HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

Similar documents
Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

DC POWER SUPPLY ALIMENTATION C.C.

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

DC REGULATED POWER SUPPLY

DC REGULATED POWER SUPPLY

3000 Series Operation Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Triple Output Power Supply

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Declaration of Conformity

Triple Output High Resolution Power Supply. User Manual

Model 1672, 1673 Triple Output Power Supply

DC POWER SUPPLY GPS-S SERIES (ANALOG 1 DIGITAL TYPE) User Manual ISO-9001 CER TIFIED MANUFACTURER

DC POWER SUPPLY (Switching mode)

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

INSTRUCTION MANUAL Model 1743B

Using Your SMT Micro Anodizer 0-120VDC/0-1A

SAFETY TERMS AND SYMBOLS

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

Instruction Manual. Model Y5020. Current Shunt. P/N September 1979

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

High Accuracy Series REGULATED DC POWER SUPPLY. User s Manual

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

SAM Series Power Inverter

MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

Owners Manual. Autosound Series Power Supply APS-100 APS-100X

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

ISO9001 DC TO AC POWER INVERTER. DC 12V TO AC Instruction Manual Please read user manual before use. CAUTION

Owner s Manual. DC-DC Step Down Converter

3.00 A 30.0 V. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com CURRENT FINE VOLTAGE POWER - GND + C.

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Switching DC Power Supply

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

OWNER S MANUAL POWER INVERTER

Selectable Impedance Adapter

Dawson DDM190D. Digital Multimeter User s Manual

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

SAFETY WARNINGS AND GUIDELINES

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

12VDC TO 230VAC INVERTERS

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

WARNINGS, CAUTIONS AND NOTES

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

BS20 BATTERY CHARGER For lead-acid batteries

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

AC CONVERTER / BATTERY CHARGER

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual

HPP1 MK6-15A/20A R00 Owners Manual

CT325 TEMPERATURE CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

TRIPLE OUTPUT POWER SUPPLY Agilent MODEL E3630A

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

ESD5500E Series Speed Control Unit

Power Supply EL

INSTRUCTION MANUAL FOR Revision C MODEL SERIAL NUMBER LAMBDA EMI 405 ESSEX ROAD, NEPTUNE, NJ 07753

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

USER MANUAL. Insulation Tester + DMM. Model MG320

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

1. SAFETY TERMS AND SYMBOLS. Contents. 1. Safety terms and symbols Installation Operation.. 4

Mini Multimeter with Non-Contact Voltage Detector (NCV)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

SUBSTATION EQUIPMENT - Page 1 of 8

AT30 SERIES BATTERY CHARGER

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Contents. Design Test Results for Specimen Design Test Results for Specimen Voltage Impulse Oscillograms...9

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

BASIC ELECTRICAL MEASUREMENTS By David Navone

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

EXPERIMENT 4 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

EPS/ELA-Series User Manual EPS/ELA 250W

LFP-RCR123A Product Specification. Specification Approval Sheet

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

General Precautions. Personnel Precautions

SECTION DC POWER SUPPLY/BATTERY CHARGER

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

Transcription:

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

This series include two-way and three-way DC regulated power supply. Three-way have high accuracy output of which two way are adjustable and one way is fixed. The two adjustable outputs can be selected for constant voltage (C.V.) or constant current (C.C.), designed in high stability and performance circuit. In constant voltage operation mode the output voltage can be arbitrarily adjusted from 0V on in the nominal range. In constant current operation mode, the output current can be adjusted from 0A on in the nominal range. The two outputs can be connected in parallel or in series, while the master adjust controls the voltage and current setting. The fixed output voltage is 5V. This output features good stability and low ripple along with overload (e.g. short circuit) protection. The unit features small size and excellent performance combined with an elegant design, being ideal for research university industry and appliance maintenance laboratories. 1. Technical Specification 1. Model: HT3003PB, HT3005PB 1.1.1 Input voltage: 220VAC 50Hz 1.2 Two adjustable outputs 1.2.1 Output voltage: 0-30V(adjustable continuously) 1.2.2 Output current: 0-3A 0-5A(adjustable continuously) 1.2.3 Source regulation: Cv 0.01%+3mV Cv 0.01%+5mV 1.2.4 Load regulation: Cv 0.01%+2mV(rated 5A) Cv 0.01%+5mV(rated>5A) Cc 0.01%+6mV 1.2.5 Ripple and noise: CV 1mV(rms) CV 20mVp-p CC 3mA(rms) CC 50mAp-p 1

1.2.6 Protection: current-limiting protection 1.2.7 Indication: Voltmeter & Ammeter or 3-digit volt-(led) &Amp-(LED) a. Volt-indication: (LED)±1%±2digits b. Amp-indication: (LED)±2%±2digits 1.3 Fixed output: 1.3.1 Output voltage: 5V±3 1.3.2 Output current: 3A 1.3.3 Source regulation: 1 10 1mV 1.3.4 Load regulation: 1 10 1.3.5 Ripple noise: 0 5mV rms 10mVp-p 1.3.6 Protection: current limiting short circuit protection 1.4 Operating ambient 1.4.1 Operating temperature: 0 to 40 C 1.4.2 Relative humidity: less than 90 1.5 Size: 360mm 265mm 165mm 1.6 Operating time: 8hours continuously 2. Operation 2.1 Controls and description of front-panel (1) Meter or (LED): indicates master output voltage and current value. (4) Meter or (LED): indicates slave output voltage and current value. (5) Slave constant voltage adjustment: adjust slave output voltage value. (6) Slave constant current adjustment: adjust slave output current value. (adjust the current-limiting protection point). (7) Power switch: It is set to ON state (the switch is pressed in), the unit is switched on, at this time the constant voltage (C.V.) or constant current (C.C.) indicator is on, otherwise, the unit is in OFF state (the switch is sprung out). (8) Slave constant current state or two-way parallel state indicator: When slave output is in constant current state or the two adjustable is in parallel, this indicator is on. (9) Slave constant voltage indicator: When slave output is in constant voltage state, this indicator is on. 2

(10) Slave output negative binding post: Negative polarity of output voltage is connected to negative terminal of load. (11) Case grounded terminal: The case is connected to the earth. (12) Slave output positive binding post: positive polarity of output voltage is connected to positive terminal of load. (13/14) The control switch for selecting the two adjustable outputs independent, series or parallel. (15) Master output negative binding post: Negative polarity of output voltage is connected to negative terminal of load. (16) Case grounded terminal: The case is connected to the earth. (17) Master output positive binding post: Positive polarity of output voltage is connected to positive terminal of load. (18) Master output constant current state indicator: When master output is in constant current state, this indicator is on. (19) Master output constant voltage state indicator: When master output power is in constant voltage state this indicator is on. (20) Fixed 5V DC output negative binding post: Negative polarity of output voltage is connected to negative terminal of load. (21) Fixed 5V DC output positive binding post: Positive polarity of output voltage is connected to positive terminal of load. (22) Master output constant current adjustment: Adjust master output current value Adjust current limiting protection point. (23) Master output constant voltage adjustment: Adjust master output voltage value. 3

2.2 Operating procedure 2.2.1 Independence use of two adjustable outputs. 2.2.1.1 Set the (13) and (14) switch to spring out position ( position). 2.2.1.2 When the adjustable output is used as C.V. output, first should rotate clockwise the C.C. adjustment (6) and (22) to Max, then turn on power switch (7), adjust C.V. adjustment (5) and (23) till slave & master DC output voltage reach required voltage value, at this time, the C.C. indicator (8) and (18) light off. 2.2.1.3 Used as C.C. output, after turning on power switch (7), first rotate clockwise the C.V. adjustment (5) and (23) to Max, while rotate counterclockwise the C.C. adjustment (6) and (22) to Min, then connect the required load, again rotate clockwise adjustment (6) and (22) till output current reach the required current value. At this time the C.V. State indicator (9) and (19) go out and the C.C. state indicator (8) and (18) light on. 2.2.1.4 Used as the C.V. output, in general the C.C. adjustment (6) and (22) should be set to Max, but for this unit, the current-limiting protection point can also be set arbitrarily. Setting procedure is: Turn on power, rotate counterclockwise the C.C. adjustment (6) and (22) to Min, then make the positive and negative output terminal in short connection and rotate clockwise the C.C. Adjustment (6) and (22) till output current equal to the required current-limiting protection point so the 4

current-limiting protection point is well set. 2.2.2 Series using of the two adjustable outputs 2.2.2.1 Press in switch (13) ( position), switch (14) is set to OUT position ( position). At this time, turn the master voltage adjustment (23) and the slave output voltage tracks strictly the master output voltage, and the output voltage can be up to 60V (voltage between terminal of (10) and (17)). 2.2.2.2 Before the series connecting, it must be examined if the negative terminals of both master and slave output are connected to GND terminal, if they are, it must be disconnected, otherwise short-circuit will be caused in the slave output when the two outputs are connected in series. 2.2.2.3 When the two outputs are in series, the output voltage is controlled by master output, but current adjustment of two outputs is still independent. Therefore, attention should be paid to the position of the C.C. adjustment (6). For example, knob (6) is at the position of counter- clockwise to end or current of slave output excesses current- limiting protection point, at this time the voltage of slave output will not track the voltage of master. So knob (6) should be rotated clockwise to Max, when the two output are in series. 2.2.2.4 By series connection, if there is power output, proper leads corresponding to output power should be used to short connect the negative terminal of master output with positive terminal of slave output reliably. Since it is shorted by a switch inside the unit, current will pass on the shorted switch when there is power output. This will affect the reliability of the unit. 2.2.3 Parallel using of the two adjustable outputs 2.2.3.1 Press in switch (13) ( position) as well as switch (14) ( position), at this time, the two outputs are in parallel, adjust voltage adjustment (23) of master output the voltage of two ways keep same, and slave output C.C. indicator 8 lights on. 2.2.3.2 When the two outputs are in parallel, the C.C. adjustment (6) of slave output does not work When used as C.C. Supply simply adjust the C.C. adjustment (22) of master output, at this time output current of both master and slave output are controlled by it and are same, output current is up to 6A or10a. 5

2.2.3.3 While the two outputs in parallel, proper leads corresponding to outputpower be used to short reliably the two positive terminals and the two negative terminals of master & slave output separately, so as to make load connected reliably with the two parallel outputs. If the load is only connected to one of the output terminal, unbalance may be caused to current of the two outputs, this may also damage the series/parallel switch. 2.3 The digital display is in 3-digit If you need more accurate indication, please use more precise measuring instrument to calibrate it in outer circuit. 2.4 Cautions 2.4.1 The unit has perfect protection function, 5V output has reliable protection for current - limiting and short circuit. The two adjustable outputs have current limiting protection. As there is controlling circuit for regulating transistor s power loss in the circuit when short circuit occurs, power loss on large power transistor is not very high, it can not cause any damage to the unit. But there is still power loss when short circuit, in order to reduce aging and energy consumption, so this situation should be find as soon as possible and turn off power then exclude the faults. 2.4.2 After operating, put the unit in a dry place of good ventilation, and keep it clean. If it is not in use for a long period, pull off the power supply plug for storage. 2.4.3 For maintenance input voltage must be cut off. 2.4.4 The faults may be caused by the improper operation or abnormal operating ambient and component failure inside the unit. When the faults occur, the output voltage maybe exceed max Rated output voltage. Take care when operation and avoid unnecessary damage of load. 2.4.5 For safety operation, the 3-pin ground terminal of power cord must be grounded securely. 3. Accessories 3.1 Instruction manual 1 copy 6