DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Similar documents
DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

EXT DUCTLESS FUME HOOD

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

EXT HEPA/CARBON FUME HOOD

FUME HOOD. Installation and Operations Manual

VCM LAMINAR FLOW HOOD VERTICAL

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

MODEL FA1 Mini Air Filtration System. Operations Manual

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Further information: Berriman Associates Model 850P.2 Owners Manual

User s Manual and Operating Instructions

FA1 Series Air Filtration System. Operations Manual

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

SUPER PUMP OUT SYSTEM

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

QPET, QPETXU Battery Chargers

CLEAN POWER TM CPS Series Operator s Manual

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Integrated Heating System

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Model G14SD Vapor Management System

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

BusPro Series Instruction Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Installation & Service Manual for Portable Fume Collector. Model PFC-800

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Operating Manual Includes Pumps: PG-9000 Part #R809606

MODEL 950C-NP-UV Installation and Owners Manual

Owner s Manual Drill and Light Weight Portable Utility Pumps

QSSE, QSSEX INDUSTRIAL Battery Chargers

SUBMERSIBLE SUMP PUMPS

Miracle State Of The Art Air Filtration System!

SUBMERSIBLE MINI-PUMP

Operating Manual PFB-2500

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual

LESTRONIC II BATTERY CHARGER MODEL 19740

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

User s Manual. Automatic Switch-Mode Battery Charger

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

MODEL GS1-100 Air Filtration System. Operations Manual

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

Operating Instructions for PAC800 Battery Charger

Powerful & Intelligent Submersible Pumps

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

SUBMERSIBLE SUMP PUMPS

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

AUTO CHARGE D PUMP PLUS

MODEL MC1500 Installation and Operation Manual Important:

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

OBE, OBEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

HA/HAB Fiberglass Wall Mount Ventilators

Effective June 1, 2013 This guide supersedes all previous versions

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

SPC-PANEL Simplex, Single Phase Pump Control Panel

BATTERY SAVER LOW RIPPLE HO

HEPA AIR FILTRATION SYSTEM

MODEL FA5 Air Filtration System. Operations Manual

SUNC3000 / Item #40885

PHOENIX GUARDIAN H. E. P. A. SYSTEM

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

FAN POWERED HEPA FILTER UNIT

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

Utility Distribution Systems Installation, Operation, and Maintenance Manual

PHOENIX MINI-GUARDIAN

BCFS Belt Driven Centrifugal Filtered Supply Fans

Record the serial number and date of purchase in your manual for future reference.

GeyserMax-Flow Series

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MODEL MA4210 Installation and Operation Manual Important:

SPH General Manual 400 Series

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Hot Dog Roller Grills Instruction Manual Model #8023, Model #8024 and Model #8025 Model #8023SL, Model #8024SL and Model #8025SL

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

User s Manual and Operating Instructions

D-Series Blowers and Exhausters

The Da-Lite Difference.

WF-5110R True Sine Wave Inverter

MODEL SCA Installation and Operation Manual Important:

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Transcription:

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 2 of 15

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 3 of 15 MODELS COVERED 230V MODELS DA2-2HSL-RSR-EC DA3-2HSL-RSR-EC DA4-2HSL-RSR-EC DA2-2USL-RSR-EC DA3-2USL-RSR-EC DA4-2USL-RSR-EC 115V MODELS DA2-1HSL-RSR-EC DA3-1HSL-RSR-EC DA4-1HSL-RSR-EC DA2-1USL-RSR-EC DA3-1USL-RSR-EC DA4-1USL-RSR-EC TABLE OF CONTENTS MODELS COVERED... 3 1. SHIPPING AND UN-CRATING... 4 2. FEATURES... 5 3. FILTER HOUSING... 5 4. VARIABLE SPEED CONTROL... 6 5. DUPLEX OUTLET... 6 6. POWER CORD... 7 7. PRE-FILTER... 7 8. PRE-FILTER MAINTENANCE... 7 9. HEPA FILTER... 8 10. CHANGING HEPA/ULPA FILTERS... 9 11. ROOM-SIDE-REPLACEMENT FILTER... 9 12. MOTOR/ELECTRICAL... 10 13. WIRING DIAGRAM... 11 14. DIMENSIONS... 13 15. AIRFLOW... 13 16. REPLACEMENT PARTS... 14 17. SOLUTIONS TO COMMON PROBLEMS... 14 18. WARRANTY... 15

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 4 of 15 Thank you for purchasing our Design-Aire SL-RSR-EC, with proper care and maintenance your unit will provide you with many years of trouble free performance. Please read instructions carefully before installing and operating your Design-Aire SL-RSR-EC. WARNING: TO REDUCE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS PLEASE REVIEW THE FOLLOWING PRECAUTIONS. Do not expose your Design-Aire SL-RSR-EC to rain or moisture. Always disconnect the Design-Aire SL-RSR-EC from power supply when servicing, moving parts may cause serious injury. Always disconnect while grasping the plug, not the cord. Do not expose Design-Aire SL-RSR-EC to gaseous or explosive vapors. Motors normally spark and may ignite fumes. Do not block airflow to top or back of unit, allow at least 4 above unit Do not modify the plug of your unit if it will not fit in your duplex outlet. Have a proper outlet installed by a qualified electrician. Use only specified replacement parts recommended by Design Filtration Microzone. Use this equipment only in the manner intended by Design Filtration Microzone. 1. SHIPPING AND UN-CRATING Design Filtration Microzone assembles and factory tests each unit prior to shipping. On occasion, damage can occur during the transportation of your new Design-Aire SL-RSR-EC. You should inspect your unit for damage that may have been caused and report it immediately to your transportation company. Carefully remove your Design-Aire SL-RSR-EC unit from the shipping carton and remove from plastic bag. Use extreme caution when handling HEPA filters; do not touch the filter media as damage can easily occur. All shipments are F.O.B. Design Filtration Microzone. All claims for damage due to shipping should be filed with the carrier. Design Filtration Microzone and its dealers are not responsible for shipping damages. Your Design-Aire SL-RSR-EC has been factory tested and set for appropriate airflows, however all HEPA filtered equipment should be certified by a qualified technician prior to use.

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 5 of 15 2. FEATURES Figure 2.1 Figure 2.2 3. FILTER HOUSING The filter/pre-filter housings are manufactured with light weight 16-gauge aluminum with easily removable catch hooks for trouble free filter changes. The housing features a screwed in place aluminum screen for the pre-filter placement, allowing quick and easy pre-filter change outs. All housings are sealed air tight with RTV silicone. The standard variable speed control and duplex are located on the pre-filter assembly.

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 6 of 15 4. VARIABLE SPEED CONTROL Design-Aire comes equipped with a variable speed control, which enables adjustments within the recommended airflow range. The variable speed control knob is located on the side panel of the pre- filter housing, opposite the duplex outlet. If your Design-Aire is equipped with the optional speed control cover you will require a #2 Philips screwdriver to remove the cover. Figure 4.1 5. DUPLEX OUTLET Design-Aire comes complete with a duplex outlet located on the pre-filter housing on the back of your unit. The duplex can be used for joining up to 6 Design-Aire units together. MAXIMUM DUPLEX OUTLET DRAW: 10-AMPS. Figure 5.1

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 7 of 15 6. POWER CORD Design-Aire comes complete with a grounded 3-prong electrical cord. Do not remove or alter ground on plug, serious damage could occur. Do not modify the plug of your unit if it will not fit in your duplex. Have a proper duplex installed by a qualified professional. 7. PRE-FILTER Your Design-Aire is equipped with disposable pre-filters, which are manufactured from bonded synthetic media set into a moisture resistant beverage board. Pleated pre-filters supplied with your Design-Aire carry an efficiency rating of MERV 7 (Minimum Efficiency Reporting Value) to change the pre-filters simply lift it off the pre-filter housing and replace dirty pre-filter with new pre-filter. 8. PRE-FILTER MAINTENANCE Disposable pre-filters cannot be washed or cleaned and should be changed regularly. You can determine a proper schedule for your facility based on your specific room conditions. Pre-filters should be inspected on a monthly basis or as room conditions dictate and replaced when necessary. Figure 8.1

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 8 of 15 9. HEPA FILTER Design-Aire HEPA filter features a 5.88 deep anodized aluminum frame with a protective painted screen located on the filter face. The 2 pleat wet laid glass media is set into the frame with a urethane seal. Efficiency is minimum 99.99% at 0.3 micron particle size and larger. HEPA filters cannot be cleaned and must be replaced when necessary. Your Design-Aire may be equipped with an optional ULPA filter which is rated minimum 99.9995% efficient at 0.12 microns and larger. ULPA filters cannot be cleaned and must be replaced when necessary. Your independent certifier, who is trained in the testing and certification of HEPA/ULPA filters, can determine when your filters are loaded (dirty) and should be changed. Figure 9.1

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 9 of 15 10. CHANGING HEPA/ULPA FILTERS Disconnect Design-Aire from the power source prior to servicing your unit. Loosen but do not remove the 4 Philips screws holding the tabs in place. Have your assistant gently lift filter pack to remove pressure on the tabs. Adjust the tabs to clear the filter pack and lower until it is clear of the frame. Figure 10.1 11. ROOM-SIDE-REPLACEMENT FILTER INSTALLATION PRECAUTIONS Installation is the reverse of above, making sure the filter pack is as central as possible. Adjust the tabs as in Figure 11.2. Filter installation requires two people. All unit frames must be secured to the T bar grid before filters may be installed. During installation DO NOT exert force on the grill screen or damage will result.

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 10 of 15 Figure 11.1 Figure 11.2 12. MOTOR/ELECTRICAL Design-Aire uses 230-volt, energy efficient backward curved impellers to provide excellent airflow distribution, quieter noise levels and low heat loads. No maintenance is required for the motors, although a periodic inspection for dirt build up is recommended. Dirt on your motor can cause vibrations and shorten the life cycle of the motor. The standard variable speed controller comes complete with on/off switch to help increase filter life cycle. A duplex outlet located on the pre-filter assembly enables units to be joined together in series, thus helping reduce additional up front in house electrical costs, up to six units or 10-amps may be plugged into the duplex. A standard FT2 type 3-prong electrical cord is included with your Design-Aire. Always check local electrical codes prior to installing your Design-Aire unit.

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 11 of 15 13. WIRING DIAGRAM Figure 12.1 230-Volt Model

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 12 of 15 Figure 12.2 115-Volt Model

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 13 of 15 14. DIMENSIONS Model Dimensions Electrical Weight Shipping Weight Shipping Dimensions DA2-2HSL-RSR-EC 23.62 x 23.62 x 11.25 230V, 0.13A 60Hz 31lbs 33lbs 12 x 24 x 25 DA3-2HSL-RSR-EC 23.62 x 35.62 x 11.25 230V, 0.25A 60Hz 42lbs 46lbs 12 x 36 x 25 DA4-2HSL-RSR-EC 23.62 x 47.62 x 11.25 230V, 0.25A 60Hz 46lbs 49lbs 12 x 48 x 25 Model Dimensions Electrical Weight Shipping Weight Shipping Dimensions DA2-1HSL-RSR-EC 23.62 x 23.62 x 11.25 115V, 0.8A 50/60Hz 31lbs 33lbs 12 x 24 x 25 DA3-1HSL-RSR-EC 23.62 x 35.62 x 11.25 115V, 1.6A 50/60Hz 42lbs 46lbs 12 x 36 x 25 DA4-1HSL-RSR-EC 23.62 x 47.62 x 11.25 115V, 1.6A 50/60Hz 46lbs 49lbs 12 x 48 x 25 15. AIRFLOW Model Speed control full No pre-filter Speed control full 1 pre-filter Speed control low No pre-filter DA2-2HSL-RSR-EC 442 cfm 410 cfm 195 cfm DA3-2HSL-RSR-EC 730 cfm 689 cfm 240 cfm DA4-2HSL-RSR-EC 948 cfm 870 cfm 460 cfm DA4-2USL-RSR-EC 916 cfm 837 cfm 409 cfm Figure 14.1

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 14 of 15 16. REPLACEMENT PARTS Parts Replacement HEPA filter for DA2-2HSL-RSR-EC (nominal 2 x 2) Replacement ULPA filter for DA2-2USL-RSR-EC (nominal 2 x 2) Replacement HEPA filter for DA3-2HSL-RSR-EC (nominal 2 x 3) Replacement ULPA filter for DA3-2USL-RSR-EC (nominal 2 x 3) Replacement HEPA filter for DA4-2HSL-RSR-EC (nominal 2 x 4) Replacement ULPA filter for DA4-2USL-RSR-EC (nominal 2 x 4) Disposable pleated pre-filter (case of 12) 230-volt EC motor 115-volt EC motor Speed controller (10K POT) Order Number 10HE0572 10HE0571 10HE0570 10PR0301 17MI0004 17MI0002 17SW0045 17. SOLUTIONS TO COMMON PROBLEMS Fan filter unit does not start Low airflow from downstream side of HEPA High airflow from downstream side of HEPA Electrical power cord may not be plugged in or connection may be loose Fuse blown, circuit breaker tripped, power outage has occurred Motor is overheated. FFY motor will stop if overheated Variable speed control is in off position Pre-filters are dirty HEPA filter is loaded. Variable speed control is turned down Power supply is not correct. Low voltage will affect operation of fan filter unit One of the motors on the twin fan units has stopped working (DA3 and DA4 models) Variable speed control is too high Make sure plug fits tightly into duplex outlet Reset breaker or replace fuse. Do not increase fuse capacity. If circuit is overloaded contact qualified electrician. Call local electric company for power outage Motor will automatically restart after cool down period See page 6 for operation of variable speed control Change pre-filters and re-test airflows. See page 7 Have qualified technician change HEPA filter and re-test airflows. See page 9 Adjust variable speed control to increase airflow output. Re-test airflow Have qualified electrician determine proper voltage input at source Have qualified technician replace motor and re-test airflows Adjust variable speed control to decrease airflow output. Re-test airflow

DESIGN-AIRE SL-RSR-EC Installation and Operations Manual Revision: 06-Feb-17 Page 15 of 15 18. WARRANTY Design Filtration Microzone warrants the equipment to be free of defects in materials and workmanship from the date of invoice. The Design-Aire SL-RSR-EC shall be warranted against defects for a period of two years. Any units or parts found to be defective during this period will be replaced or repaired at our discretion. The buyer agrees to assume all transportation charges prepaid for return of unit to factory for repair. Design Filtration Microzone will not accept charges for removal or re-installation. Design Filtration Microzone will not accept any returned items without prior written consent. Design Filtration Microzone is not responsible for repair or replacement by misuse or abuse by incorrect operating procedures of its equipment. Pre-filters and carbon filters carry no warranty against loading. Any modifications or changes made to equipment by customer without written consent of Design Filtration Microzone will void the warranty. Model number and serial number located on your Design-Aire SL-RSR-EC must be provided to verify invoice date. Failure to provide will void warranty. FOR FURTHER INFORMATION, PLEASE CONTACT US DIRECTLY. Design Filtration Microzone Inc., 86 Harry Douglas Drive, Ottawa, ON. K2S 2C7 T: 1-888-636-8609 (Canada & USA), T: 1-613-831-8318, F: 1-613-831-8321 info@dfmzgroup.com