- Six Lamp Flat Profile Design Description HFA series high-bay fluorescent fixture is a great energy saving alternative to traditional HID highbay fixtures. This fixture operates six lamps and as a standard feature comes equipped with Howard ballasts. Proudly Benefits Designed & Assembled IN THE USA* Applications Warehouse Manufacturing Facility Gymnasium Cafeteria Auditorium Features Easy access to wiring compartment & ballast Access plate provides access to electrical wiring with-out the need to open the fixture Knock-outs for easy electrical wiring and assembly Factory Installed Occupancy Sensor option Factory Installed Emergency ballast option Lamp Installation option available Multiple power cord set options, (voltage, length, gage) Pendant mount kit provides a top J-box to simplify HID retrofit installations. Can be used with a hook or rigid conduit and fasteners (Fixture must be specified with J option) Door and lens kit options available Choice of 86% Standard Specular Aluminum Reflector, 95% Specular Enhanced Aluminum Reflector, 95% Enhanced Specular Aluminum Enhanced Performance or 9% White Reflector Heavy Duty pre-painted steel construction Factory Installed Wireguard option Custom configurations available Can be easily mounted by a single person Suspended or Pendant mounting insures a quick painless install Chain and V-Clip Hanging option Wire cable hanging option. UL Listed for Damp Locations *Foreign and domestic components. Energy Saving Compared to HID systems Exceptional Color Rendering High System Efficacy Long Lamp Life Instant On/Re-strike Capability Howard Ballast and Howard Lamp as a system is covered by Howard Industries Warranty Quality Lamp holders Computer Designed Reflectors System Designed, Approved, Manufactured, and Tested by Howard Industries in Mendenhall Mississippi. Compliant with Safety and performance standards. Cable hanging Holes for V clip & chain hanging Factory Installed Option J Pendant Mount Kit (PMK2) installs from the outside: no need to open the fixture Access plate 3.8 9.87 5 Reflector Assembly pivoted open after removal of 2 screws. Pendant Mount lances included only if Factory Installed Option J is selected. Optional: /4 turn fasteners offer toolless access to the ballast compartment without removing lamps. Simply rotate the two /4 turn fasteners. See Factory Installed Option Q for more information. (toll free) 800.956. (direct).422.0033 (fax).422.2
- Six Lamp Flat Profile Design Ordering Information Model Family Reflector No. of Lamps Lamp Type/ CRI/CCT Ballast Input Volts Factory Installed Wattage () Options Cordset Options (see customer service for other cordset options) HFA E 6 32 A SE MV 000 00 0 I HFA E: Enhanced Specular Aluminum (95%) F: Enhanced Specular Enhanced Performance (95%) A: Specular Aluminum (86%) W: White reflective (9%) 6 T8 Lamps : FT8 32: F32T8 T5 Lamps :FT5 : FT5HO CRI CCT A: No Lamps B: C: D: E: F: G: H: I: J: K: L: M: N: 00 400 00 00 400 00 00 00 400 00 High Lumen T8 T5 SE: SBF High Eff(2) HE: HBF High Eff (2) LE: LBF High Eff (2) P8: PRS T8 (2) PS: PRS T5 MV: 20-277v A: 0-277 (3) MV: 20-277v HV: 347-0v (T5HO) 000: No FIOs A: Occ Sensor (4) B: Emergency Ballast (5) C: Door W/Lens & Safety Cable (6) D: Door W/Lens (6) G: Wireguard I: Special Wiring Instructions J: J-box config. (7) W: Gymnasium wire guard door and lens (8) 00: Standard Disconnect 0: 6 SJT 8/3, no plug 02: 0 SJT 8/3, no plug 03: 6 SJT 8/3 L5-5, twist lock 20v 04: 0 SJT 8/3 L5-5twist lock 20v 05: 6 SJT 8/3 5-5non twist lock 20v 06: 0 SJT 8/3 5-5non twist lock 20v 07: 6 SJT 8/3 L7-5 twist lock 277v 08: 0 SJT 8/3 L7-5 twist lock 277v 09: 6 SJT 7-5 non twist lock 277v 0: 0 SJT 7-5 non twist lock 277v : 6/3, no plug spec len 2: 6/4, no plug spec len 6: 6 SJT 8/3 7-5, non twist lock 277v 7: 8/3, no plug spec len 8: 6 STW L8-20, twist lock 0v 9: 0 STW L8-20, twist lock 0v 20: 6 SJT 8/3 L5-5, twist lock 20v 2: 6 SJT 8/3 L5-5, twist lock 277v T B A Pack. I: Single B: Bulk () Lamp installation available. (2) High Efficiency ballasts are CEE Listed. (3) Step-down autotransformer. Allows hook-up of standard MV ballast to 0v. (4) Occupancy Sensors should be used with programmed rapid start ballasts for maximum lamp life Standard Occupancy Sensor requires neutral wired fixtures (ex. -20v or -277v). For phase-to-phase voltage applications (240v) advise Customer Service at time of request. (5) Please specify Emergency Ballast (20-277v only) lumen requirements at time of request. (6) Standard acrylic prismatic, pattern 2, 0.00 thick. Call for options. (7) Unless otherwise specified, fixture will include field installed J-box. Supply wires will exit the center of the fixture, not the access plate. J-box can be installed without entering the fixture. (8) Gymnasium wire guard with door and lens is a rough service option that provides 3 inches of space between wire guard and lens offering additional protection in a gymnasium application. This option is best ordered with factory installed lamps. SE HE LE PS P8 Standard Ballast Factor High Efficiency Instant Start T8 Ballast High Ballast Factor High Efficiency Instant Start T8 Ballast Low Ballast Factor High Efficiency Instant Start T8 Ballast Program Rapid Start T5 Ballast Program Rapid Start High Efficiency T8 Ballast Sample Ordering Number: HFA E 6 32 A SE MV 000 00 I Enhanced Specular Aluminum Reflector 6-lamps (none installed) F32T8 Standard Ballast Factor High Efficiency Ballast Multi-volt (20-277v) No Factory Installed Options No Cordset Single Packaging RAPID SHIP MODELS AVAILABLE FOR NET DAY SHIPMENT HFAA632AHEMV000000I HFAA4APSMV000000I HFAE632AHEMV000000I HFAE4APSMV000000I (toll free) 800.956. (direct).422.0033 (fax).422.2
Field Installed Options Ordering HFA-WG Wire Guard HFA-WCH Wire Cable Hanging Kit (2 pcs per kit) HF-2CV (2 foot) HF-3CV (3 foot) Hanging Chain & V-clips HF-SK Stabilizer Kit (Hub, color and wire cable) HF-PMK2 Pendant Mount Kit with.0 diameter through hole Energy Cost Estimator Hours burned per year Cost per kwh$ Existing System New System 400W MH Highbay HFAE632ASE High Eff Standard BF Fluorescent Highbay 68 Number of Fixtures 0.2 Watts per Fixture (existing Energy Cost Estimation Energy used per year (existing Number of Fixtures 8 Watts per Fixture (new 222 $240 Energy used per year (new $6 Energy saving per year (per fixture) $2 52% Annual Savings $200 $ $00 $24.00 $ $0 $240 $24 Existing System New System Howard Industries provides this tool to examine the potential impact of lighting decisions. This tool provides an ESTIMATE only. The analysis of this tool does not warrant or guarantee the actual costs or savings that will be realized as the analysis suggested. You can find the full version of this cost saving tool at the Howard Lighting Website www.howardlightingproducts.com. Click Cost of Ownership Calculator. Copyright (c) 2008 Howard Industries All Rights Reserved. (toll free) 800.956. (direct).422.0033 (fax).422.2
Photometric Data - 6 Lamp T8 (HFAE632) Candela Polar Plot Luminaire Efficiencies* Reflector Type T8 Enhanced Specular 9% Specular % White 86% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. Zonal Lumen Summary Zone Lumens %Lamp %Fix 0-62.84 26.20.90 0-40 94.96 40.80.90 0-7.00 67. 74. 0-90 5786.34 90. 00.00 0-80 5786.34 90. 00.00 HFAE632 Test Report: HFAE632.ies Spacing Criteria (0-80):.26 Spacing Criteria (90-2): 0.92 Spacing Criteria (Diagnonal):.4 Maximum Candela = 6783.9 Located at Horizontal Angle = 0, Vertical Angle = 5 # = Vertical Plane Through Horizontal Angles (0-80) Through Max Cd. #2 = Vertical Plane Through Horizontal Angles (-225) #3 = Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.) Coefficients of Utilization - Zonal Cavity Method Luminance Data (cd/sq.m) Angle In Degrees 0-deg -deg 90-deg 07 6669 6 55 98 5974 640 874 6262 8420 79 8056 89 56 55 47 Effective Floor Cavity Reflectance 0.20 RC 80 0 0 RW 0 0 0 0 0 0 0 08 08 08 08 05 05 05 05 0 0 0 97 97 97 93 93 93 9 98 93 89 95 9 87 84 87 84 8 83 8 78 80 78 76 74 2 89 8 74 69 86 79 73 68 76 7 66 73 68 66 63 6 3 8 7 63 57 78 69 62 56 67 55 64 59 62 57 5 4 74 63 55 62 59 53 47 57 5 47 55 46 5 68 56 42 66 55 42 53 46 4 52 46 4 40 6 63 5 37 6 42 37 4 47 4 40 34 7 59 46 33 57 46 33 37 32 37 32 42 32 8 55 42 29 53 42 34 29 4 34 29 33 29 33 29 27 9 5 32 27 3 27 3 26 37 3 26 26 24 0 29 24 47 29 24 29 24 34 24 33 24 22 (toll free) 800.956. (direct).422.0033 (fax).422.2
Photometric Data - 6 Lamp T5 (HFAE4) Candela Polar Plot Luminaire Efficiencies* Reflector Type Enhanced Specular Specular White T5 94% 89% 89% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. Zonal Lumen Summary Zone Lumens %Lamp %Fix 0-87. 27.6 29.3 0-40.73.9 46.6 0-8..7 77. 0-90 34. 94.4 00.00 0-80 34. 94.4 00.00 Luminance Data (cd/sq.m) HFAE4 Test Report: HFAE4.ies Spacing Criteria (0-80):.24 Spacing Criteria (90-2):.4 Spacing Criteria (Diagnonal):. Maximum Candela = 05.7 Located at Horizontal Angle = 22.5, Vertical Angle = 5 # = Vertical Plane Through Horizontal Angles (22.5-202.5) Through Max Cd. #2 = Vertical Plane Through Horizontal Angles (-225) #3 = Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.) Angle In Degrees 0-deg -deg 90-deg 70 26 55 37 5 64 5 0678 26 279 20 53 89 7 5 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 RC RW 80 0 0 0 0 0 0 0 0 0 2 2 2 2 0 0 0 0 05 05 05 00 00 00 96 96 96 94 02 97 93 89 99 95 9 88 9 88 87 82 84 82 80 78 2 93 78 90 83 77 80 74 76 68 74 67 3 67 82 73 66 64 59 68 62 6 57 55 4 78 66 5 57 5 63 56 53 47 5 59 5 56 53 47 4 6 66 64 53 5 42 7 62 4 40 47 40 34 34 34 32 8 57 37 3 56 3 3 42 3 40 29 9 4 33 52 4 33 33 32 37 32 26 0 3 26 26 37 25 25 29 25 24 (toll free) 800.956. (direct).422.0033 (fax).422.2
Photometric Data - 6 Lamp T5 (HFAF4) Candela Polar Plot 225 988 625 Luminaire Efficiencies* Reflector Type T5 Enhanced Performance 94% *Luminaire efficiency is the ratio of light output emitted by the luminaire to the light output emitted by its lamps. 3 63 Zonal Lumen Summary Zone Lumens %Lamp %Fix 0-9.82 3. 33.2 0-40 4747.32.2 52.5 2 0-2.7 79.2 84.6 0-90 094.87 93.6 00.00 0-80 094.87 93.6 00.00 HFAF4 Test Report: HFAF4.ies Spacing Criteria (0-80):. Spacing Criteria (90-2):.8 Spacing Criteria (Diagnonal):. Maximum Candela = 22.6 Located at Horizontal Angle = 67.5, Vertical Angle = 5 # - Vertical Plane Through Horizontal Angles (67.5-247.5) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles ( - 225) # 3 - Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.) Luminance Data (cd/sq.m) Angle In Degrees 0-deg -deg 90-deg 625 863 00 55 53 8834 75 3222 63 62 9564 4225 3279 6 68 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 RC 80 0 0 RW 0 0 0 0 0 0 0 09 09 09 09 04 04 04 00 00 00 96 96 96 94 03 99 95 92 00 97 94 9 93 90 88 89 87 86 84 83 8 2 94 87 8 77 92 86 80 76 82 78 74 79 76 76 73 7 69 3 87 77 84 76 69 64 73 68 63 7 66 62 68 64 6 59 4 80 69 62 56 78 68 6 55 66 59 55 64 62 57 53 5 5 74 62 6 59 53 52 47 56 5 47 6 68 56 67 56 47 42 52 46 42 5 46 42 40 7 63 5 62 5 42 37 47 4 37 8 59 47 34 46 34 34 34 34 32 9 55 3 3 42 3 4 3 40 34 29 0 52 40 33 5 40 33 32 32 37 32 26 (toll free) 800.956. (direct).422.0033 (fax).422.2