MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue

Similar documents
World Super Series WSS The extensive breaker series from Mitsubishi Electric

MITSUBISHI NO-FUSE BREAKER NF125-SGW MODEL. In A Ir A 3P Uimp 8kV. 40 C Ue. Icu/Ics 690VAC. 8/8kA 525VAC. POLE Ui690V Cat.A.

Intelligent Breaker Technology of the Next Generation. WSS, PSS, SS Series A MITSUBISHI ELECTRIC

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers

Series MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS 07 A EC97J1128

LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS

cor Long Run Experience

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

3 - Protection components Motor circuit-breakers

Molded Case Circuit Breaker

Moulded case circuit breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Memshield - ACB Ratings & Specifications

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Low voltage circuit breakers

01 Spectra Plus - Introduction

Low voltage moulded case circuit breaker EB2

DPX 1600 Electronic release

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

3VU13, 3VU16 Circuit-Breakers

DPX earth leakage DPX 3 -I earth leakage

MCCB Accessories to suit AF

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Low voltage circuit breakers

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DMX 3 -I 2500 switch disconnectors

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX moulded case circuit breakers

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Moulded Case Circuit Breakers

ACS motor protection circuit breakers KT 7 Introduction

DPX 630 Electronic release

18-I73E CAT REF.

D509E. Manual Motor - Starters


and other modular devices for low voltage installation

MITSUBISHI ELECTRIC. Low Voltage Switchgears Magnetic Contactors Thermal Overload Relays Contactor Relays MS-N. Technical Catalogue

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

MOULDED CASE CIRCUIT BREAKERS BC160N


Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

LOW VOLTAGE SWITCHGEAR

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

15-I73E CAT REF.

DPX Electronic + earth leakage

DPX Magnetic only

Air Circuit Breakers

Selection Guide Motor Control Device Solutions

3VT Kompaktleistungsschalter bis 630A

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

14-I73E CAT REF.

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Air Circuit Breakers

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

MS General Information Extended Product Type: MS

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Micro Contactor MA Series

Product Line Overview. The Most Logically Designed Contact Assembly

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Phase + Neutral, neutral on right side

Control Circuit Protection

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Phase + Neutral, neutral on left side

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

ACW Molded-Case Circuit Breaker UL 489 Listed

Technical Data Accessories MCBs Ex9B.

Innovators in Protection Technology. TemBreak. Total Protection, Complete Control. Catalogue No I20E

Motor Protection Circuit Breakers

Low voltage moulded case circuit breaker EB2

Molded Case Circuit Breakers H series General information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

North American Edition Super Solution Low voltage circuit breakers

Protection components

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

Interruption Technology of Breakers for High-voltage Direct Current

General data 5/37. Overview

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

DRX 250 B/N/H Circuit breaker (not adjustable)

AF series contactors (9 2650)

MINIATURE CIRCUIT BREAKER

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Wall mounted switchgear

max pole for t=15 ms

Series KTU7 UL489 Molded Case Circuit Breakers

Transcription:

Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors WSS, PSS & Super Series A 100 A Technical Catalogue 2004

Circuit Breakers Circuit Breakers The new World Super Series WSS completes the wide range of circuit breakers from. Switch over to highest performance S/H types TheS/Htypesarethestandardtypewhichhaveawiderangeofrating current and high breaking capacity. Rated currents 100 A, adjustable from 1 A up to 100 A. R/U types Highest breaking capacities up to 200 ka at 500 V is obtained with type NF-UGW. The I CU value is 100 % the I CS value (IEC/EN 094-2). Ctypes Low-cost, low fault level range offers significant cost savings. From 400 to 0 A ratings there are adjustable solid state types. DSN types Standard S type MCCBs without the automatic tripping element with switching capacity which is times the rated current I N. Further Publications within the LVS, PLC and inverter range Technical Catalogues SUPER AE Technical Catalogue Product catalogue for air circuit breakers from 1000 A to 00 A rated current (art no. 209) MS-N Technical Catalogue Product catalogue for low voltage contactors and relays from 20 A to 1000 A rated current (art no. 20) PLC and Inverter Technical Catalogues Product catalogues for programmable logic controllers and frequency inverters (more details on request) Additional Services Current information on updates, alterations, new items, and technical support you will find on 's web pages (www.mitsubishi-automation.com). IntheproductssectionoftheMITSUBISHIhomesitevariousdocumentationsofthewholeproductrangebyMITSUBISHIELECTRICaswellasthe current version of this catalogue on hand are available as download. The content is updated daily and to date is provided in German and English. About this product catalogue Due to the constantly growing product range, technical alteration, and new or changed characteristical features, this catalogue is updated frequently. Texts, figures and diagrams shown in this product catalogue are intended exclusively for explanation and assistance in planning and ordering the Moulded Case Circuit Breakers ans Disconnectors of the WSS, PSS and SS series and the associated accessories. Only the manuals supplied with the breakers are relevant for installation, commissioning and handling of the circuit breakers and the accessories. The information given in this documentation must be read before installation and commissioning of the modules. Should questions arise with regard to the planning of modules described in this product catalogue, do not hesitate to contact the german branch of the EUROPE B.V. in Ratingen or one of its distributors (see cover page). EUROPE B.V. 01/2004 (4th edition) 2 WSS, PSS & SUPER SERIES

CTENTS WSS, PSS & SUPER SERIES SYSTEM DESCRIPTI AND OVERVIEW Circuit Breakers........................................................................................... 4 Electronic Breakers........................................................................................ Calculation and Selection Software MELSHORT2............................................................ Product Skeleton of Accessories........................................................................... Model Overview and Specifications....................................................................... 10 CIRCUIT BREAKERS Specifications of Moulded-Case Circuit Breakers........................................................... Specifications of Switches / Disconnectors................................................................ 20 Order information of Circuit Breakers..................................................................... 22 INTERNAL CESSORIES Introduction and Installation............................................................................. 24 Alarm Switch and Auxiliary Switch........................................................................ 2 Shunt Trip Device........................................................................................ 2 Undervoltage Tripping Device............................................................................ 0 EXTERNAL CESSORIES Accessories for Connection and Installation............................................................... 4 Operating Handles....................................................................................... 5 Electrically Operated Breakers............................................................................ Handle Lock Devices..................................................................................... Terminal Covers......................................................................................... 9 Mechanical Interlocks, Insulating Barriers, Rail Adapter.................................................... 40 Tester for Electronic Breakers............................................................................. 41 Measuring Display Unit.................................................................................. 41 OPERATI CHARTERISTICS Pre-Alarm............................................................................................... 4 Moulded-Case Circuit Breakers........................................................................... 4 DIMENSIS Circuit Breakers and Disconnectors....................................................................... 49 Accessories............................................................................................. 59 APPENDIX Order Form.............................................................................................. 2 Index.................................................................................................... WSS, PSS & SUPER SERIES

POLE Ui90V Cat.A P PUSH TO TRIP 4 5 0.5 2.5 100 100 2 T Ip Is TL Ii Ts Ii(X100A) 10.1.2. 4 14 Ir IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V 00V 0% PAL OVER EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA 20/20kA POLE Ui 90V 50-0Hz kv Uimp PUSH TO TRIP T Ip Ir Is P TL Ii Ts TEST 0 JIS Ue 550V 40V 220V IEC 094-2 EN 094-2 500V 250V Icn 5kA 50kA 5kA Icu/Ics 10/10kA 0/0kA 42/42kA 45/45kA 5/5kA 40 C 50kA 5kA 00 250 4 5 10 50.5 220 2.5 14 200 400 2 10 4 1 Ir(A) IS(xIr).1.2 100.0. Ii(X400A).0.10 Ip(xIr) PUSH TO TRIP TEST TERMINAL OVER CURRENT 0.9 0. 4 5.5 0. 2.5 0.5 1.0 2 10 G 0.1 0.2 S 0 0. TL IR (xir) sec. TS c d b e Hi a Lo Ii IEC094-2 Icu/Ics 90V 25/1kA 500V 5/kA 440V 5/4kA 400V 5/4kA 20V 5/kA Cat. B Icw 20kA 0.1s SYSTEM DESCRIPTI AND OVERVIEW WSS, PSS and SS The Extensive Breaker Series from Mitsubishi Electric The circuits of the Mitsubishi breaker series are amongst the smallest compact circuit breakers in the world with electronic overload indication of this kind. The system is based, among other things, on the well-known and proven microprocessor technology. MITSUBISHI NO-FUSE BREAKER NF5-SGW 100 In A Ir -100A Uimp kv MITSUBISHI NO-FUSE BREAKER NF400-SEP 400A 400 MITSUBISHI NO-FUSE BREAKER NF1000-SS 1000 In A Ir 500-1000A EN094-2 Ue RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) 10.0.0.10 TL(sec) TS(sec) IS (xin) NF250-SGW RE, p NF400-SEP, p NF1000-SS, p WSS World Super Series The new WSS breaker series meets national and international protection ratings according to VDE, EN, and IEC standards for industrial applications as well as for extended shipping demands. The new tripping technology guarantees a high reliability and highest protection. 1 to 250 A in one model size (- and 4-pole) interchangeable relay unit (thermal type or electronic type) available in fixed and plug-in versions breaking capacity Ics = 100 % Icu, up to 90 V PSS Progressive Super Series The proven Progressive Super Series features technical know-how and the microprocessor technology tried and tested in longstanding experience. The fully enclosed circuit breakers provide an increased safety and at the same time decreased switching times. 400 to 0 A 2 model sizes (- and 4-pole) electronic trip system available in fixed and plug-in versions additional disconnectors available SS Super Series The proven standard series for a high breaking performance providing an optimum protection for transformer and generator feed in, and output breakers. Circuit breakers can be used as section or disconnecting switch. 1000 to 100 A 1 model size (- and 4-pole) electronic trip system available in fixed and plug-in versions Intelligent Breaking Technology for Your Safety With its innovative breaking technology all Mitsubishi breakers offer greater safety and even faster circuit-breaking speed through the use of the latest switch-off technology and innovative engineering, with a newly developed electronic trip relay. ka 200 5 5 (I CU at 400 V ) UGW RGW UEP REP UR Breaking performance The complete range of moulded case circuit breakers from to100a. 5 0 HGW HEP 45 SEP SS 10,5 5 HW SW SW 2 SGW CEP 5/10/250 400/0/0 1000/50/100 AF 4 WSS, PSS & SUPER SERIES

SYSTEM DESCRIPTI AND OVERVIEW Outline New breaking technology With its new breaking technology the circuit breakers offer greater safety and even faster circuit-breaking speed through the use of the latest switch-off technology and innovative engineering, with a newly developed electronic trip relay. Arc-extinguishing device Mitsubishi MCCBs feature excellent arc-extinguishing performance by virtue of the optimum combination of grid gap, shape, and material. Magnetic flux Rapid movement Switching mechanism The contacts open and close rapidly, regardless of the moving speed of the handle, minimizing contact wear and ensuring safety. Grid Magnetic force Arc extinction Arc runner The arc is instantaneously transferred to the arc-extinguishing chamber (see the figure above) by the arc runner, which reduces damage to contacts and improves interrupting performance. Trip button (push to trip) Arc Enables tripping mechanically from outside, for confirming the operation of the accessory switches and the manual reseting function. MITSUBISHI NO-FUSE BREAKER NF5-SGW POLE Ui90V Cat.A 100 In A Ir -100A P Uimp kv PUSH TO TRIP T Ir Ip Is TL Ii Ts IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V 00V 0% EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA 20/20kA PAL Ii(X100A). 4 10.1.2 10.0.0.10 14 Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr).5 0 2.5 100 100 2 RE100 In 100A 4 5 Moulded case (cover) OVER Handle Trip indication The automatically tripped condition is indicated by the handle in the center postion between and ; the yellow or white line cannot be seen in this position. Thefigureshowsthehandleintripped position. Resetting Resetting after tripping is performed by first moving the handle position to engage the mechanism, then returning thehandletotoreclosethecircuit. Trip-Free Even if the handle is held at, the breaker will trip if an overcurrent flows. Contact on Mechanism Even in the worst case in which welding occurs owing to an overcurrent, the breaker will trip and the handle will maintaine to, indicating the energizing state. Type NF5-SGW construction T Ip Ir Is TL Ii Ts 0% Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) 0.5 2.5 2 100 100 RE100 In 100A 4 5 PAL Ii(X100A) 10.1.2 10.0. 4 14.0.10 Trip relay with control dials OVER thermal trip current value The setting can be changed by simply turning the control dials, providing the optimum characteristics for particular road conditions. WSS, PSS & SUPER SERIES 5

SYSTEM DESCRIPTI AND OVERVIEW A Microcomputer and Mitsubishi s Original IC fulfill a New High Level of Safety Safer and more reliable power Electronic device loads, such as inverters, distort the current waveform. Mitsubishi s electronic breakers use a digital detector to measure the current s effective value and minimize overload tripping errors. This enables precise protection of the circuit. Alarm function monitors and anticipates interruptions Our electronic moulded-case circuit breakers feature a pre-alarm system as standard. The pre-alarm outputs an alarm before the circuit breaker trip is activated. When the load current exceeds the set pre-alarm current, it outputs a pre-alarm signal (from a solid-state relay) and lights the LED. The pre-alarm module (with contact output) is optional with electronic molded-case and earth-leakage circuit breakers. Improved protection against fluctuations in the load current Our standard electronic trip relay offers a number of outstanding benefits. The user has a choice of six different parameters as tripping characteristics with the multiple coordinated protection method. Better protection can be obtained between the high-voltage fuse, OCR and the low voltage fuse. Time [s] Pre-alarm current I P Load current Current setting I r High-voltage fuse allowable short-time characteristic Long time-delay operating time T L Short time-delay tripping current I S Short time-delay operating time T S High voltage Low voltage MCCB Load Instantaneous tripping current I I Current [A] Coordinated protection from multiple tripping characteristics Load-current indication LED (0 %) Pre-alarm indication LED Over-current indication LED NF400-SEP, P Rated current I r Short time-delay operating time T S Pre-alarm current I P Instantaneous tripping current I I Long time-delay operating time T L Short time-delay tripping current I S Portable tester facilitates checking and maintenance The separately sold portable tester allows theusertocheckthefourcharacteristics: 1. Long-delay tripping 2. Short-delay tripping. Instantaneous tripping 4. Pre-alarm characteristics LEDs for load current, pre-alarm and over-current show the operating status. Overload protection and safety The neutral-pole overload protection circuit is standard with 4-wire electronic moulded-case devices. It prevents burn-out when the neutralpole s load current is greater than the voltage pole in a -phase 4 wire circuit which is prone to distorted third-harmonic current flows. L1 L2 L N WSS, PSS & SUPER SERIES

SYSTEM DESCRIPTI AND OVERVIEW Calculation and Selection Software MELSHORT2 MELSHORT2 The New Calculation Software for Low-Voltage Switchgear MELSHORT2 is a software package that provides all the functions needed for planning and dimensioning switchgear systems. Increasingly demanding technical specifications and accountability regulations are making switchgear configuration much more critical than it used to be. In the past, software for calculating and dimensioning switchgear was helpful nowadays it s absolutely essential. Mitsubishi Electric s MELSHORT2 is a complete software package that provides all the functions needed for successful switchgear system configuration and layout. It supports all modern international electrical engineering standards and shines with simple and reliable operation. Circuit diagram of the network to be calculated, with input field The program calculates the short-circuit levels and currents at all necessary points for all switchgear components, including the power supply transformer and circuit breakers, the emergency generators, the individual motor and capacitor group branch circuits and all the other power distribution circuits, down to the last circuit breaker. This makes it possible to select the ideal breaker for every task, for optimum performance and cost-efficiency. MELSHORT2 has a comprehensive range of powerful, easy-to-use functions, including: Selective shutdown Backup protection Coordination with the main power supply systems Allowance for the start-up currents of electric motors These functions make it possible to optimise the configuration of your switchgear equipment for the specific requirements of your applications. The calculated results, the hardware model suggestions and the wiring diagram with all the relevant values can be processed and used as documentation for the switchgear installation. Another welcome extra is the free Internet update service. Display of the trip curves of a circuit breaker in the network Specifications Operating system Disk type MELSHORT2 MS Windows 95/9/NT4.0/2000 CD-ROM Art. no. 9115 WSS, PSS & SUPER SERIES

K K2 K1 K SW1 K K1 Uc K2 K2 S2 S1 P2 P1 AUTO MANU K1 RESET PUSH TO TRIP POWER SUPPLY MODULE CTROLL CIRCUIT VOLTAGE Power Supply (TRIP) S1 S2 S4 P1 P2 Ui 90V Cat.A IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V Operating Circuit RATED CURRENT Uc 250 A SERIAL: Uimp kv EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA S4 PUSH TO TRIP MSDBA-NF25GSW A010 (MANU) Discharge 9 9 9 5V 5A 250V A DC 5V 0.4A DC 250V 0.2A 14 11 5V 5A 250V A DC 5V 0.4A DC 250V 0.2A 95 c T Ir Ip Is TL Ii Ts Ii(X100A) 4 5 10 0.5.1.2 2.5 100 100 2 10.0. 4 14.0.10 RE100 In 100A 100-240V D P D2 P2 Install and uninstall the accessory in tripped position, not in or position SHTA240-2GSWRS D1 P1 C2 S2 0% PAL OVER SYSTEM DESCRIPTI AND OVERVIEW Product Skeleton of Accessories offers a wide range of accessories for the Moulded Case Circuit Breakers and Disconnectors to serve almost all variations of applications. Detailled information on request. 1 Circuit Breaker see page 2 Relay unit RT (Thermal type) on request Relay unit RE (Electronic type) on request 4 Solderless (Box) terminals see page 4 1 5 Rear connection studs see page 4 Insulating barriers (BA-F) see page 40 Small terminal covers (TC-S) see page 9 Large terminal covers (TC-L) see page 9 14 ALARM SWITCH ALb ALc ALa 1 9 Rear teminal covers (BTC) see page 9 AUXILIARY SWITCH AXa AXb AXc 11c b 14a 9a 9b AX AL ALAX-2GSWLS 10 Plug-in base (PM) see page 4 11 Connections for Plug-in see page 4 Mechanical interlock (MI) see page 40 1 Lock with padlocks (HL) see page 15 1 14 Handle lock device (LC, HLF, HLN, HLS) see page 15 Variable-depth operating handle, V type see page 5 TRIPPED 1 Rotary operating handle, R type see page 5 RESET Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) 1 Electrical operating device (MDS) see page 1 Alarm and Auxilliary switches (AL, AX) see page 2 19 Under voltage trip device (UVT) see page 0 1 19 20 Shunttripdevice(SHT) see page 2 TRIPPED SOURCE Hi Lo 1 20 Control circuit voltage should be suppliedtop1 and P2 terminals. C1 S1 SHT P1 P2 S1 S2 S4 MITSUBISHI MDSPSA240-SW 100-240V/DC100-250V Push to Push to OPEN NO-FUSE BREAKER NF250-SGW Pull Push WSS, PSS & SUPER SERIES

( only) T Ip Is TL Ii Ts Ii(X100A) 100 90 4 5 10 0.5.1.2 2.5 5 5 100 2 10.0. 4 14 Ir.5. 0% PAL.5.9..95 1.0 OVER POLE Ui90V Cat.A P Uimp kv PUSH TO TRIP IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V 00V EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA 20/20kA T Ir Ip Is TL Ii Ts Ii(X100A) 100 90 4 5 10 0.5.5.1.2. 2.5.5 5 5 100 2 10.0. 4 14. Ii(DC)=1.XIi() 4 Ir(x5A ) 10 ( only) Ir Ii RT5 In 5A 40 C PE 200 10 250 0% PAL.9.95 1.0 Ir(A) OVER SYSTEM DESCRIPTI AND OVERVIEW 9 4 5 1 11 10 MITSUBISHI NO-FUSE BREAKER NF5-SGW 5 In A Ir 5-5A 11 2 RE5 In 5A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) RE5 In 5A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) 4 5 9 WSS, PSS & SUPER SERIES 9

SYSTEM DESCRIPTI AND OVERVIEW Model Overview and Specifications Sseries Hseries Rseries Useries Cseries Disconnectors Type / Series WSS series NF2-SW NF-SW NF5-SGW RT NF5-SGW RE NF10-SGW RT NF10-SGW RE Rated current I n max. [A] 2 5* 5* 10* 10* Rated insulation voltage U i [V] 00 00 90 90 90 90 Number of poles /4 /4 /4 /4 /4 Rated breaking capacity [ka] IEC 94-2 EN 0 94-2 VDE 00 (50/0 Hz) 90V / / / / 500 V 2.5 / 1.5 / 4 0 / 0 0 / 0 0 / 0 0 / 0 440 V 2.5 / 1.5 / 4 / / / / (I cu / I cs ) 400 V 5/2.5 / 4 / / / / 20 V.5 / 4 15 / 5 / 5 5 / 5 5 / 5 5 / 5 Dimensions WxHxD [mm] 5x10x 5/100x10x 105/140x15x 105/140x15x 105/140x15x 105/140x15x Type NF-HW NF5-HGW RT NF5-HGW RE NF10-HGW RT NF10-HGW RE Rated current I n max. [A] 5* 5* 10* 10* Rated insulation voltage U i [V] 90 90 90 90 90 Number of poles /4 /4 /4 /4 /4 Rated breaking capacity [ka] IEC 94-2 EN 0 94-2 VDE 00 (50/0 Hz) 90 V 2.5 / 1 20 / 20 20 / 20 20 / 20 20 / 20 500 V.5 / 4 50 / 50 50 / 50 50 / 50 50 / 50 440 V 10 / 5 5 / 5 5 / 5 5 / 5 5 / 5 (I cu / I cs ) 400 V 10 / 5 5 / 5 5 / 5 5 / 5 5 / 5 20 V 25 / 1 100 / 100 100 / 100 100 / 100 100 / 100 Dimensions WxHxD [mm] 5/100x10x 105/140x15x 105/140x15x 105/140x15x 105/140x15x Type Rated current I n max. [A] 100 Rated insulation voltage U i [V] 90 Number of poles Rated breaking capacity [ka] IEC 94-2 EN 0 94-2 VDE 00 (50/0 Hz) 90 V 25 / 25 NF5-RGW RT 500 V 5 / 5 440 V 5 / 5 (I cu / I cs ) 400 V 5 / 5 20 V 5 / 5 Dimensions WxHxD [mm] 105x240x Type Rated current I n max. [A] 100 Rated insulation voltage U i [V] 90 Number of poles /4 Rated breaking capacity [ka] IEC 94-2 EN 0 94-2 VDE 00 (50/0 Hz) 90 V 0 / 0 NF5-UGW RT 500 V 200 / 200 440 V 200 / 200 (I cu / I cs ) 400 V 200 / 200 20 V 200 / 200 Dimensions WxHxD [mm] 105/140x240x Type Rated current I n max. [A] Rated insulation voltage U i [V] Number of poles Rated breaking capacity [ka] (I cu / I cs ) Dimensions WxHxD IEC 94-2 EN 0 94-2 VDE 00 (50/0 Hz) 90 V 500 V 440 V 400 V 20 V [mm] Type DSN2-SW DSN-SW DSN5-SGW DSN10-SGW Rated current I n max. [A] 2 5 10 Rated insulation voltage U i [V] /DC 00 00 90 90 Rated voltage U e [V] (50/0 Hz) / DC 500 / 250 500 / 250 90 / 00 90 / 00 Number of poles /4 /4 /4 Max. switching current [A] (breaking) /DC 25 / 504 / 252 1000 / 500 / 40 Dimensions WxHxD 5x10x 5/0x10x 105/140x15x 105/140x15x DC on request When using solderless terminals: see reduced data on page 1 * adjustable 10 WSS, PSS & SUPER SERIES

SYSTEM DESCRIPTI AND OVERVIEW WSS series PSS series SS series NF250-SGW RT NF250-SGW RE NF400-SEP NF0-SEP NF0-SEP NF1000-SS NF50-SS NF100-SS 250* 250* 400* 0* 0* 1000* 50* 100* 90 90 90 90 90 90 90 90 /4 /4 /4 /4 /4 /4 /4 /4 / / 10/10 10 / 10 10 / 10 25 / 1 25 / 1 25 / 1 0 / 0 0 / 0 0 / 0 0 / 0 0 / 0 5 / 5 / 5 / / / 42 / 42 42 / 42 42 / 42 5 / 4 5 / 4 5 / 4 / / 45 / 45 45 / 45 45 / 45 5 / 4 5 / 4 5 / 4 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 / 5 / 105/140x15x 105/140x15x 140/15x25x10 210/2x25x10 210/2x25x10 210/2x40x140 210/2x40x140 210/2x40x140 NF250-HGW RT NF250-HGW RE NF400-HEP NF0-HEP NF0-HEP 250* 250* 400* 0* 0* 90 90 90 90 90 /4 /4 /4 /4 /4 20 / 20 20 / 20 10 / 10 15 / 15 15 / 15 50 / 50 50 / 50 50 / 50 50 / 50 50 / 50 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 0 / 0 0 / 0 0 / 0 100 / 100 100 / 100 100 / 100 100 / 100 100 / 100 105/140x15x 105/140x15x 140/15x25x10 210/2x25x10 210/2x25x10 NF250-RGW RT NF400-REP NF0-REP NF0-REP 225 400* 0* 0* 90 90 90 90 25 / 25 15 / 10 20 / 15 20 / 15 5 / 5 0 / 5 0 / 5 0 / 5 5 / 5 5 / 5 / 5 / 5 / 5 5 / 5 / 5 / 5 / 5 150 / 5 150 / 5 150 / 5 105x240x 140x25x10 210x25x10 210x25x10 NF250-UGW RT NF400-UEP NF0-UEP NF0-UEP NF50-UR 225 400* 0* 0* 50* 90 90 90 90 90 /4 /4 /4 /4 /4 0 / 0 5 / 5 5 / 5 5 / 5 200 / 200 10 / 10 10 / 10 10 / 10 5 / 42 200 / 200 200 / 200 200 / 200 200 / 200 5 / 5 200 / 200 200 / 200 200 / 200 200 / 200 5 / 5 200 / 200 200 / 200 200 / 200 200 / 200 10 / 5 105/140x240x 140/2x29/22x200 210/2x22x200 210/2x22x200 240/10x40x144 NF-400-CEP NF0-CEP NF0-CEP 400* 0* 0* 00 00 00 15 / 1 / 9 1 / 9 25 / 1 / 1 / 1 / 1 / 1 / 1 50 / 25 50 / 25 50 / 25 140x25x10 210x25x10 210x25x10 DSN250-SGW DSN400-SP DSN0-SP DSN0-SP DSN1000-SS DSN50-SS DSN100-SS 250 400 0 0 1000 50 100 90 90 90 90 0 0 0 90 / 00 90 / 250 90 / 250 90 / 250 0 / 250 0 / 250 0 / 250 /4 /4 /4 /4 /4 /4 /4 2000 / 1000 200 / 100 5040 / 2520 400 / 200 00 / 14000 10000 / 5000 0 / 400 105/140x15x 140/15x25x10 210/2x25x10 210/2x25x10 210/2x40x140 210/2x40x140 210/2x40x140 * adjustable WSS, PSS & SUPER SERIES 11

SPECIFICATIS Specifications of Moulded-Case Circuit Breakers 5 A Type (Reference for Order information on p. 22) NF2-SW (1) NF-SW (2) NF-HW () NF5-SGW RT (4) NF5-SGW RE (5) Frame (A) 2 5 5 Rated data Mechanical data External accessories Others Rated current I n [A] at ambient temperature 40 C, 4,, 10, 1, 20, 25, 2 Fixed, 4,, 10, 1, 20, 25, 2, 40, 50, Fixed 10, 1, 20, 25, 2, 40, 50, Fixed 1 25, 25 40, 40, 100, 5 Number of poles /4 /4 /4 /4 Rated insulation voltage U i [V] 00 00 90 90 90 Rated breaking capacity [ka] (I cu / I cs ) IEC/EN 094-2 (50/0 Hz) 90V 2.5/1 / / 500 V 2.5 / 1.5 / 4.5 / 4 0 / 0 0 / 0 440 V 2.5 / 1.5 / 4 10 / 5 / / 400 V 5/2.5/4 10/5 / / 20 V.5 /4 15 / 25 / 1 5 / 5 5 / 5 DC 00 V 20 / 20 Utilization category A A A A A Rated impulse withstand voltage U imp [kv] Pollution degree 2 2 2 Reverse connection Suitable for isolation 1 2, 2, 100, 5 5 a 5 5 / 100 5 / 100 105 / 140 105 / 140 ca a c b 10 10 10 15 15 Dimensions [mm] b c ca 90 90 90 110 110 Weight [kg] 0.55 0.0 / 0.0 0.0 / 0.0 2.0 / 2. 2.0 / 2. Cassettetype accessories Accessories connection Installation and connection Built-in accessories Alarm switch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) with terminal block (SLT) with internal terminal type Front Screw terminal (standard) Solderless terminal Busbarterminal Rear (B) Plug-in Rear (PM) Rear front IP 20 with auto trip (PM-IP) Pre-alarm-contact output (PAL) Overcurrent trip alarm (OAL) External operating Door mounting (V) handle Mounted on breaker (R) Electrical operation device (MDS) Handle lock device Terminal cover Handle lock for use with padlock (HL) (HL-S) Lock cover (LC) Large (TC-L) Small (TC-S) For rear connection (BTC) For plug-in (PTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 5 mm rail Marine approval for pole breakers LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB Automatic tripping device Hydraulic-magnetic Hydraulic-magnetic Hydraulic-magnetic Thermal-magnetic Electronic Trip button Equipped Equipped Equipped Equipped Equipped Both PAL and OAL is not available. Only one specified. Others on request. On request. Missing specifications accord. to IEC/EN 094-2 on request. WSS, PSS & SUPER SERIES

SPECIFICATIS NF5-HGW RT () NF5-HGW RE () NF5-RGW RT () NF5-UGW RT (9) 5 5 5 5 1 25, 25 40, 40, 100, 5 1 2, 2, 100, 5-5 1 25, 25 40, 40, 100 1 25, 25 40, 40, 100 /4 /4 /4 90 90 90 90 20 / 20 20 / 20 25 / 25 0 / 0 50 / 50 50 / 50 5 / 5 200 / 200 5 / 5 5 / 5 5 / 5 200 / 200 5 / 5 5 / 5 5 / 5 200 / 200 100 / 100 100 / 100 5 / 5 200 / 200 40/40 A A A A 105 / 140 105 / 140 105 105 / 140 15 15 240 240 110 110 110 110 2.0 / 2. 2.0 / 2..1.1 /.9 / / LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped WSS, PSS & SUPER SERIES 1

SPECIFICATIS Specifications of Moulded-Case Circuit Breakers 10 250 A Type (Reference for Order information on p. 2) NF10-SGW RT (10) NF10-SGW RE (11) NF10-HGW RT () NF10-HGW RE (1) Frame (A) 10 10 10 10 Rated data Mechanical data External accessories Rated current I n [A] at ambient temperature 40 C 5 10 10 5 10 Numberofpoles /4 /4 /4 /4 Rated insulation voltage U i [V] 90 90 90 90 Rated breaking capacity [ka] (I cu / I cs ) IEC/EN 094-2 (50/0 Hz) 10 90 V / / 20 / 20 20 / 20 500 V 0 / 0 0 / 0 50 / 50 50 / 50 440 V / / 5 / 5 5 / 5 400 V / / 5 / 5 5 / 5 20 V 5 / 5 5 / 5 100 / 100 100 / 100 DC 00 V 20 / 20 40 / 40 Utilization category A A A A Rated impulse withstand voltage U imp [kv] Pollution degree Reverse connection Suitable for isolation a 105 / 140 105 / 140 105 / 140 105 / 140 ca a c b 15 15 15 15 Dimensions [mm] b c ca 110 110 110 110 Weight [kg] 2.0 / 2. 2.0 / 2. 2.0 / 2. 2.0 / 2. Cassettetype accessories Accessories connection Installation and connection Built-in accessories Alarm switch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) with terminal block (SLT) with internal terminal type Front Screw terminal (standard) Solderless terminal Busbarterminal Rear (B) Plug-in Rear (PM) Rear front IP 20 with auto trip (PM-IP) Pre-alarm-contact output (PAL) Overcurrent trip alarm (OAL) External operating Door mounting (V) handle Mounted on breaker (R) Electrical operation device (MDS) Handle lock device Terminal cover Handle lock for use with padlock (HL) (HL-S) Lock cover (LC) Large (TC-L) Small (TC-S) For rear connection (BTC) For plug-in (PTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 5 mm rail Marine approval for pole breakers Automatic tripping device Thermal-magnetic Electronic Thermal-magnetic Electronic Trip button Equipped Equipped Equipped Equipped Both PAL and OAL is available. Only one specified. Others on request. On request. Missing specifications accord. to IEC/EN 094-2 on request. Others 14 WSS, PSS & SUPER SERIES

SPECIFICATIS NF250-SGW RT (14) NF250-SGW RE (15) NF250-HGW RT (1) NF250-HGW RE (1) NF250-RGW RT (1) NF250-UGW RT (19) 250 250 250 250 250 250 5 10, 10 250 5 250 5 10, 10 250 5 250 5 10, 10 225 5 10, 10 225 /4 /4 /4 /4 /4 90 90 90 90 90 90 / / 20 / 20 20 / 20 25 / 25 0 / 0 0 / 0 0 / 0 50 / 50 50 / 50 5 / 5 200 / 200 / / 5 / 5 5 / 5 5 / 5 200 / 200 / / 5 / 5 5 / 5 5 / 5 200 / 200 5 / 5 5 / 5 100 / 100 100 / 100 5 / 5 200 / 200 20 / 20 40 / 40 A A A A A A 105 / 140 105 / 140 105 / 140 105 / 140 105 105 / 140 15 15 15 15 240 240 110 110 110 110 110 110 2.0 / 2. 2.0 / 2. 2.0 / 2. 2.0 / 2..1.1 /.9 / / / LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB Thermal-magnetic Electronic Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Equipped WSS, PSS & SUPER SERIES 15

SPECIFICATIS Specifications of Moulded-Case Circuit Breakers 400 0 A Type (Reference for Order information on p. 2) NF400-CEP (20) NF400-SEP (21) NF400-HEP (22) NF400-REP (2) Frame (A) 400 400 400 400 Rated data Mechanical data External accessories Rated current I n [A] at ambient temperature 40 C 200 400 200 400 200 400 Number of poles / 4 / 4 Rated insulation voltage U i [V] 00 90 90 90 Rated breaking capacity [ka] IEC/EN 094-2 (50/0 Hz) 200 400 90 V 10 / 10 (5 / 5) 10 / 10 15 / 10 500 V 15 / 0 / 0 (25 / 25) 50 / 50 0 / 5 440 V 25 / 1 42 / 42 ( / ) 5 / 5 5 / (I cu / I cs ) 400 V / 1 45 / 45 ( / ) 0 / 0 5 / 20 V 50 / 20 5 / 5 (5 / 5) 100 / 100 150 / 5 Utilization category B B B B Rated short-time withstand current I cw [ka/s] 5 / 0.25 5 / 0.25 5 / 0.25 5 / 0.25 Rated impulse withstand voltage U imp [kv] Pollution degree Reverse connection Suitable for isolation a 140 140 / 15 140 / 15 140 ca a c b 25 25 25 25 Dimensions [mm] b c 10 10 10 10 ca 155 155 155 155 Weight [kg].0.0 /..0 /..0 Cassettetype accessories Accessories connection Installation and connection Built-in accessories External operating handle Electrical operation device Handle lock device Terminal cover Alarm switch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) with terminal block (SLT) with internal terminal type Front Busbar terminal (standard) Rear (B) Plug-in Rear (PM) Pre-alarm-contact output (PAL) Trip indicator (TI) Door mounting (V) Mounted on breaker (R) Spring-charge type (MDS) Handle lock for use with padlock (HL) (HL-S) Large (TC-L) For rear connection (BTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Marine approval for pole breakers LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, AB Automatic tripping device Electronic Electronic Electronic Electronic Trip button Equipped Equipped Equipped Equipped DC type on request. In case of solderness terminal, interrupting capacity reduces. On request. Others on request. Missing specifications accord. to IEC/EN 094-2 on request. Others 1 WSS, PSS & SUPER SERIES

SPECIFICATIS NF400-UEP (24) NF0-CEP (25) NF0-SEP (2) NF0-HEP (2) NF0-REP (2) NF0-UEP (29) 400 0 0 0 0 0 200 400 00 0 00 0 00 0 00 0 00 0 /4 /4 /4 /4 90 00 90 90 90 90 5 / 5 10 / 10 15 / 15 20 / 15 5 / 5 10 / 10 1 / 9 0 / 0 50 / 50 0 / 5 10 / 10 200 / 200 / 1 42 / 42 5 / 5 5 / 200 / 200 200 / 200 / 1 45 / 45 0 / 0 5 / 200 / 200 200 / 200 50 / 25 5 / 5 100 / 100 150 / 5 200 / 200 B B B B B B 5 / 0.25. / 0.25. / 0.25. / 0.25. / 0.25. / 0.25 140 / 2 210 210 / 2 210 / 2 210 210 / 2 29 / 22 25 25 25 25 22 200 10 10 10 10 200 252 155 155 155 155 252 1. / 2.1 10.5 10.5 / 1. 10.5 / 1. 10.5 25. / 1.9 / / LR, GL, BV, NK, AB LR, GL, BV, DNV, AB LR, GL, BV, NK, AB LR, GL, BV, NK, AB LR, GL, BV, AB LR, GL, BV, AB Electronic Electronic Electronic Electronic Electronic Electronic Equipped Equipped Equipped Equipped Equipped Equipped WSS, PSS & SUPER SERIES 1

SPECIFICATIS Specifications of Moulded-Case Circuit Breakers 0 100 A Type (Reference for Order information on p. 2) NF0-CEP (0) NF0-SEP (1) NF0-HEP (2) NF0-REP () Frame (A) 0 0 0 0 Rated data Mechanical data Rated current I n [A] at ambient temperature 40 C 400 0 400 0 400 0 Number of poles / 4 / 4 Rated insulation voltage U i [V] 00 90 90 90 Rated breaking capacity [ka] IEC/EN 094-2 (50/0 Hz) 400 0 90 V 10 / 10 15 / 15 20 / 15 500 V 1 / 9 0 / 0 50 / 50 0 / 5 440 V / 1 42 / 42 5 / 5 5 / (I cu / I cs ) 400 V / 1 45 / 45 0 / 0 5 / 20 V 50 / 25 5 / 5 100 / 100 150 / 5 Utilization category B B B B Rated short-time withstand current I cw [ka/s] 9. / 0.25 9. / 0.25 9. / 0.25 9. / 0.25 Rated impulse withstand voltage U imp [kv] Pollution degree Reverse connection Suitable for isolation a 210 210 / 2 210 / 2 210 ca a c b 25 25 25 25 Dimensions [mm] b c 10 10 10 10 ca 155 155 155 155 Weight [kg] 10.9 10.9 / 14.2 10.9 / 14.2 10.9 Cassettetype accessories Accessories connection Installation and connection Alarm switch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) with terminal block (SLT) with internal terminal type Front Busbar terminal (Standard) Rear (B) Plug-in Rear (PM) External accessories Built-in accessories External operating handle Electrical operation device Handle lock device Terminal cover Pre-alarm-contact output (PAL) Trip indicator (TI) Door mounting (V) Mounted on breaker (R) Spring-charge type (MDS) Handle lock for use with padlock (HL) (HL-S) Large (TC-L) For rear connection (BTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Marine approval for pole breakers LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, AB LR, GL, BV, AB Automatic tripping device Electronic Electronic Electronic Electronic Trip button Equipped Equipped Equipped Equipped DC type on request. On request. Others on request. Assembly by factory. TC-N. Missing Specifications accord. to IEC/EN 094-2 on request. Others 1 WSS, PSS & SUPER SERIES

SPECIFICATIS NF0-UEP (4) NF1000-SS (4) NF50-SS (5) NF50-UR () NF100-SS () 0 1000 50 50 100 400 0 500 1000 00 50 00 00 0 1000 00 50 0 100 /4 /4 /4 /4 /4 90 90 90 90 90 5 / 5 25 / 1 25 / 1 25 / 1 10 / 10 5 / 5 / 5 / 42 5 / 200 / 200 5 / 4 5 / 4 5 / 5 5 / 4 200 / 200 5 / 4 5 / 4 5 / 5 5 / 4 200 / 200 5 / 5 / 10 / 5 5 / B B B B B 9. / 0.25 20 / 0. 20 / 0. 20 / 0. 210 / 2 210 / 2 210 / 2 240 / 10 210 / 2 22 40 40 40 40 200 140 140 144 140 252 190 190 194 190 2. /. 2.5 / 0. 2.5 / 0..2 / 4. 4.5 / 41.2 / LR, GL, AB LR, GL, AB Electronic Electronic Electronic Electronic Electronic Equipped Equipped Equipped Equipped Equipped WSS, PSS & SUPER SERIES 19

SPECIFICATIS Specifications of Disconnectors DSN, IEC 094-, EN 094- Type (Reference for Order information on p. 2) DSN2-SW () DSN-SW (9) DSN5-SGW (40) DSN10-SGW (41) DSN250-SGW (42) Rated data Mechanical data External accessories Rated current I n [A] 40 C 2 5 10 250 Numberofpoles /4 /4 /4 /4 Rated insulation voltage U i [V] 00 00 00 90 90 DC 250 250 250 250 250 Rated voltage U e [V] 500 00 90 90 90 DC 250 250 00 00 00 Rated impulse withstand voltage U imp [kv] kv Pollutiondegree 2 2 2 2 2 Utilization category -2A, DC-2A -2A, DC-2A -2A, DC-2A -2A, DC-2A -2A, DC-2A Making and braking current Making current / DC A 20 / 0 / 252 50 / 500 100 / 40 2500 / 1000 cycles 5 5 / 5 / 5 / 5 / DC A 25 / 504 / 252 1000 / 500 / 40 2000 / 1000 cycles 5 5 / 5 / 5 / 5 Operational Without current 10000 10000 50000 40000 25000 performance With current (440 V / 90 V) 000 / 000 / 0000 / 1000 20000 / 1000 10000 / 1000 Short-time withstand current I cw 1 s A 1000 1000 2000 000 4000 Short-circuit making capacity I cm 1 s A 1500 1500 000 4000 000 / DC A 192 / / 15.5 50 /.5 90 / 400 1500 / 25 Max. switching current cycles Suitable for isolation ca a 5 5 / 100 5 / 100 90 / 0 105 / 140 a c b 10 10 15 15 15 Dimensions [mm] b c ca 90 90 110 110 110 Weight [kg] 0.55 0.0 2.0 / 2. 2.0 / 2. 2.0 / 2. Breaking current Cassettetype accessories Accessories connection Installation and connection External operating handle Alarm switch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) with terminal block (SLT) with internal terminal type Front Busbar terminal Solderless terminal Busbar terminal Rear (B) Plug-in Rear (PM) Rear front IP 20 with auto trip (PM-IP) Door mounting (V) Mounted on breaker (R) Electrical operation device (MDS) Handle lock device Handle lock for use (HL) with padlock (HL-S) Lock cover (LC) Large (TC-L) Terminal cover Small (TC-S) / / For rear connection (BTC) / / Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 5 mm rail Corresponding type of circuit breaker NF2-SW NF-SW NF5-SGW NF10-SGW NF250-SGW This performance is accordance with IEC094-2 clause.2.4.1. On request. Standard. Assembly by factory. TC-N. Missing specifications accord. to IEC/EN 094-2 on request. 20 WSS, PSS & SUPER SERIES

SPECIFICATIS DSN400-SP (4) DSN0-SP (44) DSN0-SP (45) DSN1000-SS (4) DSN50-SS (4) DSN100-SS (4) 400 0 0 1000 50 100 /4 /4 /4 /4 /4 /4 90 90 90 90 90 90 250 250 250 250 250 250 90 90 90 90 90 90 250 250 250 250 250 250-2A, DC-2A -2A, DC-2A -2A, DC-2A -2A, DC-2A -2A, DC-2A -2A, DC-2A 4000 / 100 00 / 2520 00 / 200 10000 / 4000 500 / 5000 1000 / 400 /5 /5 /5 /5 /5 /5 200 / 100 5040 / 2520 400 / 200 00 / 4000 10000 / 5000 0 / 400 /5 /5 /5 /5 /5 /5 4000 4000 2500 2500 2500 2500 1000 1000 500 500 500 500 000 00 10000 000 000 1000 10200 100 1000 24000 24000 2000 2400 / 1000 / 155 40 / 2000 000 / 2500 500 / 5 900 / 4000 140 / 15 210 / 2 210 / 2 210 / 2 210 / 2 210 / 2 25 25 25 40 40 40 10 10 10 140 140 140 155 155 155 190 190 190 5. /.5.5 /.5 10.9 / 14.2 2.0 / 0.2 2.0 / 0.2 4.0 / 40. NF400-SEP NF0-SEP NF0-SEP NF1000-SS NF50-SS NF100-SS WSS, PSS & SUPER SERIES 21

ORDER INFORMATI Order Information for Moulded-Case Circuit Breakers 5 A Ref. Type Rated current (In) Art. no. pole type S series with hydraulic-magnetic tripping device, fixed, 1 NF2-SW A 1409 4A 1410 A 1411 10 A 14 1 A 141 20 A 1414 25 A 1415 2 A 141 Art. no. 4 pole type 2 NF-SW A 141 141 4A 141 142 A 1419 14 10 A 1420 145 1 A 1421 14 20 A 1422 149 25 A 1424 1440 2 A 142 1441 40 A 142 1442 50 A 142 144 A 1429 1444 H series with hydraulic-magnetic tripping device, fixed, NF-HW 10 A 1445 1454 1 A 144 1455 20 A 144 145 25 A 144 145 2 A 1945 145 40 A 1450 1459 50 A 1452 140 A 145 141 Ref. Type Rated current (In) Art. no. pole type S series with thermal-magnetic tripping device,, DC Art. no. 4poletype 4 NF5-SGW RT 1 25 A 192 19 25 40 A 19 19 40 A 194 199 100 A 195 19 5 A 19 192 S series with electronic tripping device, adjustable, 5 NF5-SGW RE 1 2 A 194 195 2 A 149 19 100 A 149 1500 5 5 A 149 1502 H series with thermal-magnetic tripping device, adjustable,, DC NF5-HGW RT 1 25 A 1992 199 H series with electronic tripping device, 25 40 A 1994 1999 40 A 1995 1900 100 A 199 1901 5 A 199 1902 NF5-HGW RE 1 2A 190 1909 2 A 1904 1910 100A 1905 1911 5 5A 190 19 R series with thermal-magnetic tripping device, adjustable, NF5-RGW RT 1 25 A 190 25 40 A 190 40 A 1921 100 A 1922 U series with thermal-magnetic tripping device, adjustable, 9 NF5-UGW RT 1 25 A 192 192 25 40 A 1924 192 40 A 1925 1929 100 A 192 190 Reference to breaker specifications on p. ff. 22 WSS, PSS & SUPER SERIES

ORDER INFORMATI Order Information for Moulded-Case Circuit Breakers 10 250 A Ref. Type Rated current (In) Art. no. pole type S series with thermal-magnetic tripping device,, DC Art. no. 4 pole type 10 NF10-SGW RT 5 10 A 191 1914 S series with electronic tripping device, 11 NF10-SGW RE 10 A 1915 191 H series with thermal-magnetic tripping device,, DC NF10-HGW RT 5 10A 191 191 H series with electronic tripping device, adjustable, 1 NF10-HGW RE 10 A 1919 1920 S series with thermal-magnetic tripping device, adjustable,, DC 14 NF250-SGW RT 5 10 A 191 19 10 250 A 19 19 Ref. Type Rated current (In) Art. no. pole type Art. no. 4poletype H series with thermal-magnetic tripping device, adjustable,, DC 1 NF250-HGW RT 5 10 A 199 1991 10 250 A 1990 199 H series with electronic tripping device, adjustable, 1 NF250-HGW RE 5 250 A 150 150 R series with thermal-magnetic tripping device, adjustable, 1 NF250-RGW RT 5 10 A 191 10 225 A 192 U series with thermal-magnetic tripping device, adjustable, 19 NF250-UGW RT 5 10 A 19 195 10 225 A 194 19 S series with electronic tripping device, adjustable, 15 NF250-SGW RE 5 250 A 150 1505 Order Information for Moulded-Case Circuit Breakers 400 0 A Ref. Type Rated current (In) Art. no. pole type C series with electronic tripping device, adjustable, 20 NF400-CEP 200 400 A 19945 25 NF0-CEP 00 0 A 1995 0 NF0-CEP 400 0 A 1991 S series with electronic tripping device, adjustable, Art. no. 4 pole type 21 NF400-SEP 200 400 A 19949 19950 2 NF0-SEP 00 0 A 1995 1995 1 NF0-SEP 400 0 A 1995 199 Ref. Type Rated current (In) Art. no. pole type R series with electronic tripping device, adjustable, 2 NF400-REP 200 400 A 1994 2 NF0-REP 00 0 A 1995 NF0-REP 400 0 A 1994 U series with electronic tripping device, adjustable, Art. no. 4poletype 24 NF400-UEP 200 400 A 19951 19952 29 NF0-UEP 00 0 A 19959 1990 4 NF0-UEP 400 0 A 199 199 H series with electronic tripping device, adjustable, 22 NF400-HEP 200 400 A 1994 1994 2 NF0-HEP 00 0 A 19954 19955 2 NF0-HEP 400 0 A 1992 199 Order Information for Moulded-Case Circuit Breakers 1000 100 A Ref. Type Rated current (In) Reference to breaker specifications on p. 14ff. Art. no. pole type SS/UR series with electronic tripping device, adjustable, Art. no. 4 pole type 5 NF1000-SS 500 1000 A 14144 14145 NF50-SS 00 50 A 141454 14141 NF50-UR 00-00-0-1000- 00-50 A 1414 14140 NF100-SS 0 100 A 14145 14142 Order Information for Disconnectors DSN series 2 100 A Ref. Type Rated current (In) Disconnectors (no tripping device) Art. no. pole type 9 DSN2-SW 2 A 140 Art. no. 4poletype 40 DSN-SW A 19 19 41 DSN5-SGW 5 A 199 1940 42 DSN10-SGW 10 A 1941 1942 4 DSN250-SGW 250 A 194 1944 44 DSN400-SP 400 A 19929 1990 45 DSN0-SP 0 A 1991 19942 4 DSN0-SP 0 A 1994 19944 4 DSN1000-SS 1000 A 14141 14144 4 DSN50-SS 50 A 14142 1414 49 DSN100-SS 100 A 1414 1414 WSS, PSS & SUPER SERIES 2

POLE Ui90V Cat.A P Uimp kv PUSH TO TRIP 0 2.5 100 100 2 4 5.5 T Ip IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V 00V EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA 20/20kA 0% PAL Is TL Ii Ts Ii(X100A) 10.1.2 10.0. 4 14.0.10 Ir OVER 0 2.5 100 100 2 4 5.5 T Ip 0% Is TL Ii Ts Ii(X100A) 10.1.2 10.0. 4 14.0.10 Ir PAL OVER 4 5 0.5 0 2.5 100 100 2 4 5.5 T Ip 0% PAL Is TL Ii Ts Ii(X100A) 10.1.2 10.0. 4 14.0.10 Ir OVER 0 2.5 100 100 2 4 5.5 T Ip 100-240V Install and uninstall the accessory in tripped position, not in or position SHTA240-2GSWRS 0% PAL Is TL Ii Ts Ii(X100A) 10.1.2 10.0. 4 14.0.10 Ir OVER b 14 a POLE Ui90V Cat.A P Uimp kv PUSH TO TRIP 0 2.5 100 100 2 4 5.5 T Ip IEC094-2 JIS C 201-2 Ue 90V 525V 500V 440V /415V 20V 00V EN094-2 40 C Icu/Ics /ka 22/22kA 0/0kA /ka /ka 5/5kA 20/20kA 0% PAL Is TL Ii Ts Ii(X100A) 10.1.2 10.0. 4 14.0.10 Ir OVER MITSUBISHI NO-FUSE BREAKER NF5-SGW 100 In A Ir -100A AUXILIARY SWITCH 5V 250V 5V 0.4A 250V 0.2A AXc AXb AXa 11c AX AUXILIARY SWITCH 5V 250V 5V 0.4A 250V 0.2A AXc AXb AXa 11c AX b 14 a DC DC DC DC 5A A 5A A 11 11 14 b 14 14 a MITSUBISHI NO-FUSE BREAKER NF5-SGW 100 In A Ir -100A RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) AUXILIARY SWITCH AXc 5V 250V 5V AXb AXa 11c AX DC DC 250V 5A A 0.4A 0.2A 11 14 95 c T Ir Ip Is Ts Ii(X100A) 10.1.2. 4 14 INTERNAL CESSORIES Internal Accessories Modular cassette type accessories The new arrangement and design of pluggable accessories such as indicator and auxiliary contacts allows you to modify the circuit in a way that saves time and space at any time, even when built in and ready for operation. Alarm switch (AL) Provides for indication that the MCCB has tripped. The presence of separate circuit chambers makes the system even safer. Thus cassette type accessories ensure flexibility when upgrading circuits. Auxilliary switch (AX) Provides for indication of whether the breaker is or. The cassette type accessories are available in several versions and fit for breaker series from 2 A up to 0 A: alarm switch (AL) auxiliary switch (AX) alarm and auxiliary switch (AL+AX) shunt trip device (SHT) undervoltage trip device (UVT) with lead-wire terminal block as standard. In addition you can choose the lead-wire version or the internal terminal type as an option. Shunt trip (SHT) Lead-wire terminal block (SLT) The terminal block is used for bringing out the connections of the internal accessories. The cassette type accessories are also available as internal terminal type without terminal block. The connection cables are lead out of the breaker housing in line-side direction. Soitispossibleto mount several breakers easy side-by-side in a row. ALARM SWITCH 9 ALc 9 ALb 9 ALa 5V 5A 250V A DC 5V 0.4A DC 250V 0.2A 14 AXa AXb AUXILIARY SWITCH 11 AXc 5V 5A 250V A DC 5V 0.4A DC 250V 0.2A 11 14 9 9 c b a a b AX AL ALAX-2GSWLS Lead-wire terminal block Example: ALAX 2.5 100 100 2 RE100 In 100A TL Ii 0% Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) PAL 10.0.0.10 OVER 100-240V Install and uninstall the accessory in tripped position, not in or position Provides for tripping from a remote location. The control voltage range is 0 100 % of rated voltage. The shunt trip enables an MCCB to be used in combination with an ELR. SHTA240-2GSWRS Internal terminal type Example: SHT Undervoltage trip (UVT) The tripping voltage is 5 0 % of the rated voltage. When the voltage recovers to at least 5 %, the breaker can be manually closed or reset. Provides for electrical interlock, and is used where electrical machines need to be protected against voltage drop. Simple Installation ALAX-2GSWLS RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) RE100 In 100A Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr) Push trip button! How to install: 1. Push the trip button (PTT) to trip the breaker and loosen the front cover screws. 2. Open the front cover.. Install the cassette(s). 4. Close the front cover and tighten the screws. 5. Check the correct function. Caution! Always ensure the breaker is tripped when installing accessories. Please entrust installation to an experienced person. Please refer to the instruction manual in the box. For the breakers of the Super Series, 1000 A up to 100 A, please contact your Distributor. 24 WSS, PSS & SUPER SERIES

INTERNAL CESSORIES Overview of Internal Accessories Cassette-type internal accessory Function Catalogue reference AL (Alarm switch) The alarm switch AL indicates that the breaker has tripped. page 2 AX (Auxiliary switch) The auxiliary switch AX indicates whether the breaker is or. page 2 SHT (Shunt trip) UVT (Undervoltage trip) The shunt trip SHT trips the breaker automatically by remote. A cut-off switch is integrated. The allowable tripping voltage is 0% to 110% of the rated voltage for both and DC. The undervoltage trip UVT trips the breaker automatically when the voltage drops. The tripping voltage is 5% to 0% of the rated voltage. When the voltage recovers to 5% of the rated voltage or above, the UVT can be reset and the breaker closed. page 2 page 0 Connection of the Control Wires For the connection of the control wires offers you two ways: Lead-wire terminal block (SLT) Internal terminal type for direct connection. Lead-Wire Terminal Block (SLT) Lead-wire terminal block SLT with screw terminals ALARM SWITCH 9 ALc 9 ALb 9 ALa 5V 5A 250V A DC 5V 0.4A DC 250V 0.2A 14 AXa AXb AUXILIARY SWITCH 11 AXc 5V 5A 250V A 5V 0.4A 250V 0.2A 95 c 14 a 9 b b 9 a 11 c AX AL ALAX-2GSWLS Application All cassette-type accessories are standardly equipped with the Lead-wire terminal block SLT. The terminal cover for the lead-wire terminals is available for the safety of live parts. It is available for front connection type, rear connection type and plug-in type. Correspondent terminals are not necessary. Uneven arrangement of terminal srews is adopted for easier wiring. Tightening check of a terminal srew is easy. Terminal cover of a terminal block is standard equipment (co-packed). DC DC Cassette-type accessory Example: ALAX, also for SHT, UVT Internal Terminal Type for Direct Connection Application Screw terminals AL-2GSWN 9 9 ALa ALb Example: AL, also for SHT, UVT Optional the cassette-type accessories are available as internal terminal type without terminal block. The control wires can be connected to the integrated screw terminals and can be lead out of the breaker housing in line-side direction. Quick install and de-install of the internal accessories is possible without demounting the breaker. Mounting of several breakers side-by-side in a row is possible. Thus the screw terminals for control wires are inside of the breaker housing, no special terminal cover for the screw terminals is nessesary. WSS, PSS & SUPER SERIES 25

INTERNAL CESSORIES Alarm Switch and Auxiliary Switch (Mounted on left side) Application The alarm switch AL indicates that the breaker has tripped. The auxiliary switch AX indicates whether the breaker is or. The alarm and auxiliary switch ALAX is a combination of the alarm switch AL and the auxiliary switch AX in one housing. AUXILIARY SWITCH 11 14 AXc AXb AXa 5V 5A 250V A 5V 0.4A 250V 0.2A 11 14 c b a AX AL, AX and ALAX standard types are for left-side mounting and equipped with lead-wire terminal block SLT. Internal terminal type is also available. Please specify, if right-side mounted type or type with flying leads is needed. DC DC RE100 In 10 Ir(A) TL(S) IS(xIr) 50/ 4 5 0.5 2.5 100 100 2 10. RE100 In 100 Ir(A) TL(S) IS(xIr) 50/0 4 5 0.5 2.5 100 100 2 10.0 Contact plans 9 9 14 95 11 Figure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type. (1 W) (1 W) Alarm switch AL Auxiliary switch AX Switching Operation Alarm switch (AL) operation Main MCCB conditions Alarm contacts or ALa 9 (open) ALc 95 (DC+) ALb 9 (closed) Trip ALa 9 (closed) ALc 95 (DC+) ALb 9 (open) Auxilliary switch (AX) operation Main MCCB conditions Auxilliary contacts or Trip AXa 14 (open) AXc 11 (DC+) AXb (closed) AXa 14 (closed) AXc 11 (DC+) AXb (open) When DC use, polarity must be considered. AL, AX switching capacities Type of Micro-switch for Voltage (V ) Resistive loads (A) Inductive load (A) Voltage (V DC) Resistive loads (A) Inductive load (A) 40 250 0.2 0.2 AL/AX/ALAX-05 250 2 5 0.4 0.4 5 5 0 4 40 5 2 250 0. 0. AL/AX/ALAX- 250 10 10 5 0. 0. 5 10 10 0 10 When DC use, polarity must be considered. 2 WSS, PSS & SUPER SERIES