Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Similar documents
Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Type 3271 Pneumatic Actuator. Actuator area: cm². Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Series 250 Pneumatic Control Valves Type and

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175 and 750 cm². Type 3271 Type Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

Type 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Series 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Mounting and Operating Instructions

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

Valve Series V2001 Three-way Valve Type 3323

T EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Mounting and Operating Instructions EB 8052 EN. Type 3251 Valve

Series 240 Type 3351 Pneumatic On/off Valve

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Mounting and Operating Instructions EB 8256 EN. Type 3286 Steam Conditioning Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Pressure Reducing Valve Type 2114/2415

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Series 240 Pneumatic On-off Valve Type 3351

Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator

Series 240 Types PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve

Mounting and Operating Instructions EB 8252 EN. Type 3281 Steam Conditioning Valve

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Series 240 Pneumatic Control Valve Type and Type Three-way Valve Type 3244

Application Pressure reducing valves for the food and pharmaceutical industries

Pneumatic Control Valve Type and Type Micro-flow Valve Type 3510

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Mounting and operating instructions EB 8220 EN. Pneumatic Butterfly Valve Type 3335/AT and Type 3335/3278. Fig. 2 Type 3335/AT

Data Sheet T EN

Series 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel

Declaration of Conformity as per Directive 97/23/EC

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Series 2371 Pressure Regulators Excess pressure valves for the food and pharmaceutical industries

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

ANSI version. The valve closes when the differential pressure rises

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252

Pneumatic Rotary Actuator Type 3278

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

Pneumatic Butterfly Valve Type 3335 / AT

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Pneumatic Control Valve Assembly Type 3331/3278

Series 240 and 250 Valves with perforated plug

Operating & Maintenance Manual For Steam Conditioning Valve

Maxifluss Rotary Plug Valves VETEC Types 72.3/R and 72.4/R

Globe Control Valve Series 1a

Series 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a

T 8321 EN Type 3278 Pneumatic Rotary Actuator

Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244

Transcription:

Type 3249-1 and Type 3249-7 Pneumatic Control Valves Type 3249 Aseptic Angle Valve Ball body version Special version with packing Type 3249-7 Control Valve with Type 3277 Actuator and integrated positioner Mounting and Operating Instructions EB 8048 EN Edition November 2016

Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious injury WARNING! Hazardous situations which, if not avoided, could result in death or serious injury Property damage message or malfunction Note: Additional information Tip: Recommended action 2 EB 8048 EN

Contents 1 General safety instructions...4 2 Process medium and scope of application...5 2.1 Transportation and storage...5 3 Design and principle of operation...5 4 Connection between valve and actuator...8 4.1 Assembly and adjustment...8 4.2 Option of preloading springs for fail-safe action "actuator stem extends"...9 5 Installation...9 5.1 Signal pressure line...10 6 Operation...10 6.1 Start-up...10 7 Maintenance...10 7.1 Replacing sealing parts and plug...11 8 Nameplates...13 9 Customer service...14 Note: Refer to the Data Sheet u T 8048 for the technical data as well as dimensions and weights for the Type 3249-1 and Type 3249-7. For further product documentation go to the website of SAMSON AG. EB 8048 EN 3

General safety instructions 1 General safety instructions The control valve must be mounted, started up or serviced by fully trained and qualified personnel only; the accepted industry codes and practices are to be observed. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings given in these mounting and operating instructions, particularly those concerning installation, start-up and maintenance, must be strictly observed. According to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible dangers due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards. The control valves comply with the requirements of the European Pressure Equipment Directive 2014/68/EU. Valves with a CE marking have a declaration of conformity which includes information about the applied conformity assessment procedure. The declaration of conformity is available at u www.samson.de. To ensure appropriate use, only use the device in applications where the operating pressure and temperatures do not exceed the specifications used for sizing the regulator at the ordering stage. The manufacturer does not assume any responsibility for damage caused by external forces or any other external factors. Any hazards that could be caused in the valve by the process medium, operating pressure or by moving parts are to be prevented by taking appropriate precautions. Proper transport, storage, installation, operation and maintenance are assumed. Note: Non-electric actuators and control valve versions do not have their own potential ignition source according to the ignition risk assessment stipulated in EN 13463-1: 2009, section 5.2, even in the rare incident of an operating fault. Therefore, they do not fall within the scope of Directive 2014/34/EU. For connection to the equipotential bonding system, observe the requirements specified in section 6.4 of EN 60079-14 (VDE 0165 Part 1). 4 EB 8048 EN

Process medium and scope of application 2 Process medium and scope of application Control valve for aseptic applications in the food and pharmaceutical industries according to DIN or ANSI standards. Nominal sizes DN 15 to 100 NPS ½ to 4 Maximum pressure 10 bar 150 psi Temperature range 0 to 160 C 32 to 320 F 2.1 Transportation and storage The valve must be carefully handled, transported and stored. Protect the valve against adverse influences, such as dirt, moisture or frost, during storage and transportation. When valves are too heavy to be lifted by hand, fasten the lifting sling at a suitable place on the valve or valve bonnet. Do not attach any lifting equipment, slings or supports to mounting parts, such as actuator, positioner or pressure lines. 3 Design and principle of operation See Fig. 1 on page 7. The Type 3249 Angle Valve can be combined with either a Type 3271 Pneumatic Actuator or a Type 3277 Pneumatic Actuator with integral positioner attachment. Standard version Angle valve in ball body design, with clamp connection of the bonnet without packing. The stem is sealed by an EPDM diaphragm with PTFE facing. Special version Angle valve with screwed-on valve bonnet and additional V-ring packing EB 8048 EN 5

Design and principle of operation The standard valve body is equipped with welding ends for welding into pipelines. Special versions are equipped with threaded or flanged ends, or clamp connections. The valve body is designed without cavities, allowing it to be cleaned or sterilized prior to the production process according to the CIP (clean-in-place) or SIP (sterilization-inplace) method. A test connection (4.4) on the special version with packing (4.2) enables pressure monitoring. The medium flows through the valve in the direction indicated by the arrow. The plug (3) is moved by changing the signal pressure applied to the diaphragm of the actuator. The plug stem (6) is connected to the actuator stem (8.1) by the stem connector. The plug stem is sealed by the diaphragm (6.3), and in the special version additionally by the backup packing. Fail-safe action Depending on how the compression springs (8.3) are arranged in the actuator, the valve has two different fail-safe positions: Actuator stem extends When the signal pressure is reduced or the air supply fails, the springs move the actuator stem downwards and close the valve. The valve opens when the signal pressure is increased enough to overcome the force exerted by the springs. Actuator stem retracts When the signal pressure is reduced or the air supply fails, the springs move the actuator stem upwards and open the valve. The valve closes when the signal pressure is increased enough to overcome the force exerted by the springs. Legend for Fig. 1: 1 Valve body 3 Plug 4.1 Spring 4.2 Packing 4.3 Washer 4.4 Test connection 5 Valve bonnet 5.1 Guide bushing 5.2 Threaded bushing 5.3 Yoke 5.4 Screws 5.5 Travel indicator scale 5.6 Washer 6 Plug stem 6.1 Stem connector nut 6.2 Lock nut 6.3 Diaphragm 6.4 Grub screw 7 Stem connector 8 Actuator 8.1 Actuator stem 8.2 Ring nut 8.3 Compression spring 8.4 Rolling diaphragm 9 Signal pressure connection 10 Vent screw 6 EB 8048 EN

Design and principle of operation Valve with Type 3271 Actuator (120 cm²) Special version with backup packing 10 Valve with Type 3271 Actuator 10 8 8 7 6.1 6.2 6 4.1 4.4 9 8.4 8.3 8.2 8.1 5.5 5.3 5.2 4.2 4.3 5.1 5.4 5 8.1 5.5 6.2 4.4 8.2 7 6.1 6.2 6 5 5.6 6.3 1 8.3 8.4 9 6.3 3 3 1 Type 3277 Actuator 8 8.1 9 5 8.2 6.4 Fig. 1: Functional diagram EB 8048 EN 7

Connection between valve and actuator 4 Connection between valve and actuator The basic pneumatic actuator can be replaced by a pneumatic actuator with additional handwheel or by an electric actuator. The standard pneumatic actuator can be replaced by a smaller or larger actuator for all nominal valve sizes. If the travel range of the actuator is larger than the travel of the valve, the springs in the actuator are preloaded by the manufacturer so that the travel ranges match. 4.1 Assembly and adjustment See Fig. 1 on page 7. Proceed as follows if the valve and actuator have not been assembled by the manufacturer or if the actuator is to be replaced by an actuator of another type or size: On tightening or undoing the lock nut (6.2), a wrench must be used to hold the stem connector nut (6.1) stationary. Otherwise the plug stem may rotate and destroy the diaphragm. 1. Unscrew the lock nut (6.2) and stem connector nut (6.1) on the valve. Firmly press the plug together with the plug stem into the seat. Thread down the lock nut and stem connector nut. 2. Remove the clamps of the stem connector (7) and ring nut (8.2) from the actuator. Slide the ring nut over the plug stem. 3. Place the actuator onto the valve bonnet (5) and secure it with the ring nut (8.2). 4. Read the bench range (e.g. 0.2 to 1 bar or 0.6 to 1 bar) and the actuator's failsafe action (e.g. actuator stem extends) from the actuator's nameplate. The fail-safe action "actuator stem extends" or "actuator stem retracts" is marked by FA or FE on the Type 3271 Actuator, and by a corresponding symbol on the nameplate of the Type 3277 Actuator. The lower value corresponds to the lower bench range value to be adjusted, whereas the upper value corresponds the upper bench range value. 5. For actuators with fail-safe action "actuator stem extends", apply a signal pressure that corresponds to the lower bench range value (e.g. 0.2 or 0.6 bar) to the connection on the bottom diaphragm chamber. For actuators with fail-safe action "actuator stem retracts", apply a signal pressure that corresponds to the upper bench range value (e.g. 1 bar) to the top diaphragm chamber connection. 6. Screw on the stem connector nut (6.1) by hand until it touches the actuator stem (8.1). Then turn it a further ¼ turn and secure this position with the lock nut. 7. Position clamps of the stem connector (7) and screw them tight. Align travel indicator scale (5.3) with the tip of the stem connector; for actuators with fail-safe ac- 8 EB 8048 EN

Connection between valve and actuator tion "actuator stem extends" align it with lower marking (valve closed) and for actuators with fail-safe action "actuator stem retracts" align it with top marking (valve open). Note: When removing an actuator with fail-safe action "actuator stem extends" and especially an actuator with preloaded springs, apply a signal pressure that is slightly higher than the lower bench range value (see actuator nameplate) to the bottom loading pressure connection so that the ring nut (8.2) can be unscrewed. 4.2 Option of preloading springs for fail-safe action "actuator stem extends" To achieve a greater positioning force, the springs of the actuators can be preloaded by up to 12.5 % of their travel or bench range (with 350 cm² up to 25 % of their travel or bench range). When a preload of, e.g. 0.1 bar, is desired for a bench range of 0.2 to 1 bar, the lower bench range value is shifted by 0.1 bar to 0.3 bar (0.1 bar correspond to a preload of 12.5 %). When adjusting the valve, the lower bench range value must now be set to 0.3 bar. The new bench range of 0.3 to 1.1 bar must be marked on the nameplate as bench range with pretensioned springs. Note: The springs have already been pretensioned by 50 % for valves in nominal sizes DN 15 to 25 with 7.5 mm travel, 0.6 to 1 bar bench range and fail-safe action "actuator stem extends. Actuators that have already been preloaded by the manufacturer without mounting the valve are labeled correspondingly. Additionally, they can be identified by three longer bolts with nuts protruding from the bottom diaphragm case. Before starting any work on the valve, relieve the compression from the preloaded springs by unthreading the nuts on the long bolts a few turns, alternating between them to gradually release the tension. EB 8048 EN 9

Installation 5 Installation See Fig. 1 on page 7. Install the control valve with the actuator in the upright position. In valve versions with welding ends, the entire bonnet assembly must be removed from the valve body after undoing the clamp (5.4) to allow it to be welded into the pipeline. 6 Operation See Fig. 1 on page 7. To reverse the fail-safe action of the pneumatic actuator, refer to the Mounting and Operating Instructions of the actuator: EB 8310-... EN for Type 3271 and EB 8311 EN for Type 3277 Flush and clean the pipeline thoroughly before installing the valve. Make sure the valve is installed free of stress. If necessary, support the pipelines near the connections. Do not attach supports directly to the valve or actuator. 5.1 Signal pressure line Connect the signal pressure line for valves with actuator with fail-safe action "actuator stem extends" to the connection on the bottom diaphragm case, and for valves with actuator with fail-safe action "actuator stem retracts" actuator to the connection on the top diaphragm case. In the Type 3277 Actuator, the bottom signal pressure connection is located at the side of the yoke under the bottom diaphragm case. 10 EB 8048 EN

Maintenance 6.1 Start-up First start up the control valve after mounting all the parts. Avoid surges in signal pressure as they may damage the rolling diaphragm. As a general rule: open and close shut-off valves slowly. Open the shut-off valves first on the upstream pressure side. Afterwards, open all the valves on the consumer side (downstream of the valve). Note: Replace the test connection (screw, 4.4) with a pressure sensor to monitor the diaphragm (6.3) for leaks. 7 Maintenance See Fig. 1 on page 7. The control valve is subject to normal wear, especially at the seat and plug. Depending on the operating conditions, check the valve at regular intervals to prevent possible failure before it can occur. If leakage occurs, this could be caused by a damaged diaphragm (6.3) or the PTFE V- ring packing (4.2) may be defective in the special version. If the valve does not close tightly, tight shutoff may be impaired by dirt stuck between the seat and plug or by damaged facings. We recommend removing the parts, cleaning them, and, if necessary, replacing them with new ones. Before starting any work on the valve body, disconnect the signal pressure and remove the signal pressure line as well as the actuator. Make sure that none of the process medium is in the pipeline. When used at high temperatures, allow the plant section to cool down to ambient temperature. Actuators with preloaded springs are labeled correspondingly and can also be identified by three long bolts protruding from the bottom of the actuator. Special care is needed in this case. Before starting any work on the valve, relieve the compression from the preloaded springs by unthreading the nuts on the long bolts a few turns, alternating between them to gradually release the tension. 7.1 Replacing sealing parts and plug Before starting any work on the valve body, first remove the actuator. EB 8048 EN 11

Maintenance Note: In older versions delivered before August 2008, the plug is stuck with adhesive. To replace the plug, follow the instructions written in the January 2005 edition of EB 8048. 1. Apply a signal pressure that is higher than the lower bench range value (see nameplate) to the actuator. 2. Remove the stem connector clamps (7) between the actuator stem and the plug stem and unscrew the ring nut (8.2). 3. Lift the actuator off the valve. 4. Remove nuts (6.1 and 6.2). 5. Take off the clamp (5.6) or unscrew the screws (5.4) on the valve bonnet in the special version with packing. Carefully remove the valve bonnet (5) together with plug (3) and diaphragm (6.3). In the special version with packing, also unscrew the threaded bushing (5.2). 6. Pull plug stem (6) together with plug (3) and diaphragm (6.3) out of the valve bonnet. Remove the stopper (4.4) in the special version. Unscrew threaded bushing (5.2), remove packing rings (4.2), washer (4.3) and spring (4.1). Carefully clean the packing chamber. 7. Unscrew grub screw (6.4) on the plug. Clamp the plug into a vice using plastic jaws (SAMSON order no. 1281-0053). Unscrew the plug stem. 8. Remove the damaged diaphragm. 9. Remove the plug and insert a new diaphragm. To prevent seizure, apply lubricant (order no. 1400-6991) to the threads of the plug stem and plug. 10. To prevent any damage, place the plug in a suitable clamping fixture and tighten the plug stem using the two locking nuts at the end of the plug stem. Observe the following tightening torques: Nominal size DN 15 to 25 NPS ½ to 1 DN 32 to 100 NPS 1¼ to 4 Tightening torque 10 Nm 70 Nm 11. Secure plug with grub screw. In DN 15 to 25, check the concentricity of the plug to the plug stem. It must not be more than 0.04 mm at the maximum. 12. Slide the plug stem with assembled plug into the valve bonnet. In the special version with packing, slide the spring (4.1), washer (4.3) and new packing rings over the plug stem into the packing chamber. Insert the threaded bushing (5.2) and tighten it as far as it will go. 13. Apply the lubricant suitable for foodstuffs (order no. 8150-9002) to the clamp (5.6) and the flanges of the valve bonnet and valve body. Carefully place the valve bonnet on the valve body. 12 EB 8048 EN

Maintenance 14. Place the clamp in position and tighten the clamp screw. Hit the clamp lightly with a plastic hammer and tighten the clamp screw again. Repeat this procedure several times to tighten the clamp as far as it will go. 15. Thread the lock nut (6.2) and nut (6.1) loosely onto the plug stem (6). 16. Mount the actuator and adjust the upper and lower bench range values as described in section 4.1 on page 8. EB 8048 EN 13

Nameplates 8 Nameplates SAMSON 3271 Var-ID 1 2 3 4 5 6 7 Serial no. 1234 Made in Germany Manufacturer and type number Configuration ID (Var.-ID) as bar code and plain text Serial number Country of origin Diaphragm area (350 in this case) cm² Diaphragm material: NBR, EPDM or PVMQ Symbol indicating fail-safe action: stem extends or retracts (stem extends in this example) Bench range in bar or psi 350 cm² 1.5... 2.7 bar NBR- 22... 39 psi 15 mm 2.0... 2.7 bar 29... 39 psi G pmax 6 bar / 90psi Symbol for operating travel in mm Bench range with preloaded springs Thread for pneumatic connection in G, NPT or Rc Permissible supply pressure p max in bar or psi Fig. 2: Nameplate for Type 3271/3277 Actuator SAMSON 3249 1 DN 2 3 p max 20 C T max K V 4 5 6 7 Serial no. Var-ID 8 9 1 Modification index 2 Valve size: DIN: DN, ANSI: Size 3 Body material 10 Made in France 2013 11 Perm. operating gauge pressure at 4 20 C DIN: bar, ANSI: psi 5 Max. operating temperature Flow coefficient and characteristic 6 % = equal percentage, L = linear Seat/plug seal: ME = metal 7 PK = soft PEEK seal PT = soft PTFE seal 8 Serial number 9 Configuration ID Compliance with food industry 10 requirements 11 Year of manufacture Fig. 3: Nameplate for Type 3249 Valve 14 EB 8048 EN

Customer service 9 Customer service If malfunctions or defects occur, contact the SAMSON After-sales Service Department for support. The addresses of SAMSON AG, its subsidiaries, representatives and service facilities worldwide can be found on the SAMSON website, in all SAMSON product catalogs or on the back of these Mounting and Operating Instructions. Please send your inquiries to: service@samson.de To assist diagnosis and in case of an unclear mounting situation, specify the following details (see section 8 on page 14): Type designation (valve, actuator) and nominal size of the valve Serial number and configuration ID (Var- ID) Upstream and downstream pressure Process medium and its temperature Is a strainer installed? Installation drawing showing the exact location of the valve and all the additionally installed components (shut-off valves, pressure gauge, etc.) Bench range of the actuator (e.g. 0.2 to 1 bar) Nameplates are attached to the valve and the actuator. EB 8048 EN 15

SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 samson@samson.de www.samson.de EB 8048 EN 2017-05-18 English