Electromagnetic amplifier type ModMAG M10 for all detectors

Similar documents
Electromagnetic amplifier Primo Advanced for all detectors

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Electromagnetic Flowmeters. Product Overview.

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Magnetic-inductive flow meter for hazardous areas

유량계전문제조업체. Electro Magnetic FLOWMETER

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

Flow Measurement & Control

Electromagnetic Flow Meter Owner s Manual HARDWARE

Full Profile Insertion

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

ISTEC MAGNETIC METERS

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Industrial OG meter series IOG Inline and flanged oval gear meter

Flow meter Type Recordall (RCDL)

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

OPTIFLUX 6000 Technical Datasheet

Magnetic-Inductive Flow Meter FMI

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

Options guide. Electromagnetic flowmeters. M9xx

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Magnetic-Inductive flow Meter fmi

F6700 ELECTROMAGNETIC METER

BATCHFLUX 5500 C Technical Datasheet

SITRANS F M flow sensors 711/A and 711/911E

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

ProcessAutomatic EZ-Mag

Electromagnetic Flow Monitor magphant

Rosemount 8750WB Magnetic Flowmeter System

PROCESSAUTOMATIC MAGNETIC FLOWMETER

Electromagnetic Flow Measuring System PROline promag 10 W

OPTIFLUX Electromagnetic Flow Sensor

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Technical Information Proline Promag 10L

HENRI Flowmeter for Pulp Slurry

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Magnetic-Inductive Flow Meter FMQ

INLINE fitting with paddle-wheel for flow measurement

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Model DFX Doppler ultrasonic flow meter

Detector (for water measurement applications)

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Botlek Studiegroep Basics Electro Magnetic Flowmeters

WATERFLUX 3000 Technical Datasheet

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

Magnetic Inductive Flow

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Electromagnetic Flow Monitor magphant

Water Solutions For Global Needs

Insertion Flow Meters. Municipal Market Customer Presentation

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

INLINE fitting with paddle-wheel for flow measurement

SITRANS F M. Flow sensor MAG 1100 F 3/59

OPTIMASS 3000 Technical Datasheet

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

FT-3100 ONICON. Inline Electromagnetic Flow Meter Installation and Operation Manual. Flow and Energy Measurement

MagFlux Q 8200 Series

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

Flow Measurement SITRANS F M

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-2600 SERIES INLINE VORTEX FLOW METER

Level switches Series LC40 Float level switch for liquids

Range of Ultrasonic Flowmeters.

imag 4700 SERIES FLANGED MAGMETER

Spiraflo Steam flowmeters

WATERFLUX 3070 Technical Datasheet

Flow Measurement SITRANS F M

Electromagnetic flowmeter EMKO E

F-1500 SERIES INSERTION TURBINE FLOW METER

SHENITECH, LLC

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

OPTIGAS 4010C Technical Datasheet

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Badger Meter Europa. Flow Measurement and Control. Flow metering, batching, controlling

Metal tube variable area flowmeter for gases, liquids and steam

Electromagnetic flowmeters

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems.

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

Proline Promag 10L. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications

INSERTION fitting for flow measurement or analysis

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Positive Displacement Flowmeters

Proline Promag W 400. Technical Information. Electromagnetic flow measuring system The specialist for all water and wastewater applications

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

F-2700 SERIES INSERTION VORTEX FLOW METER

Design and application

CM2-MGG User s Manual

OPTIGAS 4010C Technical Datasheet

Insertion magnetic inductive flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

Transcription:

Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Electromagnetic amplifier type ModMG M10 for all detectors 00 Features ccuracy ±0,3% Flow range 0,03 12 m/s 6 200 LC display RS232, RS485 and ModBus RTU Power supply 92-275 VC, 9-36 VC escription ModMG M1000 is best suited for bidirectional flow measurements of fluids > 5 µs/cm (> 20 µs/cm for demineralized water). Thanks to its excellent priceperformance ratio, ModMG M1000 can be chosen for a broad spectrum of applications. pplications The ModMG M1000 has been designed especially for applications in machinery plants, vehicles and batching processes. The applications range from 6 to 200 with the most various process connections like IN flanges, dairy pipe connections, TriClamp, etc. ll information like flow, total or error messages can be read-out from the backlit LC display. The standard model is provided with a great number of inputs, outputs and interfaces for lots of applications. ModMG M1000 is encased in an aluminium housing with protection class IP67 and therefore also ideal for use in harsh environments. imensions Measuring principle The operating principle of the electromagnetic flow meter is based on Faraday s law of magnetic induction: The voltage induced across any conductor, as it moves at right angles through a magnetic field, is proportional to the velocity of that conductor. The voltage induced within the fluid is measured by two diametrically opposed internally mounted electrodes. The induced signal voltage is proportional to the product of the magnetic flux density, the distance between the electrodes and the average flow velocity of the fluid.

Power supply 92-275 VC (50 / Hz), < 14 V optional 9-36 VC, < 4 W ccuracy 0,3 % of m.v., 2 mm/s Repeatability 0,1 % Flow range 0,03 12 m/s Conductivity min. 5 µs/cm (20 µs/cm for demineralized water) Flow direction bi-directional Programming 3 buttons optional RS232 Interface RS232, RS485, Modbus RTU nalog output 0/4-20 m / 0-10 m, flow direction is displayed upon a separate status output Pulse output 2 open collectors, passive 32 VC, 0-100 Hz 100 m, 100-10.000 Hz 20 m, optional active Frequency output max. 10 khz (open collector) Status output min/max. alarm, preselection, flow direction, error message, free configurable Empty pipe detection separate electrode Low flow cut off 0-10 % Housing Powder coated aluminium die cast Protection class IP67 Cable insertion 2 x M 20 mbient temperature -20 C up to + C etector type III Wafer connection Remote version Thanks to its very short lay length, the detector type III is often the right alternative to a lot of applications. elivered with a PTFE liner, the detector type III has a standard nominal pressure of PN 40. Mounted version M1000-02 Size 25 100 (1 to 4 ) Process Wafer connection (in-between flange mounting) connection Nominal PN 40 pressure Protection IP67, optional IP68 class Min. 5 µs/cm (20 µs/cm (for demineralized water) conductivity Liner PTFE -40 C to +150 C materials Elektrodes material Hastelloy C (Standard) Tantal Platinum / Gold plated Platinum / Rhodium Housing Carbon steel / optional stainless steel Lay length 25 50 25 50 100 100 imensions (mm) M1000-03 25 1 100 238 266 74 32 1 ¼ 100 243 271 84 40 1 ½ 100 248 276 94 50 2 100 253 281 104 2 ½ 150 266 294 129 3 150 271 299 140 100 4 150 279 307 156 Pressure PN 40

etector type II Flange process connection Remote version 122 d2 x n The electromagnetic detector type II is not only available in a number of different flange process connections (IN, NSI, JIS, WW, etc.) but also in a number of liners like hard rubber, soft rubber, PTFE, PF or Halar. vailable in sizes from 6 to 200 and nominal pressures up to PN 100, the detector type II is best suited for a variety of applications in the industry and the water/waste water industry. Lined measuring pipes with materials approved for drinking water: KTW/VGW, NSF-61, WRS, CS. Mounted version K d2 x n K M1000-04 M1000-05 Size 6 2000 (1/4 ) Process Flange: IN, NSI, JIS, WW, etc connections Nominal up to PN 100 pressure Protection IP67, optional IP68 class Min. 5 µs/cm (20 µs/cm for demineralized water) conductivity Liner Hard/soft rubber from 25 0 C up to + C materials PTFE 6 0-40 C up to +150 C Electrodes materials Hastelloy C (standard), Tantal Platinum / Gold plated, Platinum / Rhodium Housing Steel / Optional stainless steel Lay length 6 20 170 mm 25 50 225 mm 100 2 mm 125 200 400 mm imensions (mm) with NSI-flanges with IN-flanges Std* ISO** K d2xn K d2xn 6 1/4 170 --- 228 256 88,9,3 15,9 x 4 90 14 x 4 8 3/10 170 --- 228 256 88,9,3 15,9 x 4 90 14 x 4 10 3/8 170 --- 228 256 88,9,3 15,9 x 4 90 14 x 4 15 1/2 170 200 238 266 88,9,3 15,9 x 4 95 14 x 4 20 3/4 170 200 238 266 98,4 69,8 15,9 x 4 105 75 14 x 4 25 1 225 200 238 266 107,9 79,4 15,9 x 4 115 85 14 x 4 32 1 1/4 225 200 253 281 117,5 88,9 15,9 x 4 140 100 18 x 4 40 1 1/2 225 200 253 281 127 98,4 15,9 x 4 150 110 18 x 4 50 2 225 200 253 281 152,4,6 19 x 4 1 125 18 x 4 2 1/2 2 200 271 299 177,8 139,7 19 x 4 185 145 18 x 4 3 2 200 271 299 190,5 152,4 19 x 4 200 1 18 x 8 100 4 2 250 278 306 228,6 190,5 19 x 8 220 1 18 x 8 125 5 400 250 298 326 254 215,9 22,2 x 8 250 210 18 x 8 150 6 400 300 310 338 279,4 241,3 22,2 x 8 285 240 22 x 8 200 8 400 350 338 366 342,9 298,4 22,2 x 8 340 295 22 x 12 Standard with NSI-flanges from 6-200 Pressure LBS 150 with IN flanges from 6-200 Pressure PN 16 * Standard **ISO 13359

Sanitary detector for food Process connections Tri-Clamp, IN 11851, ISO 2852, etc. TriClamp, remote version 122 The sanitary detector was developed for the flow measurement of liquid food. This model is available with Tri-Clamp, IN 11851, ISO 2852 process connections and also with any special connections (customer specifications). The sanitary detector is delivered in a stainless steel housing and with PTFE lining. TriClamp, mounted version M1000-06 M1000-07 Size 10-100 (3/8 to 4 ) Process connections Tri-Clamp, IN 11851, ISO 2852, etc. Nominal pressure PN 10/16 Protection class IP67, optional IP68 Min. conductivity 5 µs/cm (20 µs/cm for demineralized water) Liner materials PTFE / PF PTFE / PF Electrodes materials Hastelloy C (Standard) Tantal Platinum / Gold plated Platinum / Rhodium Housing Stainless steel Lay length Tri-Clamp 10 50 145 mm connection 100 200 mm IN 11851 10 20 170 mm connection 25 50 225 mm 100 2 mm IN11851, remote version imensions (mm) type Food Tri-Clamp 122 M1000-08 10-145 228 256 74 15 1/2 145 228 256 74 20 3/4 145 228 256 74 25 1 145 228 256 74 40 1 ½ 145 238 266 94 50 2 145 243 271 104 2 ½ 200 256 284 129 3 200 261 289 140 100 4 200 269 297 156 Pressure PN 10 IN 11851, mounted version M1000-09 imensions (mm) type Food milk pipe IN 11851 10 3/8 170 238 266 74 15 1/2 170 238 266 74 20 3/4 170 238 266 74 25 1 225 238 266 74 32 1 ¼ 225 243 271 84 40 1 ½ 225 248 276 94 50 2 225 253 281 104 2 ½ 2 266 294 129 3 2 271 299 140 100 4 2 279 307 156 Pressure PN 16

Type Food Tri-Clamp BS4825/ISO2852 BS4825 ISO2852 Size I I - - - 10 50.5 14.0 1/2 25.0 9.4 15 50.5 18.1 3/4 25.0 15.75 20 50.5 22.9 1 50.5 22.1 25 50.5 28.7 1 ½ 50.5 34.8 32 64.0 38.4 2 64.0 47.5 40 64.0 44.3 2 ½ 77.5.2 50 77.5 56.3 3 91.0 72.9 91.0 72.1 3 ½ 106.0 84.3 106.0 84.3 4 119.0 97.4 100 130.0 109.7 PN 10 dimensions (mm)