HD110C Heavy-Duty Digital Multimeter

Similar documents
Autoranging Industrial Multimeter

True RMS Autoranging Multimeter

Autoranging Multimeter

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

DIGITAL MULTIMETER INSTRUCTION MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Digital Insulation Resistance Testers. you can depend on

Digital/Analog Megohmmeter Model 1026

ATD-5570 DELUXE AUTOMOTIVE METER

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Dawson DDM190D. Digital Multimeter User s Manual

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User's Guide. True RMS Multim eter. Extech 430

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

User Guide. Model Insulation Tester / Megohmmeter

COMPONENT-TESTER INSTRUCTION MANUAL

User Guide. Model Insulation Tester / Megohmmeter

323/324/325 Clamp Meter

KMP Insulation-Continuity Tester. Users Manual

USER MANUAL. Insulation Tester + DMM. Model MG320

New! Fluke 922 Airflow Meter. Fluke HVAC/IAQ Tools. Get more done.

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

707Ex. Users Manual. ma Calibrator

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

365 Detachable Jaw True-rms Clamp Meter

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

Model Insulation Tester / Megohmmeter. User Manual

Users Manual. MegOhmMeter

OPERATING INSTRUCTION

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

User Guide. Model Insulation Tester / Megohmmeter. Introduction

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

373 Clamp Meter. Users Manual

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Temperature Calibrator

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

233 True-rms Remote Display Digital Multimeter Safety Information

Go to to register your product and find more information.


1587/1577. Calibration Manual. Insulation Multimeters

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Visit us at

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

ELECTRICAL TESTING WORKSHOP Circuit Tester 6, 12, 24 Volt

5.2 PRE-OPERATION PROCEDURE WARRANTY

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Table of Contents Title Page No.

80 Series V Digital Multimeter Safety Information

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

i3000s/i2000 Flex AC Current Probe

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

OUTPUT VOLTAGE 5V MAX.INPUT CURRENT 16.0A 12V 7.0A 12V 12V 24V 35.0A 28V 48V 12V 15V 24V 28V 23.0A 48V 12V 15V 24V 28V 48V 11.5A

712 RTD Calibrator. Instruction Sheet. Introduction

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Model UT601: OPERATING MANUAL

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

Model 125 Electrical Service Voltmeter

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

(typ.) (Range) ±18 330# 89 MPW MPW

MIT515, MIT525, MIT1025, MIT1525

(typ.) (Range) Load

OPERATING INSTRUCTIONS

Volt/mA Calibrator. Manual

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

PROVA 1011 Solar System Analyzer

WENS30C Loop Calibrator

Digital Multimeter AHMAD FOUAD ALWAN

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

S1-568, S1-1068, S1-1568

302+/303 Clamp Meter. Users Manual

C B. Operating up to 5000m altitude 5 year product warranty Models

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

MIT300 Series Insulation and Continuity Testers

THWD-3 and TH-3 Relative Humidity and Temperature Meters

i400s Calibration Information Introduction

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Users Manual. Phase Rotation Indicator

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Load (2) Single or Dual

Industrial Power Supplies

USER'S MANUAL. Standard-version BM810 & BM510 Series. X-version BM810X & BM510X Series. CF-version BM810CF & BM510CF Series

SuperEvac LCD Vacuum Gauge Full Range. Digital LCD Vacuum Gauge. Digital Vacuum Gauge

Transcription:

HD110C Heavy-Duty Digital Multimeter Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Magne-Grip holster with magnetic hanging strap No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive No Hassle warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. Highest voltage capability, measuring to 1500 V dc and 1000 V ac CAT IV 1000 V rated Special sealing for environment and water resistance. IP67 rated Constructed with drop-resistant housing and PCB mounting Magne-Grip holster, frees both hands for work Includes high voltage test leads with threaded alligator clips The HD110C is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. HD110C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kv. HD110C N10140

HD110C Technical Specifications General Specifications Display Polarity Indication Input overload indication 1 Low Battery Indication Display Update Rate Oper. Temp. Storage Temp Temperature coefficient Altitude Fuse Power Auto Power-Down Battery Life 3-1/2 digit LCD, 1999 counts, with annunciators and menu features Automatic B; < 50 hours battery life remain, accuracy is no longer guaranteed 2.5/sec, nominal 0 C to +50 C, (< 75 % R.H.) -20 C to 60 C, 0 to 80 % RH, battery removed 0.1 x (spec. accuracy)/ C (0 to 18 C and 28 to 50 C) all functions and ranges except for mvdc 0.3 x (spec. accuracy)/ C (0 to 18 C and 28 to 50 C) for mvdc Up to 2000 m indoor use F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 ka Amprobe p/n FP700 Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F22 Meter powers down after approx. 30 min. of inactivity. 250 hours typical with carbon-zinc, 500 hours typical with alkaline Dimensions, with holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) Accessories Case material Safety 642 g (20 oz) EMC Meets EN 61326-1 Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex wrench in holster, Magne-Grip flex strap and User Manual Flame retardant, high-impact thermoplastic Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 Electrical Specifications (Accuracies at 23 C ± 5 C, <75 % RH non-condensing, guaranteed for one year.) DC Volts 200 mv, 2 V, 20 V, 200 V, 1500 V 0.1 mv Accuracy All ranges ±(0.1 % rdg+2 dgts) Input Impedance Transient Protection AC Volts (45 Hz to 2 khz) 10 MΩ 1500 V dc/1000 V ac rms 12 kv impulse (1.2 µs/50 µs) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kv. 200 mv, 2 V, 20 V, 200 V, 1000 V 0.1 mv Accuracy 200 mv to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts) 200 mv to 200 V (500 Hz-2 khz) ±(1.5 % rdg+5 dgts) 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) Input Impedance Transient Protection DC Current 10 MΩ 0.1 µa 1500 V dc/1000 V ac rms 12 kv impulse (1.2 µs/50 µs) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kv. 200 µa, 2 ma, 20 ma, 200 ma, 2 A Accuracy 200 µa to 20 ma ±(0.5 % rdg+2 dgts) 200 ma to 2 A ±(1.0 % rdg+2 dgts)

HD110C Technical Specifications (continued) DC Current (cont.) Voltage Burden 250 mv max. (1 mv/1 µa on 200 µa Range) (100 mv/1 ma on 2 ma Range) (10 mv/1 ma on 20 ma Range) (1.5 mv/1 ma on 200 ma Range) (500 mv/1 A on 2 A Range) A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700) AC Current (45 Hz to 1 khz) 0.1 µa 200 µa, 2 ma, 20 ma, 200 ma, 2 A Accuracy 200 µa to 20 ma ±(0.8 % rdg+4 dgts) 200 ma to 2 A ±(1.2 % rdg+4 dgts) Voltage Burden Resistance 250 mv max. (1 V on 2 A range) same as DC Current 200 Ω, 2 kω, 20 kω, 200 kω, 2 MΩ, 20 MΩ 0.1 Ω Accuracy 200 Ω ±(0.5 % rdg+4 dgts) 2 kω to 200 kω ±(0.3 %rdg+2 dgts) 2 MΩ ±(1.0 % rdg+4 dgts) 20 MΩ ±(2.0 %rdg+4 dgts 1500 V dc/1000 V ac rms Open Circuit Voltage 200 Ω range 3.0 V dc typical all other ranges 0.3 V dc typical. Diode/Continuity Test Test Current Test/Open Circuit Voltage Diode Accuracy Continuity Audible Threshold Response Time 1m A dc typical 3.0 V dc Typical ±(1.5 % rdg+2 dgts) <50 Ω ± 25 Ω <100 msec 1500 V dc/1000 V ac rms

Included Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (in instrument), hex wrench in holster, Magne-Grip flex strap and User Manual Optional Accessories TL1500 Cat IV 1000 V Test Leads with Alligator Clips CT235A 1000 A ac/dc Clamp CT237A 200 A ac/dc Current Clamp CT238A 20 A ac/dc Current Clamp VC221B Padded Vinyl Case. Fits meter & holster. DC205C Deluxe Hard-Shell Carry Case DC207C Large Deluxe Hard-Shell Carry Case with extra space for accessories HV231-10A High Voltage Probe FP700 Replacement Fuse, 2 A/1500 V, pack of two website: email: info@amprobe.com 6920 Seaway Blvd. Everett, WA 98203 tel: 877-AMPROBE Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands 2007 Amprobe Test Tools. All rights reserved. 3/2007 PN: 1646323 Rev C

HD160C Heavy-Duty Digital Multimeter Rugged autoranging meter with true-rms Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Temperature, Frequency & Capacitance Magne-Grip holster with magnetic hanging strap No hassle warranty No waiting. Highest voltage capability, measuring to 1500 Vdc and 1000 Vac CAT IV 1000 V rated Special sealing for environment and water resistance. IP67 rated Constructed with drop-resistant housing and PCB mounting Measures capacitance, temperature and frequency Superior 10,000 count resolution with bar graph Magne-Grip holster, frees both hands for work Includes high voltage test leads with threaded alligator clips Temperature measurement built-in Frequency and capacitance Digi-Glo bright backlight No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive No Hassle warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. The HD160C is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistance to at least eight feet. Model HD160C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kv. HD160C N10140

HD160C Technical Specifications General Specifications Display Polarity Indication Input overload indication Low Battery Indication Display Update Rate Oper. Temp. Storage Temp. Altitude Temperature coefficient Fuse Power Auto Power-Down Battery Life (typical) 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Automatic OL, -OL. B; less than 50 hours battery life remain, accuracy is no longer guaranteed 2/sec, nominal; 20/sec for bargraph. 0 C to +50 C @ 0 to 75 % R.H. -20 C to 60 C @ 0 to 80 % RH, battery removed 2000 meters - indoor use 0.1 x (spec. accuracy)/ C (0 C to 18 C and 28 C to 50 C) F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 ka Amprobe p/n FP700 Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function. 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly. Backlight auto-off after approx. 60 seconds. Dimensions, without holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) Accessories Case material Safety 642 g (22 oz) EMC Meets EN 61326-1 Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA 1A) and User Manual. Reinforced, high-impact, fire retardant thermoplastic Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 Electrical Specifications (Accuracy at 23 C ± 5 C, <75 % RH, guaranteed for one year.) DC Volts Accuracy Input Impedance CMRR NMRR 1000 mv, 10 V, 100 V, 1500 V 0.1 mv in 1000 mv range ±(0.1 % rdg + 5 dgt) 10 MΩ >120 db up to 1500 V dc >60 db at 50 or 60 Hz. Transient protection 12 kv impulse (1.2 µs/50 µs) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations where transients exceed 12 kv. AC Volts True rms 1000 mv, 10 V, 100 V, 1000 V 0.1 mv in 1000 mv range Accuracy 1000 mv (45 Hz to 400 Hz) ± (1.2 % rdg + 10 dgt) 10 V, 100 V (45 Hz to 500 Hz) ± (1.2 % rdg + 10 dgt) 10 V, 100 V (500 Hz to 2 khz) ± (2.0 % rdg + 10 dgt) 1000 V (45 Hz to 1 khz) ± (2.0 % rdg + 10 dgt) Input Impedance Conversion type Crest factor 3 Transient protection 10 MΩ True rms, ac coupled 5 % to 100 % of range 12 kv impulse (1.2 µs/50 µs) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kv

HD160C Technical Specifications (continued) DC Current 100 µa, 1000 µa, 10mA, 100mA, 400mA, 2A (Auto/Manual ranging) 0.01µA in 100 µa range Accuracy 100 µa range ± (0.5% rdg + 10 dgts) 1000 µa to 400 ma ranges ± (0.5% rdg + 5 dgts) 2 A range ± (1.5% rdg + 10 dgts) Input protection Burden voltage AC Current True rms 2 A/1500 V fast blow ceramic fuse 8 65 mm on A input, FP700 µa range of 1 mv/1 µa, ma range of 10 mv/1 ma, 2A range of 500 mv/1a, 500 mv max. (2 V max. on 1000 µa, 100 ma, 400 ma, 2 A ranges) A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) 100 µa, 1000 µa, 10 ma, 100 ma, 400 ma, 2 A 0.01 µa in 100 µa range Accuracy (45 Hz to 1kHz) 100 µa to 100 ma ± (1.5 % + 10 dgts) 400 ma ± (2.0 % + 10 dgts) 2 A ± (2.5 % + 20 dgts) Voltage burden Conversion type Crest factor 3 OL protection Resistance see DC Current True rms ac coupled 10 to 100% of range see DC Current 1000 Ω, 10 kω, 100 kω, 1000 kω, 10 MΩ, 40 MΩ 0.1 Ω in 1000 Ω range Accuracy 1000 Ω to 1000 kω ranges ± (0.5 % rdg + 8 dgts) 10 MΩ range ± (1.0 % rdg + 10 dgts) 40 MΩ range ± (2.0 % rdg + 10 dgts) Overload protection, all ranges Continuity Test Audible indication Response time Overload protection Capacitance Less than 40 Ω 100 ms 40 ηf, 400 ηf, 4 µf, 40 µf, 400 µf (3999 counts) (Auto/Manual ranging) 0.01 ηf Accuracy 40 ηf, 400 µf ranges ±(3.0% rdg +10 dgts) 400 ηf to 40 µf ranges ±(3.0% rdg +5 dgts) Test voltage Test Frequency Overload protection < 1 V 1.3 Hz on 40 ηf to 40 µf ranges; 0.7 Hz on 400 µf range Temperature -20 C ~ 1300 C (-4 F ~ 2372 F) 3999 counts 1 C, 1 F Accuracy -20 C ~ 10 C ±(2.0% rdg + 4 C) 10 C ~ 200 C ±(1.0% rdg + 3 C) 200 C ~ 1300 C ±(2.0% rdg + 2 C) -4 F ~ 50 F ±(2.0% rdg + 8 F) 50 F ~ 400 F ±(1.0% rdg + 6 F) 400 F ~2372 F ±(2.0% rdg + 4 F) Overload protection (continued on next page)

HD160C Technical Specifications (continued) Frequency Accuracy 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz 0.01 Hz on 100 Hz range ±(0.1% rdg + 5 dgts) Sensitivity 3 Hz to 1 MHz >2.5 V ac rms 1MHz to 10MHz >2.5 V ac rms, <5 V ac rms Minimum input range 100 Hz range >3 Hz; 1000 Hz range >30 Hz Minimum pulse width > 25 ns Duty cycle limits > 30 % and < 70 % Overload protection Included Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA 1A) and User Manual. Optional Accessories TL1500 Cat IV 1000 V Test Leads with Alligator Clips CT235A 1000 A ac/dc Clamp CT237A 200 A ac/dc Current Clamp CT238A 20 A ac/dc Current Clamp VC221B Padded Vinyl Case. Fits meter & holster. DC205C Deluxe Hard-Shell Carry Case DC207C Large Deluxe Hard-Shell Carry Case with extra space for accessories HV231-10A High Voltage Probe FP700 Replacement Fuse, 2 A/1500 V, pack of two TA-1A K-type thermocouple, temperature adapter website: email: info@amprobe.com 6920 Seaway Blvd. Everett, WA 98203 tel: 877-AMPROBE Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands 2007 Amprobe Test Tools. All rights reserved. 3/2007 PN: 1646298 Rev C