Moulded Case Circuit Breaker

Similar documents
NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

cor Long Run Experience

CHINT. NM7 Moulded Case Circuit Breaker

01 Spectra Plus - Introduction

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

NDM1 Series MCB Edition

Industrial Protection Products Edition

Motor Protection Circuit Breakers

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

KM1 Series Moulded Case Circuit Breaker

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DRX 125 Circuit breaker (not adjustable)

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

DPX earth leakage DPX 3 -I earth leakage

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

- Moulded-case Circuit Breaker

Moulded Case Circuit Breakers

Manual Motor Starters. Meta-MEC

MS General Information Extended Product Type: MS

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Data Sheet Manual Motor Starters Ex9SN Series

Compact NR630. NR100F to NR630F

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

INTELLIGENT AIR CIRCUIT BREAKER

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

DRX 100 B/N/H Circuit breaker (not adjustable)

Technical Information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Series KTU7 UL489 Molded Case Circuit Breakers

MCCB Accessories to suit AF

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Selection Guide Motor Control Device Solutions

3 - Protection components Motor circuit-breakers

D509E. Manual Motor - Starters

Series KTU7 UL489 Molded Case Circuit Breakers

DPX 1600 Electronic release

DRX 250 B/N/H Circuit breaker (not adjustable)

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Magnetic only

Standard Interlock Safety Switches

DPX Electronic + earth leakage


Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

3VU13, 3VU16 Circuit-Breakers

Thermal Overload Relays

Protection components

The effective choice The benefits of a product with the highest quality standards

Cat N 3. OVERALL DIMENSIONS

DPX 630 Electronic release

and other modular devices for low voltage installation

DPX moulded case circuit breakers

Technical Data Accessories MCBs Ex9B.

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Miniature Circuit Breakers

MINIATURE CIRCUIT BREAKER

Molded case circuit breakers

UEW5 series intelligent air circuit breaker

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Solenoid Locking Safety Switches

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

EKM1-63S MCB Mini Circuit Breaker

QF(13) - Series Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers

Memshield - ACB Ratings & Specifications

NB1 Miniature Circuit Breaker

825-P Modular Protection System for motors Specification Guide

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

C60H-DC C curve. Catalogue numbers

World Super Series WSS The extensive breaker series from Mitsubishi Electric


System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Molded Case Circuit Breaker

QF(19) - Series Miniature Circuit Breakers

1489-M Circuit Breakers

Short form catalogue Motor protection and control Manual motor starters

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Thermal-Magnetic Circuit Breaker M1-...

Circuit Breakers Ex9M

COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

BREAKER. Molded Case Circuit Breaker/Earth Leakage Circuit Breaker

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

250V 24V, 30V, 48V, 100 / 110V, 125V, 200 / 220V DC. 11mA. 2,000V AC / 1min. ±4.5kV, 3 times for each pole (1.2 / 50μs)

DX³ 4-pole RCBO 6000 A/10 ka

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Meta Solution. Contactors and Overload relays

DMX 3 -I 2500 switch disconnectors

Low voltage moulded case circuit breaker EB2

(p. 47) (p. 155) (p. 155)

Transcription:

1 Body 2 Plugin bottom base 3 Residual current protecting module 4 Electrical operating module 5 External wiring board 6 Shunt tripe 7 Undervoltage trip 8 Auxiliary contact 9 Alarm contact 10 Rotatory handle Page 16

Application Integrated with international Hi-tech,Ev21 series moulded case circuit breaker is a new type of circuit breaker which designed by our company. lt's compact, modularized, with high breaking capacity, zero-arc, completely environment friendly. Ev21 circuit breaker mainly applies to distribution systems with 50/60Hz, rated voltage up to 690V, rated current 12.5~1600A, its purpose lays in power distributing & protecting system against malfunctions such as overload, short-circuit, undervoltage, etc. it can also work as an infrequent ON/OFF switch under systems working in normal condition. Ev21 circuit breaker equips with intelligent controller as well, which not only makes its current adjustable but also grants protection against overload(long delay), short-circuit(short delay), shortcircuit(instantaneous) & undervoltage. it'ii certainly improve the entire power system's reliability, continuity & security. Ev21 circuit breaker also obtains isolating function Ev21 circuit breaker complies to GB14048.2, IEC60947-2 standards, with CCC, CE, TSE certifi cate approved. Work & Install Circumstance 1. Altitude of the installation place shall not exceed 2000m. 2. Circumstance temperature shouldn't be higher than +40 (+45 for marine type) or lower than -5 average temperature of 24h shall not exceed +35.Relative atmosphere humidity shall not exceed 50% when circumstance temperature is at 40, relative humidity could be higher if temperature drops, the average humidity of the most humid month shall not exceed 90%, in the meantime, average temperature of this month shall not be lower than +25,condensation on product surface due to temperature changing should be taken into conside-ration as well. 3. Working circumstance of the product shall not contain any explosive, metal corrosive or conductivemedia. 4. Vertical inclination against the installation surface should not exceed 50. 5. Working area ought to be rainproof and doesn't contain too much amount of vaporin air. 6. Working area mustn't be shaky. 7. Install type: lil 8. Pollution class: 3 9. There are two basic install methods: vertical connecting & horizontal connecting. 10. There are two wiring methods: upper wiring & lower wiring. 11. Breaker can be defi ned as fi xed type circuit breaker & plugin circuit breaker. ModeI Code Ev 21 - Operating method(d) Application code(c) Trip type & accessory code(refer to Diagram 1) Phase(b) Rated short-circuit breaking capacity code(a) Structurallevel rated current ST for Intelligent trip, no code for thermalmagnet type(e) Design code Company code a. Rated short-circuit breaking capacity: D-Economic type, N-Standard type, H-High breaking capacity type b. Phase: 2-2P, 3-3P, 4-4P. c. Application code: no code for distribution type, "2" for motor protection type. d. Operating method: no code for manual(default handle) type, "P" for electrical operating type "Z" for rotatory handle type e. "L" for residual current protecting function. Page 17

Diagram 1 accessory code Accessory code Tripping unit Accessory name Aux.+Undervoltage+Alarm Undervoltage + Alarm Auxilary(2)+Alarm Auxilary+contacts(2 sets) Shunt+Aux.+Alarm Auxilary+Shunt Undervoltage +Alarm Undervoltage trip Auxilary+Alarm Auxilary+contact 1 set Shunt+Alarm Shunt+trip Alarm contact No accessory Instantaneous trip only (Electromagnet trip) Duplex trip (Thermalmagnet trip) 200 208 210 218 220 228 230 238 240 248 260 268 270 278 300 308 310 318 320 328 330 338 340 348 360 368 370 378 Intelligent trip 400 408 410 418 420 428 430 438 440 448 460 468 470 478 Technical Data Model Ev21-100 Ev21ST-100 Ev21-160 Ev21ST-160 Ev21-250 Phase 3P,4P 3P,4P 3P,4P Structural max rated current Inm (A) Rated current In (A) 12.5,16,20,25 32,40,50,63 80,100 100 160 250 40,100 16,20,25,32, 40,50,63,80 100,125,160 160 20,25,32,40,50 63,80,100,125,160, 180,200,225,250 Rated voltage Ue (V) AC400,AC690 AC400,AC690 AC400,AC690 Rated insulating voltage Ui (V) 690 690 690 Rated withstand voltage Uimp (kv) 6 6 6 Rated ultimate short-circuit breaking capacity lcu(ka) Model N: 35 Model H: 70 Model N: 35 Model H: 70 Model N: 35 Model H: 70 Rated working short-circuit breaking capacity lcs(ka) Model N:18 Model N:18 Model N:18 Application type A A A Tripping unit Thermalmagnet Intelligent Thermalmagnet Intelligent Thermalmagnet Residual current protection With residual current protection module Working Lifespan Operating method Mechanical 8500 8500 7000 Electrical 1500 1500 1000 Manual Yes Yes Yes Rotatory handle Yes Yes Yes Electrical operating Yes Yes Yes Fixed(front panel) Yes Yes Yes Install method Fixed(back panel) Yes Yes Yes Drawable(front panel) Yes Yes Yes Drawable(back panel) Yes Yes Yes Page 18

Following diagram on previous page Technical data Model Ev21-100 Ev21ST-100 Ev21-160 Ev21ST-160 Phase 3P,4P 3P,4P 3P,4P Structural max rated current Inm (A) 250 400 160 Rated current In (A) 250 400 630 800,1000,1250,1600 Rated voltage Ue (V) AC400,AC690 AC400,AC690 Rated insulating voltage Ui (V) 690 690 Rated withstand voltage Uimp (kv) 6 6 Rated ultimate short-circuit breaking capacity lcu(ka) Model N: 35 Model H: 70 Model N: 45 Model H: 85 Model N: 45 Model H: 85 65 Rated working short-circuit breaking capacity lcs(ka) Model N:18 Model N:22.5 Model N:22.5 48 Application type A A Tripping unit Intelligent Intelligent Intelligent Intelligent Residual current protection Working Lifespan Operating method Install method With residual current protection module Mechanical 7000 5000 5000 2500 Electrical 1000 1000 1000 500 Manual Yes Yes Yes Yes Rotatory handle Yes Yes Yes Yes Electrical operating Yes Yes Yes - Fixed(front panel) Yes Yes Yes Yes Fixed(back panel) Yes Yes Yes - Drawable(front panel) Yes Yes Yes - Drawable(back panel) Yes Yes Yes - Attention: a. Right now only Model N & Model H products are available, lcu & lcs represent breaking capacity at AC400V. b. Default product applies to fixed(front panel) install method & manual operating method, do state out in your order if different requirements are demanded, c. We supply breakers with residual current protection to 630A(max). Breaker's overload long delay & short-circuit instantaneous protection features refer to diagram below Serial No. Distribution system breaker Testing current(times) Tripping time Status Circumstance temperature 1 1.05In 1h non-tripping(ln 63A), 2h non-tripping(ln>63a) Initial 2 1.3In 1h tripping(ln 63A); 2h tripping (ln>63a) Following serial 1 ±40 ±2 3 10In 0.2s tripping Initial Any suitable temperature Serial No. Motor protection breaker Testing current(times) Tripping time Status Circumstance temperature 1 1.05In 2h non-tripping Initial 2 1.3In 2h tripping Following serial 1 3 1.5In 4min tripping under serial 1 current till breaker reach thermal balance ±40 ±2 4 7.2In 2~10s tripping Initial 5 1 In 0.2s tripping Initial Any suitable temperature Page 19

Shape & Dimension Ev21-100, 160, 250 shape & dimension Attentionl: when In >100A, fi xing screw size should be M8, When In looa, fi xing screw size should be M6. Page 20

Ev21L-1-100, 160, 250 shape & dimension Attentionl: when In >100A, fi xing screw size should be M8, When In 100A, fi xing screw size should be M6. Page 21

Ev21ST-400, 630 shape & dimension Page 22

Ev21L-400, 630 shape & dimension Page 23

Ev21ST-1600 shape & dimension Page 24