G2 MAGNETIC RETROFIT KIT

Similar documents
MAGNETIC TROFFER RETROFIT KIT

ECO EXT (DIMMABLE)

TRUET5 EXT (DIMMABLE)

ROUND PENDANT LED HIGH BAY HP Gen. 2 SERIES

RTR Gen 3/ LED Troffer Conversion Kit

SIRIUS ON/OFF SU OF50SUS PRODUCT SPECIFICATION PRODUCT DESCRIPTION CERTIFICATIONS & QUALIFICATIONS E DIMENSIONS. Tolerance Range : ± 10%

4 Watt LED Bulb ENERGY BULBS MODELS: EST C pic 1. pic 2. pic 3. pic 4

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

security ase100 (4ft) series (2' available) SURFACE / corner / wall / ceiling mounted security led luminaire high impact angled security luminaire

ECO-T LED RECESSED TROFFER USER MANUAL

Cynergy Series Retrofit Kit

NULB-5 Pro90 Series ILLUMINATING THE FUTURE...SINCE Ultra-Low Profile Linear LED Lightbar PLUS. Type Project Catalog No.

ECO LIGHTING.

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

LED HIGH BAY LINEAR HL SERIES GEN 2

Technical Requirements Table, v1.7

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

LED Flat Panel Luminaires

Alloy LED: Delivering Continuous Innovation

LED Flat Panel Luminaires

Specification Sheet: EcoPark LED Parking Garage Fixture. Indoor/Outdoor

Energy Solutions LED Accelerator Program

LED Flat Panel Luminaires

LED Parking Garage Luminaire Improvements. June 2016

WALL MOUNT - DIRECT/INDIRECT

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. LED - high performance LED

Low profile frame is just 0.5" thick CONFIGURATIONS

2001 TMT Associates 1

Emerging Lighting Technologies IEEE - March 21, 2001

LED HIGH BAY - SL 150W 200W BENEFITS APPLICATIONS MARKETS

FVT / LED Vapor Tight

2 1/2. Applies to both UP & DOWN. Specify quantity. Requires 8" blank See integrated controls guide for more details.

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

LED Lighting. LED Reflector. LED Downlight. LED Tube. LED Plug-in Tube. LED Sensor Batten. LED Floodlight. LED Lighting

Minimum operation time is 1,000 hours annually. Equipment is listed on the DLC QPL. Minimum operation time is 1,000 hours annually

FVH / LED Vapor Proof Highbay

2 LED Designer Series

Cubic SurroundLite TM

LED HIGH BAY - EXT EXTENDED LIFE BENEFITS APPLICATIONS MARKETS

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

T8 Retrofit. LED Tubes

Linear. FluxStream wraparound. 2', 4' and 8'

Vigilante Series. Wallpack. We light your world

DESCRIPTION PROJECT: Via 2 features our Asymmetrical Lens Optic for smooth, comfortable

2X4 LED RECESSED TROFFER

Steve Sindoni Commercial Engineer OSRAM Sylvania

LUMINAIRE ID DIRECT OPTICS INDIRECT OPTICS LIGHT SOURCE CRI DIRECT LUMEN PACKAGES. LED - high performance LED

Strip Light Series Sell Sheet

Voltage Driver Options UNV Universal voltage V V V V

Energy Saving Options for Small ISDs. Presented by Casey Stone, PE, CEM

REQUEST FOR PROPOSAL (RFP) # LED LIGHTING CONVERSION FOR SANTIAGO CANYON COLLEGE AND DISTRICT OPERATIONS CENTER

RECESSED T-Bar & Drywall. Project. Type. Notes 47 15/16" 47 7/8" 48" between T-Bar SIDE VIEW

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

LED HIGH BAY - SL STANDARD LIFE BENEFITS APPLICATIONS MARKETS

Replacement Lamps. Mercury Vapor Standard. Benefits. Features. Application

Part Number: BK - Black WT - White CS - Custom*

L3PNL. RECESSED LED IC PANEL 1'x4', 2'x2', 2'x4' FEATURES AND SPECIFICATIONS DIMENSIONS OVERVIEW

Linear Line Voltage LED Engine

VIA 2 LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

31 SERIES Modular area fixtures. Replaces: 1000W HID

Tove. High Performance Linear System Perimeter

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Cubic SurroundLite TM

Linear Replacement Lamps

Applies to both UP & DOWN. Outputs between listed min and max are available. Consult factory for other lumen packages

LEN Series 2x2 / 2x4 LED

WALL MOUNT DIRECT/INDIRECT. Project. Type. Notes

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH

PIX STICKS CIRRUS WITH POWER

GigaTera. LED Lighting LED LIGHTING CATALOG Commercial Lighting

Replacement Lamps. Mercury Vapor Standard. Benefits. Features. Application

LED Ceiling Mount Luminaires

style with efficiency

Voltage Driver Options DIM 0-10V 1% dimming SDIM 4 Step dimming to 40% input power XDIM 3,4 MarkX phase dimming DALI 5 DALI

Specification Sheet: Eco Area Light. Outdoor. 177 Broad Street, 12th Floor, Stamford, CT T rvlti.com

LIGHTING SPECIFICATIONS

FR Series Premium Commercial LED Luminaire

Linear. FluxStream strip

SURFACE MOUNT. Project. Type. Notes

MUST HAVES. in Quality lighting trusted by sparkies all over the globe.

SubstiTUBE IPS LED T8

LED CANOPY with j-box

LED lighting system. We Brighten Your Brands.

Project. Type. Notes PRODUCT ID NOM.LUMENS/FT CRI COLOUR TEMP. SHIELDING LENGTH/FT FINISH VOLTAGE

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

LED Lumina USA s Green Initiative

WALL MOUNT DIRECT. Project. Type. Notes

TECHNICAL SPECIFICATIONS

4' Planar Suspended and Surface LED Light Level Outputs. Lumens Delivered. Efficacy (LPW)

ALG LED Area Light K lm 21000lm 33000lm 100W 150W 300W. Type III Type V

THE MARKET S EASIEST FLUORESCENT-TO-LED CONVERSION

Electronic Fluorescent Ballasts

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

VIA 4 LED RECESSED W W W. L U M E N W E R X. C O M

Big Ass Light High Powered Fixture

light FULL BLEED APPLICATION SHOT RENDERING

Luminaires - LED High Bay

CATALOGUE.

75% ENERGY SAVINGS 200W-600W HID Light Replacement

Transcription:

PROJECT NAME: PROJECT NOTES: LED SOLUTIONS, INC. www.jaykal.net 26832 Lewes Georgetown Hwy, Building 2, Unit E Harbeson, DE 19951 (P) 302-295-0015 (F) 302-295-0016 DESCRIPTION: The simple design of the Retrofit Kit delivers maximum light distribution and is ideal for commercial and industrial troffer retrofit applications. The kit is engineered as a highly energy efficient and eco-friendly retrofit, delivering 139lm/W. By utilizing state of the art rare earth magnets, the bar FEATURES & BENEFITS: Wattage Options: 10W, 16W, 20W, 24W, 30W, 36W, 40W, 45W, 55W, 60W or Vari-Watt Drivers CCT Options: 3000K, 3500K, 4000K, 5000K 139+lm/W 5 Year Standard Warranty, 10 Warranty Available Thinner profile allows use in a wider range of applications. Available G2-MGT-BRIDGE accessory for elevating the bars, allowing a two bar kit to be used for retrofitting three lamp troffer applications. Comes with quick connects standard G2MGT-BRIDGE* 5 YEAR STANDARD WARRANTY EXTENDED WARRANTIES AVAILABLE

SPECIFICATIONS TABLE SPECIFICATIONS 10W 12W 16W 20W 24W 30W 36W 40W 45W 55W 60W Input Voltage Efficacy 100-277VAC 50/60hz 150+lm/W Lumens 1,500lm 1,800lm 2,400lm 3,000lm 3,600lm 4,500lm 5,400lm 6,000lm 6,750lm 8,250 9,000lm Power Factor >0.9 THD <15% CRI >80 L70 Hours CCT 75,000+ Hours 3000K/3500K/4000K/5000K Operational Temp. -30 C 50 C Housing Material Nano Polymer and Polycarbonate ORDERING GUIDE EXAMPLE MODEL - WATTAGE - LENGTH - CCT - DRIVERS - LIGHT BARS SENSORS JLS68102-G2MGT 10 = 10W 1 = 1 FT. 30K = 3000K Driver Options 1 = One Bar OC = Occupancy 12 = 12W 2 = 2 FT. 35K = 3500K N = Non-Dimming 2 = Two Bars OCBL = Occupancy Bi-Level Dim- 16 = 16W 20 = 20W 24 = 24W 30 = 30W 36 = 36W 40 = 40W 45 = 45W 3 = 3 FT. 4 = 4 FT. 40K = 4000K 50K = 5000K 10* = 0-10V Dimming P = Phase Dimming 50** = 50-50 Bi-Level *Included with VW and EMVW as standard. **50-50 Bi-Level dimming is optional on the VW and EMVW. 3 = Three Bars 4 = Four Bars Power Handling 4ft. Bars Max 20W ea. 3ft. Bars Max 15W ea. 2ft. Bars Max 10W ea. 1ft. Bars Max 5W ea. ming, One-Key Commissioning OCAL = Occupancy with Bi-Level Dimming, Wireless Grouping, One- Key Commissioning BLANK = No Sensor See Page 4 for Control Features 55 = 55W 60 = 60W Vari-Watt Driver (VW) M1 = (12W//16W/18W/24W) M2 = (18W/24W/30W/36W) M3 = (24W/30W/36W/40W) M4 = (40W/45W/50W/60W) Vari-Watt Driver with EM (EMVW) EM1 = (12W/16W/20W/24W) EM2 = (18W/24W/30W/36W) EM3 = (24W/30W/36W/40W) EM4 = (40W/45W/50W/60W) G2 ACCESSORIES GUIDE MODEL DESCRIPTION G2MGT-BRIDGE 1 PAIR BAR BRIDGES

Dimensional Drawings 2 FT. G2MGT 3 FT. G2MGT 4 FT. G2MGT

DIMENSIONS Option OC: ON/OFF Occupancy Sensing High Frequency Motion Sensor Hidden Installation Behind Diffuser Ambient Light Sensing Adjustable Detection Area Option OCBL: Occupancy Sensor with Bi-Level Dimming & One Key Commissioning Adjustable Detection Area Task Lighting/ Lumen Maintenance Ambient Light Sensing Daylight Harvesting High Frequency Motion Sensing One-Key Commissioning - Save the settings for the fixture and program each additional fixture with One-Key Press. Hidden Installation with LED/Daylight Spectrum Recognition Option OCAL: Occupancy Sensor with Bi-Level Dimming, Grouping and One-Key Commissioning Adjustable Detection Area Task Lighting/ Lumen Maintenance Ambient Light Sensing Daylight Harvesting High Frequency Motion Sensing One-Key Commissioning with Wireless Remote Hidden Installation with LED/Daylight Spectrum Recognition One-Key Commissioning - Save the settings for the fixture and program each additional fixture with One-Key Press. RF Wireless Grouping of up to 30 Fixtures.

Installation Guide for 2 and 4 Ft. MGT Kits 1. Disconnect AC power from the fixture 2. Begin by removing the existing lamps from the fixture. 3. Remove the ballast cover and set it aside, it will be reinstalled later. 4. Disconnect and remove the ballast and tombstone assemblies. 5. Install the LED driver in the location of the original ballast. The LED driver has a magnetic attachment to facilitate installation. One you have positioned the LED driver, install self tapping screws to secure the driver permanently in position. 6. Install the magnetic LED strips into the desired positions inside the fixture housing. The magnets at each end will hold the strips in place during installation. Install self tapping screws into the mounting holes to permanently position the strips. 7. Connect the LED driver and strips as illustrated for your application. (See Page 4 of this Document) 8. Reinstall the ballast cover which was removed in step 3, to protect the LED driver and wiring. 9. Reconnect fixture power and test for normal operation.

LED Bar Wiring Examples Configurations for 2 and 4 FT. Kits 2 or 4 ft. 1 Lamp Replacement 2 or 4 ft. 3 Lamp Replacement 2 or 4 ft. 2 Lamp Replacement 2 or 4 ft. 4 Lamp Replacement LED Bar Wiring Example Configurations for 6 and 8 FT. Kits 8 ft. 1 Lamp Replacement 6 ft. 1 Lamp Replacement 8 ft. 2 Lamp Replacement 6 ft. 2 Lamp Replacement