DIN Dual indication fuse links

Similar documents
XL Photovoltaic fuse links

500 and 690 V a.c. am NH fuse links

NH photovoltaic fuse links

500 Volts gg/gl NH Fuse links

Bussmann series NH photovoltaic fuse links

Safeclip BS fuse holders

Bussmann 7.2 kv Medium voltage fuse links

NH Bases BUSSMANN SERIES. Technical Data Product description. Standard features

Red Spot centre bolted tags fuse links

Bussmann series NH bases

Red Spot BS Industrial fuse holders

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

Bussmann series Red spot range offset bolted tags fuse links

Bussmann series Traction fuse links catalogue. Fuse links for railway applications

Bussmann series Product range overview. Leadership in fusible circuit protection solutions

RE SERIES RACK INSTALLATION GUIDE

Bussmann series photovoltaic application guide. Complete and reliable solar fusible circuit protection

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

NH DIN Dual Indication Fuse Links

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

CEAG GuideLed AT. Cost-eff icient and environment-friendly exit sign luminaire

Bussmann series Product range overview. Leadership in fusible circuit protection solutions

NH DIN Dual Indication Fuse Links

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

Transformers Flexible and Reliable

MEDIUM VOLTAGE DIN Fuse-Links

Accessories. For product data sheets, visit

Low-Peak 600V Class RK1

MEDIUM VOLTAGE DIN Fuse-Links

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Bussmann series modular fuse holders brochure. Compact modular fuse holders Products for Industrial, PV, IEC and UL applications

BH-1 modular fuse blocks, 700 V, 400 A

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Electric vehicle auxiliary fuses 500 Vdc, A

Photovoltaic System Overcurrent Protection

Leadership in Circuit Protection

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Photovoltaic System Overcurrent Protection

Leadership in Circuit Protection

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

RAPIDPLUS. high speed fuse links for semiconductors

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

RAPIDPLUS. high speed fuse links for semiconductors

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Class J modular ferrule and knifeblade fuse blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

Bussmann series NH catalogue. Leadership in circuit protection

Select 700V/ ysuk.com. The. Current limiting. acceptance. protection of. within a single. recognised (10 38 fuses) October 2013

Ferrule fuses. High Speed Fuses

NH Dual NHIndicator Fuse System Fuse System

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Semiconductor Fuses European Fuses

onlinecomponents.com

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

CUBEFuse. CUBEFuse catalog numbers (amps)

New material declaration documents and other engineering documents are available upon request.

Leadership in fusible circuit protection

Easy Multifunctional Safe

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Heating, Ventilation & Air Conditioning Industrial Cooling - Refrigeration Industrial Pumping & Ventilation

Coiltronics HCM1104 Series High current power inductors

Selection Guide. Control Circuit and Load Protection

Circuit Protection Solutions Product Guide

Easy Multifunctional Safe

Solar circuit protection application guide. Complete and reliable solar circuit protection

Compact Circuit Protector

N0N A 250V One-Time Class H Fuse

Synergy EN product information

Protistor size 120 gr 750VDC (IEC)

KLKD SERIES 10x38 FUSES

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Distribution & Control

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Technical specifications

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

High Speed Fuses. Section Contents Page

Coiltronics HCM0703 Series High current power inductors

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Starting Torque Limiter Type TCI (Soft Start)

Harmonization of IEC and North American Safety Standards

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

Complete and reliable solar circuit protection

6.3 mm reverse quick connect

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Semiconductor (AC) fuses

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Application Description

Compact Circuit Protector (CCP)

Low voltage, branch circuit fuses

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

C308F 3 mm x 8.4 mm fast-acting, ceramic tube fuses for hazardous applications

Transcription:

Supersedes November 2015 BUSSMANN SERIES Product description Eaton s Bussmann series DIN 43620 dual indicator fuse links protect UPS, soft starters, solid state relays, variable speed drives, rectifiers and inverters. Features Dual indicator system

Catalogue symbol 170MxxxxD Technical data Rated voltage: 690 V a.c. Rated current: 10 to 1600 A Breaking capacity: 200 ka RMS Sym Class of operation: gr (size 00 10 to 63 A) Total clearing I 2 t The total clearing I 2 t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I 2 t is found by multiplying the correction factor K, given as a function applied working voltage Eg (rms) ar others Standards/Approvals CE Designed and tested to IEC 60269 part 4 UL recognised (survival only) CSA RoHS compliant Packaging Size 000: 10 Size 00: 6 Size 1: 6 Size 2: 3 Size 3: 1 Arc voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Egrection factor, K, given as a function of applied working voltage Eg (rms) at a power factor of 15%. Power losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, lb, in % of the rated current. 2

Table 1. Technical Data Catalogue numbers Size Rated current RMS (Amps) I 2 t (A 2 sec) Minimum pre-arcing Clearing at 690 V a.c. Watts loss 170M1558D 000 10 4 27 2.5 170M1559D 16 7 51 4 170M1560D 20 11.5 82.5 5 170M1561D 25 19 140 6 170M1562D 32 40 285 7 170M1563D 40 65 490 8.5 170M1564D 50 115 815 9.5 170M1565D 63 215 1550 11.5 170M1566D 80 380 2700 15 170M1567D 100 695 4950 16.5 170M1568D 125 1180 8250 21.5 170M1569D 160 2300 16,500 25 170M1570D 200 4350 31,000 29.5 170M1571D 250 7900 56,000 35.5 170M1572D 00 315 12,000 84,500 45 170M3808D 1 40 40 285 4 170M3809D 50 78 550 4.5 170M3810D 63 120 850 6.5 170M3811D 80 185 1350 8.5 170M3812D 100 360 2600 10 170M3813D 125 550 3900 11 170M3814D 160 1150 8250 12 170M3815D 200 2300 16,500 12.5 170M3816D 250 4350 31,000 16 170M3817D 315 7300 52,000 20 170M3818D 350 10,000 73,000 21.5 170M3819D 400 16,000 115,000 23 170M4863D 450 21,500 155,000 26.5 170M4864D 500 27,000 190,000 28.5 170M4865D 550 33,500 240,000 33 170M4866D 630 48,500 345,000 37.5 170M4867D 700 69,500 495,000 39 Catalogue numbers Size Rated current RMS (Amps) I 2 t (A 2 sec) Minimum pre-arcing Clearing at 690 V a.c. Watts loss 170M5808D 2 400 11,000 79,000 29 170M5809D 450 16,000 115,000 32 170M5810D 500 21,500 155,000 34 170M5811D 550 29,000 215,000 36 170M5812D 630 41,000 295,000 42 170M5813D 700 60,500 430,000 43 170M5814D 800 86,000 610,000 48 170M5820D 900 125,000 895,000 52 170M5816D 1000 180,000 1,300,000 53 170M5817D 1100 245,000 1,750,000 56 170M6808D 3 500 14,000 99,500 43 170M6809D 550 19,500 140,000 44 170M6810D 630 31,000 220,000 45 170M6811D 700 45,000 320,000 46 170M6812D 800 69,500 490,000 48 170M6813D 900 100,000 720,000 50 170M6814D 1000 140,000 985,000 56 170M6892D 1100 190,000 1,400,000 57 170M8554D 1250 300,000 2,150,000 61 170M8555D 1400 380,000 2,700,000 70 170M8556D 1500 470,000 3,350,000 72 170M8557D 1600 585,000 4,150,000 74 * The rated current of this range has been given with copper conductors that have a current density of 1.3 A/mm 2 IEC 60269-1, the fuse links with a rated current higher than 125 A must be derated. Please contact Eaton s Bussmann series application engineers bulehighspeedtechnical for application assistance. 3

Dimensions - mm Size 000 Size 00 4

Dimensions - mm Size 1 Size 2 5

Dimensions - mm Size 3 6

Time-current curve Size 000 and 00 7

Time-current curve Size 1 8

Time-current curve Size 2 9

Time-current curve Size 3 10

Cut-off curve Size 000 and 00 Size 1 11

Cut-off curve Size 2 12

Cut-off curve Size 3 Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges, Switzerland Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton Electrical Products Limited Melton Road Burton-on-the-Wolds Leicestershire, LE12 5TH United Kingdom 2017 Eaton All Rights Reserved PDF only Publication No. 720101 October 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners.