HM SERIES. (Outdated connector) Features P-01

Similar documents
DL SERIES N-01. Features

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

CHEMICAL MIXING SYSTEM OPERATING AND INSTALLATION INSTRUCTIONS

Pantera Electronics Rocker Switch Installation Manual

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

Advanced Instructions

XK8 / XKR Navigation to Triple Gauge Cluster Conversion Harness Kit. Instructions

Installation Manual v1.0: Code Blocker Electronics Kit GM LBZ Duramax. Please read all instructions before installation.

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

ANR SPECIFICATIONS. MATERIALS RoHS COMPLIANT - E222871

Spreader and Vehicle Battery Kits

INSTALLATION & OWNER S MANUAL

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mazda For Models With Manual Climate Controls TOOLS REQUIRED:

INCREASED SAFETY ALUMINUM CORD CONNECTORS

TL INSTALLATION MANUAL FOR TELMA AF50-90 with ROTARY FOOT SWITCH DESIGN 2 FORD F550 CAB CHASSIS FROM MODEL YEAR 2011

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

Page 1 of 7 PETBAMBI PETASPOESTERTJIE

INSTALLATION INSTRUCTIONS FOR PART

INSTRUCTIONS. 20 Circuit Wiring Kit Instructions October 2009, Speedway Motors, Inc.

AXIAL LEADED COATED INDUCTORS

Repair harness. Repair Harnesses

Industrial Electrical Solutions

Power Inductor DIP Type

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.

Western Products, PO Box , Milwaukee, WI Hopper Spreader. Control Wiring and Electrical Components

Installation Tips for your Excalibur Remote Start (for Honda and Acura Vehicles) rev 11/28/2012

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

CMC Hybrid Connectors Standard and Power Versions

Installation Items: Cruise Module

BOM507-BC Black Out Module 2017 Ford F250-F550 Contact InterMotive for additional applications

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mazda TOOLS REQUIRED:

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mercedes C-Class Mercedes CLK 2004 TOOLS REQUIRED:

TIP SHEET T0491. Installation Tips for your Excalibur RS Passlock-sl2(4) + DLRC + SPDT

Mobile Cylinder Div. Standard Build Series. Catalog HY /US Rev C

FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K A-600

Weistec M177 WMI System

Installation Instructions for Swing Mount System

Insulated Crimp Terminals

Vehicle Security System

023_quick splice_vinyl. Terminals & Cable Ties

DATA & DISPLAY RETENTION INTERFACE

INSTALLATION INSTRUCTIONS

Amphenol Air LB. Contacts & Outillages. Contacts & Tooling

Quick Reference for International CF Series Electrical Circuit Diagrams

General Purpose IEC Fuses

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Ford Explorer Explorer Sport Trac Ranger

Classic Update Series

12 Point Flange Screws

MSD SB6 Programmable Ignition for the Kawasaki ZX-14 PN 4219

BMW S1000RR Z-Fi QS / Z-Fi TC Installation Instructions P/N S541S, S541R, T541S, T541R

IMPORTANT ATTENTION INSTALLERS:

INTERFACE PART NUMBER NOTES

Installation Guide. CellSet MC/GPS-Harley. Kennedy Technology Group, Inc.

RS SERIES. Features. RS シリーズは ターミナルサイズが2.3mm で構成されており 各種の制御回路並びに低パワー回路に対応することができます RS 標準タイプコネクタは コネクタの半嵌合が起きにくい慣性ロック方式です ( 慣性ロック方式でないコネクタが一部あります )

Specif ications. S&C Positrol Fuse Links. Outdoor Distribution

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

If you find any errors or omissions, or if you can offer improvements to this guide, please contact Dave Barton,

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

MSD 7AL-3, Ignition Control PN 7230

VALCON HARDWARE MANUAL

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Rear Vision System Tailgate Emblem Camera Aftermarket Display 2009-Current Ford F-150 and 2010-Current Super Duty (Kit part number )

2004 Scion xa. PARKING LIGHTS (+) GREEN At Harness On Top Of Fuse Box DOOR TRIGGER (-) RED/WHITE In 9-Pin On Top Of Fuse Box

INSTALLATION INSTRUCTIONS

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

CHEVORLET IMPALA

Application Note TADII - Threshold Angle Detector Operation and Calibration Instructions

INSTALLATION INSTRUCTIONS FOR PART

Optional Wiring. This section deals with some of the optional wiring that may be needed depending on how you choose to construct your car.

Condition. Correction

INSTALLATION INSTRUCTION

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

8436, 8437, 8438, 8439, 8442, 27480, 27780, 28028, & ISOLATION MODULE ELECTRICAL SYSTEM

Mustang One-Touch Convertible Top Module (2005+) - Installation Instructions

ADDICTIVE DESERT DESIGNS

BE 1 BODY ELECTRICAL SYSTEM

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS Lexus ES Series

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. KIA Sedona KIA Spectra (2004 Base and LS models only) F TOOLS REQUIRED:

SmartX MF and MS

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS Toyota Tacoma

EH CONNECTOR. 1Certified LR R Disconnectable Crimp style connectors. Features. Specifications. Standards. 2.5mm

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

FrelTec GmbH. Wire Wound Ceramic Chip Inductors SMD

TL INSTALLATION MANUAL FOR TELMA AF50-55 ON FORD E-350/450 CUTAWAY with rotary foot switch design 2 including MY2016 changes

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS VW Touareg/Touareg

MSD Programmable Shift Controller PN 75591

TRADING CO., INC. AUTOMOTIVE ELECTRICAL SUPPLIES. We carry a full line of electrical supplies and primary wire! Call today!!

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Toyota. Sequoia Tundra

Turn Signal / Horn Kit PN 7101 by All years Polaris RZR 1000 and RZR 900, 900-4, 900 trail, 900S and 900XC STOP - THIS KIT IS DESIGNED

INSTRUCTION PLASTIC BATTERY BOX & CHARGER KIT

MultiFunction Module (MFM) Installation Instructions

PCS { ~

TL INSTALLATION MANUAL FOR TELMA AF50-55 ON CHEVROLET G4500 CUTAWAY 6.0L GASOLINE and 6.6L DIESEL ENGINE

Air Conditioner for M915 A0/A1 Truck

Transcription:

(Outdated connector) P-01 Features The HM connector series has a 4 mm pitch between terminal poles. This series consists of a 2.3mm type (2.3mm and 6.6mm types for the hybrid model) classifi ed according to terminal size, supporting use in a variety of control circuits and low power circuits. A joint model allows you to integrate multiple connectors, regardless of the number of ways. A splice connector is also available. In case of purchasing the subject parts, please contact our sales offi ce. Some part may not be in production.

Structure Connector M Connector F Housing M Housing F Terminal M Terminal F Terminal (mm) P-02 0.2 0.3 0.2 0.3 1.4 1.9 1.4 1.9 7 0.3 Sn 2.3 2 26.7 Sn 0.25 2.5 3 17.2 090 M(8230-4272) 0.5 1.25 F(8240-44) 0.5 1.25 1.6 2.9 1.6 2.9 7 0.3 Sn 2.3 2 26.7 Sn 0.25 2.5 3 17.2 M(8230-4282) F(8240-4422)

Housing (mm) 66Nylon Natural P-02 P-02 9.8 11.9 P-02 M(6090-1031) With clamp for 7mm dia. 7 2way 9.8 11.9 7 9.1 Plate thickness range for clamp t 0.7 2.2 M(6090-16) P-02 Flanged 9.8 11.9 P-02 F(6181-1001) P-02 F(6090-1001) P-03 9.8 7 3way 15.9 13.1 M(6090-1131) F(6090-1136) P-02 P-02 11.9 4way P-02 M(6090-1041) With clamp for 7mm dia. 7 9.1 11.9 Plate thickness range for clamp t 0.7 2.2 M(6090-13) Plate thickness range for clamp= F(6090-1011)

Housing (mm) 66Nylon Natural P-02 5way Secondary Locking Type 7.2 21 21 F(6090-56) P-02 P-02 15.9 6way P-02 M(6090-1149) With clamp for 7mm dia. 7 13.1 15.9 P-04 Plate thickness range for clamp t 0.7 2.2 P-02 M(6090-14) P-02 F(6090-18) 19.9 M(6090-1051) P-02 8way With clamp for 7mm dia. 7 19.9 17.1 Plate thickness range for clamp t 0.7 2.2 M(6090-15) P-02 Flanged 19.9 Plate thickness range for clamp= M(6090-12) F(6090-1021)

P-02 P-02 23.9 10way P-02 M(6090-1056) With clamp for 7mm dia. 7 21.1 23.9 Plate thickness range for clamp t 0.7 2.2 M(6090-17) P-02 F(6090-20) 7 10way 49.1 Plate thickness range for clamp= F(6090-54) P-05

Terminal (mm) Ref : 090 Terminal List (Page P-02) 090P-02 0.3 0.3 1.4 1.9 1.4 1.9 0.4 AntP-Corrosion treatment 6 24.3 0.32 AntP-Corrosion treatment 2.9 7.5 19.2 M(8230-4050) F(8240-4220) 0.5 2.0 0.5 2.0 1.6 3.4 1.6 3.4 0.4 AntP-Corrosion treatment 6 24.3 0.32 AntP-Corrosion treatment 2.9 7.5 19.2 M(8230-4040) F(8240-4140) 2.0 3.0 2.0 3.0 2.9 4.1 2.9 4.1 0.4 AntP-Corrosion treatment 6 24.3 0.32 AntP-Corrosion treatment 2.9 7.5 19.2 P-06 250 0.3 M(8230-4060) 0.3 F(1500-0081) 1.4 1.9 1.4 1.9 0.4 Sn 6 24.3 Sn 0.32 2.9 7.5 19.2 M(8230-4052) F(8240-4202) 0.5 2.0 0.5 2.0 1.6 3.4 1.6 3.4 0.4 Sn 6 24.3 Sn 0.32 2.9 7.5 19.2 M(8230-4042) F(8240-4182) 2.0 3.0 2.0 3.0 2.9 4.1 2.9 4.1 0.4 Sn 6 24.3 Sn 0.32 2.9 7.5 19.2 M(8230-4062) F(8240-4538) AntP-Corrosion treatment=

Housing (mm) 66Nylon Natural No. of way ( ) corresponds to 090, 250, in order from left to right. 090 250 6way 4 2 14.1 26.4 34.4 With clamp for 7mm dia. 7 10 23.8 23 M(6090-50) Plate thickness range for clamp t 0.7 2.2 The corners are rounded. 10 8mm F(6090-51) 8way 6 2 28.9 36.9 26.1 M(6090-31) F(6090-24) 10way 6 4 35.1 F(6090-30) P-07 14way 2 42.1 36.9 39.3 M(6090-1119) F(6090-19) Flanged 19way 18 1 29.9 22.4 38.4 27.3 20.6 23.5 M(6090-1182) F(6090-1183) 23way 22 1 63.7 36.9 60.9 Plate thickness range for clamp= M(6090-10) F(6090-1117)

Housing (mm) 66Nylon Natural No. of way ( ) corresponds to 090, 250, in order from left to right. 090 250 24way 22 2 67.7 36.9 64.9 M(6090-11) F(6090-1118) P-08

The rationalization and reliability are appreciably improved, by concentrating the splices in the wiring harness at one position. Splice connector 66Nylon Black P-02 Black Type 1 M(6409-0071) F(6400-00) Green P-02 Green Type 2 Gray M(6409-0072) P-02 Gray F(6400-0013) P-09 Type 3 M(6409-0255) F(6400-0081) Blue P-02 Blue Type 4 M(6409-0073) F(6400-0014) Natural P-02 Natural Type 5 M(6409-0076) F(6400-0010)

Orange P-02 Orange Type 6 M(6409-0075) F(6400-0016) Red P-02 Red Type 7 M(6409-0070) F(6400-0011) Yellow P-02 Yellow Type 8 P-10 Pink M(6409-0074) P-02 Pink F(6400-0015) Type 9 M(6440-08) F(6440-09) Brown P-02 Brown Type 10 M(6409-0603) F(6400-0186) Wisteria Violet P-02 Wisteria Violet Type 11 M(6440-0135) F(6440-0136)

The connectors which have different number of ways as well as the same number of ways can be connected each other. It is also possible to connect with the block type ET connectors. Clamping a single connector on a device, etc. where only a narrow clamping location is available makes it possible to clamp a multiple number of connector. Housing (mm) 66Nylon Natural P-02 P-02 13way 31.9 29.1 P-02 M(6090-1090) P-02 F(6090-1061) 14way 35.9 33.1 P-02 M(6090-21) P-02 F(6090-1064) P-11 16way 39.9 37.1 P-02 M(6090-1099) P-02 F(6090-1071) 18way 43.9 41.1 M(6090-1101) F(6090-1073) P-02 P-02 20way 47.9 45.1 M(6090-1107) F(6090-1081)

Housing (mm) 66Nylon Natural P-02 P-02 22way 51.9 49.1 M(6090-11) F(6090-1086) P-02 P-02 24way 55.9 53.1 M(6090-1113) F(6090-1087) P- Shape of Mating Support (mm) 090 Blocking type M housing can be mounted by providing the support as indicated above to the mating parts. 090 2 3 19.2 13.5 7 3 2.3 2 10 28 2 ) The dimensions as shown here are reference dimensions and detail dimensions for mounting portion of the mating support are specifi ed in the offi cial drawing. Please contact our sales staff.

Dimensions of Installation Panel (mm) Housings mentioned above can be mounted by machining the panel as indicated in the fi gure. Standard type 2way M housing (6181-1001) 8way M housing (6090-12) Hybrid type 19way M housing (6090-1182) 36 R3.5 max. 26 4.5 P-13