Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Similar documents
Inductive conductivity meter

Inductive conductivity meter

Positive displacement flowmeter

INSERTION flowmeter with paddle wheel, ELEMENT design

Digital ph transmitter

Digital ph transmitter

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control

Positive displacement batch controller

INSERTION flow sensor for continuous flow measurement

Paddle-wheel flow controller for On/Off control

Positive displacement flowmeter for continuous flow measurement

Insertion magnetic inductive flowmeter

Operating Instructions (from serial number 3000)

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

INSERTION Adaptor for analysis

Signet 2551 Magmeter Flow Sensor

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Electrical position feedback for actuator sizes Ø mm

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Type 8222 ELEMENT. Operating Instructions. Bedienungsanleitung Manuel d utilisation. Conductivity meter Leitfähigkeits-Messgerät Conductivimètre

Pneumatic control unit for decentralized automation of ELEMENT process valves

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

2100 Turbine Flow Sensor

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Probe holders for analytical probes

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Signet Conductivity/Resistivity Electrodes

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

High-speed detection even a little liquid leak

Level Measurement Point level measurement - RF Capacitance switches

Series ITV1000/2000/3000

SIGNET 7002 Vortex Flow Sensor ENGLISH

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Signet Conductivity/Resistivity Electrodes

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Angle-Seat Valve System for on/off control. Type 8801/2100 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system

Conductivity Measuring Sensor InduMax H CLS 52

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLOWX3 F3.60M.S Insertion Magmeter

Metso Conductivity for sensor series 9400 and 9500

Model DFX Doppler ultrasonic flow meter

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Pressure transmitters for heavy duty applications Type MBS 3250

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Turbotron // VTH15, VTM15, VTP15, VTI15

Conductivity Measuring Cells ConduMax W CLS 19

2-Color Display High-Precision Digital Pressure Switch

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

2/2 way Angle-Seat Valve for medium up to C, DN15-50

Model Pressure range ON/OFF output Linear output

2-Color Display High-Precision Digital Pressure Switch

EX-F70 SERIES EX-F60 SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Series 10-ZSE40A(F)/10-ISE40A

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

G2 Industrial Grade Meters

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

MEASUREMENT AND INSTRUMENTATION FLS

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Chapter Page. 1 Introduction Description 1

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

Inductive Proximity Sensor

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Pressure transmitters for heavy duty applications MBS 3200 and 3250

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Differential Pressure Sensor

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Octave Water Meter Installation Manual

MagFlux Q 8200 Series

Flow measurement FlexFlow PF20H Hygienic flow sensor

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Servo-operated 2/2-way solenoid valves Type EV220A

mass flowmeter for compressed air

Inductive Proximity Sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

better measurement Simply a question of

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PXT-K Series. Pressure Transmitters Section 05

Signet 7000/7001 Vortex Flow Sensors * *

Pressure sensors - Nautilus

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Transcription:

Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants for covering a wide measuring range Diagnostic functions Type 6642 Type 8802-DF Type 2030 Type 8644 Type 8620 PLC Solenoid valve Diaphragm valve with control unit On/Off Diaphragm valve Valve islands Cooling Tower or boiler chemistry controller The Bürkert compact meter Type is designed for measuring the conductivity of fluids. The conductivity meter consists of a sensor, plugged-in and pined to an enclosure with cover, containing the electronic module and a removable display. The sensor comprises a cell with two electrodes and a Pt1000 temperature probe. The sensor itself is available with three different cell constants C, these with C=0.01 or 0.1 are fitted with stainless steel electrodes and those with C=1.0 are fitted with graphite electrodes. The conductivity meter can operate independent of the display but it will be required for programming the device (i.e. selection of sensor cell constant, language, measuring range, engineering units, calibration...) and also for visualizing continuously the measured and processed data. The device Type is available: - with three fully programmable outputs: two transistor and one 2-wire 4... 20 ma current outputs - with four fully programmable outputs: two transistor and two 3-wire 4... 20 ma current outputs. Technical data (Pipe + conductivity meter) Pipe diameter Conductivity measurement Measuring range Resolution Accuracy Temperature measurement Measuring range Internal resolution Accuracy Minimal temperature range Temperature compensation Medium temperature with G1½ PVC nut connection with G1½ nut connection Fluid pressure max Environment Ambient temperature Relative humidity DN25 to DN110 (DN<25 with reduction) 0.05 S/cm... 10 ms/cm 1 ns/cm ±3% of measured value -40 to +130 C (-40 to 266 F) 0.1 C (0.18 F) ±1 C (1.8 F) 10 C (i.e 10 to 20 C (50 to 68 F) corresponding to 4... 20 ma) none or according to a predefined graph (NACl or ultra pure ) or according to a graph defined especially for your process 0 to 50 C (32 to 122 F) -20 to 100 C (-4 to 212 F) restricted by the used adaptor restriction with adaptor S022 in: - PVC: 0 to 50 C (32 to 122 F) - PP: 0 to 80 C (32 to 176 F) - Metal: -20 to 100 C (-4 to 212 F) PN16 (232 PSI) (see Pressure/Temperature chart) -10 to +60 C (14 to 140 F) (operating and storage) 85%, without condensation The electronics of Type converts the measured signal, displays different values in different physical units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors.

Electrical data Materials view Power supply Current consumption with sensor Reversed polarity of DC Voltage peak Short circuit Output Transistor Current 14-36 V DC, filtered and regulated 12-36 V DC, filtered and regulated 1 A (with the 2 transistors loads) 25 ma (at 14 V DC without transistors load, with current loop) 5 ma (at 12 V DC without transistors load, without current loop) Protected Protected Protected for transistor outputs configurable as sourcing or sinking (respectively both as PNP or NPN), open collector max. 700 ma, 0.5 A max. per transistor if the 2 transistor outputs are wired output NPN: 0.2-36 V DC output PNP: V+ power supply 4... 20 ma programmable as sourcing or sinking, Brass, nickel plated Stainless steel PPS PC EPDM PPS EPDM PPS PVC or max. loop impedance: 1100 at 36 V DC; 610 at 24 V DC; 180 at 14 V DC Response time (10% - 90%) configurable in the same mode as transistor: sourcing or sinking, max. loop impedance: 1100 at 36 V DC; 610 at 24 V DC; 100 at 12 V DC 150 ms (standard) Graphite (C=1) Pt probe Stainless steel 316 Ti (C=1) General data Compatibility Any pipe which are fitted out with Bürkert adaptor S022 (see separate data sheet) Stainless steel 316 Ti (C=0.1 or 0.01) Materials Housing / cover Seals / Screws Fixed connector mounting plate Fixed connector Display / navigation key Nut Wetted part materials Conductivity sensor Electrode Temperature sensor See exploded view, opposite Stainless steel 1.4561, PPS / PC EPDM / Stainless steel Stainless steel Brass nickel plated PC / PBT PVC or, stainless steel 1.4571 (316Ti) Stainless steel 1.4571 (316Ti ) for cell constant C=0.01 or C=0.1 or graphite for cell constant C=1.0 Pt1000 (316Ti) integrated in the sensor Display (accessories) Grey dot matrix 128x64 with backlighting Electrical connections Connection cable 1x 5-pin M12, 1x 5-pin M12 male + 1x 5-pin M12 fes Shielded cable Standards, directives and approvals Protection class Standard and directives EMC Pressure Vibration / Shock Approvals for US and Canada IP65 and IP67 with M12 cable plug mounted and tightened and cover fully screwed down EN 61000-6-2, EN 61000-6-3 Complying with article 3 of 3 from 97/23/CE directive.* EN 60068-2-6 / EN 60068-2-27 61010-1 + CAN/CSA-C22 No.61010-1 * For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.b Fluid group 2, 1.3.b Conditions Only DN 25 DN 32, or DN > 32 and PN*DN 1000 DN 25, or DN > 25 and PN*DN 2000 DN 125

Pressure/Temperature chart Application range of a conductivity meter: A : with nut B : with PVC nut The measures have been made at an ambient temperature of 60 C. Pressure (bar) Application range of a conductivity meter with PVC nut with S022 adaptor P (bar) P (bar) Application range of a conductivity meter with nut with S022 adaptor Principle of operation Conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (E.G. dissolved salt or acids). In order to measure conductivity two electrodes are used which are set at a fixed distance apart and with a known specified surface. An AC voltage source is connected to the electrodes. The measured current is a direct function of the conductivity of the solution. The conductivity meter is a two-wire device (single meter version) or a three-wire device (dual meter version) and requires a power supply of 14 V DC (single meter version) or 12 V DC (dual meter version) up to 36 V DC. The conductivity meter can be fitted with 3 different sensors with cell constants 0.01, 0.1 or 1.0. - C=0.1 C=0.01 C=1 The sensor is selected according to the measuring range and medium by using the table opposite. ultra-pure pure industrial sewage -

Installation The conductivity meter can be installed into any adaptor with G1½ external threaded sensor connection by just fixing the main nut. Select and install the required adaptor onto the pipe according to specific requirements of the sensor and material (temperature and pressure). For mounting on a tank or direct mounting on a pipe (DN100 and DN110), an adaptor with a G1½ external threaded sensor connection must be used. Install cautiously the device on the fitting. It can be installed in any position (prefer A mounting to install a with sensor C=0.1 or C=0.01). In order to get reliable measurement air bubbles must be avoided. Please ensure that the mounting location provides a continuous and complete immersion of the sensor in the flow stream. A The device must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. Dimensions [mm] of conductivity meter Type

Ordering information for compact conductivity meter Type A complete compact conductivity meter Type consists of a compact conductivity meter Type, a removable display/ configuration module and a Bürkert INSERTION adaptor Type S022 (with G1½ external threaded sensor connection). The following information is necessary for the selection of a complete device: Item no. of the desired conductivity meter Type (see ordering chart on p. 6) Item no. of the a removable display/configuration module (see accessories ordering chart on p. 7) Item no. of the selected INSERTION adaptor Type S022 with G1½ external threaded sensor connection (see separate data sheet) You have to order two or three components. Attention! When you order devices without display, please take care that you also order at least one display module for the operation. Order no. of the removable display/configuration module, see ordering chart on p. 7 When you click on the orange box More info. below, you will come to our website for the resp. product where you can download the data sheet. Example Compact conductivity meter Type without display Removable display/configuration module Complete device for conductivity measurement Type + INSERTION adaptor Type S022 Fitting (example only)

Ordering chart for compact conductivity meter Type Conductivity meter Type Specifications Voltage supply Output Sensor version Nut material Electrical connection UL Approvals Item no. Compact conductivity meter without display 14-36 V DC 2 x transistors + 1 x 4... 20 ma C=0.01 PVC 5-pin M12 5-pin M12 No 559 618 562 394 No 559 620 562 396 C=0.1 PVC 5-pin M12 No 559 614 559 624 5-pin M12 No 559 616 559 626 C=1.0 PVC 5-pin M12 No 559 610 559 638 5-pin M12 No 559 612 559 622 12-36 V DC 2 x transistors + 2 x 4... 20 ma C=0.01 PVC 5-pin M12 male and 5-pin M12 fes No 559 619 562 395 5-pin M12 male and 5-pin M12 fes No 559 621 562 397 C=0.1 PVC 5-pin M12 male and 5-pin M12 fes No 559 615 559 625 5-pin M12 male and 5-pin M12 fes No 559 617 559 627 C=1.0 PVC 5-pin M12 male and 5-pin M12 fes No 559 611 559 639 5-pin M12 male and 5-pin M12 fes No 559 613 559 623 Note: Order separately (see accessories) - display/configuration module - M12 cable plugs (only female for 1 x 4... 20 ma, 1 male + 1 female for 2 x 4... 20 ma conductivity meter)

Ordering chart for accessories Description Item no. Removable display/configuration module (with instruction sheet) 559 168 Black blank cover with EPDM seal 560 948 Transparent cover with EPDM seal 561 843 Calibration solution, 300 ml, 5 S 440 015 Calibration solution, 300 ml, 15 S 440 016 Calibration solution, 300 ml, 100 S 440 017 Calibration solution, 300 ml, 706 S 440 018 Calibration solution, 300 ml, 1413 S 440 019 5-pin M12 female straight cable plug with plastic threaded locking ring, to be wired 917 116 5-pin M12 male straight cable plug with plastic threaded locking ring, to be wired 560 946 5-pin M12 female straight cable plug moulded on cable (2 m, shielded) 438 680 5-pin M12 male straight cable plug moulded on cable (2 m, shielded) 559 177 Interconnection possibilities with other Bürkert devices Type 8802-DF - Diaphragm valve with control unit PLC Type 8611 - Single channel controller Type 8620 - Cooling tower or Boiler chemistry controller Type - Compact conductivity meter Type S022 INSERTION adaptor FITTING (example only)