LED 2/3/4ft T8 Tube 120V

Similar documents
Product Installation Instruction LED Tube Lamp Retrofit Kits

TECTONIC LED CORP. ISO

Instruction/Installation Manual

Solid State T8 tube is the smart alternative to a

INSTALLATION INSTRUCTIONS


Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Universal Retrofit System Installation Instructions Revised:

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

LED Recessed Troffer Retrofit Kit

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

Installation Instructions BLTR and 2BLTR Relight Assembly

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

MAXLITE RKT LED Retrofit Kit

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Assembly Instructions Retrofitting

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Optimax Pro Retrofit Instructions

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

LED IMPORTANT SAFETY INSTRUCTIONS

Lumination TM LED Luminaire LUR Series

LED microwave sensor T8 tube light

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions: Eco-Fit T8 LED Tube Lamp

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Linear Tubes Compacts

SAVE THESE INSTRUCTIONS

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

PIL0478 ISSUE 01/ 07/16

LM79 LM80 L70:5+ YEARS

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Works in double and single ended wiring.

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

T8 Retrofit. LED Tubes

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

PDX and PX Retrofit Series

INSTALLATION INSTRUCTIONS STEP-DOWN TRANSFORMER HOUSING KIT

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

General Installation Instructions LED

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

LED Fluorescent Replacement

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LED T8 Full Glass Tube

LED Indoor Lighting Product Guide

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LED. High-performance streetlight. -afortable and reliable

ESLED4, ESLED5 Instructions

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

1992 Energy Policy Act A Pacific Energy Center Factsheet

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

13IN. WAREHOUSE BARN RETROFIT LIGHT OWNER S MANUAL

DE 02 Ceiling Luminaire, recessed

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

ECO EXT (DIMMABLE)

UL AND CODE COMPLIANCE

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

City of Ottawa Street Lighting. HID Shoebox Style Luminaire

MP/MTFL LIGHT FIXTURE (Dimming)

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

150W Explosion Proof High Bay LED Emergency Light Fixture - Remote Battery Enclosure - C1D1 Group B

INSTRUCTION MANUAL SINKER. By HAY

Lighting Tables for Existing/Base Equipment 4/15/2011

INSTALLATION INSTRUCTIONS

SURE-LITES FBP140XLP Instruction Manual

Lighting Tables for New Equipment 3/9/2016

Minnesota November 1, Take advantage of. LED rebates. and start saving

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

TAT120015AC8XX TJT120015AC8XX

18W Low Energy. instructions. Instructions

LED Lighting. Cooperative Purchasing Connection LED Lighting Offering

Installation Documentation ID-2663

CR Series and DR Series LED Downlights EASY TO INSTALL WITH UNPRECEDENTED PAYBACK

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Installation Instructions

HBC-20 - LED HIGH BAY

Solar Powered Explosion Proof LED Lighting - C1D1-2ft, Dual Lamp Fixture - Day/Night Sensor

DuraPro Hazardous Area Fluorescent

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

Transcription:

E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent lamps. The lamp rating is 120ac, 60 Hz, making it ideal for Consumer and Industrial Installations. A non-user replaceable light source and is known as a self-ballasted LED Tube Lamp. An electronic LED Driver is built inside the unit. For use in dry location only. Has been evaluated for use with ceiling fixtures and not suitable for use in totally enclosed recessed fixtures. Not for use with light dimmers. These lamps should be installed by an electrician, as these lamps work on line voltage and require all ballasts and starters to be removed before the bulb is to be installed in the fixture. Use in 25+/- 5 degrees C environmental conditions; Do not install in a raceway or a luminaire marked for through branch wiring. These devices are not intended for Use with emergency exits. Always connect ground lead to fixture where applicable. Our T8 Lamps are intended to retrofit maximum 4 lamps, Type IC or Non-IC Recessed, or surfacemounted fluorescent luminaire that use straight tubular maximum 2-foot or 4-foot lamp without diffuser. The lamp pins are at one end, and the other end is not connected to any electrical power and it serves as means of mechanical support only. Please connect your authorized dealer, distributor, or electrician if you have any questions not addressed in these instructions.

WARNING - IMPORTANT SAFETY INSTRUCTIONS Danger - Risk Of Shock - Disconnect Power Before Installation. WARNING - Risk of fire or electric shock. The electrical rating of these products are 120ac, the installer must determine whether they have 120 at the luminaire before installation. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. WARNING - Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when drilling for installation of reflector kit hardware. Check for enclosed wiring and components. WARNING - Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING - Risk of fire or electric shock. Install this kit only in the luminaire that has the construction features and dimensions shown in the photographs and / or drawings. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. For CNL products: "The retrofit assembly is accepted as a component of a fluorescent luminaire where the suitability of the combination shall be determined by CSA or authorities having jurisdiction." Not for use in totally enclosed Luminaires. "The end retrofit luminaire has been modified and can no longer operate the originally intended fluorescent lamp." "WARNING: Risk of fire or electric shock. Do not use this retrofit kit in luminaries employing shunted bi-pin lampholders." "The retrofit assembly is accepted as a component of a fluorescent luminaire where the suitability of the combination shall be determined by CSA or authorities having jurisdiction."

Installation Instructions LED T8 Tubes remove all the complexity of the wiring inside traditional Fluorescent Luminaire s/ Fixtures. Step 1: Remove ballast and starter where applicable, and the corresponding wires including branch circuit wires and ballast wires. If existing lampholder terminals are shorted by a jumper (as in instant start circuit), then remove the jumper. Step 2: Simply, Connect the L & N AC120 to one end of Tube lampholder / Base / Socket at One single End. The other end is left electrically unconnected, and is used as a mechanical retention only. Followings are installation of 3 different fixtures: a. Luminaire with starter: Figure 1 Traditional Tube Light with Starter

b. Luminaire with electronic ballast: Figure 2 Traditional Tube Light with Electronic Ballast c. These LED tubes can retrofit (for example) four lamps in one luminaire. The revised circuit diagram as shown in Fig.3. Figure 3 Quad Tube Fixture / Luminaire (Please see Fig1 & Fig2 for how to cut wires and to connect as above:

(3).Lamp Replacement Marking Label, See Fig 4 Figure 4 How to Affix Label from Tube to Luminaire Base After modification is complete, then affix the Lamp Replacement Marking label from the rear of the T8 tube onto the Luminaire itself, located where the label will be visible for future lamp replacements (i.e on the ballast tray, or luminaire base)