INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RIGHT ANGLE FILTER Original Manual EN (0) 2019/02

Similar documents
INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

ИНСТРУКЦИЯ ПО УСТАНОВКЕ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ ПРЯМОЙ ФИЛЬТР INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RV PUMP

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS SINGLE-SEAT VALVE

PROGRESSIVE CAVITY PUMP KIBER KS / KST

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. Unique 7000 Series Aseptic - Manually Operated ESE02421-ENUS Original manual

Unique 7000 Series Valve - Standard and Reverse Acting

Instruction Manual. LKAP Air-Operated Valve ESE01993-EN Original manual

Instruction Manual. SMP-TO Sanitary Mixproof Tank Outlet Valve IM70785-GB

INNOVA SINGLE SEAT VALVE - N/K TYPE

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

Instruction Manual. SMP-BC Sanitary Mixproof Valve IIM70771-GB

PROGRESSIVE CAVITY PUMP KIBER KSF KSFT

Instruction Manual. Unique 7000 Series - Long Stroke ESE00220-ENUS Original manual

Instruction Manual. Unique Single Seat Valve - Long Stroke ESE00222-EN

CPM-I-D60 Constant-Pressure Modulating Inlet Valve

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

Instruction Manual. Unique Single Seat Valve - Tank Outlet ESE00364-EN Original manual TD _2

INNOVA DOUBLE SEAT VALVE S TYPE

Перистальтический насос PV60 PVT60

Instruction Manual. Alfa Laval Safety Valve ESE03058-EN Original manual

Instruction Manual. Unique RV-P, pneumatic regulating valve ESE02801-EN Original manual

By-pass valve BBZS1 - BBYS1

Instruction Manual. Unique RV-ST Regulating Valve ESE02127-EN Original manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS NLD/NTD SHUT-OFF VALVE WITH LEAK DETECTOR

Instruction Manual. Alfa Laval Safety Valve ESE03058-EN Original manual

Installation, Operation, and Maintenance Manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS LOBE PUMP

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS HYGINOX SE

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm

INSTRUCTION MANUAL. MIXPROOF ZAW Valve GB-IST-ZAW-0312

INSTALLATION, SERVICE S.A.U EN1 (A) 2018/111

MIXPROOF Valve B925 - B925B

KEYSTONE. Hygienic butterfly valves model F250 & F251 Installation & Maintenance Instructions. 1 Contents 1 Contents 1

MIXPROOF Valve B925 - B925B

BBZP Pneumatic Valve BBZR Long Stroke Pneumatic Valve BBZT Pneumatic Valve

Instruction Manual. SolidC Pump ESE00797-EN Original manual

Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum

Instruction Manual. MH Koltek Valve ESE01990-EN Original manual

Instruction, Use and Maintenance Manual BBZS5 - BBYS5

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Thermowell For sanitary applications Model TW61, for orbital welding

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Instruction Manual. Unique-TO Sanitary Mixproof Tank Outlet Valve ESE00156EN

Installation, Operation, and Maintenance Manual

Instruction, Use and Maintenance Manual ASEPTIC PNEUMATIC ON-OFF VALVE WITH BELLOWS

Instruction, Use and Maintenance Manual HIGH-PRESSURE PNEUMATIC VALVE BBZQ - BBYQ

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS PROLAC HCP

Operating Instructions Ball Valves

Angle seat valve with diaphragm actuator VZXA-...-M

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD

Installation, Operation, and Maintenance Manual

Reflex ex separator. Exvoid / Exvoid HC (HiCap) Exdirt / Exdirt HC (HiCap) Extwin /Extwin HC (HiCap) Operating manual

CSA products for waste water. Combination air valve. Mod. SCF 2

HLR Rotary Lobe Pump

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

GL Ludemann Y-Strainers

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

Plunger Heads Use and Maintenance Manual

Angle seat valve with piston actuator VZXA-...-K

These installation and maintenance instructions must be read in full and completely understood before the installation!

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

DeZURIK 2 20" BOS BUTTERFLY VALVES

Instruction Manual. Keofitt Aseptic Membrane Sampling Valve IM70783-GB

Instruction & Operation Manual

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product.

General Operating Manual

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

CSA products for treated water. Water Combination air valve. Mod. FOX 3F RFP and Lynx 3F RFP

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mod: KLD6-12/35XLAS-N

485 - NC NO/DA DN

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

Instruction Manual. Unique Single Seat Valve - Tank Outlet ESE00364-EN Original manual TD _2

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Instruction, Use and Maintenance Manual MODULATING VALVES BBZPM - BBYPM

Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Operating Instructions for Flow Indicator. Model: DAA

Application Pressure reducing valves for the food and pharmaceutical industries

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Operating instructions - Translation of the original -

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

T-smart Butterfly Valves. Made by GEA Tuchenhagen. GEA Mechanical Equipment / GEA Tuchenhagen

Declaration of Conformity as per Directive 97/23/EC

RADEX -N Composite Operating/Assembly instructions

Instruction Manual. SMP-BC Sanitary Mixproof Valve ESE02255-EN Original manual TD _1

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

Transcription:

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RIGHT ANGLE FILTER 82700 11.103.32.0001 Original Manual 11.103.30.02EN (0) 2019/02

EC Declaration of Conformity 11.103.30.03ES 11.103.30.03EN (0) 2019/01 (0) Manufacturer: INOXPA, S.A.U Telers, 60 17820 - Banyoles (Girona) We hereby declare that the following products: FILTER RIGHT ANGLE FILTER - 82700 Name Type Conform with the provisions of the Council Directive: Pressure Equipment Directive 2014/68/UE, the abovementioned equipment has been designed and manufactured in accordance with the requirements of this Directive Max. Operating pressure: DN - 25/1 à DN - 150/6 = 10 bar Diameter: DN - 25 X DN - 50 Equipment category: SEP = Sound Engineering Practice, determined according to Article 3 Section 3, first paragraph Annex II, table 1 This material SHALL NOT carry EC marking Diameter: X = DN - 65-80 Equipment category: Category I, determined according to Article 3, Section 1.1.a, first paragraph Annex II, table 1 This material SHALL carry EC marking. Conformity Assessment Module: Module A Diameter: X = DN - 100/125/150 These filters are subject to the following assessment procedure, Module A, Category I, fluids group 2. This material SHALL carry EC marking. In compliance with Regulation EC nº 1935/2004, relating to materials and articles intended to come into contact with food, the materials in contact with the product do not transfer their constituents to the product in quantities which could endanger human health. David Reyero Brunet Technical manager Banyoles, January 15th, 2019

1. Table of Contents 1. Table of Contents 2. Generalities 2.1. Instructions manual... 4 2.2. Compliance with the instructions... 4 2.3. Warranty... 4 3. Security 3.1. Warning symbols... 5 3.2. General safety instructions... 5 4. General Information 4.1. Description... 6 4.2. Operating principle... 6 4.3. Application... 6 5. Installation 5.1. Reception of the filter... 7 5.2. Identification of the filter... 8 5.3. Location... 9 5.4. Installation... 9 5.5. Final check... 9 5.6. Welding... 9 6. Start-up 7. Troubleshooting 8. Maintenance 8.1. General considerations... 12 8.2. Maintenance... 12 8.3. Cleaning... 13 8.4. Disassembly and assembly of the filter... 14 9. Technical Specifications 9.1. Materials... 15 9.2. Other features... 15 9.3. Dimensions and weights... 16 9.4. Exploded drawing and parts list... 17 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 3

Generalities 2. Generalities 2.1. INSTRUCTIONS MANUAL This manual contains information about the reception, installation, operation, assembly, disassembly and maintenance of the right angle filter 82700. Carefully read the instruction prior to starting the filter, familiarize yourself with the installation, operation and correct use of the filter and strictly follow the instructions. These instructions should be kept in a safe location near the installation area. The information published in the instruction manual is based on updated data. INOXPA reserves the right to modify this instruction manual without prior notice. 2.2. COMPLIANCE WITH THE INSTRUCTIONS Not following the instructions may impose a risk for the operators, the environment and the machine, and may result in the loss of the right to claim damages. This non-compliance may result in the following risks: failure of important machine/plant functions, failure of specific maintenance and repair procedures, possible electrical, mechanical and chemical hazards, risk to the environment due to the type of substances released. 2.3. WARRANTY Any warranty will be void immediately and lawfully and, additionally, INOXPA will be compensated for any civil liability claims submitted by third parties, in the following cases: the service and maintenance work have not been carried out in accordance with the service instructions, the repairs have not been carried out by our personnel or have been carried out without our written authorisation, modifications have been carried out on our material or equipment without written authorisation, the parts or lubricants used are not original INOXPA parts and products, the material or equipment has been improperly used, has been used negligently, or has not been used according to the instructions and their intended. The General Conditions of Delivery already in your possession are also applicable. The machine may not undergo any modification without prior approval from the manufacturer. For your safety, only use original spare parts and accessories. The usage of other parts will relieve the manufacturer of any liability. Changing the service conditions can only be carried out with prior written authorization from INOXPA. Please do not hesitate to contact us in case of doubts or if further explanations are required regarding specific data (adjustments, assembly, disassembly, etc.). 4 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Security 3. Security 3.1. WARNINGY SYMBOLS Safety hazard for people in general and/or for equipment ATTENTION Important instruction to prevent damage to the equipment and its functions 3.2. GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully before installing and using the filter for the first time. Contact INOXPA in case of doubt. 3.2.1. During the installation The Technical Specifications in chapter 9 should always be observed. The installation and use of the filter must always be carried out in accordance with applicable health and safety regulations. Before using the filter, verify that it is correctly assembled and that the clamp is securely closed. 3.2.2. During operation The Technical Specifications in chapter 9 should always be observed. Under no circumstances can the limit values specified be exceeded. Never touch the filter and/or the lines that are in contact with the liquid during operation. A burn hazard exists when working with hot products. 3.2.3. During maintenance The Technical Specifications in chapter 9 should always be observed. NEVER disassemble the filter until the pipes have been emptied. Bear in mind that the liquid in the line may be dangerous or extremely hot. Consult the regulations in effect in each country for these cases. Do not leave loose parts on the floor. INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 5

General Information 4. General Information 4.1. DESCRIPTION The filter basically consists of a filter body with an inlet and an outlet for the product. The screen is fixed inside the body. The screen retains all particles that are equal or larger than the size of the screen openings. They have a hygienic design and are used to filter particles capable of damaging pumps and other equipment. The filters are suitable for contact with food products. 4.2. OPERATING PRINCIPLE The liquid enters the filter and the largest solid particles are trapped by the strainer screen inside the filter. The filtered liquid exists through the filter outlet. 4.3. APPLICATION Filters have a wide range of applications in the food-processing, cosmetics and some chemical industries as well as in auxiliary services of the pharmaceutical industry. ATTENTION Do not modify the operating parameters for which the filter has been designed without prior written authorisation from INOXPA. 6 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Installation 5. Installation 5.1. RECEPTION OF THE FILTER INOXPA is not liable for any deterioration of the material caused by its transport or unpacking. Visually check that the packaging has not been damaged. The first thing to do on receiving the filter is to check it and verify that it matches the delivery note. INOXPA will inspect all the equipment before packing, although it cannot guarantee that the merchandise will arrive intact to the user. Ensure that the filter has not been damaged in any way. If it is not in good condition and/or any parts are missing, the carrier must submit a report as soon as possible. The following documentation is included with the filter: shipping documents, instructions and servicing manual for the filter. INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 7

Installation 5.2. IDENTIFICATION OF THE FILTER F 0 330-11 06 52 050 101 Strainer type PERFORATED SHEET: ROUND WEDGE WIRE SCREEN 005 0,05 mm T05 0,05 mm 010 1,0 mm T10 0,1 mm 020 2,0 mm T20 0,2 mm 025 2,5 mm T30 0,3 mm 050 5,0 mm T40 0,4 mm PERFORATED SHEET: LONGITUDINAL 101 10 x 1 mm Nominal diameter 025 DN 25 (DN 1 ) 032 DN 32 (DN 1 ¼ ) 040 DN 40 (DN 1 ½ ) 050 DN 50 (DN 2 ) 063 DN 2 ½ 065 DN 65 076 DN 3 080 DN 80 100 DN 100 (DN 4 ) Seal material 40 NBR 52 EPDM 80 FPM Body material 06 AISI 316L Connection type 00 Welded 11 Male 33 Nut 77 Clamp 88 Flange Filter type 130 Straight filter 230 Y-filter 330 Right angle filter Connection type 0 DIN 11851 1 OD ASME 2 SMS FRANCE 3 GAS DIN 259 4 ASEPTICO DIN 11864 5 ASEPTICO DIN 11864 PULGADAS 6 RJT UK 7 MACON FRANCE 8 FIL Product family F Filters 8 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Installation 5.3. LOCATION Place the filter in such a way as to facilitate inspections and checks. Leave sufficient space around the filter for appropriate inspection, separation and maintenance. It is very important to ensure that enough space is available for removing the strainer screen. 5.4. INSTALLATION Once the filter has been installed at the desired location it can be connected to the pipeline by welding the filter body or by means of accessories (connectors). Excessive stress should be avoided during the installation of the filter and special attention should be given to the following: vibrations which may be produced during the installation, the expansion of the lines during the circulation of hot liquids, the weight that the lines can withstand, excessive welding current. 5.5. FINAL CHECK Check the following before use, check the flow direction of the product. The drawing on the right shows the recommended installation position. The solids are trapped inside the strainer screen and remain in its interior when it is removed. 11.103.32.0004 11.103.32.0003 5.6. WELDING Any welding work may only be carried out by qualified personnel that has been suitably trained and equipped with the necessary means to carry out this work. Disassemble the filter before starting the welding work. Disassemble the filter as indicate in the chapter 8. Maintenance. Weld the filter body to the pipework. INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 9

Start-up 6. Start-up Before operating the filter, the persons responsible should be duly informed about the operation of the filter and the safety instructions to be followed. This instruction manual should be available to personnel at all times. The following should be taken into consideration before using the filter: check that the pipeline and the filter are completely free from any traces of welding or other foreign matter. Proceed to clean the system if required, check for possible leaks and check that all the lines and connections are watertight and free from leaks, open the circuit. Visually check that no leaks are present in the sealed area. Do not modify the operating parameters for which the filter has been designed without prior written authorisation from INOXPA. Burn hazard! Do not touch the filter or pipes when hot liquids are circulating or when cleaning and/or sterilisation procedures are being carried out. 10 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Troubleshooting 7. Troubleshooting The attached table lists solutions to problems that may arise while operating the filter. It is assumed that the filter has been properly installed and that is has been selected correctly for the specific application. Contact INOXPA if technical assistance is required. External product leak No product is flowing through the pipeline Excessive sediments pass through the filter PROBABLE CAUSES The clamp seal is worn or deteriorated SOLUTIONS Replace the clamp seal Replace the seal material The sealing clamp is not sufficiently tight Tighten the sealing clamp The strainer screen is blocked Remove and clean the strainer screen The pipe is blocked Unblock the pipe The strainer screen is defective or damaged Replace the strainer screen If the problems persist stop using the filter immediately. Contact the filter manufacturer or the representative. INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 11

Maintenance 8. Maintenance 8.1. GENERAL CONSIDERATIONS This filter, just like any other machine, requires maintenance. The instructions contained in this manual cover the identification and replacement of spare parts. The instructions are aimed at maintenance personnel and those responsible for the supply of spare parts. Carefully read the chapter 9. Technical Specifications. Maintenance work can only be carried out by qualified personnel that are trained and equipped with the necessary resources to carrying out this work. All parts or Materials that are replaced must be properly disposed of/recycled in accordance with the current directives applicable in each area. 8.2. MAINTENANCE The following is recommended for correct maintenance: regular inspection of the filter and its components, keep a record of the operation of each filter, nothing any incidents, always have spare seals in stock. During maintenance, pay particular attention to the danger warnings indicated in this manual. The filter and pipes should never be pressurised during maintenance. The filter should never be hot during maintenance. Burn hazard! 8.2.1. Maintenance of the seals Preventive maintenance Maintenance after a leak Scheduled maintenance Replace after twelve months Replace at the end of the process Check for the absence of leaks on a regular basis Keep a record of the filter Use statistics to plan inspections The time interval between each preventive maintenance operation may vary according to the working conditions to which the filter is subjected: temperature, pressure, particle diameter, type of cleaning solutions used, etc. 8.2.2. Storage The filters should be stored in a closed area, under the following conditions: temperature: 15ºC to 30ºC air humidity: <60% Open-air storage of the equipment is not permitted. 8.2.3. Spare parts To request spare parts, it is necessary to indicate the type of filter, the position and the description of the part which can be found in the chapter 9. Technical Specifications. 12 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Maintenance 8.3. CLEANING The use of aggressive cleaning products such as caustic soda and nitric acid may burn the skin. Use rubber gloves during the cleaning process. Always use protective goggles. Loosen and remove the sealing clamp, check the seal. Remove the filter by pulling from its handle, check the internal O-ring seal. Clean the filter outside of its housing, do not allow any particles or deposits adhering to the strainer to dry out because its subsequent cleaning would be very difficult. See chapter 8.4 Disassembly and Assembly of the filter. Insert the assembly into its housing. 8.3.1. CIP (clean-in-place) cleaning Cleaning solutions for CIP processes Only use clear water (chlorine-free) to mix with the cleaning agents: a) Alkaline solution: 1% by weight of caustic soda (NaOH) a 70ºC (150ºF) 1 Kg NaOH + 100 l H 2 O = cleaning solution o 2,2 l NaOH al 33% + 100 l H 2 O = cleaning solution b) Acid solution: 0,5% by weight of nitric acid (HNO 3 ) a 70ºC (150ºF) 0,7 l HNO 3 al 53% + 100 l H 2 O = cleaning solution Check the concentration of the cleaning solutions; incorrect concentrations may lead to the deterioration of the filter seals. Before beginning with the disassembly and assembly tasks, clean both the interior and exterior of the filter. To remove any remains of cleaning products, ALWAYS perform a final rinse with clean water upon completion of the cleaning process. 8.3.2. Automatic SIP (sterilization-in-place) Sterilization with steam is applied to all equipment including pigging. The parts/materials will not be damaged if the indications specified in this manual are observed. No cold fluid can enter the equipment until the temperature of the equipment is lower than 60ºC (140ºF). Maximum conditions during the SIP process with steam or overheated water: a) Maxim temperature: 140ºC / 284ºF b) Maximum time: 30 min c) Cooling: sterile air or inert gas d) Materials: EPDM / FPM / NBR INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 13

Maintenance 8.4. DISASSEMBLY AND ASSEMBLY OF THE FILTER Assembly and disassembly of the filter must only be carried out by qualified personnel. 8.4.1. Disassembly of the filter Depressurise and drain the pipelines in the circuit. Remove the sealing clamp (34) from the filter. Remove the filter cover (12) of the filter body (01). Pull out the strainer screen (29) from the filter body (01). Remove and check the clamp seal (61) and the O-ring (20). 8.4.2. Assembly of the filter Place the O-rings (20) on the strainer screen (29). Insert the assembly in the filter body (01). Place the clamp seal (61) on the filter body (01). Tighten the sealing clamp (34) joining the strainer screen (29) and the filter body (01). 11.103.32.0008 14 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Technical Specifications 9. Technical Specifications 9.1. MATERIALS Parts in contact with the product AISI 316L Other steel parts AISI 304 Retainer EPDM (standard) NBR FPM Type of connections Welding (standard), DIN 11851, FIL-IDF, BS-RJT, Clamp, flanges, Macon Internal Surface finish Ra 0,8 μm External Surface finish Mirror polished 9.2. OTHER FEATURES Maximum working pressure Maximum working temperature 10 bar 121ºC (250ºF) standard EPDM seals (other seal materials supplied for higher temperatures) STRAINER SCREEN: WEDGE WIRE Eq. mesh C mm Useful surf. (%) 40 0,40 28 60 0,30 23 80 0,20 17 165 0,10 10 325 0,05 5 11.106.32.0010 STRAINER SCREEN: PERFORATED PLATE A (mm) Useful surf. (%) 0,5 15 1 28 2 30 5 46 10 x 1 20 11.106.32.0011 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 15

Technical Specifications 9.3. DIMENSIONS AND WEIGHTS 11.103.32.0006 WELD / WELD DIN DN d1(øid) d8 A1 B1 L1 kg 25 26 76,2 90 300 399 2,8 32 32 76,2 95 300 399 2,8 40 38 101,6 100 370 486 4,1 50 50 101,6 110 370 486 4,1 65 66 114,3 120 525 663 6,9 80 81 114,3 145 525 663 6,9 100 100 154,0 155 676 823 13,3 125 125 219,1 175 912 1089 19,0 150 150 219,1 175 912 1089 20,0 WELD / WELD OD DN d1(øid) d8 A1 B1 L1 kg 1 22,1 76,2 76 300 399 2,8 1 ½ 34,8 101,6 95 370 486 4,1 2 47,5 101,6 121 370 486 4,1 2 ½ 60,2 114,3 140 525 663 6,9 3 72,9 114,3 159 525 663 6,9 4 97,4 154,0 203 676 823 13,3 6 146,8 219,1 220 920 1097 25,1 16 INOXPA S.A.U. 11.103.30.02EN (0) 2019/02

Technical Specifications 9.4. EXPLODED DRAWING AND PARTS LIST 11.106.32.0009 Position Description Quantity Material 01 Filter body 1 AISI 316L 12 Filter cover 1 AISI 316L 20 O-ring 2 EPDM 29 Strainer screen 1 AISI 316L 34 Sealing clamp 1 AISI 304 61 Clamp seal 1 EPDM INOXPA S.A.U. 11.103.30.02EN (0) 2019/02 17

NOTES

NOTES

11.103.30.02EN (0) 2019/02 How to contact INOXPA S.A.U.: Contact details for all countries are continually updated on our website. Please visit www.inoxpa.com to access the information INOXPA S.A.U. Telers, 60 17820 Banyoles Spain Tel. : +34 972 575 200 Fax. : +34 972 575 502