Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Similar documents
Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Mounting and Operating Instructions EB 6116 EN. System Electropneumatic Converter for direct current signals i/p Converter Type 6116

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Solenoid Valves Type 3963

Type 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN

Series 3730 Electropneumatic Positioner Type

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Competence in Functional Safety MANUAL. principle and typical applications

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Limit Switch Type 3776

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

Type 3421 Compact Controller with Type 3422 Controller Station and Type 3423 Controller Module

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Pneumatic Rotary Actuator Type 3278

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Electropneumatic Positioner Type Fig. 1 Type Mounting and Operating Instructions EB EN

Type 4746 Electric or Pneumatic Limit Switch

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Limit Switch Type 4747

TZIM. Electropneumatic Analog Positioner 10/ EN

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Solenoid Valve Island Type 3965

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Type 3271 Pneumatic Actuator. Actuator area: cm². Mounting and Operating Instructions EB EN

Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175 and 750 cm². Type 3271 Type Mounting and Operating Instructions EB EN

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

EB EN. Translation of original instructions. Type 3766 Pneumatic Positioner

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Type Electronic Limit Switch

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

Series 250 Pneumatic Control Valves Type and

Electronic Limit Switch Type

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Type 3967 Solenoid Valve

Masoneilan. Model 8007 and 8008 Electropneumatic Transducers. New Nozzle Design Minimises Effect of Vibration. Specification Data BS 6500 E 06/03

Limit Switch Type 3776

Series 240 Pneumatic On-off Valve Type 3351

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

A408 GB. Pneumatic oil and diesel pumps 1:1

Valve Series V2001 Three-way Valve Type 3323

Series 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Type 3660 and 3661 Positioners

Differential Pressure and Flow meters Accessories for the Media Series

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Solenoid Valve Type 3962

Masoneilan Models 8007 and 8008 Electropneumatic Transducers Instructions

The Series I/P Current to Pressure Transducer

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Table of Contents. Proportional & Precision Regulator Instrumentation

Self-operated Temperature Regulators Type 1u Temperature Regulator

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

Fisher 546 Electro Pneumatic Transducer

Series 3730 Type Electropneumatic Positioner. Fig. 1 Type Mounting and Operating Instructions EB EN ( )

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Max. oil content of compressed air

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

Series 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

ANSI version. The valve closes when the differential pressure rises

Electropneumatic Positioner Type Fig. 1 Type Mounting and Operating Instructions EB EN

Strainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

Data Sheet. I/P and E/P converters. RS stock numbers ,

Transcription:

Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011

Contents Contents Page 1 Description............................... 3 1.1 Application............................... 3 1.2 Technical data............................. 4 1.3 Principle of operation.......................... 5 2 Installation............................... 6 2.1 Mounting................................ 6 2.2 Mounting position............................ 6 3 Connections.............................. 7 3.1 Electrical connection........................... 7 3.2 Pneumatic connection.......................... 8 4 Operation............................... 9 5 Maintenance............................. 10 5.1 Troubleshooting............................ 10 6 Dimensions in mm........................... 11 2 EB 3913 EN

Description The device may only be mounted, started up or serviced by fully trained and qualified personnel, observing the accepted industry codes and practices. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings in these mounting and operating instructions, particularly those concerning assembly, start-up and maintenance, must be observed. Any hazards which could be caused in the device by the signal pressure are to be prevented by means of the appropriate measures. Proper shipping and appropriate storage of the device are assumed. The device with the CE marking fulfills the requirements of the Directive 94/9/EC and the Directive 89/336/EEC. The declaration of conformity is available on request. 1 Description 1.1 Application The devices are used to convert a direct current input signal into a pneumatic signal for measuring and control. They are especially suitable as intermediate elements between electrical measuring devices and pneumatic controllers or between electrical control devices and pneumatic control valves. The input of the converter is a load-dependent direct current from 0 to 20 ma. The output is a pneumatic signal of 0.1 to 4.0 bar (1.5 to 60 psi). Pneumatic connection: ¼ - 18 NPT (Type 3913-0001-0122010110000) or ISO-228/1 - G ¼ (Type 3913-0001-0222010110000) EB 3913 EN 3

Technical data 1.2 Technical data Type 3913-0001 Input Output Air output capacity (measured with 2 m hose 4 x 1) Auxiliary power Air consumption Performance Hysteresis Deviation from terminal-based conformity Influence in % of final value Dynamic response (acc. to IEC 60770-1) Effect of variable mounting position 0 to 20 ma Minimum current > 3.6 ma Load 6 V (corresponds to 200 at 20 ma 4 V) 0.1 to 4.0 bar (1.5 to 60 psi) 2.0 m 3 /h at 0.6 bar (8.7 psi) output 2.5 m 3 /h at 1.2 bar (17.4 psi) output Instrument air at least 0.4 bar (5.8 psi) above the upper signal pressure range value, maximum 4.5 bar (65 psi) without upstream pressure regulator 0.08 mn 3 /h at 1.4 bar (20 psi) ; 0.1 mn 3 /h at 2.4 bar (35 psi) Characteristic: Output linear to the input 0.3 % of final value, more accurate specifications on request 1 % of final value, more accurate specifications on request Supply air: 0.1 %/0.1 bar 1) Alternating load, supply air failure, interruption of input current < 0.3 % Ambient temperature: Lower measuring range value < 0.02 %/ C, span < 0.03 %/ C Limiting frequency: 5.3 Hz Phase shift: 130 Max. 1 %; 1 % when mounted horizontally Ambient temperature 25 to 70 C Degree of protection (acc. to IEC 60529) Materials Weight IP 65 Enclosure: Die-cast aluminum, chromated, plastic coated, glass fiber reinforced polyamide, other parts made of corrosive-resistant material Approx. 0.6 kg 1) Measured at average output pressure 4 EB 3913 EN

Description 1.3 Principle of operation The converter consists of an i/p converter module and a connected volume booster. The supplied direct current i flows through the plunger coil (2) located in the field of a permanent magnet (3). At the balance beam (1), the force of the plunger coil, which is proportional to the current, is balanced against the force of the dynamic back-pressure. The back-pressure is produced on the flapper plate (6) by the air jet leaving the nozzle (7). The air supply (SUPPLY 8) flows into the lower diaphragm chamber, during which a certain amount of air determined by the diaphragm position flows past the sleeve (9) to the output (OUTPUT 36). When the input current increases and, as a result, the forces at the plunger coil increase as well, the flapper plate (6) moves closer to the nozzle (7). This causes the dynamic back-pressure and the cascade pressure p K forming in front of the restrictor (8.2) to increase. The cascade pressure increases until it is equal to the input current. When the cascade pressure increases, the diaphragm (10) and the sleeve (9) are pushed downwards, causing the supply air to increase the output pressure p A until a new state of equilibrium is reached in the diaphragm chambers. When the cascade pressure drops, the diaphragm moves upwards, releasing the sleeve and allowing the output pressure p A to pass through the sleeve to be vented (EXHAUST port) until the forces at the diaphragm are equal again. 1 Balance beam 2 Plunger coil 3 Permanent magnet 4 Zero and span adjusters 5 Slide switch 6 Flapper plate 7 Nozzle 8 Volume booster 8.2 Fixed restrictor 9 Sleeve 10 Diaphragm i/p module Fig. 2 Functional diagram EB 3913 EN 5

Installation 2 Installation 2.1 Mounting The converter can be mounted as illustrated in Fig. 5. The device is delivered with a stainless steel (1.4301) bracket for wall mounting. 2.2 Mounting position Mount the device horizontally with the pressure gauge (or stopper plug) pointing upwards. 6 EB 3913 EN

1 3 Connections 3 Connections 3.1 Electrical connection As far as the electrical installation of thedeviceisconcerned,therelevant national regulations governing the installation of electrical equipment and the national accident prevention regulations of the country of destination must be adhered to. In Germany, these are the VDE regulations and accident prevention regulations of the employer's liability insurance. A male angle connector conforming to DIN EN 175301-803 A is used for electrical connection. 1. Unscrew the fixing screw (1) of the connector plug and pull the plug insert (3) out of the plug base at the enclosure. 2. Pull the screw out of the plug and remove the seal (5). 3. Place a screwdriver at the recess (4) and lever the plug insert (3) out of the plug housing. 4. Run the wires for the input signal over the cable gland of the plug housing to the terminals of the insert marked 1 (+), 2 ( ) and screw them down. 5 4 3 2 1 4 2 3 1 1 Fixing screw 2 Connector plug housing 3 Plug insert 4 Recess 5 Seal 6 Cable gland 1 (+) 3 (+) 2 ( ) 6 0...20 ma Fig. 3 Terminal assignment on the plug connector EB 3913 EN 7

Connections 5. Push the insert into the plug housing, making sure that the cable gland points in the correct direction after the connector plug has been reassembled (the plug housing can be mounted in all four directions, turned at 90 angles around the insert). 6. Plug the connector plug on the device and screw tight the screw (1). 3.2 Pneumatic connection The connections for supply air (SUPPLY 8) and output air (OUTPUT 36) are designed as bores with G ¼ or ¼-18 NPT thread. Note! Customary screw glands for metal pipes or plastic hoses can be used. When extending the exhaust by connecting a pipe either to the exhaust angle piece or directly to the G or NPT connection, make sure that no water can enter at the end of the pipe. The pipe must have a sufficiently large cross-section area of at least 28 mm² = 6 mm inside diameter. 8 EB 3913 EN

Operation 4 Operation The device converts the input signal proportionally into the output signal. The signal ranges are specified on the nameplate. The zero and span can be corrected by approx. 10 % using the electronics. To do this, proceed as follows: Example: The output signal 0.1 to 4.0 bar is to be assigned an input signal of 0 to 20 ma. 1. Unscrew the enclosure cover to access the ZERO and SPAN potentiometers on the printed circuit board. Zero: 2. Connect a pressure gauge (minimum accuracy class 1) to the output of the device. 3. Set the supply air to at least 0.4 bar above the upper range value of the output signal and apply it to the device. 4. Set the input signal to the lower range value 0 ma using a suitable current source. The output signal at the test pressure gauge should indicate a lower range value of 0.1 bar. Span: 5. Set the input signal to 20 ma using a suitable current source. The output signal at the test pressure gauge should indicate the upper range value of 4.0 bar. Should another value be indicated, readjust the span accordingly with the SPAN potentiometer. 6. Change the input signal abruptly from the upper range value 20 ma to 0 ma (or gently tap the device) and check whether the output signal assumes the upper range value, e.g. 4.0 bar. Since the adjustments of zero point and span influence each other, check both values again and correct them, if necessary. OFF ON 0 to 20 ma version ZERO SPAN Should another value be indicated, readjust the zero point accordingly with the ZERO potentiometer. Fig. 4 Adjusters with enclosure EB 3913 EN 9

Maintenance 5 Maintenance No particular maintenance steps are prescribed. Proper functioning of the converter can only be guaranteed when the instrument air applied to the device is always clean. The air filter and separator of the pressure reducing station should be checked at regular intervals. The pneumatic connections have filters with plastic rims (order no. 0550-0213) which can be unscrewed and changed or cleaned. 5.1 Troubleshooting Problem Possible cause Countermeasure Comments No output signal despite changing the input signal Supply air not connected Incorrect terminal assignment Check supply air connection, see section 3.2 Connect + and Caution! terminals correctly, see Converter does not need any section 3.1 extra voltage! Do not connect 24 V DC! Incorrect input signal Connect correct signal See nameplate: 0 20 ma Converter constantly vents off air loudly Converter does not reach 100 % output e.g. 20 ma input: Output only 70 % instead of 100 % Connections for supply air and output at the converter mixed up Supply air is too low Input signal faulty Check pneumatic connection, see section 3.2 Supply air must be 0.4 bar greater than the max. output signal (supply air = 0.4 bar) Check whether the input signal at the terminals reaches 100 % (100 % is in standard version, e.g. 20 ma, with split-range 12 ma) See nameplate: Output 0.1 4.0 bar > Supply air at least 1.4 bar; max. 4.5 bar Caution! Converter has a load of max. 6 V. Check specification concerning control. 10 EB 3913 EN

Dimensions in mm 6 Dimensions in mm 3 136 120 100 Ø7 4 50 74.5 126 1 1 Vent filter (IP 65) 2 Electrical connection (angle connector DIN EN 175301-803 A) 3 Pressure gauge 4 Mounting bracket 2 75.5 Fig. 5 Dimensions EB 3913 EN 11

SAMSOMATIC GMBH A company of the SAMSON GROUP Weismüllerstraße 20-22 60314 Frankfurt am Main Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1644 E-mail: samsomatic@samsomatic.de Internet: http://www.samsomatic.de EB 3913 EN S/Z 2011-09