ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Similar documents
ODY-19-1 AIR PRESSURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE

ODY-10-1 rev. B FUEL PRESSURE GAUGE

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

ODY-01-1 or ODY-01-2 SPEEDOMETER

HLY-1013 or HLY-1014 MINI SPEEDOMETER

ODY-17-1 DIGITAL COMPASS DISPLAY

ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

ODY-19-6 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

Universal Gear Shift Sender for use with Lokar Indicators GSS-1000-LOK The easiest system to install and use on the market.

ION-01-6 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO

PAC-3100 LINEAR MOTOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

UTV-1200 Multi Gauge for 2008 Yamaha Rhino

Series II ODYR/SLX-01-1-C PERFORMANCE SPEEDOMETER

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

DCC-3000 Climate Control for Vintage Air GEN-IV systems

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

UTV-1000 Multi Gauge for Yamaha Rhino

HLY-3016 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO (weather and vibration resistant for exposed environments)

Installation Instructions Receiver Rack (Part # 7700) Universal Application

INSTALLATION AND OPERATION MANUAL FOR MCH-GPS17 GPS Compass and Ambient Temperature Gauge. NUTS (x3) 1 +12V TEMP SENSOR

MCL-3000 SERIES AIR PRESSURE PART# MCL-3K-A

MCL-30K-SPD IMPORTANT NOTE!

CPL 100 Owner's Manual

BIM-17-2 Bus Interface Module for compass and outside temperature

MCL-5100, 5200, & 5400 Bar mount digital speedometer with indicators.

HLY-3015 MINI SPEED/TACH INFORMATION SYSTEM (weather and vibration resistant for exposed environments)

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

MCL-3000 SERIES OIL TEMP PART# MCL-3K-TMP

Installation Instructions Soft Top Replacement Hardware, Wrangler

MODEL HLY-2001 rev. B TANK MOUNT SPEEDOMETER/TACHOMETER INFORMATION SYSTEM

Installation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743

Universal Tablet Mounting Kit with Built-In FM Transmitter 88.7 IPD-UNVBT OWNER S MANUAL IPD-UNVBT 3_14_14.indd 1 3/14/2014 5:28:50 PM

Jeep JK Wrangler Modular HD Front Winch Bumper

DSL-1 E DIESEL TACH INTERFACE UNIT

Installation Instructions BULL BAR (Part # 51033&51034) SIERRA 1500 / SILVERADO 1500

WARNING: DO NOT USE HAND-HELD 2-WAY TRANSCEIVERS INSIDE YOUR VEHICLE WHILE DRIVING.

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

Owner s Installation Guide

MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER

WARNING: DO NOT USE HAND-HELD 2-WAY TRANSCEIVERS INSIDE YOUR VEHICLE WHILE DRIVING.

ca1153 Owner s Guide

Owner s Guide ca4054 ca4554

Owner s Guide CA 1155

Owner s Guide CA 1055

BIM-01-2-MEGA Bus Interface Module for MEGASQUIRT EFI BIM-xx-2 power & data connectors. Either one can be used.

Owner s Guide. ca5154

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

HD Cross Over Steering System. P/N: (XJ-TJ-ZJ) ( YJ)

Owner s Guide CA 4555

STC2 Car Kit. Installation Guide

CA 5054 Owner s Guide

Slip Yoke Eliminator Kit For NP231 Part Number 52231

Owner s Guide. ca5354

MODEL MCV-7000 series SPEEDOMETER/TACHOMETER INFORMATION GAUGE Please read this before beginning installation or wiring.

Owner s Guide CA 5055

AOM-78 7 MONOCHROME OBSERVATION 90 DAY/12 MONTH LIMITED WARRANTY

Owner s Guide PR1BZ PR1BZLR

Owner s Guide APS596Z

Owner s Guide CARS & CA4B5

SOLAR DASH CHARGING SYSTEM USER GUIDE

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Owner s Guide. ca6154

MODEL MCL-2002 TANK MOUNT SPEEDOMETER/TACHOMETER

Installation Instructions

This document describes:

This document describes:

MCL-3014 gauge kit. Optional Readings: Boost Pressure with MBM-09, Front or Rear Air Suspension Pressure with MBM-19

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

CONTROL BOX. Wiring the control box into the vehicle. +12V

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 60KW, PVI 82KW, PVI 95KW

GPS-50-2 GPS Speed and Bus Interface Module

MODEL MCL-2004(-R) TANK MOUNT SPEEDOMETER/TACHOMETER

Tachometer. English. Users Manual

NISSAN 370Z INTELLI-KEY Rev.:

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Wiring Main Power connector constant 12V power

Lint Slide Grid Moist Air Applicator

10 Ch Peak & Hold Injector Driver PN

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

RECHARGEABLE 24 LED WORK LIGHT

Owner s Guide CARS & CA2LCD5

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

CA 170 Owner's Manual

Seat Comfort Systems

Part Number Analog EGT Gauge

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Transcription:

ODY-05-2 VOLTMETER FOR REMOTE MONITORING Introduction: The Odyssey gauge series from Dakota Digital, Inc. incorporates the reliability and quality of our standard gauges, along with several unique features and easy mounting. These features include: A warning feature that flashes the gauge readout when outside operating limits. A connection for an external warning indicator that is activated when the gauge flashes. User adjustable warning points. Microprocessor stabilized readings. Quick-Start feature to provide accurate readings quickly after being powered up. Night dimming with lens label lighting. High Visibility VFD display for sunlight readability. The voltage gauge for remote monitoring will read the voltage at an extra battery, amplifier power connection, or other system that needs to be monitored. The gauge will be powered from a standard accessory terminal and not from the point it is monitoring. The voltage gauge will operate and read correct between the voltage range of 0.0-17.0 volts. While the accessory power for the gauge must be at least 8 volts, it can monitor voltages down to 0 volts. It has a user adjustable upper and lower warning level. This can be set to indicate low voltage and over voltage conditions

Operation: The gauge needs only the red and black wires connected to operate. When the blue wire has 12 volts, it will dim the display for night viewing. The gray wire is for the voltage monitor connection. The yellow wire will provide a ground output when the gauge reading is outside the high or low warning limit. Setting the warning limits: The high and low warning limits can be set to different values. Once they have been set, they are stored internally so that the gauge will retain the values even when the gauge does not have any power. These values can be set and reset as many times as desired. The procedure for setting the warning limits is as follows: 1. Make sure the key is off so the gauge is not powered. 2. Press and hold the SET button. This is located behind the hole located on the back side of the gauge as shown in figure 1. 3. Turn the key on while the SET button is being held. 4. Release the button. The gauge should show LO and then switch to a reading between 8.0 and 11.0. 5. Turn the warning adjustment pot until the desired low voltage limit is showing. The adjustment will then 3/4 rotation from stop to stop. Do not force it past either stop. 6. Press and release the SET button. The gauge should show HI and then switch to a reading between 14.0 and 17.0. 7. Turn the warning adjustment pot until the desired high voltage limit is showing. 8. Press and release the SET button. The gauge should show --. The new warning limits are now stored. 9. Turn the key off. The gauge will now operate normally when powered up again.

Using external warning indicators: The yellow wire provides a ground trigger whenever the gauge is outside its set limits. Low current indicators (less than 0.25 A) can be activated directly by connecting their power wire to 12 volts and connecting their ground wire to the yellow output wire. Many gauges can share the same indicator by connecting their yellow warning wires together. In this way, when any one or more gauges are outside their limits the warning indicator will be activated. For higher current buzzers or lights, a relay will need to be used to switch the indicator on. Dakota Digital s RLY-1 30A relay may be used for this. One of the coil wires should be connected to 12 volts and the other coil wire connected to the yellow warning wire. When the gauge is outside its limits, the relay will turn on. The relay contact wires can be used to switch the higher current. Wiring: WARNING! CONNECTING A HIGH CURRENT INDICATOR DIRECTLY TO THE WARNING OUTPUT WILL DAMAGE THE UNIT. BLACK - connect to a good ground point in the vehicle. RED - connect to an accessory terminal from your fuse block. GRAY - connect to where you want to monitor the voltage. BLUE - connect to the tail light circuit. YELLOW - (optional) connect to warning indicator.

Mounting: The gauge requires a rectangular cut out that is about 2 9/16 x 1 11/16. It should be inserted into the opening from the front and the U-clamp will be installed from the back. Tighten the two nuts on the U-clamp so that the gauge is secure. Figure 2 shows the required cut out for the gauge. Figure 3 shows how the gauge mounts.

Troubleshooting guide. Problem Possible cause Solution Gauge will not light up Red wire does not have Connect to a location that has power. power. Black wire is not getting Connect ground to a different location. a good ground. Fuse is blown. Replace in line fuse. (2 amp only.) Gauge is damaged. Return gauge for repair. (see instructions) Gauge lights up, but does Loose connection on red Reconnect red wire. not read correctly. power wire. Poor ground connection. Move ground to different location Loose connection on sensing Reconnect or replace wire between gauge wire. and monitoring location. Voltage or wiring problem Check wiring harness for loose or damaged in vehicle wiring harness. wires. Gauge is not calibrated Gauge must be recalibrated. correctly. (contact factory) Gauge flashes constantly. Warning limits are not set Reset warning limits. properly. Monitoring voltage is over or Check voltage monitoring location. under warning limits. External warning indicator does not work. Indicator not connected Check indicator wiring connections. properly. Indicator does not work. Repair or replace indicator. Gauge output has been Return gauge for repair. (see instructions) damaged. Gauge will not dim. Blue wire is not connected Check wiring connections. correctly. Gauge remains dim at all Blue wire is getting power Connect blue wire to location that only times. all of the time. has power when the headlights are on. Battery is very low. Gauge is damaged. Recharge or replace vehicle battery. Return gauge for repair. (contact factory) SERVICE AND REPAIR DAKOTA DIGITAL offers complete service and repair of its product line. In addition, technical consultation is available to help you work through any questions or problems you may be having installing one of our units. Should you ever need to send the unit back for repairs, please package the product in a good quality box along with plenty of packing material. Ship the product by UPS or insured Parcel Post. Be sure to include a complete description of the problem, your full name and address (street address preferred), and a telephone number where you can be reached during the day. An authorization number for products being returned for repair is not needed. Do not send any money. We will bill you for the repair charges. Any returns for warranty work must include a copy of the dated invoice or bill of sale.

Technical specifications Minimum operating voltage - 7 volts Maximum operating voltage - 18 volts (operating at or near maximum rating for an extended time can damage unit) Gauge Range - 0.0-17.0 volts Gauge Resolution - 0.1 V Gauge accuracy - ±0.1 V Typical current draw (@ 13.8V) - 0.13 A Warning indicator max current - 0.3 A ODYSSEY SERIES DIGITAL GAUGE LIMITED WARRANTY DAKOTA DIGITAL (the Company) warrants to the ORIGINAL PURCHASER of this product that should it, under normal use and condition, be proven defective in material or workmanship within 24 MONTHS FROM THE DATE OF PURCHASE, such defect(s) will be repaired or replaced (at the Company s option) without charge for parts or labor directly related to repairs of the defect(s). To obtain repair or replacement within the terms of this Warranty, the product is to be delivered with proof of warranty coverage (e.g. dated bill of sale), name, address, phone number, and specification of defects, transportation prepaid, to the factory. This Warranty is valid for the original purchaser only and may not be transferred. This warranty does not cover nor extend to damage to vehicle electrical system. This Warranty does not apply to any product or part thereof which in the opinion of the Company has been damaged through alteration, improper installation, mishandling, misuse, neglect, or accident. This Warranty is in lieu of all other express warranties or liabilities. ANY IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABLITY, SHALL BE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. ANY ACTION FOR BREACH OF ANY WARRANTY HEREUNDER INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABLITY MUST BE BROUGHT WITHIN A PERIOD OF 24 MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, WHATSOEVER. No person or representative is authorized to assume for the Company any liability other that expressed herein in connection with the sale of this product. The Company does not warrant that this product cannot be compromised or circumvented. THE EXTENT OF THE COMPANY S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT PROVIDED ABOVE AND, IN NO EVENT, SHALL THE COMPANY S LIABILITY EXCEED THE PURCHASE PRICE PAID TO THE PURCHASER FOR THE PRODUCT. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation if incidental or consequential damage so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 4510 W. 61ST St. N., Sioux Falls, SD 57107 Phone: (605) 332-6513 FAX: (605) 339-4106 www.dakotadigital.com dakotasupport@dakotadigital.com Copyright 1997 Dakota Digital Inc.