IPS1000 INSTALLATION & OPERATION MANUAL PURE-SINE INVERTER.

Similar documents
INSTALLATION & OPERATION MANUAL

IPS1000 Series Pure-Sine Inverter

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

INSTALLATION & OPERATION MANUAL

VTC1000 Series Voltage Converter. Installation & Operation Manual

VTC610 Series Voltage Converter. Installation & Operation Manual

Installation & Operation Manual PWS1000R Rack Mount Power Supply

DC to DC Step Up Converter Model: VTC305

INSTALLATION & OPERATION MANUAL VTC1505 SERIES VOLTAGE CONVERTER

INSTALLATION & OPERATION MANUAL VTC605 SERIES VOLTAGE CONVERTER

INSTALLATION & OPERATION MANUAL PWS1505 SERIES POWER SUPPLIES

BCD600 Series Battery Charger DC. Installation & Operation Manual

BCD610 DC Source Battery Charger

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

PURE SINE WAVE DC-AC INVERTERS

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Battery Back-up Model: BBM-1225

AUTOMATIC BATTERY CHARGER

ADI-125/750 ADI-125/1500 ADI-125/2500

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

DC to AC Power Inverters

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

DC to AC Power Inverters

MIL-24/2600Q MIL-24/3200DQ

OWNERS MANUAL JANUARY 2007 ISO

Power Distribution Units

RU BMS Power Supply and Battery Management System Owners Guide

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Power Distribution Units AP9560 & AP9561

WF-5110R True Sine Wave Inverter

DC-AC MODIFIED SINE-WAVE INVERTER OWNER S MANUAL SI-750HP MODEL: Please read this manual before operating your inverter.

OWNERS MANUAL JANUARY 2007 ISO

CLEAN POWER TM CPS Series Operator s Manual

SunCharger Portable Solar Panel Models: SC-05 SC-10. Owner's Manual. Please read this manual before operating the units

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

O W N E R ' S M A N U A L

WF-5110R True Sine Wave Inverter

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

PROwatt 150 DC to AC Power Inverter. Owner s Guide

LESTRONIC II BATTERY CHARGER MODEL 19740

installation kit Ask your retailer!

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Inverter User Manual

EN120 EN180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

A48 / A48B (base plate) BATTERY CHARGER

WF-5100 Series True Sine Wave Inverters

GSL Electronics Modified Sine Wave Power Inverters

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

Battery Power Inverters

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

WARNINGS, CAUTIONS AND NOTES

Item no Smart AC 200 USB. User s Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Power Inverter 400 MW Owner s Manual

powerdriveinverters.com Owner s Guide Please Save for Future Reference 100 Watt DC to AC Power Inverter

Toll Free DX100. Owner's Guide. Printed in China

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

powerdriveinverters.com Owner s Guide Please Save for Future Reference 150 Watt DC to AC Power Inverter

User s Manual. Automatic Switch-Mode Battery Charger

Owner s Guide. DC TO AC Power Inverter

Owner s Manual. PowerVerterDC-to-AC Inverter

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

The Power of Reliability INSTRUCTION MANUAL

DC TO AC POWER INVERTER

A32 (UPS) UNINTERRUPTIBLE POWER SYSTEM ECN/DATE CPN /06 INSTRUCTION DRAWING NUMBER: Page 1 of 11 INSTRUCTIONS FOR A32 - UPS

A39 UNIVERSAL SCR CHARGER

Operating Instructions

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Power Inverter. Owner s Manual

A63 DC/DC CONVERTER INSTRUCTION MANUAL ECN/DATE /05 INSTRUCTION DRAWING NUMBER: CPN INSTRUCTION MANUAL FOR A63 DC/DC CONVERTER

TOTAL POWER MODULE (TPM) HIGH FREQUENCY FLOAT CHARGER / BATTERY ELIMINATOR WITH UNIVERSAL INPUT USED WITH A TOTAL POWER CAGE (TPC)

ELECTRONIC MARINE CONVERTER/CHARGER Owners Manual Models PD2020, PD2030, PD2040, PD2050, PD2060, PD2080

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

BRAVO Inverter/Battery Charger. Table of Contents

powerdriveinverters.com Owner s Guide Please Save for Future Reference 300 Watt DC to AC Power Inverter

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

230VAC Power Inverter 400W Owner s Manual

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

DX100. Owner's Guide Conforms to UL Std Toll Free

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

ATD WATT INVERTER

Transcription:

INSTALLATION & OPERATION MANUAL IPS1000 PURE-SINE INVERTER An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com

Copyright (2005-2014) Analytic Systems Ware (1993) Ltd.

IMPORTANT & SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for inverter. 2. Do not expose inverter to rain or snow. 3. Use of an attachment not recommended or sold by the inverter manufacturer may result in a risk of fire, electric shock, or injury to persons. 4. Do not disassemble inverter; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. 5. To reduce risk of electric shock, unplug inverter from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. 6. Never place inverter directly above battery; gases from battery will corrode and damage marine inverter. 7. Never allow battery acid to drip on inverter when reading gravity or filling battery. GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS Inverters should be grounded to reduce risk of electric shock. Inverter is equipped with electric receptacles capable of accepting an equipment-grounding conductor and a grounding plug. Analytic Systems does not recommend the use of the IPS1000 Series Inverters in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as critical by the U.S. FDA. 3

Introduction Computers are moving into non-traditional work areas at an ever increasing rate as more and more specialty software packages become available. However there is a major problem. Computers require clean, pure AC power to work reliably. If you power one from the same Genset that runs your heavy loads, you could damage it from surges and spikes generated by switching those loads. If you power it from the same Inverter that runs a microwave and other electrical devices, similar problems occur, plus voltage dropouts from excessive loads on the inverter add to the problem. Also, most inverters produce Quasi-Sine Wave AC, which often doesn t run computers very well. Complaints of noisy displays, cursors that move by themselves and more abound. The IPS1000 Series 1000 Watt Pure Sine Wave Inverter is designed specifically for running computers and their related equipment. FEATURES Pure Sine Wave 115 VAC / 60 Hz or 220 VAC / 50 Hz fully regulated output, exactly the same as commercial AC. Crystal controlled for precise frequency (± 0.01 Hz). 1000 Watts output power sufficient for a complete computer workstation and more. State of the art MOSFET technology and unique Soft-Start circuitry for reliable operation. Illuminated ON-OFF switch for positive indication of proper operation. Heavy input filtering to shield other devices sharing the same battery. Transformer type output to protect computers and other sensitive equipment from surges and spikes. Low voltage warning and shutdown circuitry to protect the batteries. Over voltage and over temperature warning and shutdown circuitry to protect the inverter. Short circuit protection. LED indicators and a buzzer to bring attention to the cause of the shutdown. Two AC receptacles for easy connection of up to four devices. Versions are available for 12, 24, 32, 48 and 72 volt battery systems. Optional line detect feature available for operation as an off-line UPS. Three year parts and labour warranty. 4

Specifications Input Voltages Nominal (ip) 12Vdc 20Vdc 40Vdc Actual 10.5-16Vdc 20-40Vdc 40-80Vdc Input Amps (max) 179 94 47 Input Fuses (ATC) 40 Amp x 5 25 Amp x 4 25 Amp x 2 Output Voltages Nominal (op) 110Vac 220Vac Actual (VAC) 115 ± 5Vac 220 ± 10Vac Output Amps (cont) 8.7 4.5 Output Amps (max) 13.0 6.8 Output Frequency 60.00 ± 0.01 Hz 50.00 ± 0.01 Hz Output Type Pure Sine Wave Output Distortion < 5% at 1000 Watts into 0.8 power factor load General Efficiency > 80 % @ maximum output Temp. Range -25 to +40 deg. C @ maximum output Isolation Length Width Height Clearance Material Finish Fastenings Weight Input-Output & Output-Case 1500Vdc Input-Case 500VDC (1500Vdc for 40V input) 13.0 in / 33.0 cm 9.0 in / 22.9 cm 7.8 in / 19.8 cm 1 Inch (2.5 cm) all around Marine Grade Aluminum Black Powder Epoxy/Black Anodized 18-8 Stainless 30 lb / 13.6 kg * Specifications subjects to change without notice. Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 8128 River Way Delta, BC V4G 1K5 Canada p. 604.946.9981 f. 604.946.9983 tf. 800.668.3884 US/Canada www.analyticsystems.com analyticinfo@analyticsystems.com Revised September 2014 5

Installation MOUNTING Mount the unit in a DRY location. Mount the unit in a ventilated area. Allow at least 1 inch of clearance around the unit for adequate cooling. It is NOT recommended that the unit be secured until it has been tested under the intended load. CAUTION: The case of the inverter is connected to AC Ground and AC Neutral to meet regulatory requirements and to reduce the possibility of it generating any radio frequency interference. The case must be bonded appropriately to the grounding system of the vehicle or marine vessel. On a vehicle bond the case to the frame and on a marine vessel bond the case to the hull. A grounding stud is provided on the front of the inverter for this purpose. To ensure proper grounding, check the connection with an ohmmeter. CAUTION: Do not mount the unit where explosive gases may accumulate as a slight arc may occur when the power leads are connected, and in the unlikely event of a failure, sparks may be generated inside the unit. POWER CONNECTION Use a voltmeter to measure the input voltage to ensure the voltage of the battery is within the Input Voltage range printed on the front of the unit. The High-Voltage and Low-Voltage alarm set points are now infinitely adjustable between the minimum and maximum allowable input voltages for these inverters. The adjustment is made by using a small flat-blade screwdriver to turn the potentiometer which is accessible through the HI / LO VOLT ALARM SET opening on the front of the inverter. Setting the potentiometer fully counter-clockwise sets the low and high voltage alarms to their lowest settings. Turning the potentiometer fully clockwise sets the low and high voltage alarms to their highest settings. If the voltage alarm goes off during normal operation, first confirm that the battery voltage is within the normal range for your battery system. If it is, then adjust the alarm set points by turning the potentiometer slightly clockwise if the Low Battery alarm is on, or counter-clockwise if the High Battery alarm is on. The unit is supplied with two high current connectors that will accept up to AWG 1/0 cable to connect the input power. Use at least AWG 2 power cables, stripped but not tinned, and keep the length as short as possible. If the power cables are more than 6 feet (2 meters) long, increase the gauge to AWG 0. 6

Double-check that the battery is connected correctly: Positive to +, Negative to -. Before plugging any devices into the unit, turn it on. If the power switch is illuminated, the unit is working properly. CAUTION: Do Not Reverse Connect the Input Wires. This will cause serious Damage to the Inverter and will not be covered by Warranty. OUTPUT CONNECTIONS Two standard AC receptacles are provided for connection of up to four devices. Ensure that the total average load does not exceed the continuous current rating of the unit. CAUTION: Do not apply AC voltage to the outlets. Damage caused by this action will not be covered under warranty. A Line AC Detect and Autoswitch option is available for Off-Line UPS operation. Consult your local representative. An optional AC output cable modification is available for hardwiring to a load. Consult your local representative for information on the modification and to specify a cable length and termination. DISCONNECTION If you disconnect the unit to remove it for service or storage, turn the power switch on for at least one minute after it has been disconnected to discharge the storage capacitors. Operation Turn the switch on the front of the unit on to energize the outputs. The switch will glow to indicate the presence of AC power at the receptacles. LINE AC DETECT & AUTOSWITCH OPTION LINE DETECT CONNECTION Plug the optional LINE IN cable into a standard 110 VAC wall outlet. The inverter will operate in Standby as long as power is available from the wall to run the load. If there is a power failure, or the voltage falls below 98 VAC, the inverter will switch on within a few AC cycles and take over supplying power to the load. The inverter will wait ten seconds after the power is restored before returning to Standby. A separate battery charger is required for UPS operation. Plug the battery charger into the source of AC power, NOT the inverter. 7

Troubleshooting This unit provides LED indicators and a buzzer and to help diagnose any problems. The unit should sound the buzzer to alert you prior to shutting itself down. You should immediately check the indicators to determine the cause of the shutdown. STANDBY LOW VOLT OVER VOLT OVER TEMP LOW VOLT & OVER VOLT Indicates that the unit circuitry deemed it necessary to shut down. One of the causes listed below has reached a critical level, The optional line input is energized. Indicates that battery voltage is normal because:. The battery needs to be recharged, The battery voltage adjustment potentiometer on the inverter is set incorrectly, The battery voltage is not compatible with the inverter. Indicates that the battery voltage is above normal because:. The charging system may be faulty, The battery voltage adjustment potentiometer on the inverter is set incorrectly, The battery voltage is not compatible with the inverter. Indicates that the inverter is running too hot because:. Too much power is being drawn, turn off or unplug some devices. The inverter is located in a poorly ventilated area. Indicates that the inverter output is shorted or nearly shorted because: A short circuit exixts at the output, The inverter is severely overloaded. 8

TROUBLE SHOOTING CHECKLIST Use a voltmeter to measure the input voltage. The input should match the rating printed on the unit. Check that the battery voltage adjustment potentiometer on the front of the unit is set for the measured input voltage. Ensure that the battery is connected correctly: Red to Positive, Black to Negative. The large (+) and (-) markings on the case are more reliable than the colors of the cable. Check the specifications of the load to see what power it consumes and test it from a standard wall outlet. Unplug all devices connected to the unit and turn it on. Make a note of any LED s which stay on. DEFECTS OR DAMAGE If after checking all of the above, the problem persists, you may assume the unit is defective or damaged and it must be returned for repair Remote Control Option A remote control panel may be connected to the inverter using a 9-pin D-connector, which attaches to the front panel of the inverter. The remote control panel and D connector are part of the remote control option. The remote control panel allows the unit to be operated remotely as well as duplicating all the diagnostic indicators and audible alarm. IMPORTANT: This remote is to be used only on Inverters manufactured by Analytic Systems. REMOTE CONNECTOR This connector is located on the front of the unit. Important: To prevent the possibility of High Voltage Electrical Shock, do not power up the Inverter unless all wiring from the unit to the remote is securely connected. Do not remove the dust cover from the DB-9 connector if the remote is not being used. 9

Special Services & Options Conformal Coating INCLUDED ON ALL UNITS UNLESS REQUESTED NOT TO as of April 1, 2014 Option c Option v Option MS Option w Option SM Option d Option FI Option F Special Input Special Output Water tight options Ruggedization Package (EXTRA Conformal Coating and RTV Compound) Marine / Industrial Pkg (EXTRA Conformal dipping and RTV Compound) Military Pkg (incl. Wide Temp Components, Conformal Dipping and RTV Compound) Wide Temperature Operation (-40 to +55 C, incl) High Voltage Protection on the DC Input Side Paralleling Diodes Forklift Modifi cations Open Frame - No chassis just heat sink bars (not for all products) There is no charge for nominal output voltages (ie. 12.0, 24.0, 48.0), but th must be noted at the time of order (Contact Factory for details) IP66, IPS67, IPS68 10

Limited Warranty 1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the Warrantor ) is warranted to be free from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or a. The date of shipment by Analytic Systems, or b. The date of manufacture coded in the serial number, or c. From a copy of the original purchase receipt showing the date of purchase by the user. 4. In case any part of the equipment proves to be defective, the Purchaser should do the following: a. Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and include the date of purchase, the place of purchase, and the Purchasers name, address and telephone number. b. Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization number (RMA). c. Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada. 5. If upon the Warrantor s examination the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor s option without charge, and returned to the Purchaser at the Warrantor s expense by the most economical means. Requests for a different method of return or special handling will incur additional charges and are the responsibility of the Purchaser. 6. Analytic Systems reserves the right to void the warranty if: a. Labels, identification marks or serial numbers are removed or altered in any way. b. Our invoice is unpaid. c. The defect is the result of misuse, neglect, improper installation, environmental conditions, non-authorized repair, alteration or accident. 7. No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. 8. Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall render this warranty void. 9. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for equipment specifically stated to be waterproof. 10. No other express warranty is hereby given and there are no warranties that extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. 11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. 12. The Warrantor assumes no liability for incidental or consequential damages of any kind 11

An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com