These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Similar documents
Installation and Operating Instructions Electric Vibrators HV/VFL Series

Installation and Operating Instructions Magnetic Vibrator MR 1

Swing Piston Compressors and Vacuum Pumps

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Installation manual portable distributors

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Wilo-Control SC-Fire Jockey

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Support T10552 T10595 T40386

Solenoid Operator 0513 / 1213

RESOL SBS 1000 * * Connection Operation

Installation and Operating Jan Instructions for Netter. Electric External Vibrators Page 1/28. These operating instructions apply to: Series NEG

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Solenoid Operator 0516 / 1216

Operating Instructions

Installation manual wall-mounted distributor

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

3. Operating instructions: Minor 200

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Operating Instructions for Roll-Up Door Operators / MDF

Instructions for Use Plain Trolley ULK Geared Trolley UHK

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Installation Instructions

PURE SINE WAVE DC TO AC POWER INVERTER

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

User Manual Hoof trimmingcrush:sa0010. Version: User manual. Hoof trimming crush SA0010

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Mod: KLD6-12/35XLAS-N

DeltaSol AX * *

Compensation unit AGE-XY 50-80

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Operating Instructions

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Appendix: Safety and application notes for... 15

Diaphragm Vacuum Pumps and Compressors

Instruction Manual. Sewage lifting station compli 300

Battery Charger JCB- SCH20LI.2

Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

Assembly and Maintenance Manual Type ASNU

Operating instructions

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Diaphragm-Gas Sampling Pumps

Operating manual eviro vibration motors series A12

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Exchange of rollers from the XTS-Mover

Battery Charger JCB-FCH20LI2

Swing Piston Compressors and Vacuum Pumps

Assembly and Maintenance Manual Type AS

Installation instructions. Adapter AD 01 AD 02 AD 03

Diaphragm Vacuum Pumps and Compressors

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Linear unit, pneumatic KHM 40

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 12

Translation of the Original operating instructions Lifting device Z 70 /...

Instruction manual. CSV 402 caravan power supply. Table of contents

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Diaphragm Vacuum Pump

Operating Instructions

Analytical Diaphragm Pump Series MP MP06, MP12

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Diaphragm Vacuum Pumps and Compressors

TURBOTRONIK NT 151/361

Operating Instructions

Micro Diaphragm Gas Sampling Pumps

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Operating Instructions

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

OPTIFLUX 2000 Quick Start

Oil-free piston compressors KK and piston vacuum pumps KV

Instruction manual Electric glass door lock Touch-to-open

Motorized roller MRA50

Rotary modules CR 12 / CR 16 / CR 20

Electromagnetic single-face clutch. Operating Instructions E00 ACTIVE CLUTCH LINE

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Operating instructions Solenoid interlock EX-AZM About this document. Content

HST -LS Interlocking device (Translation of Original Manual)

Assembly and Maintenance Manual Type RSBW

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

Transcription:

Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Important note: Before use of the pneumatic linear vibrators series NCX and NCZ read this operating instruction carefully and store afterwards. Netter GmbH does not assume liability for damage to property and persons if the product has been technically modified or if the notes and regulations of these operating instructions have not been observed. This documentation is copyrighted. All rights, e.g. for translation into other languages, reprinting and copying of these operating instructions or parts hereof remain strictly reserved.

Contents 1 General notes... 2 2 Technical data... 3 3 Design and function... 4 4 Safety... 4 5 Transport and Storage... 7 6 Start-up / Operation... 7 7 Troubleshooting... 8 8 Appendix... 8 8.1 Disposal... 8 8.2 Enclosures... 8 Scope of delivery: Check the packaging for possible signs of transport damage. In the event of damage to the packaging, check that the contents are complete and undamaged. If there is any damage, inform the shipping agent. Compare the scope of the delivery with the delivery note. 1 General notes Netter electric internal vibrators series NCX and NCZ comply with the EC-Machinery Directive 2006/42/EC, the Electromagnetic Compatibility Directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The NCX and NCZ electric internal vibrators generate undirected (circular) vibrations and are used exclusively for compacting concrete. Their high centrifugal force enables an excellent compaction performance with optimal air void which requires modern concrete technology. Special features: High centrifugal force leads to a rapid and reliable concrete compaction Full protection of the electrical part by thermal sensors Components can be replaced quickly without special tools Steel or vulcollan nosepiece Impact-resistant hand switch 2

The following instruction and warning symbols are used in these operating instructions. Notes on important procedures Important note on procedures to be especially observed Warning of a danger spot Warning of dangerous electric voltage Disconnect unit from power supply, pull electric plug Environmental waste disposal 2 Technical data Nominal voltage, nominal frequency: 42 to 48 V, 200 Hz or 250 V, 200Hz Frequency: 12,000 min -1 Protection: IP 44 (hand switch) Ambient temperature: 0 C to 40 C Temperature must not be exceeded or fallen short of. NCX Series Type diameter length weight Total - weight Hose length* Cable length* Nominal frequency [min -1 ] Centrifugal force [N] Effective diameter Voltage* [mm] [mm] [kg] [kg] [m] [m] [cm] [V] [kw] NCX 380 39 370 2,9 9,5 5,0 10 12.000 1.200 40 7 42-48 0,5 NCX 380 S 39 370 2,9 5,0 0,8 15 12.000 1.200 40 7 42-48 0,5 NCX 480 49 375 4,7 15,2 5,0 10 12.000 3.000 55 18 42-48 1,3 NCX 480 S 49 375 4,7 6,2 0,8 15 12.000 3.000 55 18 42-48 1,3 NCX 580 L 59 400 7,8 17,0 5,0 10 12.000 4.800 65 25 42-48 1,8 NCX580 LS 59 400 7,8 7,8 0,8 15 12.000 4.800 65 25 42-48 1,8 NCX 660K 66 415 9,0 19,5 5,0 10 12.000 6.000 85 28 42-48 2,0 * Other voltages, cable lengths and hose lengths on request. NCZ Series Type diameter length weight Total weight Hose length* Cable length* Nominal frequency [min -1 ] Current consumption [A] Centrifugal force [N] Effective - diameter Current consumption [A] Voltage* [mm] [mm] [kg] [kg] [m] [m] [cm] [V] [kw] NCZ 300 32 320 1,7 7,9 5,0 10 12.000 1.160 40 8 42-48 0,6 NCZ 300 S 32 320 1,7 6,6 0,8 15 12.000 1.160 40 8 42-48 0,6 NCZ 370 S 38 360 2,9 9,6 5,0 10 12.000 1.400 45 8 42-48 0,6 NCZ 370 S 38 360 2,9 5,0 0,8 15 12.000 1.400 45 8 42-48 0,6 NCZ 480 49 400 5,1 14,2 5,0 10 12.000 3.100 60 15 42-48 1,1 NCZ 480 S 49 400 5,1 6,2 0,8 15 12.000 3.100 60 15 42-48 1,1 NCZ 560 58,5 400 6,8 15,9 5,0 10 12.000 4.850 65 23 42-48 1,6 NCZ 560 S 58,5 400 6,8 6,8 0,8 15 12.000 4.850 65 23 42-48 1,6 NCZ 560 L 58,5 450 7,8 16,8 5,0 10 12.000 6.100 75 21 42-48 1,5 NCZ 560 LS 58,5 450 7,8 9,2 0,8 15 12.000 6.100 70 21 42-48 1,5 NCZ 660 66 510 11,4 21,4 5,0 10 12.000 8.500 110 27 42-48 1,9 NCZ 800 80 440 13,8 29,0 5,0 10 12.000 10.470 160 35 42-48 2,5 * Other voltages, cable lengths and hose lengths on request. Power (42 V) Power (42 V) 3

3 Design and function The NCX and NCZ internal vibrators consist of a stator, rotor and the outer sleeve with a steel or vulcollan nosepiece. The stator with a low loss factor, has a high efficiency. The special roller and needle bearings are designed for heavy loads and high compaction performance. The vibration is generated by an unbalance that rotates around a shaft. The unbalance of the NCZ is mounted with slip joint on the rotor. This keeps the starting current low as well as the wear of the bearings. In the NCX vibrators the unbalance is fastened directly on the rotor. The NCX and NCZ internal vibrators are switched on by pressing the hand switch and then slowly inserted into the concrete. Once the required compaction level has been reached, the vibrators are pulled out slowly and switched off. 4 Safety Nominal voltage, nominal frequency: 42 to 48 V, 200 Hz or 250 V, 200Hz Frequency: 12,000 min -1 Protection: IP 44 (hand switch) Ambient temperature: 0 C to 40 C Operating temperatures must not be exceeded or fall short of. Only persons over 18 years and trained in working with internal vibrators (prevention of accidents regulations) are authorised to operate the internal vibrators. Protection The vibrators are protected, against thermal overheating by three thermal sensors which switches off the vibrators in case of overheating. Special personal protection in accordance with DIN, VDE and CE is ensured by an isolating transformer on the output terminal of the frequency converter. Attention HEALTH RISK. Do not hold or touch the vibrator element during operation! 4

Declaration of Conformity September 2010 Electric Internal Vibrators Declaration of Conformity according to EC directive 2006/42/EC on machinery (Annex II 1 A) We hereby declare, that the electric internal vibrators series NCX and NCZ are in accordance with all relevant provisions of the above machinery directive. Furthermore the partly completed machineries comply with the regulations: low voltage regulation 2006/95/EG and electromagnetic compatibility 2004/108/EG Applied harmonized regulations are: DIN EN ISO 12100 part 1/A1:2009-10 DIN EN ISO 12100 part 2/A1:2009-10 DIN EN ISO 60034-1 amendment 1:2007-09 The relevant technical documentation is compiled in accordance with part A of annex VII. The authorized person who compiled the relevant technical documentation in accordance with annex II digit 1 part B. No. 2, 2006/42/EC is Michael Möller. Mainz-Kastel, 17.09.2010 i.a. A. Werkmann (Quality Manager)

Parts under voltage or rotating parts can cause serious or fatal injuries. The operator of vibration devices must protect employees against actual or possible risks to their health and safety from the effects of vibration Incorrect installation of the vibrators can cause to fail the vibrators and lead to serious or even fatal injuries. All transport, installation and start-up work as well as maintenance must be carried out by specially qualified personnel (observe IEC 364 or DIN VDE 0100 and IEC 664 or DIN VDE 0110). Repairs to the vibrator or its components must only be done by authorised personnel for safety reasons and to comply with the documented system data and functions. The internal vibrators are built according to current EC directives. When installing and operating the vibrators, the conditions and regulations of the local electrical engineering associations (e.g. VDE) and the familiar accident prevention regulations shall be observed. Any modification to the unit can change the properties of the electric internal vibrators or damage the unit and lead to all warranty claims being rejected. Non-compliance with the operating instructions also results in the rejection of all warranty claims. Permitted operating conditions: The vibrators must not be used in a potentially explosive environment. When working on the internal vibrator, it must be safely disconnected from the frequency converter. Please proceed as follows: 1. Switch off 2. Protect against being inadvertently switched on 3. Ensure unit is voltage-free The proper condition of electrical cables with connectors should be checked at regular intervals (at least every six months). Any faults discovered must be immediately rectified. Take care that the cables are not worn through by vibrating parts. Always pull the internal vibrator slowly out of the concrete while still running, otherwise there is a risk of the protective hose being pulled off the vibration head. 6

5 Transport and Storage Check the packaging for possible shipping damage. If the packaging is damaged, check the contents for completeness and possible damage. In case of damage inform the transport agent. The units are packed ready for installation. The type designation is located on the top part of the head. When transporting the internal vibrators, take care that they are not exposed to any heavy impact. The units should be stored in a dry and clean environment. After a storage period of more than 2 years, the vibrators must be electrically tested. 6 Start-up / Operation Attention HEALTH RISK. Do not hold or touch the vibrator element during operation! Before start-up, make sure that the internal vibrator shows no signs of visible damage. The unit is connected to the CEE socket (vibration-resistant plug connector) of a suitable frequency converter e.g. Netter NFC. Check the type designation on the internal vibrator, compare the technical data with the details on the frequency converter and check the nominal voltage and the average power consumption. The units are protected against thermal overheating by three thermal sensors. They switch off the vibrator automatically in case of overheating. Start-up The unit starts after pressing the on / off switch. For compaction, slowly and fully insert the vibration head (for better cooling) into the concrete vertically, diagonally or horizontally depending on the concrete depth. Once the required compaction level has been reached, pull out the unit slowly and switch it off. Internal vibrators should only be operated for a short time outside of the concrete (overheating). In unfavourable temperature conditions, there is an increased risk that the builtin thermal fuse for protection against over-heating will automatically switch off the vibrator. If this does happen, let the vibrator cool off for a few minutes before switching on again. Keep sufficient distance (1-2 times the head diameter) of wall formwork and reinforcement one. Strong impacts to the head may damage this. 7

7 Troubleshooting Short-circuit, earth fault, phase failure In case of short-circuit, earth fault or phase failure on the vibrator, the frequency converter breaks down. In this case change the vibrator. In case of problems with the internal vibrator, it is recommended to send in the whole unit for repair. 8 Appendix 8.1 Disposal Depending on the material, the parts must be disposed of according to official regulations. Material specifications: Steel NCX stator, rotor, unbalance, bearings, outer sleeve, nosepiece, spacer, pin, inner ring NCZ stator, rotor, bearings, outer sleeve, nosepiece, spacer Bronze unbalance PTFE gaskets gaskets All devices can be disposed of through Netter GmbH. The applicable disposal prices are available upon request. 8.2 Enclosures Enclosure(s): Declaration of conformity Additional information available upon request: Leaflet No. 1 NCZ and 3 NCX, and much more 8