The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

Similar documents
Spray Clean 606T-2 Installation Instruction

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEMA Pro-Fill I Sink Dispenser

DEMA Pro-Fill II Sink Dispenser

Spray & Foam Dispenser Item #

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

PeroxiDraw Dispenser

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

665 Series Dispenser. Metering tip kit

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

I Button Chemical Dispenser. Overview. Installation Instructions

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Certo Chemical Dilution System

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

D EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2

SAFETY INFORMATION & INSTRUCTION MANUAL

Intended Use: Explanation of Signal Word Consequences

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

DART Ware Wash Speed Control

Trident Laundry Chemical Delivery System

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

Items # and #

Trapper Drain Maintenance/Odor Control Chemical Dispensing

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

DEMA Nitro for Europe Ware Wash Chemical Dispensing

Tools Needed for Mounting Cleá Filling Station

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

DEMAMaster TM DM-811 Series Installation Manual

DEMA SQUIRT DRAIN UNIT

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing

SAM SPARTAN ACCURATE MEASURE DISPENSING SYSTEM INSTALLATION INSTRUCTIONS MODEL 681-3SAM 1. PARTS: A. SAM

PROMAX INSTRUCTION MANUAL

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

BLACK SHADOW SERIES DISPENSER. Tools Needed for Mounting SCS Dispenser Hammer Drill with 1/4, 1/8, 9/32 and 5/32 Diameter Bits Pliers

Caution! Pg. 1 of 5 I-932

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

ICS Integrated Cleaning System. Rechargeable Battery

910 BHF OWNER S MANUAL. Pg. 1 of 9

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

BIOACTIVE SOLUTIONS AC DRAIN STATION

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

AQUA-LAB AX, BX, TX. CHEMICAL DISPENSING SYSTEM User Manual REV A reva0717

Reference Manual FM-200 Series

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

123 Industrial Loop Road Paynesville, MN Phone:

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

Compact Cleaning System

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

MODEL: ATVBK-710 BEFORE RETURNING THIS PRODUCT FOR ANY REASON, PLEASE CALL

USER MANUAL MODEL NUMBER: SP-WC AND RELATED UNITS

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Car Wash / Pressure Washer

VSP SERIES Installation, Operation and Maintenance Manual

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

TRIPLE FOAM INSTALLATION MANUAL Part # FOAMSTRMRTPL00X

HALLMARK INDUSTRIES INC

DIRECT-DRIVE PRESSURE WASHERS

PPM EO-100 TM. Operation Manual

(Airgap)

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

1600 PSI ELECTRIC PRESSURE WASHER

WORKHORSE PSE. Assembly / Operation Instructions / Parts

Wall Mounted Foam Unit MD20016 USER MANUAL

DODGE DART 1.4L I-4 C.A.R.B. E.O. # D

Transcription:

Overview The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse. The unit features three ball valves for control of the water through the unit. The inlet and outlet connections are standard garden hose thread connections (3/4 Garden Hose Threads). Warnings All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicting tee. ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS. I-803 Page 1 of 8

Packing List Mounting Screw (4) Select-O-Matic Wall Anchor (4) Tubing & Foot Strainer Assembly (2) with Ceramic Weights (2) Metering Tip Kit (1) Chemical Labels (1) 25 ft. HD garden hose with ring guard Spray gun Foam Wand Hose bracket Operational Requirements Operating Water Pressure: Flow Rate: Maximum Chemical Suction Height: Water Temperature: 20 psi to 120 psi (1.38 bar to 8.25 bar) ~2.8 gallons/minute (10.6L/M) 6 feet (2 meters) Up to 150ºF (65ºC) Overall Size I-803 Page 2 of 8

Installation Instruction 1. MOUNTING THE SPRAY CLEAN: 1. Prepare the Spray Clean Site. a) Ensure that the Spray Clean intake and outlet ports can reach the supply and outlet hoses. b) The Spray Clean should be positioned no more than 6 ft (2 m) above the liquid chemical container. 2. Screw the Spray Clean Base into a wall or any stable vertical base using the screw and anchor kit provided. 3. Mount the unit on a vertical surface using the six screws & anchors provided through the mounting holes in the base. Drill all of the holes into the wall using a ¼ diameter bit for use with #10 screws & anchors. If mounting the Select-O-Matic to wood and do not plan to use the included anchors, drill 1/8 diameter holes. 4. Connect the discharge hoses to the outlet garden hose fitting. Spray guns, spray nozzles or foaming wands may be used on the hose outlets. 2. INSTALLATION: The water inlet is equipped with a female garden hose fitting. The fitting may be removed to permit direct connect to a 3/8 NPT pipe connection. Water supply pressure should not exceed 125 psi. Water temperature must not exceed 160 F. 1. Position the liquid chemical containers no more than 6 ft beneath the unit and not positioned above the unit. 2. Measure the amount of Tubing you will need to connect from the chemical containers to the injectors and cut to length. 3. Check to insure that the suction tube is not bent. 4. Put the strainer end of the tube into the chemical container, put the ceramic weight on the tubing, and attach the other end to the Injector. 5. Hoses, spray guns and foam wands are available through Dema. See the parts list on page 5, under Optional Accessories for various styles. Operation Instruction 1. OPERATION: a. To operate the Spray Clean, ensure the water supply is turned on within the pressure and temperature range stated above. b. Select which chemical or the water rinse you are using, make sure to only have one of the valves open at one time. c. On the outlet connection make sure your hose is not longer than stated below in the Table 1. If a nozzle is placed on the hose make sure it is not less than 4 GPM at 40 PSI. Table 1 HOSE I.D. 3/8 1/2 5/8 MAX. LENGTH 15 FT. (4.5 M) 50 FT. (15 M) 100 FT. (30 M) d. The chemical feed rate is controlled by metering tips which were included with the unit. The following table shows the various induction rates for differing viscosities of chemical with different metering tips. I-803 Page 3 of 8

WARNING USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. e. Place the chemical container in a convenient location not more than 6 ft. below the Select-O -Matic. (Greater lifts will reduce injection capabilities). The top of the container should not be above the Select-O-Matic. Slip a ceramic weight over a chemical supply tube and slide it against the foot strainer. Cut the vinyl tube to any convenient length that will allow the tubing to reach the bottom of the container. Drop the tubing end with the strainer and ceramic weight into the chemical container. Push the other tubing end over the chemical inlet barb located on the side of the unit. Note: Spartan Select-O-Matic comes with preset tips for Inspectors Choice and Sani-T-10. Refer to Tables 2 thru 5 to select metering tips for other products before attaching tubing to the Select-O-Matic. TABLE 2 TABLE 3 Product: Inspector s Choice Product: Sani-T-10 Tip Color Tip No. Ratio Oz./Gal. Note Tip Color Tip No. Ratio Oz./Gal. Note Purple 12 21:1 6.00 Installed Lime Green 17 531:1 0.26 Installed Grey 13 14:1 9.00 Turquoise 2 171:1 0.75 No Tip 9:1 14.00 White 7 64:1 2.00 TABLE 4 Product Tip Color Tip No. Ratio SC-200 None 11:1 Tough on Grease Purple 12 16:1 SNB-130 Yellow 10 29:1 DFP-32 Yellow 10 32:1 f. The Select-O-Matic permits the operator to select one of two chemicals or clear water rinse by opening and closing the appropriate ball valve. Only one valve should be opened at any time. If two valves are opened simultaneously, the injector may not induct chemical. When using a spray gun or foaming wand make sure that the gun on the end of the hose is in the full open position when inducting chemical. I-803 Page 4 of 8

Metering Tip Color TABLE 5 METERING TIP SELECTION CHART FLUID DILUTION RATIOS WITH METERING TIP KIT (100-15K) Injection Rate for Viscosities Shown 1 cps 75 cps 200 cps Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Tan 0.40 320-1 0.25 512-1 0.20 640-1 Orange 0.50 256-1 0.35 366-1 0.25 512-1 Turquoise 0.70 183-1 0.50 256-1 0.35 366-1 Pink 0.95 135-1 0.65 197-1 0.45 284-1 Clear 1.30 98-1 0.80 160-1 0.55 233-1 Brown 1.50 85-1 0.90 142-1 0.60 213-1 Red 1.90 67-1 1.00 128-1 0.70 183-1 White 2.20 58-1 1.30 98-1 0.80 160-1 Green 2.60 49-1 1.50 85-1 0.90 142-1 Blue 3.20 40-1 1.75 73-1 1.00 128-1 Yellow 4.85 26-1 2.25 57-1 1.10 116-1 Black 6.50 20-1 2.40 53-1 1.15 111-1 Purple 9.20 14-1 2.70 47-1 1.20 107-1 Gray 10.40 12-1 2.85 45-1 1.25 102-1 No Tip 12.80 10-1 3.50 37-1 1.55 83-1 All injection ratios are based on 40 PSI inlet water pressure and a water flow rate of 2.8 GPM. Note: Leaner dilutions are available using DEMA metering tip kit #100-15KU or capillary tip #44-61P Troubleshooting Be sure to turn off water supply before servicing PROBLEM CHECK SOLUTION Unit fails to draw chemical 1. Is more than one valve open? 2. Is the outlet hose being used too long? 3. Is the metering tip blocked 4. Is the hose kinked? 5. Is the gun or nozzle sized properly? 6. Is the spray gun fully open? 1. Close all valves but the one being used. 2. Check Table 1 on page 3 to see proper length needed. 3. Remove metering tip and clear blockage. 4. Undo the kink in the hose and check for other obstructions 5. Take the gun or nozzle off and turn the water back on to see if it will draw chemical. Unit stops drawing chemical 1. Is the foot strainer clogged with chemical or other debris? 2. Is the spray nozzle partially clogged? 3. Is the metering tip blocked? 4. Is the injector check valve blocked? 1. Removed the foot strainer and clean it 2. Removed the spray nozzle and clean it. 3. Removed the metering tip and clean the blockage. 4. Remove the plastic metering knob from the injector to inspect the check valve ball, spring, and o-ring. I-803 Page 5 of 8

Removing and replacing injectors 1. Remove the ball valve handles, the plastic cover, the 2 chemical inlet tubes, and the inlet and outlet hoses. 2. Using a Phillips screwdriver, remove the 5 screws holding the manifold onto the base. NOTE: Before continuing, injectors that fail to draw chemical because of hard water deposits can be cleaned by soaking entire manifold in a lime-removing solution. 3. Grab the upper and lower rectangular plastic pieces and pull them apart. 4. Unscrew both injector and adapter assemblies. 5. Unscrew the adapter from each injector, apply pipe dope to the threads of the new injector, and screw the adapter onto the replacement injector noting that the flow arrow of the injector must point toward the adapter. 6. Screw the new injector/adapter assemblies onto the ball valves using pipe dope. Note that the barbs of the metering knobs must point to the outside. (see page 4 of 5) 7. Grab each manifold again, and lining up the holes in the manifold with the adapters and the center pipe, shove them together. 8. Replace the 5 screws that hold the manifold onto the base. If the screws do not thread into the base, either push together or pull apart the manifolds slightly until they do line up. 9. Push the chemical tubes onto the two injector barbs, replace the cover, and replace the ball valve handles, making sure that they are in the horizontal position and the arrows point to the left. 10. Replace the inlet and outlet hoses. CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE. WATER INLET CHEMICAL VALVE #1 CHEMICAL VALVE #2 METERING TIP LOCATION METERING TIP LOCATION CLEAR RINSE WATER\CHEMICAL SOLUTION OUTLET (GARDEN HOSE CONNECTION) CLEAR VINYL SUCTION TUBE CERAMIC WEIGHT FOOT STRAINER CLEAR VINYL SUCTION TUBE CERAMIC WEIGHT FOOT STRAINER I-803 Page 6 of 8

Parts list Parts list NO. QTY DEMA NO. DESCRIPTION 1 1 63-32-2 WATER INLET 2 1 60-60 BALL VALVE W/HANDLE 3 1 INJECTOR P203CTC INJECTOR P203CTC INJECTOR BREAKDOWN 1 9 2 P203CTC 4 5 6 7 8 3 NO. PART NO. DESCRIPTION 1 24-67 Screw (4 Required) 2 100-15- Metering Tip (Specify Color) 3 24-62-SP Check Valve Repair Kit 4 25-25S O-Ring, 7/32 X 11/32 X 1/16 (Silicone) 5 24-24P Check Valve Ball (Teflon) 6 24-23-2 Check Valve Spring 7 24-34-7 Check Valve Core 8 25-29S O-Ring 3/8 X 1/2 X 1/16 (Silicone) 9 100-15K Metering Tip Kit I-803 Page 7 of 8

VENT 8 OPTIONAL ACCESSORIES INLET 1 2 3 4 5 6 7 NO. QTY DEMA NO. SPARTAN STOCK PARTS DESCRIPTION 1 1 292QD 9185 FOAM WAND 2 1 40-14QD HEAVY DUTY SPRAY GUN W/DISCONNECT 3 1 40-14HD 9578 SPRAY GUN 4 1 44-3 9185 HOSE (BLACK) 1/2" ID X 25" LG. 5 1 44-3RG HOSE (RED) SPRING GUARD 1/2" ID X 25" LG. 6 1 40-14HD HOSE (WHITE) 1/2" ID X 25" LG. 7 1 44-89 BACK FLOW PREVENTER (A.S.S.E.1012) 8 1 9573 SPRAY GUN W/FOAM WAND Warranty Merchandise Returns No Merchandise will be Returned for Credit Without DEMA S Written Permission. Returned Merchandise Authorization Number is Required in Advance of Return. Product Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as o -rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See Merchandise Returns above). I-803 Page 8 of 8