Instruments for Chemical and Petroleum Products. Flash Point

Similar documents
PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Instruments for the Analysis of Petroleum Products. Oxidation Stability

ADU 5. Automatic Distillation Unit

Closed Cup Flash Point Tester

Callisto 100. Cold Filter Plugging Point Tester

Stabinger Viscometer SVM 3001

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Stabinger Viscometer Series. SVM Series

Penetration. Test Methods

Low cost EDXRF elemental analyzer

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Sulfur in Oil Analyzer

Solution Sheet 1.

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester 1

TESTING OF FUELS : FLASH AND FIRE POINT

Viscometry Rheometry. The Range. ::: Intelligence in Rheometry

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Refrigerated incubator with Peltier technology

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

L U B R I C A N T S & MATERIALS

Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester 1

Vertical Tensile Machine

Foaming of Lubricating Oils (manual)

Jet Fuel Conductivity Analysers & Additive Management systems

Bio II Advance. Class II Biological Safety Cabinet

breakthrough versatility

Optidew Vision Optical Dew-Point Meter

Temperature multi-function calibrator Model CTM

Thermo-anemo-manometer MP 210

Manual Kinematic Viscosity Bath Tamson TV12

SCOPE OF ACCREDITATION

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Energy Engineering Lab

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Portable TOC Analyser for Stack Emissions

Flash Point Process Analyzer

Products for Asphalt Testing

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

Elemental Analysis Advanced

Accessories for the measurement of tightening torque. Digital and electronics dynamometric wrenches

TQC s production facility is located in The Netherlands TQC has distributors in more than 60 countries TQC, DEVELOPERS AND MANUFACTURERS OF PAINT TEST

Bio II Advance. Class II Biological Safety Cabinet

MANUAL ABOVE GROUND TANK FOR INSITE STORAGE OF ADBLUE WITH PUMP

SECTION 118 ASPHALT MATERIAL

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Superstatic 440. Static Heat- and Cooling Meter. Application

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Determination of flash point Pensky-Martens closed cup method

ElvaX Sulfur in Oil analyzer

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester 1

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Integrated temperature test and calibration bench Model CBS-SC4000

SVM Stabinger Viscometer. ::: Viscometry at its best

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Multi-Parameter Certified Reference Material

PETROLEUM TESTING EQUIPMENT N-WISSEN 2016

Standard Test Method for Freezing Point of Aviation Fuels (Automated Optical Method) 1

Standard Test Method for Flash Point by Tag Closed Cup Tester 1

Mixer/Temperature Control

Electromagnetic Flowmeters. Product Overview.

Machine Specification

Thermo-anemo-manometer MP 210

CERTIFICATE OF ACCREDITATION

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Cooled incubators (ST), laboratory refrigerators

Thermo-hygrometer-anemometer VT 210

Equipment Specification MK66E-M-PC Flamespray System

ISOCAL - 6 Range Europa Venus Calisto

Zirconia Oxygen Probe

Thermo-hygrometer-anemometer VT 210

A Tradition of Competence

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Crude Oil and E&P Testing Laboratory Instruments for quality control, analysis and calibration

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing

AVL Particle Measurement System Aviation

Fuels. Test Methods

Interface I-300 / I-300 Pro Technical data sheet

White Paper.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Standard Test Method for Dropping Point of Lubricating Grease 1

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Safety drying oven with expended temperature range

orb effortless reactions Unrivalled quality» Intuitive design» Exceptional value

For reliable control of small, large or multi-system-type lubrication systems

CFA. Carton Force Analyser

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

Thermo-anemo-manometer

ERWEKA 8 ELNOVA ZT30 ZT40 ZT50 ZT60 ZT70 _!! disintegration testers ZT 20. If* h» L i J. Handelsgesellschaft mbh ERWEKA

Advanced Force / Torque Indicator

Thermo 90 S.21 Diesel - 24 Volt

SINAMICS GM150 IGCT version

Mineral Turpentine Adulterant in Lubricating Oil

Transcription:

Instruments for Chemical and Petroleum Products Flash Point

A Tradition of Competence 140 years of technological advances lie between the first flash point tester and today s Anton Paar product line of flammability measuring instruments. Mr. Berthold Pensky developed the first closedcup flash point tester and set a milestone for the production of high-quality and high-precision flash point testers. Aligned to the requirements of various industrial branches the instruments from Berlin met a worldwide demand. The acquisition of Petrotest by Anton Paar resulted in the combination of the spirit of research and inventive talent with the advantages of a worldwide, well-established sales and service team. Founded in 1922, Anton Paar today employs over 2000 people in 20 countries who manage a global business and provide the whole value chain, starting from product ideas, research and development, production, sales, application support and after-sales services. As a result of this unique concentration of talents and know-how, Anton Paar's product portfolio has grown continuously. It now covers a wide range of laboratory instruments, process technologies and automation systems, ranging from standardized QC to complex R&D solutions. Anton Paar is close to you and your work. An experienced local team speaks your language and provides application support and training. Anton Paar thinks globally and acts locally.

Flash Point Measurement All methods all standards one product line Anton Paar has the suitable flammability tester for each type of measuring task in its product line. Tests according to standardized methods in the temperature range of -30 C to 400 C are possible to cover a wide range of applications. This includes: the petrochemical field, calibration and regulation authorities, transportation and shipping, engineering, waste management and the cosmetics and food industries. Cleveland method open-cup determination for expecting flash and fire point in the range of 79 C to 400 C (175 F to 752 F). Pensky-Martens methods closed-cup determination for expecting flash point in the range of 40 C to 370 C (104 F to 698 F). Comprising: Method A for distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils and other homogeneous liquids. Method B for residual fuel oils, cutback residual, used lubricating oils, non-homogeneous materials like mixtures of petroleum liquids and solids, surface-film-building petroleum liquids. Method C for biodiesel (FAME). Requires electronic flash point detection! Pensky-Martens closed-cup (PMCC). PMA 5 is standardized for both biodiesel and biodiesel blended fuels along with distillate fuel such as diesel, heating oil and kerosene and potentially flammable liquids as lubricating oils. Product highlights are: ``One-Twist head ``Multi-detector ``Integrated fire-extinguishing device ``Gas and electric ignition ``1-button operation ``Tray For standardized, comfortable, versatile and safe flash point testing the PMA 5 Pensky-Martens tester is the right choice! Tag method closed-cup determination for expecting flash point below 93 C (200 F). Abel method closed-cup determination for expecting flash point in the range of -30 C to 70 C (-22 F to 158 F).

All Methods All Standards One Product Line ABA 4 Abel Flash Point Tester Standard methods Abel flash point: ISO 13736, IP 170 Equilibrium procedure: ISO 1523, IP 492, EN 924, ISO 1516, IP 491 Optional Abel-Pensky: DIN 51755-1 TAG 4 Tag Flash Point Tester Standard methods Tag flash point: ASTM D56, FTM 791-1101 Equilibrium procedure: ASTM D3941, ISO 1523, IP 492, EN 924, ASTM D3934, ISO 1516, IP 491 Benefits at a Glance ``Two cooling systems with Peltier elements according to the ISO 13736 standard: an economical air-cooled model and a low-temperature version with external water cooling ``The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary ``The One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter-release, igniter, and detector contacts ``An extended measuring range up to 110 C enables you to go beyond the conventional scope of the Abel method Benefits at a Glance ``Two cooling systems with Peltier elements are available: an economical air-cooled model and a low-temperature version with external water cooling ``The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary ``The One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter-release, igniter, and detector contacts ``An extended measuring range up to 110 C enables you to go beyond the conventional scope of the method

PMA 5 Pensky-Martens Flash Point Tester Standard methods Pensky-Martens methods for petroleum products: ASTM D93 A+B+C, ISO 2719 A+B+C, JIS K 2265-3 A+B, IP 34 A+B, GOST R EN ISO 2719 CLA 5 Cleveland Flash & Fire Point Tester Standard methods ASTM D92, ISO 2592, JIS K 2265-4, AASHTO T48, FTM 791-1103, IP 36, GOST 4333 Benefits at a Glance ``Integrated fire-extinguishing system automatically controlled or manually released (requires N 2 or CO 2 gas) ``The One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, stirrer, igniter and detector contacts ``A multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth ``Memory for 1000 tests, 20 operators, 100 sample names ``Statistical analysis (Min, Max, Mean, Repeatability) ``Data handling via USB stick for import into Excel or to LIMS Benefits at a Glance ``Memory for 1000 tests, 20 operators, 100 sample names, 21 test methods ``Statistical analysis (Min, Max, Mean, Repeatability) ``Measures the flash point of silicone samples without any problems ``Automatically lights up the test flame, relights it by an electric igniter and suppresses the gas source at the end of the test

Versatility by Options PMA 4 SC Sample Changer The Pensky-Martens closed-cup tester with sample changer measures the flash point of up to 12 samples automatically. PMA 4 SC is suitable for flammability applications on both biodiesel and biodiesel blended fuels along with diesel, heating oil and kerosene. It is also commonly used for other potentially flammable liquids. PMA 4 SC On-site calibration The calibration set is a mandatory accessory for all flash point tester calibration programs. It is used to calibrate the sample temperature sensor Pt100 dynamically against certified liquid-in-glass thermometers. The on-site calibration feature is very cost-effective and available at any time. ABA 4 TAG 4 PMA 5 PMA 4 SC CLA 5 Multi-detector functionality check The holding device for multi-detectors (PMA and ABA/TAG) allows you to check the functionality of your Pt100 and thermo-couple and enables calibration services to calibrate the Pt100. The diagnosis function of the sensitive sensors prevents unnecessary service costs in case of unexpected measurements. ABA 4 TAG 4 PMA 5 PMA 4 SC Small-scale samples The test insert millicup for small sample volumes between 2 ml to 15 ml allows the application of the flash point tester for small sample quantities. A reduced sample volume of 80 % is valuable for the cosmetics industry and also the R&D field. ABA 4 TAG 4 PMA 5 PMA 4 SC Versatility by stainless steel The test insert is a stainless steel alternative to the 75 ml standard type made of brass. The multi-detector combines the flash point detector with a sturdy stainless steel temperature probe. Although not in compliance with official standards it extends the spectrum of samples. ABA 4 TAG 4 PMA 5 PMA 4 SC

High Throughput FPPNet Software for automatic flash point testers The software serves the purpose of reading and evaluating test data as well as controlling the automatic flash point testers PMA 5, CLA 5, ABA 4, TAG 4, PMA 4 SC (sample changer version) and their previous models (PMA 4, CLA 4). It is easy to operate, with self explanatory menus.the flash point tester is connected to the PC-RS232 interface by using a null modem cable or the USB port. Benefits at a Glance ``Monitoring of real-time test progress on the PC screen ``Traceable documentation of all parameter adjustments ``Graphical display of the sample temperature, heater temperature and heating rate Test procedures for the following flash point test methods: Pensky Martens ASTM D93-A+B+C, ISO 2719-A+B+C, JIS K 2265 Cleveland ASTM D92, ISO 2529, JIS K 2265 Abel ISO 1516, ISO 1523, ISO 13736 Tag ASTM D56, ASTM D3934, ASTM D3941 User-defined programs Can differ from standard test methods Operating system: MS Windows XP SP3 Vista Windows 7 Multi-detector ensures full conformity with ASTM standard requirements As clearly stated in the ASTM standards for closed-cup flash point testing, e.g. ASTM D 93-07, the flash point values are a function of the apparatus design and can therefore not be obtained by different test methods, or with a different test apparatus. Only the Anton Paar closed-cup flash point testers PMA 5, ABA 4, TAG 4 strictly follow these technical specifications without any constructive deviation such as additional openings in the lid for placing a flash point detector. The solution is the Anton Paar multi-detector which combines the flash point detector and the temperature probe in a solid housing.

Specifications Technical specifications Test programs Abel flash point: ISO 13736, IP 170 Equilibrium procedures: ISO 1523, IP 492, EN 924 ISO 1516, IP 491 Optional Abel-Pensky: DIN 51755-1 2 individually designable test programs Tag flash point: ASTM D56, FTM 791-1101 Equilibrium procedures: ASTM D3941, ISO 1523, IP 492, EN 924 ASTM D3934, ISO 1516, IP 491 2 individually designable test programs Operation Configuration ABA 4 (air-cooled) ABA 4 (liquid-cooled) TAG 4 (air-cooled) TAG 4 (liquid-cooled) Application range ( C/ F selectable) 10 C to 110 C -30 C to 110 C 10 C to 110 C -30 C to 110 C Ignition type Gas and electric (interchangeable) Gas and electric (interchangeable) Stirring speed According to method or user-defined Heating rate According to method or user-defined According to method or user-defined Cooling by Peltier elements By built-in fan With tap water or a lowcost circulation cooler By built-in fan With tap water or a lowcost circulation cooler Barometric pressure correction Flash point is automatically corrected to barometric pressure Flash point is automatically corrected to barometric pressure Flash detection Thermocouple Thermocouple Sample temperature Pt100 Pt100 Test place 1 (standardized test insert with multi-detector included) 1 (standardized test insert with multi-detector included) Safety ABA 4 TAG 4 Overheat protection, automatic shut-off Detects a "flash" outside the cup Test aborted by warning message Overheat protection, automatic shut-off Detects a "flash" outside the cup Test aborted by warning message Calibration User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass IP-thermometer or static by reference resistors Barometric-pressure-sensor calibration User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTMthermometer or static by reference resistors Barometric-pressure-sensor calibration Handling Splash-proof membrane touch-key panel with large LCD Space-saving footprint Splash-proof membrane touch-key panel with large LCD Space-saving footprint Documentation Memory 99 tests 99 tests Interfaces 2x RS232 2x RS232 Display Splash-proof membrane touch-key panel with large LCD Splash-proof membrane touch-key panel with large LCD Requirements and dimensions Power supply 115 V/230 V, 50 Hz/60 Hz, 180 W 115 V/230 V, 50 Hz/60 Hz, 150 W 115 V/230 V, 50 Hz/60 Hz, 180 W 115 V/230 V, 50 Hz/60 Hz, 150 W Gas supply 50 mbar of propane or butane 50 mbar of propane or butane Dimensions 230 mm x 470 mm x 470 mm (W x D x H) 230 mm x 470 mm x 470 mm (W x D x H) Weight net 8 kg 8 kg

PMA 5 CLA 5 Technical specifications Test programs ASTM D93 A+B+C ISO 2719 A+B+C JIS 2265-3 A+B IP 34 A+B GOST R EN ISO 2719 15 individually designable test programs ASTM D92 ISO 2592 JIS K 2265-4 AASHTO T48 FTM 791-1103 IP 36 GOST 4333 10 individually designable test programs Operation Configuration Application range Up to 405 C Up to 400 C ( C/ F selectable) Ignition type Gas and electric (interchangeable) Gas Stirring speed According to method or user-defined Heating rate According to method or user-defined According to methods, programmable and pre-heat mode Cooling Built-in forced air (fan) Built-in forced air (fan) Barometric pressure correction Flash point is automatically corrected to barometric pressure Flash point is automatically corrected to barometric pressure Flash detection Thermocouple Ionization detector Sample temperature Pt100 Pt100 Test place 1 (standardized test insert with multi-detector included) 1 (standardized test insert) Safety Calibration Overheat protection, automatic shut-off Automated fireextinguishing system A potential-free alarm relay contact is also available to connect a fire suppression or remote alarm system Password protection Detects a "flash" outside the cup Test aborted by warning message User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTM-thermometer or against up to 21 user-defined temperature points from an external calibration certificate or static by reference resistors Barometric-pressure-sensor calibration Overheat protection, automatic shut-off Test aborted by warning message User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTM-thermometer or against up to 21 user-defined temperature points from an external calibration certificate or static by reference resistors Barometric-pressure-sensor calibration Handling Splash-proof membrane key panel with color display Jog shuttle with LED indication for input of test parameters, sample name and program selection Selection of C or F, as well as further test parameters Multilanguage user support (English, German, French) Progress of test displayed in different colors (user-defined) The jog shuttle and 4 softkeys underneath the display are used for operation Splash-proof membrane key panel with color display Jog shuttle with LED indication for input of test parameters, sample name and program selection Selection of C or F, as well as further test parameters Multilanguage user support (English, German, French) Progress of test displayed in different colors (user-defined) The jog shuttle and 4 softkeys underneath the display are used for operation Documentation Memory 1000 tests, 20 operator names and 100 samples 1000 tests, 20 operator names and 100 samples Statistics Mean, Min, Max, Repeatability Mean, Min, Max, Repeatability Interfaces 3x USB, 1x RS232, 1x LAN 3x USB, 1x RS232, 1x LAN Input options Optional keyboard/bar code reader Optional keyboard/bar code reader Display 5.7'' QVGA color; real-time measurement displayed 5.7'' QVGA color; real-time measurement displayed Requirements and dimensions Power supply 115/230 V, 50/60 Hz, 1000 W 115 V/230 V, 50 Hz/60 Hz, 600 W Gas supply Test flame: 50 mbar of propane or butane Fire extinguisher: 50 mbar of propane or butane 6 bar to 12 bar of nitrogen or carbon dioxide Dimensions 230 mm x 410 mm x 460 mm (W x D x H) 230 mm x 390 mm x 460 mm (W x D x H) Weight net 14 kg 12 kg Technical specifications of PMA 4 SC: Next page

Specifications PMA 4 SC Standard Methods ASTM D93 A+B+C, ISO 2719 A+B+C, JIS K 2265-3, IP 34 A+B Technical Specifications Application range Up to 405 C ( C/ F selectable) Test places 1 to 12 Ignition Heating Stirring Cooling Flash detection Sample temperature Barometric pressure correction Safety Interfaces Gas supply Power supply Gas and electric (interchangeable) According to method or user-defined According to method or user-defined Built-in forced air (fan) Thermocouple Pt100 Automatic correction Overheat protection, automatic shut-off, fire-extinguishing system, detects a "flash" outside the cup, test aborted by warning message Depending on PC configuration ``Test flame: 50 mbar of propane or butane ``Fire extinguisher: 6 bar to 12 bar of nitrogen or carbon dioxide 115 V/230 V, 50 Hz/60 Hz, 1000 W Dimensions 900 mm x 490 mm x 620 mm (W x D x H) Weight 35 kg

Go Beyond the Conventional Scope Extended Measuring Range for ABA 4 and TAG 4 Thanks to state-of-the-art Peltier element technology two cooling versions are available for ABA 4 and TAG 4: an economical version with internal air cooling for flash point measurements from +10 C to +110 C and and a low-temperature version with a low-cost external liquid cooling from -30 C to +110 C. This enables you to go beyond the conventional scope of the method. ABA 4 and TAG 4 are suitable for flash point applications on jet fuels, solvents, chemicals etc. and give you the choice between gas or electric ignition as well as conducting both static and dynamic Pt100 sample calibration. ABA 4 and TAG 4 also provide automatic barometric pressure correction and thermocouple flash point detection. More applications High safety: Versatile CLA 5 Only the Anton Paar Cleveland open-cup (COC) flash and fire point tester CLA 5 measures flash points of silicone samples without any problems. CLA 5 is also commonly used for flash and fire point applications of lubricants or bituminous material. It automatically measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning. For skin forming bituminous materials, ease of use is enhanced by an optional automatic skin removal kit. CLA 5 meets the highest safety standards. In addition to overheat protection and automatic heat shut-off during the test, an optional stainless steel sample temperature sensor Pt100 increases operating safety.

2017 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. XPTIP005EN-C