 +1 4 20 MINI (64,5) 40,5 +0,3 1,3 9,5 +1,5 0,5 52,5 ± 0,5 39,5 ± 0,4 (72,1) 6 ± 0,2 A B 100 +2.0 100±1.0-1.5 135 ± 2,5 EP.MERSEN.COM 7

Special purpose gpv fuse link size NH1 Direct Mounting without trip indicator and without lugs +0.7 25.5-0.6 24 +1-4 68 ± 2.5 (72) 94.8 +2-1.5 +2 112.8-1.5 135 +2.5-2 +0.6 55.5-1.1 52.5 ± 0.5 39.5 ± 0.4 (9) 20 min. +0.2 8.5 0 6 ± 0.2 EP.MERSEN.COM 8

Special purpose gpv fuse link size NH2 Plain Blade without trip indicator 68 ± 2,5 2,5 2,5 2,75 ± 0,1 26 +0,2 1 48,5 +0,3 1,3 60 ± 0,6 9,5 +1,5 0,5 (72) 6 ± 0,2 150 ± 2,5 51 ± 0,6 EP.MERSEN.COM 9

Special purpose gpv fuse link size NH2 Direct Mounting without trip indicator and without lugs +0.9 27-0.7 68 ± 2.5 (72) 99.8 +2.2-1.7 +2.2 117.8-1.7 150 +2.3-1.8 60 ± 0.6 63 +0.7-1.2 51 ± 0.6 6 ± 0.2 +0.2 10.5 0 +0.2 26-1 (14) EP.MERSEN.COM 10

NH fuse-base for NH fuse-links gpv, size 1, type PP, open design 199.5 +1.5 2.1 141.5 +1.5 2.1 57 6 230,5 302.5 +2.5 3.1 10 14 125.5 Ø 8.5 8.5 8.5 11 40 15 109 54 250.5 270.5 14 10 10 EP.MERSEN.COM 11

NH fuse-base for NH fuse-links gpv, size 2, type PP, open design 60 0 0.5 35 66 122.5 226 202 ± 1.5 25 ± 0.7 Ø 10 ± 0.5 Ø 20.5 250 82 +1 2 M 10 146 30 ± 0.7 126 +0.5 1 192 +1 2 89 35 ± 1.5 258 +1.5 3 For multi-pole applications: In case of installation of multi-pole units without phase barriers, a distance of 8 mm must be considered between the live (current carrying) parts of the fuses (single units). EP.MERSEN.COM 12

NH fuse-base for NH fuse-links gpv, size 1, type PP, with touch protection 87 ± 1 67.2 32 80 250 ± 1 35.6 18 6 146 ± 1 25 ± 0.3 30 ± 0.3 Ø 20.5 Ø 10.5 115 ± 1 10 25 81 137 176 ± 1 209 M 10 115 ± 0.5 122.5 ± 1 60 ± 1 35 2 25 NH fuse-base for NH fuse-links gpv, size 2, type PP, with touch protection 87 ± 1 67.2 250 ± 1 35.6 18 6 115 ± 0.5 122 ± 1 146 ± 1 25 ± 0.3 35 30 ± 0.3 60 ± 1 Ø 20.5 Ø 10.5 115 ± 1 2.5 35 10 25 89 81 25 M 10 145 201 ± 1 225 EP.MERSEN.COM 13

NH fuse-handle for NH fuse-links size 00 to 4 22 30 operating device to release link 26 ca.360 145 44 94 ca. 245 114 65 110 fireproof arm protection EP.MERSEN.COM 14