MP461SC Flex Probes* Installation Instructions

Similar documents
MP56xSA Flex Probes* Installation Instructions

TMS Series MP46x Flex Probes* Installation Instructions

SEN and SEN Outdoor Air Temperature Sensors

ArchWeigh 2000 Conveyor Belt Scale Weigh Idler For Single or Multiple Scale Bases

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

Pneumatic Isolation Module

M V Flex Probe Installation Guide. Part Number: M V, Rev. 0. Issue D ate: September 24, 2015 Supersedes: N/A

LTX RF LEVEL SENSOR. Instruction Manual

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Mini-Roto TM Paddle Wheel Installation & Operation Manual

Remote Sensor Kits. Installation Manual. Document No (Revision C)

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

Seismic Sensor Accessories SA, SV & ST 6000 Series

M100F Incremental Motor Actuator R81F Interface Board

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

Dispenser Pan Sensors & Containment Sump Sensors

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

1100 Series Piston Type Differential Pressure Gauges

MP-Series Integrated Gear Motors

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Signet 2517 Brass Paddlewheel Flow Sensor * *

LCD Annunciator Installation Instructions

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

1000 Series Piston Type Differential Pressure Gauges

Model APS 3B Snow and Ice Melting Control

7330 Pro-Stik II Magnetostrictive Level System

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Model DE-3 Air Release Heads Parts List

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Asepsis 21 Delivery Unit

HBDBM High Bay Series

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

TS Series TS Series

INSTALLATION INSTRUCTIONS Model FPT 50

High Frequency SineWave Guardian TM

TAG-DR Series. Indoor or Outdoor LED Driver Box - TAG LED Flood Solutions. Specifications. Overall Dimensions For Reference Only TAG-DR

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

IntelliTouch Expansion Center Kit

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

General Description. Product Specification. Document Digital Temperature Interlock

Model 124 Filter Minder & Model 124

Operation and Installation Manual

NATURAL GAS / LP REMOTE KIT & REMOTE DETERGENT KIT

Access XL Electric Projection Screen by Draper

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Operation & Maintenance Manual

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

PRO REMOTE Series CAPACITANCE PROBE

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Series 500. Liquid Level Transmitters. Instruction Manual

Reliant Series Floor Scale

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

The LED Driver Expert

Snow Switch Models HSC 4 (P/N 24220) & HSC 5 (P/N 24221)

Operating Instructions

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

High Bay Luminaire Series

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

Immersion Temperature Sensors

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

TABLE OF CONTENTS SPECIFICATIONS...3 SAFETY SUMMARY...4 INTRODUCTION...5, 6 INSTALLATION...7, 8, 9, 10 TESTING THE REMOTE OPERATION AIR PURGE...

Electric Vehicle Charging Station

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

The Time Is Right. Installation Instructions. Roast Beef Cooking Controller Upgrade. Model IR081C1H760X & IR081C1H765X

Rosemount 402 and 402VP

VIBRATING WIRE SURFACE STRAIN GAUGE. Model SM-5B. Roctest Limited, All rights reserved.

DURA-PANEL W OUTPUT: 12 VDC, 20 Watt W OUTPUT: 12 VDC, 50 Watt W OUTPUT: 12 VDC, 100 Watt

MODEL SCA Installation and Operation Manual Important:

Invensys (Foxboro) IMV25 Multivariable Setup

INSTALLATION INSTRUCTION

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

L E V E L P L U S M - S E R I E S ANALOG

Edelbrock EFI Universal Fuel Sump System - Adjustable Part #36031, INSTALLATION INSTRUCTIONS

ANNUAL UST SYSTEM INSPECTION CHECKLIST

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

MODEL D-SBG Single Arm Barrier Gate Operator

Installation Instructions. Y-Series Brushless Servo Motor

Lube Level Maintainer

Signet 515 Rotor-X Paddlewheel Flow Sensors

Transcription:

PNEUMERCATOR Liquid Level Control Systems MP461SC Flex Probes* Installation Instructions Model MP461SC Magnetostrictive Flex Probes For use with the following consoles: TMS2000 TMS3000 NOTE: MP461SC PROBES ARE NOT COMPATIBLE WITH TMS1000 SERIES AND Wireless DATA ACQUISITION MODULE (WiDAM) USED IN CONJUNCTION WITH WIRELESS CONSOLES. REFER TO MP561SC. * NOTE: BEFORE USING THIS BULLETIN, VERIFY MODEL NUMBER ON PROBE TAG IS MP461SC. COPYRIGHT 2012 PNEUMERCATOR CO., INC. TEL: (631) 293-8450 FAX: (631) 293-8533 WEBSITE: www.pneumercator.com PNEUMERCATOR TECHNICAL SUPPORT 1 (800) 209-7858 Bulletin 159 Rev. C (05/22/12) Page 1 of 8 4/12/2013 4:52:11 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

GENERAL SYSTEM OVERVIEW: Figure 1 shows a block diagram of how the system should be configured for installation. It is supplied as a guide to planning the installation. DATA DISPLAY/ GATHERING & CONTROL EQUIPMENT TMS CONSOLE CONSOLE OUTPUTS MODEM/RS-232/RS-485/RELAY CONTACTS RELAY CONTACTS 115/230 VAC 50/60 Hz POWER SENSOR/PROBE INPUTS FROM OTHER TANKS REMOTE MOUNTED ALARMS FIELD WIRING: SEE PAGES 7 AND 8. LEVEL PROBE FIGURE 1. SYSTEM BLOCK DIAGRAM LIQUID STORAGE TANKS! WARNING Refer to TMS installation manual for WARNINGS and CAUTIONS before proceeding. FAILURE TO COMPLY MAY RESULT IN PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. Bulletin 159 Rev. C (05/22/12) Page 2 of 8 4/12/2013 4:52:12 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

PRODUCT MP461SC level gauging probes utilize proven magnetostrictive technology for accuracy and reliability. Probes are supplied with (1) product float for product level gauging and optionally (1) interface float for bottom water gauging. Additionally the probe contains either(1) or (5) thermistors for temperature measurement. MODEL NO. OAL (IN.) (Overall Length) BOTTOM CLEARANCE (IN.) BOTTOM DEADBAND DIMENSION (IN.) MP461SC 55-150.50 3.00 2-COND., 22 AWG CABLE, 10 FEET LONG COLOR FUNCTION BLACK COM/GND (-) RED POWER (+) DRAIN/SHIELD DRAIN/SHIELD 1/2"-14 NPT OPTIONAL 316 STAINLESS STEEL S AND SPACER TUBE FOR 2" OPENINGS 7.00" INTERFACE PRODUCT 3/4" NPT ADJUSTABLE NYLON COMPRESSION FITTING, STANDARD (KYNAR AVAILABLE FOR CERTAIN APPLICATIONS) Ø.625 FLEXIBLE KYNAR GUIDE MAX. DIA. 2.05" P/N 170067-[ ] OR P/N 170090-[ ] BOTTOM SPACER TUBE (USED WITH 2" S.S. S) MAX. DIA. 2.05" P/N 170066-1 OR P/N 170089-1 BUNA-N PRODUCT MAX. Ø3.85" P/N 170100-1 SPAN OAL P/N 262126-2 (Ø.875" X 1.50" HEIGHT) OPTIONAL 316 STAINLESS STEEL S FOR 4" OPENINGS INTERFACE PRODUCT BUNA-N INTERFACE MAX. Ø3.85" P/N 170101-[ ] MAX. DIA. 3.85" P/N 170059-[ ] MAX. DIA. 3.85" P/N 170057-1 BOTTOM SPACER TUBE USED WITH 2" S.S. S ONLY LOCKING COLLAR 1/8" CLEARANCE 3" BOTTOM DEADBAND.50" BOTTOM CLEARANCE TANK BOTTOM APPLICATIONS: The MP461SC Flex Probes are generally used for inventory management of tanks up to 12.5 feet tall where installation of a rigid probe is not possible due to a low ceiling clearance or chemical incompatibility. UNPACKING: All probes should be visually inspected regardless of their shipping tube physical condition at delivery. Contact PNEUMERCATOR and the shipping company immediately if any of the parts (see page 4) are missing or damaged. During inspection and removal of the probe from the shipping carton, IMPORTANT: DO NOT LIFT THE PROBE BY IT'S ELECTRICAL CABLE! DO NOT BEND THE TOP 7 OR BOTTOM 3 INCHES OF THE PROBE! DO NOT REMOVE PROBE TAG! Consult the factory if you are not sure that the parts you received are suitable for your application. Bulletin 159 Rev. C (05/22/12) Page 3 of 8 4/12/2013 4:52:13 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

PNEUMERCATOR SUPPLIED COMPONENTS: (NOT SHOWN TO SCALE) CUSTOMER SUPPLIED COMPONENTS: (NOT SHOWN TO SCALE) GUIDE PROBE * Overall Length (OAL) as required from table on page 3. DO NOT BEND THE TOP 7 OR BOTTOM 3 INCHES OF THE PROBE! * UNLESS OTHERWISE SPECIFIED, PROBE IS SUPPLIED FULLY ASSEMBLED WITH THE COMPRESSION FITTING, BUSHING, COLLAR AND (S). OPTIONAL METAL MOUNTING COMPONENTS 2" X 3/4" NPT BUSHING BUSHING ASSEMBLY Example: 4" X 2" NPT and 2" X 3/4" NPT bushings assembled for threaded openings greater than 2" NPT ADJUSTABLE NYLON COMPRESSION FITTING, STANDARD (KYNAR AVAILABLE FOR CERTAIN APPLICATIONS) MATING FLANGE An appropriate bushing size must be used to connect the probe if the flange threaded opening is greater than 3/4" NPT. PVC BUSHING * Either A or B supplied A = 2" opening B = 4" opening JUNCTION BOX OPTIONS A B * CHECK COMPATIBILITY. OPTIONAL METAL MOUNTING COMPONENTS SHOWN ABOVE (UPPER RIGHT) MAY BE USED FOR CERTAIN CHEMICAL APPLICATIONS. C D E PRODUCT Either C, D or E supplied C = 2" opening or greater D, E = 4" opening or greater 1/2" NPT OR AS REQUIRED TYP F G H INTERFACE * Either F, G or H supplied F = 2" opening or greater G, H = 4" opening or greater * IF CONFIGURED FOR DUAL OPERATION. 1/2" NPT OR AS REQUIRED TYP BOTTOM SPACER TUBE Used with 2" S.S. floats ONLY LOCKING COLLAR If collar is disassembled, reattach to probe leaving a 1/8" clearance as shown on page 3 WIRE SPLICE SEAL CONNECTOR (Installation instructions included with connector) 1/2" NPT OR AS REQUIRED TYP NOTE: A QUALIFIED INSTALLER, FAMILIAR WITH LOCAL WIRING CODES AND EXPLOSION HAZARD ELECTRICAL PRACTICES MAY CONCLUDE THAT JUNCTION BOXES ARE NOT REQUIRED FOR CERTAIN INDOOR INSTALLATIONS. HOWEVER, WATERTIGHT BOXES MUST BE INSTALLED FOR ALL OUTDOOR INSTALLATIONS. Bulletin 159 Rev. C (05/22/12) Page 4 of 8 4/12/2013 4:52:14 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

INSTALLATION: WARNINGS: Installation is only recommended at temperatures 30 F or above. Probe damage may occur as a result of handling at lower temperatures, voiding warranty. Installation must be done by a qualified person, familiar with local wiring codes and explosion hazard electrical practices. While handling the probe and during installation, DO NOT CUT OR MODIFY THE PROBE. DO NOT LIFT THE PROBE BY IT'S ELECTRICAL CABLE! DO NOT BEND THE TOP 7 OR BOTTOM 3 INCHES OF THE PROBE! DO NOT REMOVE PROBE TAG! Probe mounting location should be selected to minimize effect from turbulence. DO NOT LOCATE IN A DIRECT LINE OF INBOUND OR OUTBOUND FLOW. 1 Normally the probe is shipped fully assembled and ready for installation. However, if needed, assemble the supplied components as required before proceeding.! CAUTION It is the INSTALLERS RESPONSIBILITY to ensure that they are adequately supported when handling the probe on top of the tank. FAILURE TO COMPLY MAY RESULT IN PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. 2 INSTALL PROBE: Loosen the compression nut (see detail on page 6) at the top of the probe, enough to slide it along the probe. Carefully feed the probe through the tank opening as shown below. THE PROBE CONTAINS ELECTRONICS. DO NOT BEND THE TOP 7 OR BOTTOM 3 INCHES OF THE PROBE! DO NOT REMOVE PROBE TAG! TOP 7" DO NOT BEND BOTTOM 3" DO NOT BEND TANK TOP TANK TOP TOP 7" DO NOT BEND 4' MIN. Bulletin 159 Rev. C (05/22/12) Page 5 of 8 4/12/2013 4:52:16 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

INSTALLATION CONT'D: 3 SECURE PROBE 4 COMPRESSION FITTING DETAIL COMPRESSION NUT SET BOTTOM CLEARANCE MARK PROBE AT THE TOP OF THE COMPRESSION FITTING HEX NUT USED TO SECURE FITTING MARK 1/2" TANK TOP TANK TOP Allow the probe to touch the tank bottom. Screw the mounting bushing into the tank opening. Do not over tighten. (Secure mating flange to tank flange for flange mount). Slide the compression fitting down to the mounting bushing/mating flange and secure. Do not tighten compression nut around probe yet. Mark the probe at the top of the compression fitting as shown. TANK BOTTOM Lift the probe (DO NOT LIFT THE PROBE BY IT'S ELECTRICAL CABLE) until the distance between the top of the compression fitting and the mark is 1/2" (this will give you the proper bottom clearance). Tighten the compression nut around the probe to hold it at this point. TANK BOTTOM 5 INSTALL HOUSING: A qualified installer, familiar with local wiring codes and explosion hazard electrical practices, may conclude that this step is not required for certain indoor installations. However, watertight boxes must be installed for all outdoor installations. WARNINGS DO NOT ALLOW CONDUIT WEIGHT LOAD TO BE APPLIED TO PROBE. HAND TIGHTEN HOUSING WHILE SECURING PROBE HEX FITTING NUT. DO NOT BEND OR STRAIN PROBE WHEN CONNECTING CONDUIT. TO CONSOLE HOUSING Bulletin 159 Rev. C (05/22/12) Page 6 of 8 4/12/2013 4:52:17 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

WIRING:! WARNING Refer to TMS installation manual for WARNINGS and CAUTIONS before proceeding. FAILURE TO COMPLY MAY RESULT IN PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT DAMAGE. TMS CONSOLE INTRINSICALLY SAFE WIRING COMPARTMENT 1" NPT FITTING (TMS3000) 3/4" NPT FITTING (TMS2000) NON-HAZARDOUS AREA HAZARDOUS AREA CLASS I, GROUPS C,D NON-INTRINSICALLY SAFE WIRING INTRINSICALLY SAFE WIRING VAPOR SEAL (AS REQ'D). PROBE CABLE JUNCTION BOX (SEE PROBE WIRING). FIELD WIRING CABLE SELECTION: Use Belden 8441, or any equivalent 2-conductor, 22 AWG shielded, twisted-pair cable, refer to TMS installation manual for more cable selection information. The field cable shield wire must be connected to the PROBE SHIELD TERMINAL in the console I.S. compartment and should be cut back and left unterminated at the probe junction box. TANK PROBE TYPICAL JUNCTION BOX WIRING WIRE SPLICE SEAL CONNECTOR FOLLOW SUPPLIED WIRE SPLICE INSTRUCTIONS BULLETIN 179; KIT P/N 10585-2 CONDUIT AND VAPOR SEAL FITTING (SIZE AND LOCATION TO BE DETERMINED BY QUALIFIED INSTALLER) WARNINGS DO NOT ALLOW CONDUIT WEIGHT LOAD TO BE APPLIED TO PROBE. HAND TIGHTEN HOUSING WHILE SECURING PROBE HEX FITTING NUT. DO NOT BEND OR STRAIN PROBE WHEN CONNECTING CONDUIT. WATERTIGHT RATED BOX NOT REQ'D IF DETERMINED BY QUALIFIED INSTALLER (SEE STEP 5 ON PAGE 6) PROBE CABLE PROBE FITTING BLK RED TO TO BLK RED TO CONSOLE (AS SHOWN ON NEXT PAGE) FIELD CABLE Note: The field cable shield wire must be connected to the PROBE SHIELD TERMINAL in the console I.S. compartment and should be cut back and left unterminated at the probe junction box. Bulletin 159 Rev. C (05/22/12) Page 7 of 8 4/12/2013 4:52:18 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.

WIRING CONT'D: TYPICAL WIRING FOR TMS CONSOLES PROBE 1 RED +V BLK GND SHD SHIELD +V GND SHIELD PROBE 2 C H A N N E L 1 P R O B E S E N S O R S RED BLK SHD 1 2 +V GND SHD GND SIG +V +V TMS2000 PROBE INPUT WIRING TMS3000 PROBE INPUT WIRING PROGRAMMING: Information necessary for programming this probe can be found on the tag attached to the probe. One side of the tag has certification information and the other side has information needed to program the TMS console to enable this probe. Copy the information from the tag on the probe onto this sheet and onto the tank worksheet in the TMS Operation Manual for referencing when programming the TMS. If you have more than 6 probes, make a copy of this sheet. USE THE EFFECTIVE LENGTH GIVEN ON THE TAG WHEN PROGRAMMING THE SYSTEM PROBE LENGTH PARAMETER. THE "SC" ON THE PROBE TYPE IS NOT NEEDED FOR PROGRAMMING. PROBE TAG EXAMPLE (BOTTOM SECTION) PNEUMERCATOR Liquid Level Control Systems SERIAL NUMBER: xxxxxx BASE P/N: MP461SC 106 21 PROBE CAL. FACTOR: x.xxx EFFECTIVE LENGTH: 99" DO NOT USE FOR PROGRAMMING USE THIS VALUE FOR PROGRAMMING Bulletin 159 Rev. C (05/22/12) Page 8 of 8 4/12/2013 4:52:20 PM, 1:1, COPYRIGHT 2013 PNEUMERCATOR COMPANY, INC.