MS-Series. Circuit Breaker

Similar documents
F-Series. Circuit Breaker

F-Series. Circuit Breaker

PB-Series. GFCI/ELCI & Panel Seal

G-Series. Circuit Breaker.

PD-Series Ground Fault Circuit Protection

CX-Series. Circuit Breaker

L-Series. Circuit Breaker

G-Series DIN-RAIL CIRCUIT BREAKER

J-Series CIRCUIT BREAKER

Carling Circuit Breakers

Renewable Energy. Circuit Breakers and Disconnects

ID ID. Series 19. Mechanical Products Company

PDR circuit breaker - Ground fault Datasheet

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

FR circuit breaker - hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic,

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

ER circuit breaker - Hydraulic magnetic,

H-Series. Circuit Breaker.

Products :: Circuit Protection :: Thermal Circuit Breakers

F-Series General Specifications

Thermal-Magnetic Circuit Breaker 201/-WA

MINIATURE POSITIVE ACTION SWITCHES MIL-S-8834 Miniature Positive Action Switches Solder Lug Terminals

DIM. A (+ 0,05 0,51) .437 ±.020 (11,10 ± 0,51) DIM. F ±.015 (0,38) INTEGRAL ASSEMBLY NUT, DO NOT REMOVE

13000 series Professional quick-break momentary pushbutton switches

Magnetic and Hydraulic-Magnetic Circuit Breaker

209 Series. Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors

Momentary or alternate action pushbutton switches. UL approved 3A 250VAC, 6A 125VAC. Availability : consult factory for details of approved models.

Magnetic Overcurrent Circuit Breaker

Catalog Issued 3-03 (PDF Rev )

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Electronic Circuit Breaker ESS20-0..

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Selection Guide. Control Circuit and Load Protection

High Performance Thermal-Magnetic Circuit Breakers 410/520/

Circuit Breakers Circuit breakers are

5000 SERIES TOGGLE SWITCHES Distinctive features B

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Series L9 UL489 Miniature Circuit Breakers

8000 series Momentary or alternate action pushbutton switches

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MS General Information Extended Product Type: MS

High Performance Thermal Circuit Breaker

8000 series. Momentary or alternate action pushbutton switches DISTINCTIVE FEATURES ELECTRICAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS

CR circuit breaker - hydraulic magnetic,

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Product Highlights: Typical Applications:

Series L9 UL-489 Miniature Circuit Breakers

SolidMatrix 1206 Fast Acting Surface Mount Fuses

CC06H High I 2 t Chip 0603 size fuses

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Typical Applications: Product Highlights:

Rotary Potentiometer. 1/2 Watt, Composition. Electrocomponents. Industrial 24mm Diameter. Rotary Potentiometer. Features

Distinctive Characteristics

DATA-CON-X : SEALED USB TYPE A & B CONNECTORS

2SS/2S1/2SM SUB-MINIATURE TOGGLES

1.2. Pushbuttons and Indicating Lights. Contents Description Environmentally Sealed Toggle Switches E10E Product Selection

DD Frame - Series Circuit Breakers

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors

RBR circuit breaker - Remote operated

Thermal-magnetic Miniature Circuit Breaker 4230-T...

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

onlinecomponents.com

Miniature Circuit Breakers

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, 10 AMPERES AND LOW LEVEL, UNSEALED

Two case lengths. Three electrical functions. Sealing options. Model X1146 with Ø 16 (.630) bushing ELECTRICAL SPECIFICATIONS.

Momentary pushbutton switches - round plunger

Magnetic and Hydraulic-Magnetic Circuit Breaker

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Circuit Breakers Series AM/S

Fuseholders PAGE. Fuseholders.

SPECIFICATIONS, PACKAGING INFORMATION, AGENCY APPROVALS AND PART NUMBERING SYSTEMS FOR TABLE F2 FUSES

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

7000 Series Miniature Toggle Switches

Magnetic and Hydraulic-Magnetic Circuit Breaker

T Series Subminiature Toggle Switches

E Series Sealed Miniature Toggle Switches

PERFORMANCE SPECIFICATION SHEET ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY. (BETWEEN SERIES BNC TO SERIES TNC), CLASS 2, STRAIGHT PLUG

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

C&K E Series Sealed Miniature Toggle Switches

Thermal-magnetic Miniature Circuit Breaker 4230-T...

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

305/315/355 SERIES CARD EDGE CONNECTOR.156" (3.96mm) Contact Spacing

Engineering Product Specification C310T-SC Series Ceramic tube, Time delay

Control Circuit Protection

Thermal-Magnetic Circuit Breaker M1-...

S505SCH 5 x 20 mm Time-delay, high I 2 t, axial lead, ceramic tube fuses

M Series Half-inch Rotary Switches

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

AF40... AF96 3-pole contactors Technical data

DETAIL SPECIFICATION SHEET SWITCHES, TOGGLE, MINIATURE, LEVER SEAL, PANEL SEAL, FOUR POLE LOGIC LOAD TO 5 AMPERES

SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive)

4.7. Contents Description Heavy Duty Hesitation Switches. Product Description. Standards and Certifications. Heavy Duty Hesitation Switches

7000 Series Miniature Toggle Switches

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview

C&K 7000 Series Miniature Toggle Switches

Transcription:

MS-Series Circuit Breaker Carling Technologies MS-Series Sealed Toggle Circuit Breaker was designed and tested to operate flawlessly in the harshest of environments. Ideally suited for COTS (commercial off the shelf) military applications, the MS-Series features a durable metal and sealed mounting bushing with MIL-PRF-39019F ingress protection when mounted in a panel, and also meets IP68 requirement. This class-leading, affordable circuit breaker was also designed in accordance with the requirements of MIL- PRF-55629 and MIL STD 202, making it the best choice when the application consideration includes shock, vibration, moisture resistance, salt spray and thermal shock. The MS-Series compact size and reliability make it ideal for ruggedized communication equipment and other mission critical equipment. Features: Sealed toggle actuator MIL-PRF-39019F ingress protection MIL-PRF-55629 and MIL STD 202 compliant Compact design COTS Military Applications: Vehicles Communication equipment Generators Power supplies Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062 Phone: (860) 793-9281 Fax: (860) 793-9231

2 MS-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL & CSA Configuration & Performance Capabilities CIRCUIT CFIGURATI MAX. RATING MS-SERIES TABLE A: COMPENT SUPPLEMENTARY PROTECTORS SHORT CIRCUIT VOLTAGE CURRENT RATING CAPACITY (AMPS) POLES UL/CSA BREAKING FREQ PHASE FULL AMPS GENERAL PURPOSE AMPS WITH BACKUP FUSE WITHOUT BACKUP FUSE APPLICATI CODES 50 DC --- --- 0.02-30 1 --- 3000 TC1,2,OL0,U3 TC1,2,OL0,U3 50 DC --- --- 0.02-30 1 --- 8000 TC1,2,OL0,U1 TC1,2,OL0,U1 UL CSA Electrical Current Ratings Voltage Rating Short Circuit Rating Dielectric Strength Insulation Resistance Time Delay Impedance Mechanical Current Ratings Trip Free Trip Indication.20-30 Amps 50VDC See Table A UL,CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals Minimum of 100 Megohms @ 500VDC See delay curve 0.20-30.0 25% 10,000 On-Off operations @ 6 per minute with rated current and voltage Trips on short circuit and overload, even when the actuator is forcibly held in the On position The operating handle moves positively to the Off position when a short circuit or overload causes the circuit breaker to trip. Physical Number of Poles Weight Dimensions Agency Certifications UL Standard 1077 CUL Standard C22.2 1 pole Approximately 1.8 oz (50 G) per pole See form & fit drawing Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100G s, 6ms, saw tooth while carrying rated current per Method 213, Condition I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060 excursion from 10-55 Hz, and 10G s 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs) Moisture Resistance Thermal Shock Operating Temperature Ingress Protection Level Other Method 106G Method 107D, Condition A (Five cycles @ -55 C to +25 C to +85 C to +25 C -40 C to +85 C MIL-PRF-55629C when mounted in panel. Materials used in this product shall be non-nutrient to fungus growth *Manufacturer reserves the right to change product specification without prior notice.

MS-Series Circuit Breaker - Ordering Scheme 3 M S 1 B 14 615 3 1 C B A C 1 Series 2 Actuator 3 Poles 4 Circuit 5 Frequency & Delay 6 Current Rating 7 Terminal 8 Actuator Color 9 Front Panel Hardware 10 Legend Plate 11 Brushing Color 12 Agency Approval 1 SERIES M 2 ACTUATOR S Sealed Toggle 7 TERMINAL 1 Push-On 0.250 Tab (QC) 2 Screw 8-32 w/upturned lugs 8 ACTUATOR COLOR 1 Dull Metallic 3 Screw 8-32 (Bus Type) L Solder Lug 3 POLES 1 One 4 CIRCUIT B Series Trip (current) 9 FRT PANEL HARDWARE A No Outer Panel Hardware B Hex Nut, Nickel Plated C Hex Nut, Nickel Plated with Locking Ring F Panel Dress Nut, Nickel Plated G Panel Dress Nut, Nickel Plated with Locking Ring 5 FREQUENCY & DELAY 10 DC Instantaneous 12 DC Short 14 DC Medium 6 CURRENT RATING (AMPERES) CODE AMPERES 10 LEGEND PLATE A No Legend Plate B On-Off Vertical C On-Off Horizontal D I-O Vertical E I-O Horizontal 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.00 512 1.25 415 1.50 517 1.75 420 2.00 522 2.25 425 2.50 527 2.75 430 3.00 435 3.50 440 4.00 445 4.50 450 5.00 455 5.50 460 6.00 465 6.50 470 7.00 475 7.50 480 8.00 485 8.50 490 9.00 495 9.50 610 10.00 710 10.50 611 11.00 711 11.50 612 12.00 712 12.50 613 13.00 614 14.00 615 15.00 616 16.00 617 17.00 717 17.50 618 18.00 619 19.00 620 20.00 622 22.00 624 24.00 625 25.00 630 30.00 11 BUSHING COLOR A Nickel Plated 12 AGENCY APPROVAL A Without approvals C UL & CUL Recognized

4 MS-Series Circuit Breaker - Form & Fit Drawings Form & Fit Ø.125 X.062[1.57] [3.18] MINIMUM DEPTH.325 [8.26] Ø.391 [9.93] PANEL MOUNTING DETAIL 3/8-32 HEX NUT LOCKWASHER - INDICATOR PLATE +.007.373 -.041 +0.17.325 [8.26] Ø.125 X.062[1.57] [3.18] MINIMUM DEPTH Ø.391 [9.93] 3/8-32 HEX NUT LOCKWASHER - INDICATOR PLATE 1.634 ±.020 +.007 [41.50 ±.373 0.50] -.041 1.880 ±.031 +0.17[47.75 ± 0.78] Ø.170 [4.32] PANEL MOUNTING DETAIL 1.634 ±.020 [41.50 ± 0.50] 3/8-32 HEX 1.880 NUT±.031 LOCKWASHER [47.75 ± 0.78] - INDICATOR PLATE #8 SCREW TERMINAL SOLDER +.007 LUG TERMINAL.373 -.041 +0.17 1.634 ±.020 [41.50 ± 0.50] 1.880 ±.031 [47.75 ± 0.78] Ø.170 [4.32] #8 SCREW TERMINAL SOLDER LUG TERMINAL

MS-Series Circuit Breaker - Delay Curve 5 Delay Curve Dual Rated AC/DC Instantaneous Short Medium REV_CB_MS_01_2014