TAG-DR Series. Indoor or Outdoor LED Driver Box - TAG LED Flood Solutions. Specifications. Overall Dimensions For Reference Only TAG-DR

Similar documents
EMERY SKY SUSPENDED LED LUMINAIRE

IMPORTANT SAFETY INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

CASCADE LED LIGHT BAR

Overall Dimensions. Specifications

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

HPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature:

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Technical Manual. DLM Module. This manual should remain with the unit.

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

EDGE EV3WET 3 Recessed Linear WET

Remote Sensor Kits. Installation Manual. Document No (Revision C)

diode led FLUID VIEW 12V LED Tape Light 12VDC FEATURES Soft illumination Accent or ambient lighting Closet-safe Largest CCT selection QUICK SPECS

OP2 CosmoPolis Series

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

LED IMPORTANT SAFETY INSTRUCTIONS

EDGE EX6WET 6 Suspended Direct Linear WET

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

INSTALLATION INSTRUCTIONS

Overall Dimensions. Specifications

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

LED Utility Wrap Fixture

PGA Parking Garage Luminaire

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

NANOTUNE. Installation Manual

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

Options. Pole and Arm. Suitable for wet locations

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

Denali Fairbanks Yukon

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

PrevaLED Line High Flux

Applications. Illustrated Features

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

FPF LED SERIES F P F L E D. Linear Non-Metallic Fixture for Food Processing

Max. Input Power (W) Inrush Current (A pk /µs)

Installation Instructions

APPENDIX B: LISTS OF APPROVED MATERIALS

Installation Instructions Electric Heaters 5 20 kw

Capella 3. Project Name. Construction. Optical System. Product Applications

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

INSTALLATION INSTRUCTIONS

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

Owner's/Installation Manual

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

DALI 650mA LED Driver

CFP-LED Contractor Select Flat Panel. Installation Instructions

A3Z OPERATING MANUAL

7 Watt Compact Aluminum LED Fixture for Hazardous Area Location Lighting - No Mounting Bracket

HPNLS-HO. Installation Manual

Model Numbers SAVI-NOTE75, SAVI-NOTE150

User Manual. Solar Charge Controller 3KW

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

MS Application. Features. Proportional Valve Actuator General Instructions

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

V-Bollard Architectural LED Luminaire / Bollard

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

LED Parking Garage. Optional motion sensor

20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

V-Bollard Architectural LED Luminaire / Bollard

Installation Instructions Central Battery Units

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

Circa Ambient Interior Luminaire

SAVE THESE INSTRUCTIONS

MaxLite LED UTILITY WRAP FIXTURES

E.S.P. Embedded Sensing Probes for Motor Brushes

General Installation Instructions LED

TET120013RDXX-X1,TEMUNV013RDXX-X1 TKT120013RDXX-X1,TKMUNV013RDXX-X1

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

Installation Instructions Electric Heaters 5 20 kw

16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2

ACI Hoist & Crane. Festoon System. 689 S.W. 7th Terrace Dania, FL (954) Fax (954) Toll Free A-HOIST ( )

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

CONTROL FEATURES AVAILABLE OPTIONS

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

M-3025CB-AV Fuel Pump

Type 4 Panel Enclosures

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Transcription:

Catalog Number: Approvals: TAG-DR Series Box Driver Voltage Options Finish Type Wattage Date: Page 1 of 6 Overall Dimensions For Reference Only TAG-DR * Indoor Box 3.1" (7.8 cm) 9.1" (23.1 cm) 8.9 (22.7 cm) 3.1" (7.8 cm) Optional DMX In 3.1 (7.8 cm) 1.9" (4.8 cm) 1.8 (4.6 cm) Line Voltage In (120-277V) Optional DMX In IND 6.1" (15.4 cm) 12.1" (30.9 cm) 10.0" (25.4 cm) Line Voltage In (120-277V) Optional DMX Out Optional DMX In Wet Location Box 2.6 (6.6 cm) Optional DMX Out 12.3 (31.2 cm) 2.3 (5.8 cm) 6.1 (15.5 cm) 3.2 (8.1 cm) Optional DMX In WL Optional Photocell Button Shown 24VDC Out *optional DMX and thru-wire connectors shown (see wiring diagrams for details) 12.2" (30.9 cm) 0.3 dia. (0.8 cm) *0.25 anchors by others 24VDC Out 4.2" (10.6 cm) 1.5" (3.8 cm) *optional DMX and thru-wire connectors shown (see wiring diagrams for details) 13.25" (33.7 cm) 12.3 (31.2 cm) 6.3 (16.0 cm) 14.8" (37.5 cm) 13.5 (34.3 cm) 0.32 dia. (0.8 cm) 10.0 (25.4 cm) *0.25 anchors by others 12.75 (32.4 cm) Specifications Rated Life 100 Watt - 75,000 at a 40 C ambient. 150 to 300 Watt - 50,000 at a 40 C ambient. Indoor Driver Box / Construction Formed steel housing with (12) individual knockouts for various standard and optional wiring connections, including line voltage-in, 24VDC-out, optional DMX-in/out, and optional thru-wiring. Includes line voltage-in and 24VDC-out strain reliefs installed. Optional TW thru-wire strain relief is installed if ordered. Optional DMX in/out strain reliefs (2) are provided with box if ordered. Stamped steel cover, held in place with (4) corrosion resistant phillips head screws. Optional tamper proof screws available. Available in a painted finish only (see Finish section for details). Suitable for indoor use only. Wet Location Driver Box / Construction Formed steel or 304 stainless steel housing with (2) individual strain reliefs installed for standard wiring connections, including line voltage and 24VDC out. Additional strain reliefs provided for optional DMX in/out (1/2 NPT holes come plugged). Optional TW thru-wire strain relief is installed if ordered. All seams are sealed with continuous welds that are ground smooth. Door/cover is formed steel or stainless steel and uses a pull stainless steel continuous hinge pin to remove door if necessary. Door is accessed via (2) #1/4-28 stainless steel screws and clamps. Optional tamper proof screws available. Housing and door are sealed with a seamless EPDM foam-in-place gasket and is rated IP65. Available in a painted finish or unpainted stainless steel (see Finish section for details). Suitable for indoor and outdoor use. Drivers High efficiency multi-volt driver (50 or 60hz). High power factor (>90% standard). Constant voltage: 24V DC. Input Voltage: 120-277. Temperature range: -35 C (-31 F) to 40 C (104 F). THD is 20% max. Open / short circuit protection. Off-state power consumption is 0.0 watts. RoHS compliant. Mounting Indoor and outdoor boxes are supplied with (4) 0.32 mounting holes (see dimensional drawings for spacing details). Field installed driver boxes shall be mounted using (4) 0.25 anchors (supplied by others). Finish Painted indoor and outdoor boxes are available in a gray ANSI 61 polyester powder coat finish. Boxes and covers are painted inside and out. Outdoor box is also available in stainless steel with a brushed #4 finish. Cradle to Cradle Recycling To minimize environmental impact at end of product life cycle, the C2C product recycling assistance program is available (must be specified separately with the TAG LED floods). Listings ETL/cETL Listed luminaire, to the UL 1598 standard, suitable for Wet Locations. The quality systems of this facility have been registered by UL to the ISO 9001 Series Standards. Warranty / Terms and Conditions Standard 5 Year Limited Warranty. The current Philips Wide-Lite Warranty may be found at www.wide-lite.com (keyword: warranty) as well as the current Standard Terms and Conditions of Sale (keyword: terms).

Wet Location & Indoor Driver Box Page 2 of 6 Wet Location Box (stainless steel option shown) Indoor Box (standard gray shown) Series Box Type Driver Wattage Voltage Options Finish TAG-DR WL Wet Location Box 100 120 1 DMX 2 DMX Terminal Block GR Gray IND Indoor Box 150 208 1 TW Thru-wire SS 3 Stainless Steel 200 240 1 F1 Single Fuse (120/277V) 300 277 1 F2 Double Fuse (208/240V) PCB Photocell Button TP Tamper Proof Screws Notes: 1. Line voltage in to drivers. Drivers output 24VDC. 2. DMX option recommended for use with ColorDial or 3rd party DMX system. 3. Stainless Steel finish only available with WL Wet Location Box option. Driver Data Driver Catalog Output Operating Minimum Driver RoHS Line Current System Wattage Number Voltage Temp Range Power Factor Type Compliant 120 / 208 / 240 / 277 Watts (max) 100 TAG-DR-XXX-100 24VDC -40 o ~ 40 o C 0.90 electronic yes 0.93 / 0.53 / 0.46 / 0.41 111W 150 TAG-DR-XXX-150 24VDC -35 o ~ 40 o C 0.96 electronic yes 1.39 / 0.80 / 0.69 / 0.60 167W 200 TAG-DR-XXX-200 24VDC -35 o ~ 40 o C 0.96 electronic yes 1.85 / 1.07 / 0.93 / 0.82 222W 300 TAG-DR-XXX-300 24VDC -35 o ~ 40 o C 0.96 electronic yes 2.78 / 1.60 / 1.39 / 1.20 333W

Page 3 of 6 Note: The wiring diagram should be used for reference only. There are multiple ways that TAG products can be installed by the electrical contractor. Wire sizing and DMX control wiring is per the discretion of the electrical engineer and/or installing contractor. All local electrical codes apply to wiring and installation. Please see TAG-RD and TAG-LN spec sheets (WLSP0284 and WLSP0283) for some typical fixture wiring examples. Please contact the factory if you need assistance or guidance in regards to determining what is the best solution for your specific project. Ground (green) Negative (white) Positive (black) Line Voltage-In (120-277V) Line Voltage Terminal Block Line-In Line Voltage-Out LED Driver (100 watt shown) (connects to next driver box) (wire to be supplied by others) Optional DMX-In (Off-the-shelf Controller/ ColorDial as required) Belden 1502R Multimedia Cable Twisted Data Pair w/ Shield Positive/Negative - 18 AWG (recommended use) (wires must be 100-110 OHM impedance) (wire to be supplied by others) Optional DMX Terminal Block 24VDC-Out (for ColorDial only) 24VDC-Out 24VDC-In 24VDC Terminal Block Additional knock-outs available with indoor box only Shield (bare) Data - (blue) Data + (white) Positive (red) Negative (black or blue) Optional DMX-Out (to 1st TAG unit in series) 24VDC-Out* (wire needs to be sized accordingly) (wire to be supplied by others) * If power splitting is req d, splitting must take place within 6 of the driver box location and must use minimum 10 AWG wire. Belden 1502R Multimedia Cable Twisted Data Pair w/ Shield Positive/Negative - 18 AWG (recommended use) (wires must be 100-110 OHM impedance) (to be supplied by others)

Page 4 of 6 24VDC Out Wire Sizing Chart Maximum Wire Length (FT) vs. Power Wire Conductor Size (AWG) Power Wire Conductor (AWG) Total Fixture Wattage/Run Total Fixture Wattage Per Driver 10 25 50 75 100 125 150 175 200 225 250 275 300 24 92.1 36.2 18.1 11.1 7.7 5.1 4.2 4.6 4.0 3.1 2.8 2.5 2.3 22 145.9 57.3 28.7 17.6 12.2 8.0 6.7 7.3 6.4 4.8 4.4 4.0 3.6 20 Maximum Total 310.3 122.0 61.0 37.4 26.0 17.1 14.3 15.6 13.6 10.3 9.3 8.4 7.7 18 Power Wire 492.8 193.7 96.8 59.3 41.3 27.2 22.7 24.7 21.6 16.4 14.7 13.4 12.3 Length/Run 16 785.3 308.7 154.3 94.5 65.8 43.3 36.1 39.4 34.4 26.1 23.5 21.3 19.5 From Driver 14 1248.0 490.5 245.3 150.3 104.6 68.8 57.4 62.6 54.7 41.4 37.3 33.9 31.1 Box 12 (Feet) 1983.8 779.8 389.9 238.8 166.3 109.4 91.2 99.4 87.0 65.8 59.3 53.9 49.4 10 3157.2 1240.9 620.5 380.1 264.7 174.1 145.1 158.2 138.4 104.7 94.3 85.8 78.5 8 5018.9 1972.7 986.4 604.3 420.7 276.7 230.6 251.6 220.1 166.5 149.9 136.3 124.9 Basic Wire Sizing Chart Instructions (please contact our Technical Sales department for additional assistance if required): 1. Determine the total TAG fixture wattage of each independant run(s) requiring sizing (see TAG-RD and TAG-LN spec sheets for wattage details). 2. If the power run is to be split (must take place within 6 of the driver box location), each split can be treated as an individual run. 3. Determine the required run length(s) to the last fixture for your installation in feet. 4. Take your total run wattage from Step 1, find the next highest wattage in the row Total Fixture Wattage. 5. Take your required run length from Step 3, scroll down to find the next highest run length in the column identified in Step 4. 6. Scroll left to the column Power Wire Conductor (AWG) to select the proper wire gauge to power the required run length for your installation. Split Run Example: (6) TAG-RD-30-NW X1/Y1 = 6 ft X2/Y2 = 75 ft X3/Y3 = 20 ft 1. Wattage per fixture: 41W Total fixture wattage (6 total): 246W 2. Power run will be split to two equal runs minimize wire gauge requirements. Run X = 123W, Run Y = 123W 3. Req d run lengths: Run X = X1 + X2 + X3 = 101 ft, Run Y = Y1 + Y2 + Y3 = 101 ft 4. Next highest wattage in row Total Fixture Wattage : 125W 5. 1st Suitable run length in column 125W : 109.4 ft 6. Scroll left to 1st column: minimum 12 AWG power wire required Line Voltage-In 24VDC-Out Y1 X1 Note: X1 & Y1 must be less than or equal to 6. Minimum 10 AWG wire must be used prior to split. Run Y Power Split (j-box by others) Run X Y2 X2 Y3 X3

Page 5 of 6 Identification and Warnings of Safety Hazards: Read and understand these guides before installing any luminaire component Any Philips Wide-Lite related electrical component is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding. In accordance with ANSI Z535.4 the following system of identifying the severity of the hazards associated with the products is used: Danger Imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning Potentially hazardous situation that, if not avoided, could result in death or serious injury. Caution Potentially hazardous situation that, if not avoided, may result in minor or moderate injury or property damage. Warning: Ensure that main power supply is off before installing, wiring, or servicing any electrical component. Failure to adhere to these instructions can result in death or serious injury. Warning: All Philips Wide-Wide Products must be installed by a qualified professional in accordance with NEC and relevant local codes. Failure to comply can result in death, serious injury, or property damage. Warning: Do not attempt to install or use any Philips Wide-Lite product until you read and understand the installation instructions and safety labels. Failure to adhere to these instructions could result in serious injury or property damage. Caution: Do not modify or alter any Philips Wide-Lite product. Doing so will void the warranty. Owner/User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate all Philips Wide-Lite equipment in such a manner as to comply with all state and local laws, ordinances, regulations, and the American National Standard Institute Safety Code.

Notes: Page 6 of 6