Installation and Operating Instructions

Similar documents
Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Operating Instructions

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Operating manual Separator

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Pressure relief valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Operating and installation instructions

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Operating and installation instructions

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

These installation and maintenance instructions must be read in full and completely understood before the installation!

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Series 250 Pneumatic Control Valves Type and

Operating and installation instructions

Installation and operating manual

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

Operating and installation instructions

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

HAWLE-AIR RELEASE VALVES

Installation and service instruction

Ball valve for pipeline systems

Operating manual Vacuum Breaker

Butterfly Valve Type 57P

Installation and service instruction

Soft seated butterfly valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Installation, Operation, and Maintenance Manual

Diaphragm Valves Type 15

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Butterfly_Valve_Type57P

General information Gate valves

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Instructions for installation, operation and maintenance of: GATE VALVE

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Operating and maintenance manual Control valve ECOTROL Series 8C / 1.1

Operating and installation instructions

Mounting and Operating Instructions EB 5868/5869 EN

Angle seat valve with diaphragm actuator VZXA-...-M

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

GBV-G Balancing Valves

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Operating and installation instructions

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

KLINGER Piston Valves KVN DN PN 16 I/III with valve ring KX-GT Modul

Operating and installation instructions

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

3-Way Ball Valve Type 23H

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Butterfly valves Figure 56 Installation & Maintenance Instructions

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

Membranventil Kunststoff, DN Diaphragm Valve Plastic, DN GEMÜ 600 Antriebsgröße Code 2-4 Actuator size Code 2-4

Diaphragm Valve Type 72

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

Angle seat valve with piston actuator VZXA-...-K

Valtek Auxiliary Handwheels and Limit Stops

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Butterfly Valves ASAHI AV VALVES

Installation, Operation, and Maintenance Manual

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

MUELLER ECCENTRIC PLUG VALVE

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting Instructions with Operating Instructions and Technical Appendix

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Valve Series V2001 Three-way Valve Type 3323

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

Fisher TBX Hydro Plug Fixture

Assembly and Maintenance Manual Type ASNU

Butterfly Valve Type 58 (PDCPD)

Operating manual Keula gate valves DN PN10/16

Installation and Operation Manual

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Transcription:

Original Installation and Operating Instructions Hawle E2 Valve with Flange Outlet, System 2000 or PE Spigot Ends Table of Contents A) General...... 2 A1 Symbols..... 2 A2 Intended use... 2 A3 Labeling... 3 A4 Transport, Storage and Handling..... Transport and Storage..... Handling.. B) Installation and Functional Check 4 B1 Safety Instructions for Installation... 4 B2 Earthworks Requirements for E2 Valve with Flange.... 4 B3 Pressure, Direction of Flow and Installation Location.. 5 B4 Supporting the Fitting in Special Cases.... 5 B5 Installation Steps.... 5 B6 Pressure Testing prior to/during Commissioning.. 7 B7 Removal of Fitting.... 7 C) Operating and Maintenance.. 7 C1 Warning Instructions for Operation and Maintenance. 8 C2 Automated Operation... 8 C3 Maintenance.... 8 C4 Troubleshooting... 9 C5 Parts List... 10 C6 Conversion of Standard Valve to Lantern for Electric Operation... 11 C6 Conversion of Standard Valve to Lantern for Electric Operation... 12 C7 Conversion of Standard DN500-600 Valve to Lantern for Electric Operation... 12 C7 Conversion of Standard DN500-600 Valve to Lantern for Electric Operation... 13 C8 Conversion of Standard DN250-400 Valve to Lantern for Electric Operation... 14 C8 Conversion of Standard DN250-400 Valve to Lantern for Electric Operation... 15 3 3 4 1 P a g e

A) General An E2 valve is also referred to as a "fitting" in this manual. A1 Symbols Notes are highlighted by symbols in this manual. Danger/Caution/Warning...points to a dangerous situation that can lead to death or severe injuries of persons. Note...provides information that must be considered in any event. Information...provides useful tips and recommendations. If these notes as well as cautionary hints and warnings are not observed, this can lead to dangers and render the manufacturer's warranty void. A2 Intended Use The valve is intended to shut off or allow the flow of media (drinking water for human consumption) inside a pipe after installation within certain permitted pressure and temperature limits. The upper temperature limit is 40 C, the maximum operating pressure is marked on the housing and the model plate provided on the fitting itself. The media must flow without any vibrations and/or pressure surges and the environment may not pose a hazard for the fitting itself. The valve must preferably be installed with the drive positioned vertically to the top. For horizontal installations, an attached drive must be supported accordingly. Please observe the following regarding installation and operation of the valve: These original Installation and Operating Instructions The manufacturer, Hawle Armaturenwerke GmbH, does not assume responsibility in the event this "Intended Use" Section is not adhered to. 2 P a g e

A3 Labeling Every valve is labeled as follows DN XXX: (mm) Nominal Width PN XX: (bar) Pressure Class of Housing Serial Number: Year of Manufacture, individual Hawle Works Number The type plate should not be covered up so that the installed fitting remains identifiable. The indicated "Max. MOP" is the maximum permissible operating pressure. In case of further inquiries to the manufacturer, Hawle Armaturenwerke GmbH, the "Serial Number" according to the type plate must be indicated. A4 Transport, Storage and Handling Note: Additional information may be contained in the instruction manual of the drive, which must also be adhered to. Transport and Storage: The valve must be kept in the factory packaging in an opened condition until installation. The fittings must be stored in clean and dry rooms and be protected from dirt, moisture and other contamination. The valve may not continuously be exposed to direct sunlight as the coating is not resistant to UV radiation. If intermediate storage outdoors is required, package the valve in thick plastic foil for protection from dirt. The fitting was packaged in accordance with the ordering conditions. In the event of any transport damage, please notify the shipping company in writing. 3 P a g e

Handling: If lifting gear has to be used, only flexible belts may be employed. These must be fitted to the housing itself. The lifting gear must be designed for the weight of the valve. Starting with DN250, the eyebolts provided on the valve may be used. Never fasten any belts: To the drive, hand wheel Transversely through the opening of an opened valve B) Installation and Functional Check These instructions contain safety information regarding foreseeable risks during installation of the fitting into a (piping) system. It is the responsibility of the user to adhere to these instructions in addition to being mindful of any local risks. Observance of all system requirements is considered a prerequisite. B1 Safety Instructions for Installation The installation of fittings into the system may only be performed by specialist personnel. Specialists in accordance with these instructions are persons that can properly assess and implement the working operations they are entrusted with due to their training, knowledge and professional experience and are capable of recognizing and eliminating possible dangers. The intended function of a fitting after installation (and the drive, if available) must correspond to the <Intended Use>, which is described in Section A2. 1. A valve fitted at the end of a line must be secured using a safety device so that operating personnel and other persons cannot come too close to an opened valve and that they are protected from injury due to the escaping medium in the event of an opened valve. Risk to life and limb of user in case of non-compliance. Every other use of the fitting is the user's own risk. B2 Earthworks Requirements for E2 Valve with Flange It must be ensured that the installation conforms to the "Intended Use", see Section A2. The information on the type plate must be observed see Section A4 the pipe section is clear of any vibrations and pressure surges during operation and that no pipe forces can deform the valve housing in such a manner that opening/closing and/or the leak-tightness/proper functioning of the valve is adversely affected. the environment poses no risk for the fitting or drive. the flanges, pipe and fitting are emptied and free of any dirt particles. the valve is mounted in such a manner that it always remains tight to the outside. the valve is protected from heat radiation, if it is installed in the vicinity of a heat source, which exceeds the permissible temperature for the valve (and its drive). in particular, the sealing surfaces of the counterflange fully cover the sealing strips of the valve on both sides. The data sheet of the corresponding valve type provides exact and detailed information regarding flange dimensions, see Hawle Catalog. the instructions for connecting the mounted drive to local controls are observed. 4 P a g e

the pipe section is depressurized during installation. additional information provided in the instructions of the drive are observed, particularly those referring to the adjustment of the OPEN and CLOSED positions prior to the installation of the fitting into the pipe section. Fig. 2 B3 Pressure, Direction of Flow and Installation Location With the fitting opened (P1=P2), the pressure must be limited to the value indicated as max. permissible pressure on the type plate. With the fitting closed, the differential pressure P = (P1-P2) may not exceed the value. (Fig. 2) B4 Supporting the Fitting in Special Cases The weight of the module and drive of the fitting can cause deformations and functional problems, particularly in case of installation into oblique or vertical lines. To avoid this, the valve and drive must then be supported on part of the building site. If vibrations and/or pipe forces are transmitted by the pipeline, which could adversely affect the functioning of the valve, the valve must also be supported. Details and execution of this support are the responsibility of the user. B5 Installation Steps It must be ensured in accordance with Fig. 3 that the valve and the two opposing pipe ends are flush and the sealing surfaces of valve and pipeline flange are exactly parallel. If this is not observed, the valve could be damaged through erosion and/or dead spaces can form in front of or behind the fitting where deposits may collect, which could prevent tight closure of the fitting and cause corrosion on the valve itself. Fig. 3 1. Insert flange seals between valve and counterflanges and center them exactly. The sealing must cover the working strip for the flange seal fully. 2. Lightly grease the flange screws: this makes it easier to tighten and later loosen the nuts. Use screw dimensions in accordance with HAWLE catalog sheet and depending on used counterflanges. 3. First hand-tighten the screws all around, then tighten them evenly in a crosswise fashion (see Fig. 4 and Catalog). 4. Consider the following tightening torques for galvanized St 4.8 steel screws (non-lubricated): 5 P a g e

Screw dimension Max. tightening torque per screw (Nm) M12 32 M16 90 M20 140 M24 200 M27 250 M30 300 An opening/closing functional test must be performed in the end. The instruction manual of the drive must be followed. It must be possible to open and close valves with hand wheel using normal manual force. When connecting the drive, follow the instruction manual of the drive manufacturer: the drive must correctly move the valve to the OPEN and CLOSED positions using the corresponding control signals. Fig. 4 5. For the E2 Valve System 2000, the instruction manual supplied with the System 2000 Socket must be observed for pipe connections. 6. For E2 Valves with PE Spigot Ends, follow the processing instructions of the corresponding pipe manufacturer for pipe connections. 7. If the pipeline has to be flushed clean, the valve must be opened 100 %. Valves that are supplied with drives by Hawle are correctly adjusted for their end positions from the factory. This setting should not be changed as long as the valve is functioning properly. Only for valves with electric drive: It must be ensured that the drive is deactivated when closing by the signal of the torque switch. It must be ensured that the drive is deactivated when opening by the signal of the limit switch. The signal of a torque switch should be used within the final stop area for fault messages. Too high forces may damage the valve. Further information is provided in the instruction manual of the electric drive. 6 P a g e

B6 Pressure Testing prior to/during Commissioning Every valve was subjected to a final inspection by Hawle in accordance with EN12266-1. The testing conditions for a pipeline section apply for pressure testing of a fitting within a system, but with the following restrictions: The testing pressure of a fitting may not exceed a value of "1.5 x max. working pressure" (in accordance with fitting type plate, see Section A4). The wedge must be in the opened position. A closed valve may not be loaded with more than "1.1 x max. working pressure" so that the wedge is not overloaded. B7 Removal of Fitting Note: The information provided in the instruction manual of the drive must also be followed. The same safety instructions as for the pipe section apply and, if available, also for the drive and control system. These instructions must also be followed when removing the fitting. Remove the valve with the following steps: 1. First depressurize and fully empty all pipe sections. 2. Then disconnect all electrical supply lines (only for drive). 3. Only use the fastening methods stated in Section A4. The valve may only be removed from the pipeline, if: the pipe section is entirely depressurized and empty, all electrical supply lines have been disconnected (drive). Risk to life and limb of persons in the vicinity of the fitting if these warnings are not heeded by the user. 4. Take care when pulling out the fitting: Do not damage the flange sealing surfaces. 5. Observe Section A4 for transport and storage. C) Operating and Maintenance Note: Additional information may be provided by the instruction manual of the drive. The planner of the system must perform a comprehensive risk analysis in accordance with MRL 2006/42/EG. To this end, Hawle Armaturenwerke GmbH will provide the following documents: Installation and Operating instructions, an instruction manual for the drive regarding notes on connection to the control system. This instruction manual contains safety instructions regarding foreseeable risks when using the fitting in an industrial setting. It is the responsibility of the planner/operator to adhere to these instructions in addition to being mindful of any plant-related risks. 7 P a g e

C1 Warning Instructions for Operation and Maintenance The function of the fitting must correspond to the <Intended Use>, which is described in Section A2. The operating conditions must match the information on the type plate of the valve, see Section A3. Necessary work on the fitting itself may only be performed by specialist personnel. Specialists in accordance with these instructions are persons that can properly assess and implement the working operations they are entrusted with due to their training, knowledge and professional experience and are capable of recognizing and eliminating possible dangers. The valve should be checked periodically during operation to guarantee the safety of the personnel. During maintenance or repair operations, the valve must be deactivated as stated in Section B7: The pipe sections on either side of the fitting must be depressurized and emptied prior to starting any work. C2 Automated Operation A manually actuated valve is closed by turning a hand wheel in the clockwise direction and opened by turning in the opposite direction. A valve with drive actuation is operated using control signals. Valves that are supplied with a drive from the factory are supplied in a correctly adjusted and configured manner. This configuration should not be changed as long as the fitting works as intended. Valves with rare actuation: In order to maintain functionality of a valve, it should be actuated with a full stroke at least once a year. C3 Maintenance 1. Actuation of a valve with drive is only permitted: After it has been connected to the pipeline. 2. If a valve was installed as an end valve in a system section, a suitable safety device must prevent access to the moving parts of the vale and protect the personnel from escaping media. Risk to life and limb of user in case of non-compliance. Every other use of the fitting is the user's own risk. As long as the valve seals correctly, the only required maintenance is a visual check of the leaktightness of the housing in suitable intervals. 8 P a g e

C4 Troubleshooting Problem Cause Remedy Leakage of flange connection Incorrect length of flange screws Flange screws not properly tightened Valve not centered correctly Flange sealing surfaces between pipeline/fitting not exactly parallel Flange sealing not correctly centered Incorrect flange sealing material Leakage in valve opening Wedge not closing 100 % Damaged wedge Plate does not open/close 100 % Drive fault Drive circuit fault (provided end switch or mechanical stop) Wedge leaking due to deposits Wedge mechanically damaged Wedge nut worn See this Instruction Manual, Section B5 See supplied drive instruction manual Replace wedge See supplied drive instruction manual Replace wedge nut Relubricate spindle If replacement parts are used for maintenance/repairs that are not original Hawle replacement parts and/or the instructions regarding operation, maintenance and repairs are not observed by the user, Hawle Armaturenwerke GmbH will not provide a warranty for damages to the fitting. 9 P a g e

C5 Parts List Item Part Material 1 Body GJS 400 2 Bonnet GJS 400 3 Wedge GJS 400 externally vulcanized elastomer 4 Wedge guide POM 5 Wedge nut Brass 6 Spindle Steel 7 O-ring bush Elastomer 8 O-rings, lip seals Elastomer 9 Back seal Elastomer 10 Wiper ring Elastomer 11 Bonnet gasket Elastomer 12 Allen screws 8.8 13 Edge protection PE 14 Ball bearing from DN250 Steel 15 Centering ring POM 16 Centering flange GJS 400 17 Centering flange gasket Elastomer 18 Retaining ring POM 19 Sealing compound POM From DN250 DN250-600 DN50-200 Item Part Material 20 Adapter GJS 400 21 Spindle sleeve GJS 400 22 Pin Steel 23 Feather key Steel 10 P a g e

C6 Modification of a standard valve DN50-200 with an adapter for an electric actuator 1. E2 valve for operation by hand. 2. Place the retaining ring into the slot. The gap in the retaining ring and the locking rib have to be aligned. 3. Mount the lantern on the upper body. The locking rib and the recess in the lantern define the mounting position. 4. Mount the lantern onto the upper body, all the way to the end stop. 5. The recess in the retaining ring and the hole in the lantern fixture have to be aligned with each other. 6. Attach the lantern to the upper body with the included bolts. Maximum tightening torque: 80Nm 11 P a g e

7. Attach the spindle socket and the spigot onto the spindle in the lantern. 8. Completely mounted lantern. C7 Modification of a standard valve DN250-600 with an adapter for an electric actuator 1. Remove the wax sealing from the centering flange screws. 2. Loosen the inner hex bolts and remove them. 3. Remove the centering flange. 4. In case the upper ball bearing or the bearing ring remains in the central flange, take them out. 12 P a g e

6. Fasten the lantern with the supplied bolts 5. Mount the adapter incl. the POM centering ring and the scraper ring on the upper part 7. Mount the spindle socket with spigot into the square cap 13 P a g e

C8 Modification of a standard valve DN250-600 with an adapter for an electric actuator (use newly coated spindle) 1. Remove the wax sealing from the centering flange screws. 2. Loosen the inner hex bolts and remove them. 3. Remove the centering flange. 4. In case the upper ball bearing or the bearing ring remains in the central flange, take them out. 5. Unscrew the spindle with the ball bearing and the o-ring bracket by rotating them clockwise 6. Mount the ball bearing and the o-ring bracket on the newly-coated spindle (in the same order as with the original spindle) Screw in the spindle into the wedge nut by rotating it counterclockwise. 14 P a g e

7. Locking pin of the o-ring bracket has to be placed into the recess on the upper body. 8. Mount the adapter incl. the POM centering ring and the scraper ring on the upper part 9. Fasten the lantern with the supplied bolts 10. Mount the spindle socket with spigot into the square cap Vöcklabruck, 05.04.2017 Fellner A. / Lerchner S. 15 P a g e