premier product range

Similar documents
Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Jabulani Ngobese KA & New Technology Development Manager Elster Kent Metering (Pty) Ltd South Africa

EM DC Multi-Function DC Energy Meter

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Acuvim-L Series. Multifunction Power Meter. Max & Min

DGC-2020 DIGITAL GENSET CONTROLLER

AEL.TF.32 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS

OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Three phase Direct Connection Smart Meter s Technical Specification

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

MULTICAL 6M2. Data sheet

INTECH Micro 2300-RTD6

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

MagFlux Q 8200 Series

COUNTIS E22 Three-phase energy meter Direct - 80 A

AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS

USER MANUAL DDM30SC SINGLE PHASE DIN-RAIL KWH METER USER MANUAL TG ELECTRONICS. Manufactering company HUABANG OEM:101387

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

WZMC-402 Ultrasonic Apartment Energy Meters

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Energy Storage System for Home

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical Specificaions. kwh Energy Meter

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Measuring capsule heat meter G54 / G55

SonoMeter 30 Energy Meters

L kw Distributed Energy Storage System Unit (SU50)

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

USERS MANUAL MCD REMOTE OPERATOR

Power+ CLASSIC. 20/30 kva, 3x208 Vac

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

SMART METERING.

SonoMeter 30 Energy Meters

Fluidic Oscillation Compact Heat Meter

U n i n t e r r u p t i b l e P o w e r S y s t e m

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

825-P Modular Protection System for motors Specification Guide

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

AuCom - Soft Starters

OPERATING INSTRUCTIONS MCP-MT1

Digital Time Switches

DGC-2020 DIGITAL GENSET CONTROLLER

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Three Phase UPS Systems Range: 10 to 500kVA

Aurora Single Phase Emergency Lighting Inverters

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

PSW102 type CT powered protection unit

Power Line Communications Metering Systems. RSM-5c RSM-5. Installation Manual

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Language specific user manuals are available on

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

tprime TM Series 280T

Q pole Pole Mounted Capacitor System

Residential Energy Storage System SH 5K

Rail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

Heat Meter Integrator

Superstatic 749. Fluidic Oscillation Compact Heat Meter

ITW GSE 2400 COMPACT GPU kva solid-state GPU

1000 KW / 1250 KVA POWERED by

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems.

Compact Static Heat Meter of High-Tech Composite

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Energy Monitoring (Plug-in to II *1 )

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Turbidity and Suspended Solids Transmitter

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

3 Uninterruptible Power Systems

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

ULTRASONIC HEAT METER

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

1-Phase Intelligent ATS

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

PLATINUM SERIES SWITCHBOARD METERS

TECHNICAL DESCRIPTION OF BATTERY DISCHARGE TEST UNIT MODEL COMPOWER CP3025/12DL V.2.0

HYDRUS ULTRASONIC METER

Superstatic 440. Static Heat- and Cooling Meter. Application

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Range of Ultrasonic Flowmeters.

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Catch Eco Range : Technical Specification Sheet

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Transcription:

premier product range PREMIER is a full four quadrant metering platform for use in deregulated markets where data storage, multi utility and AMR facilities are important. PREMIER provides solutions from basic tariff metering through to revenue protection applications. PREMIER is a cost effective solution for CT and CT/VT applications and provides a single metering platform for accuracy from class 1.0s through to class 0.2s. Available with up to 4 outputs and 3 inputs, load survey storage options of up to 440 parameter days of data including 2 input counters, time of use and maximum demand recording. Two local communications ports are provided on the front of the meter with additional RS232 port under the terminal cover for AMR. PREMIER is UK CoP5 approved. PREMIER+ features time of use and maximum demand metering and up to 350 days of load survey storage with a fast reading protocol to facilitate rapid transfer of data to minimise read times. Two communications ports are provided for local meter reading and an additional RS232 port under the terminal cover for AMR. PREMIER+ also includes up to 4 outputs and 3 inputs. PREMIER+ complies to IEC1036 and AS1284.5. PREMIER RP features sophisticated intelligent revenue protection facilities for installations where theft and fraud are prevalent. The meter will detect and log tampers such as current reversal, CT open and short circuit, voltage and current imbalance and magnetic influence. PREMIER RP also offers load survey, time of use and maximum demand recording and includes options for up two communication ports. An optional inductive power up interface to allow reading when off power is also available. The Intelligent Metering Company

PRI House, Moorside Road, Winchester, Hampshire, SO23 7RX, England. Telephone: +44 (0) 1962 840048 Fax: +44 (0) 1962 841046 Internet: www.pri.co.uk Email: meters@pri.co.uk Issue No. 9600-1010-A DCR 5077

premier The Premier offers: Full four quadrant metering 5 main energy registers Load survey recording of: 160 days of 1 channel 30 minute data 80 days of 2 channel 30 minute data 53 days of 3 channel 30 minute data 40 days of 4 channel 30 minute data 32 days of 5 channel 30 minute data N.B Optional 64k memory increases the data storage typically by a factor of three Load survey integration periods of 5, 15, 30 or 60 minutes 16 time of use and 8 maximum demand registers, user configurable for seasonal control over all 5 energy types Maximum demand integration periods of 5, 15, 30 or 60 minutes Up to 4 user configurable outputs Up to 3 user configurable inputs 9600 baud PACT communication port 9600 baud modem port under the terminal cover 1200 baud IEC1107 communication port Ofgem approved to IEC1036 and IEC687 Dimensions 66.70 174.00 166.90 196.40 150.00 14.95 250.00 The Intelligent Metering Company

premier technical specification Premier Technical Specification ELECTRICAL Build options available for: CT Connected 230V phase to neutral, 3 element 3 phase 4 wire. CT/VT connected 100/110V phase to phase, 2 element 3 phase 3 wire. CT /VT connected 57.7/63.5V phase to neutral, 3 element 3 phase 4 wire, 2 phase 3 phase 4 wire, 1 phase 3 wire, 1 phase 2 wire. CURRENT In 5A 1A Imax 6A 1.2A BURDEN Current circuit Voltage circuit METROLOGICAL IEC 1036/687 Class Class 2.0S, 1.0S, 0.5S, 0.2S MECHANICAL Dimensions Enclosure Material Degree of Protection Flame Retardation Weight (approx.) MAINS FREQUENCY DATA RETENTION DISPLAY Image Area W.176 X H.250 X D.67 mm ABS/Polycarbonate IP51 UL 94 V0 1 kg 45-65Hz 10 years minimum (unpowered) LCD 75 x 17mm CLOCK & CALENDAR Normal Power Source Mains supply RTC Backup Source Lithium battery or super cap. Battery Life (typical) 10 years Min Shelf Life (typical) 3 years Wiring Diagram ACTIVITY INDICATOR Meter Constant EU DIRECTIVES ENVIRONMENTAL* Operating Temperature Storage Temperature Operating Humidity TERMINALS High intensity red LED, kwh consumed. 800 flashed per kwh for 230V 3 phase 4 wire CT connected 100A (scaled for other ratios and voltages). The product complies with 89/336/EEC Electromagnetic Compatibility Directive, amended by 92/31/EEC, by meeting BS EN 61036:1997. -10 C to +45 C -25 C to +70 C Up to 95% non-condensing * requirements for specific countries available on request Two screws per conductor. Suitable for cable sizes from 2.5mm 2 to 5.0mm 2 PULSED INPUTS AND OUTPUTS Premier can be supplied in various hardware builds with up to 7 input/output channels, for example: 4 outputs, 0 inputs 4 outputs, 3 inputs The CLEM and tariff files determine the exact functionality of inputs and outputs. The hardware-build determines which inputs and outputs are physically provided. PULSED INPUTS Up to two external parameters can be counted, with the capability to store values as load survey parameters. Up to two external signals can be used to synchronise time-base or switch time-of-use registers. Inputs are rated for 9-40 Vdc operation. PULSED OUTPUTS Up to four outputs can be used to indicate energy consumption, active rate, change of rate, end of demand period, or to indicate that a particular rate is active. COMMUNICATIONS Local Interrogation ports PACT and 1107 ports Remote Interrogation Optically isolated RS232 port port under the terminal cover Protocol PACT at speeds from 1200-9600 baud Neutral Wiring Configuration for P3T 3 Phase 4 Wire CT connected 230V Wiring Configuration for P3M 3 Phase 4 Wire CT/VTconnected 63.5V Wiring Configuration for P3V 3 Phase 3 Wire CT/VTconnected 110V PRI House, Moorside Road, Winchester, Hampshire, SO23 7RX, England. Telephone: +44 (0) 1962 840048 Fax: +44 (0) 1962 841046 Internet: www.pri.co.uk Email: meters@pri.co.uk Issue No. 9600-1011-A DCR 5077

premier+ The Premier+ offers: Full four quadrant metering 5 main energy registers Load survey recording of: 350 days of 1 channel 30 minute data 175 days of 2 channel 30 minute data 116 days of 3 channel 30 minute data 87 days of 4 channel 30 minute data 70 days of 5 channel 30 minute data Load survey integration periods of 15, 30 or 60 minutes 8 time of use and 4 maximum demand registers, user configurable for seasonal control over all 5 energy types Maximum demand integration periods of 5, 15, 30 or 60 minutes Up to 4 user configurable outputs Up to 3 user configurable inputs 9600 baud ANSI communication port 9600 baud modem port under the terminal cover 1200 baud sealable PACT port Fast download of survey data - 90 days of 1 channel 30 minute data in less than 30 seconds IP53 rated 10kV impulse withstand Type approved to IEC1036, IEC687 and AS1284 parts 5 and 9 Dimensions 66.70 174.00 166.90 196.40 150.00 14.95 250.00 The Intelligent Metering Company

premier+ technical specification Premier+ Technical Specification ELECTRICAL Wiring configurations CT Connected 240V or 230V phase to neutral, 3 element 3 phase 4 wire. CT/VT connected 100/110V phase to phase, 2 element 3 phase 3 wire. CT /VT connected 57.7/63.5V phase to neutral, 3 element 3 phase 4 wire, 2 phase 3 phase 4 wire, 1 phase 3 wire, 1 phase 2 wire. CURRENT In 5A 1A 5A Imax 20A 1.2A 6A BURDEN Current circuits Voltage circuits METROLOGICAL IEC 1036/687, AS1284.5, AS1284.9 Class 2.0S, 1.0S, 0.5S MECHANICAL Dimensions (approx.) Enclosure Material Degree of Protection Flame Retardation Weight (approx.) MAINS FREQUENCY DATA RETENTION DISPLAY Image Area W.176 X H.250 X D.67 mm ABS/Polycarbonate IP53 UL 94 V0 1 kg 45-65Hz 10 years minimum (unpowered) LCD 75 x 17mm CLOCK & CALENDAR Normal Power Source Mains supply RTC Backup Source Lithium battery or super cap. Battery Life (typical) 10 years Min. Shelf Life (typical) 3 years ACTIVITY INDICATOR Meter Constant EU DIRECTIVES High intensity red LED, kwh consumed. 800 flashes per kwh for 240V 3 phase 4 wire CT connected 100A (scaled for other ratios and voltages). The product complies with 89/336/EEC Electromagnetic Compatibility Directive, amended by 92/31/EEC, by meeting BS EN 61036:1997. ENVIRONMENTAL Operating Temperature -10 C to +60 C Storage Temperature -25 C to +80 C Operating Humidity Up to 95% non-condensing TERMINALS Two screws per conductor. Suitable for cable sizes from 2.5mm 2 to 5.0mm 2 PULSED INPUTS AND OUTPUTS Premier can be supplied in various hardware builds with up to 7 input/output channels, for example: 4 outputs, 0 inputs 4 outputs, 3 inputs The CLEM and tariff files determine the exact functionality of inputs and outputs. The hardware-build determines which inputs and outputs are physically provided. PULSED INPUTS Up to two external parameters can be counted, with the capability to store values as load survey parameters. Up to two external signals can be used to synchronise time-base or switch time-of-use registers. Inputs are rated for 9-40Vdc operation. PULSED OUTPUTS Up to four outputs can be used to indicate energy consumption, active rate, change of rate, end of demand period, or to indicate that a particular rate is active. COMMUNICATIONS Local Interrogation ports PACT and ANSI ports Remote Optically isolated RS232 Interrogation port port under the terminal cover Protocol PACT at speeds from 1200-9600 baud Wiring Diagram Neutral Wiring Configuration for P3T 3 Phase 4 Wire CT connected 230V Wiring Configuration for P3M 3 Phase 4 Wire CT/VTconnected 63.5V Wiring Configuration for P3V 3 Phase 3 Wire CT/VTconnected 110V PRI House, Moorside Road, Winchester, Hampshire, SO23 7RX, England. Telephone: +44 (0) 1962 840048 Fax: +44 (0) 1962 841046 Internet: www.pri.co.uk Email: meters@pri.co.uk Issue No. 9600-1012-A DCR 5077

premier RP The Premier RP offers: Full four quadrant metering 5 main energy registers and 8 main registers for true import/export metering Advance tamper detection features including: Missing voltage, invalid voltage, voltage unbalance, current reversal, current unbalance, current open circuit*, current short circuit* and abnormal magnetic influence *only available of 3p-4w meters Occurrence and restoration event logging with time and date stamp Snapshot taken of electrical values at time of occurrence and restoration including voltages, currents, powers factors 8 time of use and 2 maximum demand registers from the main energy registers, configurable for TOU and seasonal control Load Survey configurable for energy, voltages, currents, frequency or power factor Load Survey integration periods of 15, 30 and 60 minutes 1200 baud sealable PACT port Optional IEC1107 compatible communication port Inductively coupled external power pack for meter reading in the absence of supply (Build option) Up to 4 user configurable outputs via the optional top module Up to 2 user configurable inputs via the optional top module Type approved to IEC1036 and IEC687 66.70 175.00 Dimensions 166.90 150.00 250.00 57.26 196.40 14.95 The Intelligent Metering Company

premier RP technical specification Premier RP Technical Specification ELECTRICAL Wiring configurations CT Connected 240V phase to neutral, 3 element 3 phase 4 wire. CT/VT connected 100/110V phase to phase, 2 element 3 phase 3 wire. CT /VT connected 57.7/63.5V phase to neutral, 3 element 3 phase 4 wire. CURRENT In 5A 1A Imax 10A 2A BURDEN Current circuits Voltage circuits METROLOGICAL <2VA/Watt per phase IEC 1036/687 Class 2.0S, 1.0S, 0.5S MECHANICAL Dimensions (approx.) W.176 X H.250 X D.67 mm Enclosure Material ABS/Polycarbonate Degree of Protection IP51 Flame Retardation UL 94 V0 Weight (approx.) 1.65 kg (with optional top module) ACTIVITY INDICATOR Meter Constant EU DIRECTIVES High intensity red LED, kwh/kvarh/kvah Meter constant depends on meter scaling values (i.e. CT and VT ratios) The product complies with 89/336/EEC Electromagnetic Compatibility Directive, amended by 92/31/EEC, by meeting BS EN 61036:1997. ENVIRONMENTAL* Operating Temperature -10 C to +45 C Storage Temperature -25 C to +70 C Operating Humidity Up to 95% non-condensing * requirements for specific countries available on request TERMINALS CLOCK & CALENDAR Normal Power Source RTC Backup Source Battery Life (typical) Min. Shelf Life (typical) DISPLAY Image Area DATA RETENTION Two screws per cable. Suitable for cable sizes from 2.5mm 2 to 5.0mm 2 Mains supply Lithium battery or super cap. 10 years 3 years LCD 75 x 17mm 10 years minimum (unpowered) COMMUNICATIONS Local Interrogation ports PACT and ANSI or 1107 ports MAINS FREQUENCY 45-55Hz Top Module Technical Specification COMMUNICATIONS Remote Interrogation port Optically isolated RS232/RS485 port Protocol PACT at speeds from 1200-9600 baud INPUTS AND OUTPUTS Options available Wiring Diagram 4 outputs and 1 input 3 outputs and 2 inputs PULSED OUTPUTS Up to four outputs can be used to indicate energy consumption, active rate, change of rate, end of demand period, or to indicate that a particular rate is active. PULSED INPUTS Up to two inputs can either be counted and stored as register, survey data, used to synchronise the meter time-base or switch time-of-use registers. Inputs are rated for 9-40Vdc operation. Optional 230 VAC available. Neutral Wiring Configuration for P3T 3 Phase 4 Wire CT connected 230V Wiring Configuration for P3M 3 Phase 4 Wire CT/VTconnected 63.5V Wiring Configuration for P3V 3 Phase 3 Wire CT/VTconnected 110V PRI House, Moorside Road, Winchester, Hampshire, SO23 7RX, England. Telephone: +44 (0) 1962 840048 Fax: +44 (0) 1962 841046 Internet: www.pri.co.uk Email: meters@pri.co.uk Issue No. 9600-1013-A DCR 5077