NEW: CG132B TAKE ADVANTAGE OF DIGITAL ASSISTANCE

Similar documents
CAT CG170. Series Gas Generator Sets

CAT CG170 K. Series Gas Generator Sets

MWM DIGITALPOWER TCG Robust. Efficient. Digital.

MWM DIGITALPOWER TCG Robust. Efficient. Digital.

Top marks for ecology and economy.

4,5 MW el. Efficiency on a new level. TCG 2032 TCG 2032B V16. 44,6 % electrical. 43,2 % thermal.

CAT G3500. Series Gas Generator Sets

Press Release. For Worldwide Release: July 2, 2012 Release Number: EEPR1212. Caterpillar Introduces New Line of Gas Generator Sets

POWERFUL LINEUP. Paralleling Generator Sets

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in)

Energy. Efficiency. Environment.

Medium Speed Generator Sets Products and Applications

SHOULDER TO SHOULDER. The case for paralleling generator sets

INTEGRATED POWER SYSTEMS FOR MANUFACTURING AND INDUSTRIAL FACILITIES

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Cat C Diesel Generator Sets

DIESEL GENERATOR SET FEATURES

Power Rating Minimum Power 746 bkw 1000 bhp Maximum Power 895 bkw 1200 bhp. Emission Standards U.S. EPA Tier 4 Final

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

Cat C Diesel Generator Sets

SUITABLE FOR ANY SCENARIO ZEPPELIN DRIVE TRAINS.

New D98 Diesel Engine Series. Empower your Business

Cat 3512B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

POWER YOUR TELECOM SITE WITH CAT HYBRID POWER FOR TELECOM APPLICATIONS

THE POWER YOU LIVE BY. Caterpillar Marine Generator Sets

built for the next generation

HIGH SPEED POWER STATIONS

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Securing A Sustainable Future.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Cat 3512B Diesel Generator Sets

Cat 3512 Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Caterpillar experience in approaching the emerging Renewable Energy Market in Russia

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

built for the next generation Cat

Cat 3512B Diesel Generator Sets

NATURAL GAS CONTINUOUS

400 to 11,000 Volts. Standby, Prime, Continuous

MAN 18V48/60TS. Two-stage turbocharged diesel engine

Draglines. Product Line

Power. Gas engines for CHP units and gensets.

Cat 3512 Diesel Generator Sets

Voltage 220 to or 1800 RPM

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

3406 C Industrial Engine Non-Certified 298 bkw/ rpm

3406 C Industrial Engine Non-Certified 328 bkw/ rpm

Power Rating Minimum Power 36.4 bkw 48.8 bhp Maximum Power 50 bkw 67.1 bhp. Emission Standards U.S. EPA Tier 4 Final, EU Stage IIIB

SUITABLE FOR ANY SCENARIO ZEPPELIN DRIVE TRAINS.

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Power Rating Minimum Power 218 bkw 292 bhp Maximum Power 359 bkw 482 bhp mm (5.4 in) mm (6.5 in)

one giant leap for electric power. The 2-4MW family of diesel generator sets powered by the C175

3412C Generator Set Electric Power. Specifications. Benefits and Features

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

Medium speed generator sets Products and applications

Cat 3412 Diesel Generator Sets

Cat C32 Diesel Generator Sets

3508 B Industrial Engine

Cat C32 Diesel Generator Sets

Generator Set Specifications 100 ekw (125 kva)

REMANUFACTURED PRODUCTS. Cat Reman Products for Engines

Power Rating Minimum Power 250 bkw 335 BHP Maximum Power 340 bkw 456 BHP

3516 B Industrial Engine

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Bore 145 mm 5.71 in Stroke 162 mm 6.38 in Displacement 32.1 L in 3 Twin Turbocharged-Aftercooled (TTA) Compression Ratio 15.0:1 67.

SUITABLE FOR ANY SCENARIO ZEPPELIN DRIVE TRAINS.

Cat C32 Diesel Generator Sets

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

NATURAL GAS STANDBY. Gas Generator Set. 500 ekw 750 kva 60 HZ 1800 RPM FEATURES

Power Rating Minimum Power 1506 bkw 2100 bhp Maximum Power 1506 bkw 2100 bhp

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

Specifications. 3406C Generator Set Electric Power

Continuous, Prime, Standby, Mission Critical

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

Power Rating Minimum Rating 429 bkw 575 bhp Maximum Rating 470 bkw 630 bhp Rated Speed

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 60 ekw (75 kva)

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Power Rating Minimum Power 761 bkw 1020 bhp Maximum Power 1119 bkw 1500 bhp mm (68 in) 190 mm (7.5 in)

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 480 ekw 600 KVA

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

MTU ONSITE ENERGY DIESEL GENERATOR SETS 50 Hz: 30-3,730 kva 60 Hz: 30-3,250 kwe

Power Rating Minimum Power 429 bkw 575 bhp Maximum Power 597 bkw 800 bhp. 145 mm (5.71 in) 183 mm (7.2 in)

Microgrid solutions Delivering resilient power anywhere at any time

FREQUENTLY ASKED QUESTIONS TIER 4 INTERIM / STAGE IIIB PRODUCTS

C32 ACERT Generator Set Electric Power

3406 C Industrial Engine Non-Certified 362 bkw/ rpm

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

3512 Industrial Engine

Transcription:

NEW: CG132B TAKE ADVANTAGE OF DIGITAL ASSISTANCE 2018 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, BUILT FOR IT, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

Installed capacity of 6,981 MW el worldwide* CAT GAS POWER SMARTER 2,020 units 1,582 units 2,942 MW 1,735 MW el el ENERGY SOLUTIONS 420 units 481 MW el 1,453 units 1,823 MW el *Installed gas gensets within the last 10 years COMMERCIAL AND INDUSTRIAL FACILITIES Facilities such as manufacturing plants, resorts, shopping centers, office or residential buildings, universities, data centers and hospitals reduce operating costs and carbon footprint simultaneously. They benefit from a state-of-the-art technology that provides various forms of process energy such as electricity, heat, steam and cooling with e.g. absorption chiller. ELECTRIC UTILITIES Caterpillar has led innovation to deliver stationary and containerized gas power plants to electric utilities and district energy facilities around the world for both continuous grid support and peak electricity demand. MINES Mining operators increase mine safety and reduce carbon emissions with coal gas, while many other mining operations are realizing the benefits of onsite gas power generation to support greenfield site development. AGRICULTURE AND FOOD / BEVERAGE PROCESSING Biogas, a useful byproduct of the anaerobic digestion of organic waste, is created by food processors, ethanol and biodiesel manufacturers, and farms around the world as a renewable fuel resource for Cat powered electricity generation. LANDFILLS AND WASTEWATER TREATMENT PLANTS Landfill and sewage gases are generated by communities around the world as part of sanitary process infrastructure. Instead of destroying or flaring the methane gas produced, communities make beneficial use of this fuel as part of a sustainable energy program. GREENHOUSES In greenhouses, Cat gas generator sets simultaneously deliver electricity for lighting or sale to the local grid, hot water for facility heating and carbon dioxide as an organic fertilizer for increased crop production. MEETING YOUR NEEDS HAS SHAPED OUR HISTORY At Caterpillar, we understand what it takes to deliver a successful gas power generation system, and it starts with a core machine that is designed for efficiency and reliability. Since the 1920s, Caterpillar has been designing and building engines for power production. Although the technology has changed over the years, the philosophy hasn t: to deliver the most reliable power generation at the lowest possible cost of ownership and operation. Today, Caterpillar not only manufactures power generation equipment, but we also provide customized project financing via Cat Financial. THE COMPLETE SOLUTION Caterpillar is your complete gas solutions partner. From mechanical systems such as gas fuel train and heat recovery systems, to exhaust aftertreatment that complies with the world s most stringent emission requirements, Caterpillar Gas Solutions engineering works with your local Cat dealer to deliver a complete scope of supply. Caterpillar also provides electrical systems such as master controls and paralleling switchgear, electrical distribution switchgear and uninterruptible power supply (UPS that can meet either UL or IEC requirements. PRODUCT SUPPORT WORLDWIDE Your gas power system is supported by our factory trained global network of Cat dealers. Therefore, you can rest assured that your equipment will be ordered, delivered, installed and commissioned in consultation with a local expert. You ll also have the confidence that Caterpillar will be there to keep you up and running. Cat dealers have over 1,600 dealer branch stores operating in 200 countries to provide the most extensive post-sales support including oil and fuel monitoring services, preventive maintenance and comprehensive Customer Support Agreements. LOWER LIFE CYCLE COST With longer maintenance intervals, higher fuel efficiency and competitive repair options, Caterpillar delivers the lowest total owning and operating costs. When you design your facility within Caterpillar's Application and Installation Guidelines, you can expect highest generator set availability. It all adds up to a strong return on your investment, year after year.

CG132B NEW ON THE BLOCK. ROBUST. EFFICIENT. DIGITAL. The CG132B is the first of a new generation: State-of-the-art components and the TPEM (Total Plant & Energy Management control system ensure maximum reliability and availability.the improved oil management and optimized cylinder and turbo chargers set new standards in terms of durability and reliability. MAXIMUM EFFICIENCY Best total cost of ownership in its power range through unique combination of a long operating period until the major overhaul (80,000 oh for natural gas and outstanding efficiency (electrical efficiency of up to 43.5 percent. LOWER GAS CONSUMPTION through improved efficiency and fuel flexibility REDUCED MAINTENANCE COSTS through longer service intervals and longer operating hours until the major overhaul LOWER LUBE OIL CONSUMPTION leads to lower operating costs IMPROVED DURABILITY ensures higher reliability and availability

BENEFITS THE NEXT LEVEL OF EFFICIENCY HIGHEST EFFICIENCY IN ITS POWER RANGE Electrical efficiency of up to 43.5 percent Low Total cost of Ownership through rock-bottom operating costs More efficiency through numerically optimized, low-loss flow design OPTIMIZED LUBE OIL MANAGEMENT Lowest-in-class lube oil consumption : 0.1 g/kwh el Longer oil change intervals Oil tank and integrated daily refill tank FLANGED GENSET CONCEPT Vibration-decoupled base frame for lower installation costs and reliable operation Greater integrated lube oil volume Integrated oil management IMPROVED TURBO CHARGER FOR A WIDE FIELD OF DEPLOYMENT Longer maintenance intervals Wider suction air temperature window HIGHER AVAILABILITY AND LONGER USEFUL LIFE Optimized combustion through evenly charged cylinders Optimized combustion with lower peak pressure Smoothly running, low-vibrating genset MAXIMUM RELIABILITY Improved island mode capability through optimized TPEM genset control Fulfills G1, G2 & G3 classes according to ISO 8528 with less than 10 steps in most applications TPEM THE NEW CONTROL SYSTEM Easy human-machine interface Fully integrated remote access Expanded scope, e.g. synchronization, power switch, and plant control

TPEM. PROFITABLE, EFFICIENT AND COMPLETE. With its comprehensive digital power plant control system TPEM (Total Plant & Energy Management, Caterpillar redefines the control standard for energy solutions. TPEM eliminates for many application the need for additional control systems, as all power plant data for the genset and plant control are combined in one system. The optimum power plant control enables high economic efficiency, provided from a single source. SET UP OPTIMIZE ONE USER INTERFACE Complete power plant control and setup Custom-tailored technical solutions One integrated, flexible control system for all electric power applications Multiple functionalities for individual solutions One user interface for complete power plant control and setup Data management and analysis delivers information for optimizing the power plant Life cycle history enables the logging of and access to data throughout the life cycle of the genset and the peripherals REMOTE ACCESS Remote power plant control on site and via VPN connection with the free visualization TPEM Remote Client SECURITY-ORIENTED TECHNOLOGY Meets latest ISO 27001 standards Safety chain for cogeneration plant monitoring (TÜV-certified DIGITAL ASSISTANCE Ready for Cat connect services OPERATE High efficiency through optimal power plant control Enables remote power plant management and monitoring Use the full genset potential with maximum reliability Expanded scope fully integrated remote access, synchronization, power switch and plant control

TECHNICAL DATA 50 Hz TECHNICAL DATA 60 Hz Bore / Stroke mm in 132/160 5.2 / 6.3 132/160 5.2 / 6.3 132/160 5.2 / 6.4 Displacement dm 3 cu in 17.5 1,067.9 26.3 1,604.9 35.0 2,135.8 Speed min -1 1,500 1,500 1,500 Mean piston speed m/s ft/s 8.0 26.2 8.0 26.2 8.0 26.2 Length 1 mm in 3,100 122 3,830 151 4,200 165 Width 1 mm in 1,780 70 1,780 70 1,780 70 Height 1 mm in 2,150 85 2,150 85 2,150 85 Dry weight genset kg lb 5,720 12,610 7,000 15,432 8,070 17,791 Bore / Stroke mm in 132/160 5.2 / 6.3 132/160 5.2 / 6.3 132/160 5.2 / 6.4 Displacement dm 3 cu in 17.5 1,067.9 26.3 1,604.9 35.0 2,135.8 Speed min -1 1,800 1,800 1,800 Mean piston speed m/s ft/s 9.6 31.5 9.6 31.5 9.6 31.5 Length 1 mm in 3,100 122 3,830 151 4,200 165 Width 1 mm in 1,780 70 1,780 70 1,780 70 Height 1 mm in 2,150 85 2,150 85 2,150 85 Dry weight genset kg lb 5,720 12,610 7,000 15,432 8,070 16,975 NATURAL GAS APPLICATIONS NATURAL GAS APPLICATIONS Mean effective pressure bar psi 18.9 274.1 18.9 274.1 18.8 272.7 Thermal output 4 kw MBTU/hr 404 1,379 618 2,110 821 2,803 Electrical efficiency 3 % % 43.1 43.1 43.3 43.3 43.5 43.5 Thermal efficiency 3 % % 43.6 43.6 44.6 44.6 44.6 44.6 Total efficiency 3 % % 86.7 86.7 87.9 87.9 88.1 88.1 Mean effective pressure bar psi 15.8 229.2 15.7 227.7 15.7 227.7 Thermal output 4 kw MBTU/hr 427 1,458 648 2,213 856 2,923 Electrical efficiency 3 % % 42.1 42.1 42.4 42.4 42.6 42.6 Thermal efficiency 3 % % 45.0 45 45.7 45.7 45.5 45.5 Total efficiency 3 % % 87.1 87.1 88.1 88.1 88.1 88.1 BIOGAS APPLICATIONS Minimum heating value Hu = 5,0 kwh/nm³ Minimum heating value Hu = 18 MJ/Nm³ or 457 Btu/scf. BIOGAS APPLICATIONS Minimum heating value Hu = 5,0 kwh/nm³ Minimum heating value Hu = 18 MJ/Nm³ or 457 Btu/scf. Sewage gas (65 % CH 4 / 35 % CO 2 Biogas (60 % CH 4 / 32 % CO 2 Landfill gas (50 % CH 4 / 27 % CO 2 Sewage gas (65 % CH 4 / 35 % CO 2 Biogas (60 % CH 4 / 32 % CO 2 Landfill gas (50 % CH 4 / 27 % CO 2 Mean effective pressure bar psi 18.9 274.1 18.9 274.1 18.8 272.7 Thermal output 4 kw MBTU/hr 394 1,345 599 2,045 791 2,701 Electrical efficiency 3 % % 42.8 42.8 42.9 42.9 43.1 43.1 Thermal efficiency 3 % % 42.2 42.2 42.8 42.8 42.6 42.6 Total efficiency 3 % % 85.0 85.0 85.7 85.7 85.7 85.7 Mean effective pressure bar psi 15.8 229.2 15.7 227.7 15.7 227.7 Thermal output 4 kw MBTU/hr 414 1,414 627 2,141 827 2,824 Electrical efficiency 3 % % 41.7 41.7 41.7 41.7 41.9 41.9 Thermal efficiency 3 % % 43.3 43.3 43.6 43.6 43.3 43.3 Total efficiency 3 % % 85.0 85.0 85.3 85.3 85.2 85.2 1 Transport dimensions for gensets, components set up seperately must be taken into consideration. 2 NO x 500 mg/nm³; 1g/bhp-h; exhaust gas dry at 5 % O 2. 3 According to ISO 3046-1 at U = 0,4 kv, cosphi = 1,0 for 50 Hz, a minimum methane number of MN 70 for natural gas and methan number 134 (sewage gas for biogas applications. 4 Exhaust gas cooled to 120 C (248 F for natural gas and 150 C (302 F for biogas. Data for special gases and dual gas operation on request. The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive. 1 Transport dimensions for gensets, components set up seperately must be taken into consideration. 2 NO x 500 mg/nm³; 1g/bhp-h; exhaust gas dry at 5 % O 2. 3 According to ISO 3046-1 at U = 0,48 kv, cosphi = 1,0 for 50 Hz, a minimum methane number of MN 70 for natural gas and methan number 134 (sewage gas for biogas applications. 4 Exhaust gas cooled to 120 C (248 F for natural gas and 150 C (302 F for biogas. Data for special gases and dual gas operation on request. The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive.

For more information and to contact your local Cat dealer, visit www.cat.com/catcg132b LEYE0020-00 2018 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, BUILT FOR IT, their respective logos, Caterpillar Yellow, the Power Edge trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.