Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Similar documents
Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Fusible Link (replaceable) Horizontal Mount

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fire Dampers Catalogue

CURTAIN TYPE FIRE DAMPER

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

table of contents PRODUCT SUMMARY 2

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635)

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Standard Installation Fire Damper Models: 319, 319(SS), D39

We make dampers easy for you!

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Installation, Operation and Maintenance Instructions

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Registers for spiral ducts

FAN POWERED TERMINAL UNITS

FIXED BLADE LOUVRE FACED CEILING DIFFUSER

Fire, Smoke, and Combination Fire Smoke Dampers

CEILING VENTILATOR ACCESSORIES 6393 Powers Avenue Jacksonville, Florida P: / F:

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

Smoke Dampers. Installation Instructions

MODEL 151B FIRE DAMPER

FAN POWERED TERMINAL UNITS

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Nobody delivers dampers and louvers faster!

Installation, Operation and Maintenance Manual

VD-1600 Series Volume Control Dampers

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

SMOKE DAMPER - CLASS F MODEL BMSD

Motorized Fire Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

BC 03. Fire Dampers FD-GB-30-AS LISTED

Inline & Sidewall Exhaust Fans

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Greenheck Product Category

Installation, Operation and Maintenance Manual

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

SINGLE DUCT TERMINAL UNITS 3000 SERIES

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Type 12 / 13 Enclosures

MULTI-BLADE FIRE DAMPERS

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

CATALOGUE DUCTS VENTILATION ELEMENTS. and. Production and sales office : Abrahámska 183; Malá Mača SLOVAKIA

Model VCD-20 3V CONTROL DAMPER

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

MULTI-BLADE FIRE DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Model FSD-331 Combination Fire Smoke Dampers

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide

SmartCom 3. Cabinet Heaters. Heat Exchanger models. Cabinet Heaters. VN/VD Vertical Heaters. HN/HD Horizontal Heaters. RN/RD Downflow Heaters

Variable Air Volume Dampers

FAN POWERED TERMINAL UNITS

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

W-VI Series - Internal Make-up Air Wall Canopy

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

Model FSD-212. Combination FIRE SMOKE DAMPERS

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

SINGLE DUCT AIR TERMINAL UNITS

Industrial Fans & Blowers

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Type 4 Panel Enclosures

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Anti-Pollution Ecological System

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

CONTROL SMOKE AND BALANCING DAMPERS

MODELS LCE/LCS, L2E/L2S, L3E/L3S

For installation into ductwork

Transcription:

Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a fire rated barrier made by an VC duct or transfer. The F can be installed vertically (F-V) or horizontally (F-) and is meant for static VC systems (fans turn off in a fire) only. Standard Construction: Frame Material lade Material and Type Standard 22 Gauge Galvanized Roll-formed Steel 22 Gauge Galvanized Roll-formed Steel Optional ------ ----- LISTINGS: UL 555 Listing: R8218 CSFM Listing: 3225-1721:0102 New York ME Listing: 79-03-M STNRS MET: NFP Standards: 80, 90, 92, 92 and 101 uilding Code Standard: ICC International uilding Code F 1-½ or 3 our, UL555 Listed R8218 Frame epth 3-11/16 2-3/18 (55) [see F-SL] 1-½ (38) [see F-V-SL] imensions ctual - 1/4 (6) ctual Closure Spring Stainless Steel ----- Fusible Link 165 (74 C) 212 (100 C) Mounting Vertical [F-V] orizontal [F-] UL our Rating 1-1/2 our 3 our Optional Construction: 3-our Rating 212 Fusible Link Factory Supplied Welded Sleeve: Length: 12 (305) 16 (406) 24 (610) Other: Gauge: 20 (1.0) 18 (1.3) 16 (1.6) 14 (2.0) 10 (3.5) Location in Sleeve: Standard Offset: inches Factory Supplied Integral Sleeve (20 gauge only): Length: 12 (305) 14 (356) 16 (406) Flanged Sleeve (requires factory welded sleeve): 3/4 (19) 1 Framed Retaining ngles - 16 ga. x 1½ x 1½ (1.6x38x38) Single Side ual Side Sealed Sleeve (Factory welded sleeve only) Fully Welded Other Options: Fully Caulked - ccess oors (see ) - ynamic models (see F) - Single lade (high free area) models (see F-RS) - Multi-lade models (see F-M) - Slimline and Ultra Slimline models (see s F-SL and F-V-U-SL) - Out-of-wall models (see F-OW) - True Round models (see F-R) uct eight* F-V uct Width* *amper width and height will be undercut 1/4 (6). uct eight* F- uct Width* 1

MPER STYLES & SIZES - F Type Frame and blade stack in air stream pproximately 75-85% Free rea F- Minimum & Maximum Sizes: Type Minimum Size Max. Single Section Max. Multi-Section F-V 60x60 (1524x1524) 48x48 (1219x1219) 120x120 (3048x3048) 80x40 (2032x1016) Type without Sleeve F- 4x4 (102x102) 48x48 (1219x1219) 40x40 (1016x1016) 120x40 (3048x1016) or 96x48 (2438x1219) imension = uct Width imension = uct eight 80x40 (2032x1016) Type with Welded Sleeve 12 (305) min. Type with Integral Sleeve¹ Type lade stack out of airstream pproximately 80-90% Free rea F- Minimum & Maximum Sizes: 3 4 " X Type F-V 60x55 (1524x1397) 48x43 (1219x1092) 120x115 (3048x2921) 80x36 (2032x914) Type without Sleeve F- 4x3 (102x76) 48x43 (1219x1092) 40x36 (1016x914) 120x36 (3048x914) or 96x43 (2438x1092) 80x36 (2032x914) imension = uct Width imension = uct eight X imension = eight of lade Stack imension = Overall amper eight (+X) Type with Welded Sleeve 12 (305) Min. Type with Integral Sleeve¹ 2

MPER STYLES & SIZES - F Type C Square or Rectangular Transition Frame and blade stack out of airstream pproximately 95-100% Free rea F-C Minimum & Maximum Sizes: 34 " X +1 " Rect./ Square Transition Type C F-VC F-C 3x3 (76x76) 59x54 (1499x1372) 47x42 (1194x1067) 47x42 (1194x1067) 39x35 (991x889) 119x114 (3023x2896) 119x35 (3023x889) or 90x42 (2286x1067) imension = uct Width imension = uct eight X imension = eight of lade Stack imension = Overall amper eight (+X+1 ) 79x35 (2007x889) 79x35 (2007x889) + Type C with Welded Sleeve Type C without Sleeve 1 1 " 4 + 12 (305) min. Type C with Integral Sleeve¹ Type C Oval Transition Frame and blade stack out of airstream pproximately 95-100% Free rea F-C-O Minimum & Maximum Sizes: Oval Transition Type C F-VC-O F-C-O 3x3 (76x76) 59x54 (1499x1372) 47x42 (1194x1067) 47x42 (1194x1067) 39x35 (991x889) 119x114 (3023x2896) 119x35 (3023x889) or 90x42 (2286x1067) 79x35 (2007x889) 79x35 (2007x889) 34 " X +1 + Type C-O without Sleeve 2" (51) + imension = uct Width imension = uct eight X imension = eight of lade Stack imension = Overall amper eight (+X+1 ) Type C-O with Welded Sleeve 12 (305) Min. Type C-O with Integral Sleeve¹ 3

MPER STYLES & SIZES - F Type C Round Transition Frame and blade stack out of airstream pproximately 95-100% Free rea F-RC Minimum & Maximum Sizes: Round Transition Type C F-RVC F-RC 3 ia. (76) 54 ia. (1372) 42 ia. (1067) 42 ia. (1067) 35 ia. (889) 114 ia. (2896) 35 ia. 42 ia. (889) (1067) 34 " X +1 Type RC without Sleeve + 2" (51) +1 X imension = eight of lade Stack imension = Overall amper eight (+X+1 ) imension = iameter 6" (152) Min. 12" (305) Min. Type RC with Welded Sleeve Type RC with Integral Sleeve¹ Type Round Transition lade stack in the airstream pproximately 75-85% Free rea F-R Minimum & Maximum Sizes: Round Transition Type F-VR F-R 4 ia. (102) 58 ia. (1473) 46 ia. (1168) 46 ia. (1168) 38 ia. (965) 118 ia. (2997) 46 ia. (1168) 38 ia. (965) 38 ia. (965) 34 " Type R without Sleeve +2 (51) +2" 2" (51) +2 (51) X imension = eight of lade Stack imension = Overall amper eight (+2 ) imension = iameter Type R with Welded Sleeve 12 (305) Min. Type R with Integral Sleeve¹ 4

IMENSIONL INFORMTION - F (for Type ) Type Fire amper uct eight () Type amper eight () 40 44 41 45 78 82 79 83 Inches Inches 42 46 80 84 ¾ 3 11 16 " " 3 5 4 6 5 7 6 8 7 9 8 10 9 11 10 12 11 13 12 14 13 15 43 48 44 49 45 50 46 51 47 52 48 53 49 54 50 55 51 56 52 57 81 85 82 86 83 87 84 88 85 89 86 91 87 92 88 93 89 94 90 95 14 16 53 58 91 96 15 17 54 59 92 97 16 18 55 60 93 98 17 19 18 20 19 21 56 59 57 60 58 61 94 99 95 100 96 101 20 22 59 62 97 102 21 24 60 63 98 103 22 25 61 64 99 104 23 26 24 27 25 28 26 29 27 30 28 31 29 32 30 33 31 34 32 35 33 37 62 65 63 66 64 67 65 69 66 70 67 71 68 72 69 73 70 74 71 75 100 105 101 106 102 107 103 108 104 109 105 110 106 111 107 112 108 113 109 114 34 38 72 76 110 115 35 39 73 77 111 116 36 40 74 78 112 117 37 41 75 79 113 118 38 42 76 80 114 119 39 43 77 81 115 120 5

IMENSIONL INFORMTION (Cont.) - F (for Type C) Type C Fire amper +1 " uct eight () Inches Type RC, C, C-O amper eight () Inches 37 42 38 43 39 44 40 45 76 81 77 82 78 83 79 84 3 6 41 46 80 85 4 7 42 47 81 86 5 8 6 9 43 49 44 50 82 87 83 88 7 10 45 51 84 89 8 11 46 52 85 91 + 1 1 " 4 2" 2" 9 12 10 13 11 14 12 15 13 16 14 17 15 18 16 19 17 20 18 21 19 22 20 23 21 25 22 26 23 27 24 28 25 29 26 30 27 31 47 53 48 54 49 55 50 56 51 57 52 58 53 59 54 60 55 59 56 60 57 61 58 62 59 63 60 64 61 65 62 66 63 67 64 68 65 70 66 71 86 92 87 93 88 94 89 95 90 96 91 97 92 98 93 99 94 100 95 101 96 102 97 103 98 104 99 105 100 106 101 107 102 108 103 109 104 110 105 111 28 32 67 72 106 112 29 33 68 73 107 113 30 34 69 74 108 114 + 31 35 32 37 33 38 34 39 35 40 36 41 70 75 71 76 72 77 73 78 74 79 75 80 109 115 110 116 111 117 112 118 113 119 114 120 6

MULTIPLE SECTION INFORMTION - F Multiple section damper assemblies are shipped in individual sections from the factory unless a factory supplied and installed sleeve is required. When a multiple section damper is ordered with a sleeve, it is usually shipped as a complete assembly. The following drawings are of different maximum size multiple section F models and are for reference purposes (not all options are shown). Type Multi-Section ssembly F-V Shown (max size): 1-1/2 our Vertical Type Multi-Section ssembly F- Shown (max size): 1-1/2 and 3 our orizontal 120" Max. O.. 60" Max. Single Section 120" Max. Multisection O.. 40" Max. O.. 60" Max. Single Section Type C Multi-Section ssembly F-C Shown (max. size): 1-1/2 our orizontal 120" Max. O.. Type C Multi-Section ssembly F-RVC Shown (max. size): 1-1/2 our Vertical 120" Max. Multisection 114" ø Round Inlet 4" Cap 60" Max. Single Section 36" Max. Single & Multisection 40" Max. O.. 119" Max. Multisection 120" Max. O.. 40" Max. Single Section 60" Max. Single Section 120" Max. Multisectio 4" Cap 35" Max. Multisection 40" Max. O.. 1. These diagrams are for reference purposes only 2. Not all F options are shown 7

SLEEVE IMENSIONL T - F elow are diagrams showing the location of the Type, and C fire dampers in welded factory installed sleeve. Integral sleeves (where the sleeve acts as the frame of the damper) are also available. Sleeve TYPE Sleeve Sleeve imensions = Overall damper height W = Overall damper width (always the length of the blades) = uct width = uct height O = The offset from one end of the sleeve to the middle of the damper frame (can be altered as a construction option) L = Overall length of sleeve TYPE amper Sleeve TYPE C amper amper 1-½" O amper Location L Overall O amper Location L Overall O amper Location L Overall W OPTIONL INTEGRL SLEEVE INFORMTION NC offers the cost and time saving option of having the sleeve be integral to the fire damper. It is offered on any of the fire damper types mentioned in this submittal (, R,, C, R(V/)C and C-O). On an integral sleeve fire damper, the sleeve acts as both the sleeve and the frame. Integral sleeve fire dampers are available in 20 gauge galvanized steel only and in lengths of 12" (305), 14" (356) or 16" (406). Integral sleeve fire dampers are less expensive than factory welded sleeves. TYPE TYPE R +2 (51) TYPE 8 Integral sleeve dampers are restricted to single sections. Refer to the max single section sizes within this submittal for those specific sizes. + +1 TYPE C TYPE R(V/)C TYPE C-O +