Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

Section 1 COYOTE Closure Series

Closure End Plates and Accessories

INSTALLATION INSTRUCTIONS

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

Section 3 FIBERLIGN Closure Series

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

3M Fiber Dome Closure FDC 10

Fiber optic splice closure

CS Fiber Optic Splice Case. Instruction

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

Section 1 COYOTE Closure Series

Section 1 COYOTE Closure Series

INSTALLATION INSTRUCTIONS

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

FOSC-400A4 INSTALLATION INSTRUCTION

FIBER CONNECTOR SAFETY WARNINGS

Fiber Splice Panel Rack Mount User Manual

3000SC Fiber Optic Splice Closure

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

Environmental Distribution Center (EDC-06P-NH)

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Section 1 COYOTE Closure Series

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

Opti-Guard Splice Enclosure

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Instructions for Use - Opt-X 1000i Enclosure

SUT-450-I ASSEMBLY REQUIREMENTS

OPTICAL FIBER CLOSURE

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

YOURx-Aerial Terminal Installation Manual

FARM MODEL INSTALLATION INSTRUCTIONS

Installation Instructions PowerBoard Automatic Retracting Running Board

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Installation Instructions PowerBoard Automatic Retracting Running Board

FOSC-100 B/H FOSC-100 B2/H

Section 10 ARMADILLO Stainless Series

INSTALLATION GUIDE. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

SPORTSTER SADDLEBAG KIT. i i02212

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Installation Instructions

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

K9-C23 INSTALLATION INSTRUCTIONS K9 Kit for CHEVY TAHOE PPV (9C1)

INSTALLATION INSTRUCTIONS

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

8400 Series Fiber Distribution System

Illustrated Parts & Packing List 815 Rice Lake Street, Owatonna, MN For a complete distributor & dealer list go to

Ford Super Duty SuperCab A Ford Super Duty SuperCrew A

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Stowe Cargo Management System

12-Inch Hybrid Fiber Access Terminal Installation Instructions

ASSEMBLY INSTRUCTIONS FOR CHARGER AND THE BOSS QUICK ATTACH GRASS BAGGER

INSTALLATION GUIDE. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

Installation Guide. Stowe Cargo Management System. Table of Contents

SUT-250-S (These instructions are used for SUT-250-SCLC also)

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

Section 10 ARMADILLO Stainless Series

USER'S MANUAL and INSTALLATION GUIDE

Fiber Connector Shelf (CCS)

INSTALLATION GUIDE Bolt-On Drag-Race Strut Clip Chevy II

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Installation Instructions: Side Delivery Units BDS-2555

LIGHT DUTY ROLL UP DOOR

FL2000 Termination/Splice Panels User Manual

Installation Instructions

INSTALLATION INSTRUCTIONS

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Polymer Insulators A Better Solution

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

FOG LAMPS INSTALL KIT

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Installation Instructions PowerBoard Automatic Retracting Running Board

Part Number: TTU-BGB14-DRL TTU-BGP14-DRL

Transcription:

OCTOBER 2017 COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 3 4 5 1 2 6 7 8 9 10 11 12 13 14 15 NOMENCLATURE 1. End Plate with HD Transition Tray Organizer (1) 2. Dome Cover (1) 3. Dome Gasket (1) 4. Dome Collar (1) 5. HD Closure Small Parts Bag (1) 6. 1 Hole Grommet Kit (0 or 1) (.60".85" Cable Range) 7. 1 Hole Grommet Kit (0 or 1) (.85" 1.0" Cable Range) 8. 1 Hole Grommet Kit (0 or 2) (1.0'' 1.25'' Cable Range) 9. 1 Hole Grommet Kit (0 or 2) (1.25'' 1.38'' Cable Range) 10. Small Parts Bag (1) 11. Transition Tube Kit (1) 12. Transport Tube Kit (1) 13. Spiral Wrap Tube Kit (1) 14. Ribbon Splice Tray - Deep (Order Separately) 15. Single Fusion Splice Tray - Thin (Order Separately) TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket wrench Side Cutters Snips Fiber optic cable opening tools COYOTE Splice Tray Capacity Chart for COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications PLP Catalog Number Description Image Splice Type Max Trays per Closure Closure Splice Capacity 80813121 Long Deep Profile Ribbon Flip Tray (288ct) Mass Fusion/Ribbon 4 1,152 80813123 Long Thin Profile Single Fusion Flip Tray (72ct) Single Fusion (Double Stack) 8 576 2017 Preformed Line Products Company. All rights reserved. 1

PLP Catalog Number Description COYOTE Dome Closure 9.5" x 28" Kits for High Density Splice Applications 80061406 COYOTE Dome Closure 9.5'' x 28'' without Transition Tray for cables under 1.25'' diameter. Includes (1) 1 Hole Grommet Kit - Cable Range.60''-.85'' & (1) 1 Hole Grommet Kit - Cable Range.85''-1.0'' 80061407 COYOTE Dome Closure 9.5'' x 28'' with Transition Tray for cables under 1.25 diameter. Includes (1) 1 Hole Grommet Kit - Cable Range.60''-.85'' & (1) 1 Hole Grommet Kit - Cable Range.85''-1.0'' 80061408 COYOTE Dome Closure 9.5'' x 28'' without Transition Tray for cables over 1.25'' diameter. Includes (2) 1 Hole Grommet Kit - Cable Range 1.0''-1.25'' & (2) 1 Hole Grommet Kit - Cable Range 1.25''-1.38'' 80061409 COYOTE Dome Closure 9.5" x 28" with Transition Tray for cables over 1.25" diameter. Includes (2) 1 Hole Grommet Kit - Cable Range 1.0"-1.25" & (2) 1 Hole Grommet Kit - Cable Range 1.25"-1.38" Accessory Kits for COYOTE Dome 9.5" x 28" Closures 80807991 100ft. Roll of.25" ID Tubing 80812618 Pack of (4) 18" Long Pieces of.25" ID Tubing 80807571 6ft. Long Piece of.375 O.D. Spiral Wrap Tubing 80805066-6 6ft. Long Piece of.625'' O.D. Spiral Wrap Tubing 80812881 100ft. Roll of.625'' O.D. Spiral Wrap Tubing 800015235 Replacement End Plate for the COYOTE Dome Closures 9.5" x 19" and 9.5" x 28" 80812608 Closure O-Ring Sealing Gasket for the COYOTE Dome Closures 9.5" x 19" and 9.5" x 28" 80808528-1 Latching Collar for the COYOTE Dome Closures 9.5" x 19" and 9.5" x 28" 800015236 Strength Member Bracket Kit Includes 3 Long L-Brackets and 3 Hose Clamps 80808651 Strength Member Bracket Kit Includes 4 Long L-Brackets 80809205 Strength Member Bracket Kit Includes 2 Short L-Brackets 80813124 Splice Tray Locking Pin Kit. Includes (6) tray locking pins 80813125 Splice Tray Tether Kit. Includes (6) Splice Tray Tether Straps 80811036 6 Position Bobbin Kit for Retaining Drop Cables COYEPFIX1 COYOTE Dome End Plate Fixture Mounting Brackets for COYOTE Dome 9.5" x 28" Closures 8004037 Aerial Adjustable Offset Mounting Bracket (Dome Mount) - Strand Applications 8004038 Aerial Adjustable Offset Mounting Bracket (Dome Mount) - ADSS Applications 8003942 Pole/Wall Mounting Bracket 8004003 Manhole Support COYOTE Grommet Chart for COYOTE Dome Closure 9.5" x 28" for High Density Splice Applications PLP Catalog Number Cable Range Inches (mm) Description Image Slitting Location 8003692.60" -.85" (15-22 mm) 1-entry grommet 8003693.85" - 1.0" (22-25 mm) 1-entry grommet 8003694 1.0" - 1.25" (25-32 mm) 1-entry grommet *8004145 1.25'' - 1.38'' (32-35 mm) 1-entry grommet 8003663.42" -.60" (11-15 mm) 2-entry grommet 8004065.250" -.312" (6-8 mm) 4-entry grommet 8003664.30" -.43" (8-11 mm) 4-entry grommet 8003677.125" -.25" (3-6 mm) 8-entry grommet N/A 2 *8004145 Grommet Kit can only be used in ports 3 and 6.

END PLATE PREPARATION CABLE PREPARATION Step #1 Determine which cable ports will be used and mark the respective breakout tabs of the end plate. Step #3 Measure the cable to determine the diameter and hole location to use in the grommet. 6 3 NOTE: For expressed buffer tube ribbon cables, use cable ports 3 and 6. Use all other cable ports for branch or drop cables if required Step #4 If using cut cable, insert the cable through the grommet. If your application requires express/balloon/ring cut cables, see Step 7 for the grommet slitting procedure. Step #2 Remove the end plate caps from the selected cable ports. Break out the outer and inner tabs of each cable port by snipping the grooves on both sides of each tab with side cutters. Once the grooves have been snipped, remove each tab by pulling the tab outwards from the end plate. Innerner Tab Outer Tab Step #5 Installing Figure 8 Style Cables and Cables with Tracer Wires Remove tracer wire or ground wire from the portion of the cable that will be positioned in the grommet and insert cable into the grommet. Cable with Tracer Wire Not Correct Installation Correct Installation Figure 8 Style Cable Not Correct Installation Correct Installation 3

Step #6 Grommet Slitting If slitting is required, lay the grommet on a stable flat surface. Position the utility knife with the cutting edge against the top surface and cut through the grommet. Consult the grommet chart on page 2 for slitting locations of all grommets. Step #8a Prepare buffer tube ribbon cable(s) for mid sheath applications (Express/Balloon/ Ring Cut). Buffer Tube Ribbon Cable Min. of 80" (2.0 m) OFFICE/C.O. A X PLP Tip: Use a pen to sketch slitting lines on top surface of grommet prior to cutting. Step #7 Slit Not Correct Slitting Angle Slit Correct Slitting Angle Prepare buffer tube ribbon cable(s) and unitube ribbon cable(s) for cut applications. NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 36 ribbons (432 fi bers). For Applications Where Fiber is Dedicated to the Splice Point Confi guration Unitube/Ribbon Expressed (Mid-Sheath) Cut Location Sheath Opening Min of 90" (2.29 m) PLP Tip: Leave about 8" (203 mm) of strength member to trim later. Step #8b Prepare buffer tube ribbon cable(s) for mid sheath applications (Express/Balloon/ Ring Cut). A Buffer Tube Ribbon Cable Min. of 90" (2.29 m) B X Min. of 160" (4.1 m) OFFICE/C.O. Minimum Sheath Opening for Cut Cable Applications 90" 2.29 m PLP Tip: Leave about 8" (203 mm) of strength member to trim later. NOTE: When expressing ribbons in the transition tray of the closure at this measurement, the maximum number of ribbons that can be expressed is 36 ribbons (432 fi bers). For Applications Where Fiber is NOT Dedicated to the Splice Point Confi guration Unitube/Ribbon Expressed (Mid-Sheath) Cut Location Sheath Opening Min of 160" (4.1 m) PLP Tip: Leave about 8" (203 mm) of strength member to trim later. B 4

Step #9 Align the sheath opening with the end of the slot of the strength member bracket as shown below and secure the cable to the bracket with the hose clamp provided. Step #11 Trim the large strength member 1/2'' (12.7 mm) past the end of the adapter. Secure the cable strength member to the adapter with the small hose clamp provided. Step #12 Secure the cable to the strength member bracket with the hose clamp provided. OPTIONAL - Securing Cable Strength Member to Strength Member Bracket Step #10 Assemble the adapter to the bracket as shown below. Step #13 Install a piece of spiral wrap tubing onto each buffer tube and slide it to the sheath opening of the cable. Spiral Wrap Tubing 5

Step #14 Mark each buffer tube 17'' (.43 m) away from the sheath opening and remove each buffer tube beyond the mark. Securing Cable Strength Member with Strength Member Bobbin (Only for use with Rollable/Spider Web Ribbon Cables) Step #16 Trim the strength member 6'' (152 mm) away from the sheath opening. 17" (.43 m) 6" (152 mm) Step #17 Install the bobbin on the end of the strength member as shown below. Bobbin Step #15 Slide each piece of spiral wrap tubing over the ribbon fibers of the buffer tubes. Secure the spiral wrap tubing to each buffer tube with a piece of electrical tape as shown below. Step #18 Bundle the buffer tubes tightly just past the end of the bobbin and wrap the tubes with electrical tape. Electrical Tape Electrical Tape End of Bobbin 6

Securing Branch/Drop Cable Strength Member(s) to Strength Member Bracket Step #22 Install the cap on the strength member bracket and loosely secure it to the bracket with the small nut provided. Step #19 Prepare central buffer tube(s) for unitube/ ribbon cable applications. Cable in Entry Ports 4 and 5 Cap 7" (178 mm) Small Nut Cable in Entry Ports 1, 2, and 7 2.25" (57 mm) Step #23 Position the strength members under the cap of the strength member bracket. Step #20 Align the sheath opening with the end of the slot of the strength member bracket as shown below. Strength Member Step #24 Tighten the nut of the cap to secure the strength members under the cap. Step #21 Trim the strength members flush with the end of the strength member bracket(s). Step #25 Secure the cable to the strength member bracket with the hose clamp. 7

Cable Installation and Routing Step #28 Position the slot of the strength member bracket leg over the stud and pull back the cable. Step #26 Lubricate the sealing surface of the grommet with the silicone lubricant that is provided. Step #27 Position the grommets in the end plate slots. IMPORTANT NOTE: Grommets with a cable range over 1.25 (32mm) can only be installed in cable ports 3 & 6. Step #29 Install the strength member bracket on the stud. Install the lock washer and nut against the bracket, but do not tighten fully, so that the bracket can slide as the grommet is compressed by the cable cap. Nut and lock washer wash DO NOT align the grommet slit with the end plate seam. End Plate Seam Grommet Slit Step #30 Install the cable caps and secure with hex bolts. NOTES: Tighten bolts by hand evenly until cable cap is fully seated (DO NOT USE POWER TOOLS TO TIGHTEN BOLTS). When using a can wrench or nut driver, the installed torque is 35 to 40 in-lbs. TIGHTEN ALL UNUSED CABLE CAPS. IMPORTANT: Tighten down the strength member bracket after the caps are tightened. 8

Step #31 Complete end plate assembly shown below. Step #33 Secure the buffer tube(s) in the side storage brackets with the retainer clips. To install the retainer clip, position the bottom slot of the retainer clip onto the bottom portion of the side storage bracket. Tilt the retainer clip forward until the top portion of the side storage bracket snaps into the top slot of the retainer clip. Retainer Clip Side Storage Bracket ROUTING BUFFER TUBE RIBBON CABLE Step #32 Route the buffer tubes through the side storage brackets. Side Storage Brackets ROUTING UNITUBE BRANCH/DROP RIBBON CABLE(S) Step #34 Route and secure the central tube of unitube cables to transition tray. Tie Wraps 9

Step #35 Use transition tube(s) to route ribbons from unitube cables installed in the upper cable port(s) to the transition tray. Secure the transition tube(s) to the transition tray with tie wraps. Step #38 Install the transition tray cover on the transition tray by snapping the tabs of the cover into the slots of the transition tray. Cover Transition Tube SPLICE TRAY INSTALLATION Tie Wraps Step #36 Route feeder ribbons within the transition tray. Step #39 Slide the hinge bracket of the splice tray into the slots of the spacer bracket until the hinge bracket is fully engaged into the spacer bracket. Hinge Bracket Spacer Bracket Step #37 Insert ribbons to be routed to the splice tray(s) into the transport tubes. Wrap a piece of felt around the ends of the transport tubes and secure the tubes to the transition tray with tie wraps. Tie Wraps Felt 10

ROUTING SPIRAL WRAP TUBING TO THE SPLICE TRAYS Step #40 Wrap the ends of each spiral wrap tube with a piece of felt and route the tubes to the splice trays. Secure the tubes to the splice trays with tie wraps. Step #42 Routing for Incoming Ribbons Route the fi rst 12 incoming and outgoing ribbons in each splice tray as shown below. Routing for Outgoing Ribbons IMPORTANT NOTE: If fi bers are being expressed, route the spiral wrap tubes that contain the expressed fi bers to the bottom splice tray. Use the remaining splice trays for storing spliced fibers. Splices 1-12 Splices 1-12 SPLICE TRAY MANAGEMENT Step #43 Splice the fi rst 12 incoming ribbons to fi rst 12 outgoing ribbons per your accepted company practices. Step #41 Route expressed fi bers in the bottom splice tray as shown below. Step #44 Install the platform into the splice tray by inserting the tab of the platform into the slot of the splice tray and then pushing the posts of the platform into the bosses of the splice tray Slot Tab Posts Boss 11

Step #45 Routing for Incoming Ribbons Route the last 12 incoming and outgoing ribbons in each splice tray as shown below Routing for Outgoing Ribbons Step #48 Install the lock pin into the hinge brackets as shown below. Step #49 Secure the splice tray(s) with the hold down strap. Hold Down Strap Splices 13-24 Splices 13-24 Step #46 Splice the last 12 incoming ribbons to last 12 outgoing ribbons per your accepted company practices. SECURING SPLICE TRAYS Step #47 Determine the number of splice trays that are installed in the organizer and locate the corresponding number on the lock pin. Trim the lock pin at the notched location just below the number. Notch Note: One side of the lock pin is numbered 1-12 for thin profile splice trays and the other side of the lock pin is numbered 1-6 for deep profile splice trays. 12

Step #50 To secure the splice trays while they are flipped up, attach the tethers from the button tabs of the tether bracket to the button tabs of the bottom splice tray that is flipped up. Button Tab Dome Preparation & Installation Step #52 Re-tighten all cable cap bolts (Step #30) to assure that the cable caps are fully seated. When using a can wrench or nut driver, the installed torque is 35 to 40 in-lbs. Tether Bracket Button Tab Step #53 Lubricate all surfaces around gasket with silicone lubricant to assure easy assembly and closure re-entry. Lubricate all inner surfaces of the gasket. Button Tabs on Side of Splice Tray Lubricate all outer surfaces of the gasket. Tethers Step #54 Make sure that the gasket is fully seated in groove of end plate. Slide the end plate gasket onto the end plate and press into the groove. Step #51 When the tethers are not being used they can be stored on the tether bracket by securing the loose ends of the tethers to the middle button tab as shown below. Step #55 Work the gasket into the groove. Middle Button Tab 13

Step #56 Position the dome over the end plate. Flash Test Procedure Step #59 Remove the cap from the air valve of the end plate. Step #57 Install the dome collar. Step #60 Pressurize closure up to a max of 10psi. Make sure that the lip of the dome is captured underneath the collar before securing the latch. Step #58 Fasten the latch and lock the collar by twisting the latch fastener clockwise 90 degrees. CAUTION: Do not fasten latch until collar is completely installed in the correct position or damage to latch may occur. Latch Fastener 14

Step #61 Spray all sealing surfaces of the dome end plate with a soap/water solution to determine if the end plate has been assembled properly. Step #63a Aerial Mounting Options For COYOTE 9.5" Dome Strand Mount Aerial Offset Bracket Kit (PLP Cat.#: 8004037) and 9.5" Dome ADSS Mount Aerial Offset Bracket Kit (PLP Cat.#: 8004038). Assemble each bug nut or ADSS clamp to each top aerial offset bracket as shown below. Strand Clamp Step #62 Release all pressure in the closure by pressing against the valve stem with the bump on the top of the air valve cap. ADSS Clamp Bump of Air Valve Cap Step #63b For Shorter Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Position 1 ADSS Clamp Shown Position 2 ADSS Clamp Shown 15

Step #63c For Taller Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Step #65 Attach a second hose clamp to each hose clamp with the mounting bracket on it and tighten each pair of hose clamps around the dome in the banding slots. Position 1 Strand Clamp Shown Step #66 Bracket installed on the dome closure. Step #64 Position 2 Strand Clamp Shown Insert hose clamp through the slots in each of the bottom aerial offset brackets. Strand Aerial Offset Bracket shown secured on a 9.5" Dome Slots 16

Step #67 Pole/Wall Mounting Option The COYOTE 9.5" Dome Pole/Wall Mount Bracket (PLP Cat.#: 8003942). Secure the gusset bracket to the hanger bracket with the bolts and nuts provided as shown below. Step #69 The COYOTE 9.5" Dome Pole/ Wall Mount Bracket (PLP Cat. #: 8003942). Install the pole/wall mount bracket assembly on to the grounding studs of the end plate of the closure and secure it to the end plate with the three nuts that are provided. Gusset Bracket Nuts Nut Step #68 Hanger Bracket The COYOTE 9.5" Dome Pole/ Wall Mount Bracket (PLP Cat. #: 8003942). Attach the hanger bracket to the pole mounting plate with the gusset side facing the same side as the bolt hole tabs of the pole mounting bracket. Step #70 Attach the dome pole mounting plate to a pole or a wall with either 5/8" through bolts, 1/4" lag screws, or banding. 1/4" Lag Screw Hole 5/8" Through Bolt Hole Banding Slots 5/8" Through Bolt Hole 1/4" Lag Screw Hole Bolt Hole Tabs Pole Mounting Bracket Banding Slots 1/4" Lag Screw Hole 5/8" Through Bolt Hole 1/4" Lag Screw Hole Banding Slots 17

SAFETY CONSIDERATIONS This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN PERSONAL INJURY OR DEATH. Do not modify this product under any circumstances. This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it. When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. For proper performance and personal safety, be sure to select the proper size PREFORMED product before application. PREFORMED products are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 www.preformed.com e-mail: inquiries@preformed.com SP3451 18