24V Supply Operation & Specifications Manual. Field Tools. General Description

Similar documents
Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Model Battery Powered Milliohm Meter

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Auto-Off & Power Hold Function

DC Distribution Panel User Guide # S

5.2 PRE-OPERATION PROCEDURE WARRANTY

PTC8001 Temperature Calibrator

707Ex. Users Manual. ma Calibrator

INSTRUCTION MANUAL DM5B Fax: (503)

WENS30C Loop Calibrator

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Table of Contents Title Page No.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Cable Length Meter INSTRUCTION MANUAL

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

"WHERE TUBING AND FITTINGS COME TOGETHER"

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Tension your belts at the speed of light!

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

Temperature Calibrator

A Member of the. Integrated Metering Technologies

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Charging with AC (wall) Charger

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

EAGL 1-Touch Laser Level

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

HighLuxV2-Zenigata Series

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

User s Manual. Item no. 2561

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

This document describes:

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Model Number Structure

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CRD610 Automatic Fitting Inserter

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

HIGH VOLTAGE DIGITAL AMMETER

ROUSH Mustang Lowering Spring Kit

Motorized Stainless 2-Way Valves

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

Phase Sequence Tester

Integrated Back-up Battery System

This document describes:

User s Manual and Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Mustang Billet Rear Lower Control Arm Kit

CA 170 Owner's Manual

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

Dawson DDM190D. Digital Multimeter User s Manual

User s Manual Rev 1.3 GME

StormPro BA Series Sump Pump

BroadBand PowerShield. 20 AHr Battery. User Manual

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Component Test Fixture

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

SPC-PANEL Simplex, Single Phase Pump Control Panel

Melting Point Device DMP100 OPERATING MANUAL VERSION 1.11

SERIES DA PORTABLE HOIST

Car Vacuum Cleaner #CarVac

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

INW Panel Meter Reading an INW PT12 Sensor

Infinitybox Express Road Race Car Kit Installation Guide

Installation and Operation Guide

COLT CELL BATTERY CHARGER Installation and Operating Instructions

A Member of the. Integrated Metering Technologies

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Installation and Operation Guide

Operating Instructions for PAC800 Battery Charger

CRD600 Automatic Fitting Inserter

General Guidelines. Safety

Pick and Hold Module Pin Assignment and Description

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Please activate my limited warranty for WAGAN Corp.

Pump Installation and Service Manual HRS Hydromatic Retractable System

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

American Power Design, Inc.

Quick Start Guide Expansion Battery Pack UPS-OLEBPR-1 UPS-OLEBPR-2

SERIES L1B & L1D LADDERS

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

C3000 SIGNAL TRANSMITTER. Introduction

Image Pro. Create eye-catching holiday displays or project personalized images. Image projection system

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

SUPER PUMP OUT SYSTEM

J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface

2011+ Ford F-150 ROUSH Cold Air Kit for the V6 Engine Family 3.7L 4V Ti-VCT ( ) Installation Instructions

Transcription:

Field Tools 24V Supply 101-0028 Operation & Specifications Manual General Description The Field Tools 24V Supply provides portable power to loop powered devices. It is a fully contained power source that takes the low voltage from three AAA alkaline batteries and increases it to a highly filtered 24 volts DC. Using batteries for the power source eliminates isolation concerns as well as the need for a power connection to AC or a USB port. The voltage conversion is done using a high efficiency switching DC-DC converter to maximize battery life. Simply connect the two mini-clips to the power input of your loop powered device. A push-button is used to enable or disable the 24 volts while a status LED indicates the active operating mode. An internal 250 ohm loop resistor, HART protocol modem clip points, and current meter leads with standard banana jacks make the 24V Supply a complete loop transmitter power solution. 620-0012 R2a Microfl ex, LLC 2015

24V Supply Features Highly fi ltered 24 volt power source for loop devices Up to 30mA capacity, perfect for 4-20mA transmitters Battery power eliminates galvanic isolation concerns Includes an internal 250 ohm loop resistor to allow for HART protocol HART modem mini-grabber clip points for easy modem connection to the loop Mini-clips for easy connection to the loop device power terminals All connection leads included - no need for extra test leads or alligator clips Long battery life, greater than 6 hours continuous at 12mA load Status LED indicates when batteries are getting low Able to maintain output even with weak batteries to maximize battery life Uses easy to fi nd low cost standard AAA alkaline batteries Short circuit protection disconnects the output if shorted or over-current detected Compact durable enclosure stands up to rugged fi eld use Safety Considerations Warning To prevent loss or injury only use the 24V Supply as specifi ed in the manual. Never apply more than 30 volts between any two terminals or leads. Never operate with the battery cover and cover screws removed or loose. Do not use if the leads become damaged. Disconnect all connections before removing the battery cover. Do not operate around explosive gas, vapor, or dust. Contact Microflex, LLC for servicing or repairs. Replacing or Installing Batteries Always disconnect all leads and connections to the 24V Supply before removing the battery cover. 1. Loosen and remove the two cover screws and cover to access the battery holder. 2. Remove and replace all three AAA alkaline batteries. 3. Replace the cover and screws. Do not over-tighten the screws to prevent damage to the 24V Supply enclosure. For best performance the batteries should be replaced as soon as the low battery indication is noticed (flashing status LED while connected). 2

24V Supply Block Diagram 3 X "AAA" BATTERY REVERSE BATTERY PROTECTION HIGH EFFICIENCY DC-DC CONVERTER FILTER 24 VOLT TRANSMITTER POWER SUPPLY LEADS MILLIAMP METER TEST LEADS BATTERY MONITOR CONTROLLER CURRENT MONITOR STATUS LED 250Ω HART PROTOCOL MODEM CONNECTIONS CONNECT / OFF BUTTON Figure 1: Block Diagram Connecting to a Loop Device The Field Tools 24V Supply is a fully contained power source for loop powered transmitters. Internal batteries eliminate the need for external connections to AC power or USB ports as a power source while providing complete galvanic isolation. Connect the red clip to power or loop (+) and the black lead to power or loop (-) on your transmitter. See Figure 2 Device Connections for details. The transmitter can be powered with or without the milliamp meter connected. The power loop is not opened when the meter is removed or not attached. With the 24V Supply clips attached to the transmitter, press the 24V Supply connect button to enable power to the transmitter. The status LED will be ON while the 24V Supply output is active. If the LED is not ON solid while active, refer to Status LED Operation in this manual. To remove power from the transmitter press the connect button. The LED will be OFF while the 24V Supply output is inactive. The 24V Supply includes a 250 ohm loop resistor that will drop a portion of the available 24 volts. The voltage dropped across the resistor depends on the current requirements for the loop transmitter. Open circuit voltage, with no transmitter attached, is 24 volts +/- 2%. 3

MIN MAX Peak MIN MAX 4½ DIGITS 1 Second LO OFF C/ F RANGE AutoHOLD REL Hz % A ma A COM V 10A MAX FUSED 400mA FUSED Measuring Loop Current The 24V Supply includes leads to simplify connection to a DC current meter for loop current measurements. The current meter leads have safety insulated banana plugs that can be plugged directly into a standard current meter. An internal diode allows the meter to be connected or disconnected without interrupting the loop supply or opening the loop. See Figure 2 Device Connections for details. HART Protocol Modem Connections A HART modem or HART communicator can be connected to the 24V Supply loop using the two loop-terminals provided next to the current meter leads. The loop terminals allow standard HART modem mini-clips to be easily connected across an internal 250 ohm loop resistor. Connect a milliamp meter to the shielded banana jack leads to monitor loop current. Removing the current meter does not open the loop. Milliamp Meter (optional) V V mv ma A A Connect the red mini-clip to the transmitter (+) supply terminal. Connect the black mini-clip to the transmitter (-) supply terminal. Loop Transmitter For calibrating HART devices a HART protocol modem or calibrator can be attached across the internal 250Ω loop resistor by clipping on as shown. Figure 2: Device connections 4

Status LED Operation The Status LED provides quick feedback of the 24V Supply operating mode. The LED can indicate when the battery is getting low and needs to be replaced or when the output is shorted or connected to a load that exceeds the 30 milliamp maximum. LED Off If the status LED is off, the 24V Supply is not connected or not supplying power to the output. If the LED remains off after the button is pressed, the internal batteries need to be replaced. For details refer to the section on Replacing Batteries in this manual. LED On When the 24V Supply is active and providing power to the output, and no fault conditions are detected, the LED will be ON solid. LED Fast Flash then Off If an over-current condition is detected, more than 30mA or shorted, the output will be disconnected and the led will flash for about 2 seconds. Remove the overload or shorted condition and press the connect button to restore the active output. LED Slow Flash A slow flashing status LED indicates that the output is connected but the internal supply is low and the batteries need to be replaced. The 24 volt output may not be fully regulated when the batteries are low. Replace the internal three AAA alkaline batteries if they are low to ensure a stable power output. For details refer to Replacing Batteries in this manual. Auto Power Off To help reserve battery life the 24V Supply will automatically disconnect and power down after 30 minutes. Press the connect button to re-connect. 5

Specifications Output Open Loop Voltage...24V +/- 2% Load Regulation...0.25% Noise...Less than 50mV P-P @ 20mA Current...30mA max Short Circuit / Overload Protection... Auto-disconnect if load is > 30mA Leads...3 (1 meter) high fl exibility test lead wire Termination...Mini-Grabber clips Current Meter Leads Leads... 2 Feet (0.6 Meter) high fl exibility test lead wire Termination...Shielded banana plugs, Red (+), Black (-) HART Protocol Support Connection Type... clip loop terminals (.087 x.055 hole) 250Ω Loop Resistor...Included internally Battery Type...3 x 1.5V AAA alkaline Operating Life... > 6 hours with 12mA load Battery Supply Range (DO NOT USE 3V CELLS)...2.0V to 5.5V Low Battery Indicator...Status LED will fl ash slow while output is active Low Battery Level... 2.49V Auto Off duration... 30 minutes Enclosure Molded ABS Plastic Weight (including leads and batteries)... 6 ounces Enclosure Dimensions...1.70 x 3.25 x 1.13 Environmental Operating Temperature... -30ºC to 50ºC (-22ºF to 122ºF) Storage Temperature... -40ºC to 70ºC (-40ºF to 158ºF) Humidity...0 to 95% (non-condensing) 6

Dimensions (-) LOOP POWER + LOOP POWER STATUS LED CONNECT BUTTON 1.700 43.18 mm HART CLIP (-) CURRENT METER + CURRENT METER 1.125 28.58 mm 3.250 82.55 mm BATTERY COVER 36" SCREWS 915 mm 24" 610 mm Figure 3: Dimensions 7

Limited Warranty Microflex, LLC warrants this unit against defects in materials and workmanship for a period of one year from the date of shipment. Microflex, LLC will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. A Return Authorization (RA) number must be obtained from the factory and clearly marked on the outside of the package before equipment will be accepted for warranty work. Microflex, LLC believes that the information in this manual is accurate. In the event that a typographical or technical error exist, Microflex, LLC reserves the right to make changes without prior notice to holders of this edition. The reader should consult Microflex, LLC if any errors are suspected. In no event should Microflex be liable for any damages arising out of or related to this document or the information contained in it. EXCEPT AS SPECIFIED HEREIN, MICROFLEX, LLC MAKES NO WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF MICROFLEX, LLC SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. MICROFLEX, LLC WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITIES THEREOF. This limitation of the liability of Microflex will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against Microflex, LLC must be brought within one year after the cause of action accrues. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owners failure to follow Microflex s installation, operation, or maintenance instructions; owners modification of the product; owner s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control. Microflex, LLC 2202 Red Bird Lane Brookshire, Texas 77423 USA Phone 281-855-9639 Fax 832-422-4391 www.microflx.com