PCS compact soft starters

Similar documents
DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Electronic soft starters

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD


Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Size for Size Best Value in the Industry

RVS-DN Digital Reduced Voltage Motor Starter

Application Description

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Low and Medium Voltage Industrial Soft Starters

Air Circuit Breaker Retrofitting

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

Product Description. Application Description

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

RVS-AX Instruction Manual

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

AuCom - Soft Starters

MCD 200 Series Soft Starters

RVS-DX Digital Reduced Voltage Motor Starter

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Pocket Guide VLT Soft Starter the single speed drive

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Design Guide. VLT Soft Start Controller MCD 100

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

An Engineering Guide to. Soft Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Softstarter Intelligent Controllers

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Softstarters Type PSS. Softstarters. General information

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

a revolution in soft start motor control The future of soft start motor control at your fingertips

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Section 0.0 Warnings... 2 Section 1.0

The future of soft start motor control at your fingertips

Pocket Guide VLT Soft Starter the single speed drive

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

SECTION MOTOR CONTROL

a revolution in soft start motor control The future of soft start motor control at your fingertips

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Contents. MCD 200 Design Guide. Contents

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

CTi Automation - Phone: Fax: Web:

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

825-P Modular Protection System for motors Specification Guide

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Low cost, internally bypassed non optimizing soft starter

SDS Enclosed Star-Delta Starter User Guide

Dimensions WxHxD [mm] Weight [kg]

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Hp V AC Current Rating [A] 230V AC 60 Hz

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

For Operation in the Control Cabinet 3RW Soft Starters

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Part # Features & Applications Specifications Cross Reference

1.1 Caution Statements

ABB Softstarter Benefits Charnchanok Thongprad

Softstarters Softstarters

PSE The efficient range Description

SOLSTART Instruction Manual

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

Features and Benefits

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry.

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

USERS MANUAL MCD REMOTE OPERATOR

4491 en / c. D IGISTART et. Reference guide

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Reduced Voltage Motor Starters

HIB Enclosed Inverter User Guide

MAGNETIC MOTOR STARTERS

Panorama. Softstarters The complete range

Features and Benefits. Control Features

Application Engineering

Catalog. Softstarters Type PSR, PSS, PSE, PST and PSTB

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Submittal Data Information

Bulletin 825 SMM Smart Motor Manager

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Open Chassis Star-Delta Starter User Guide

Application Engineering

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

MaxPak Plus Analog DC V S Drive

Transcription:

PCS compact soft starters Soft starting solutions with integrated motor protection. MOTOR CONTROL AND DRIVES Myriad Pro Condensed 12 pt Capitals White NHP Electrical Engineering Products AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com

PCS Soft Starters The Compact Choice The PCS provides intelligence and consistent performance in a compact design for controlling your motor. PCS soft starters are suitable for motor starting applications up to 45 kw (3 wire) and 75 kw (6 wire) at 400/415V AC. It features microprocessor-controlled electronic overload with adjustable trip class, motor and system diagnostics, configurable auxiliary contacts, and selectable start and stop modes. All of these combined features provide a highly accurate, reliable, and efficient soft starter with one of the smallest footprints in the industry. The PCS Advantage Compact size with integral bypass From a slim 45 mm in width, the PCS integrates a bypass to minimise heat generation during run time. The bypass automatically closes when the motor reaches its nominal speed, resulting in a cooler-running component and reduction in enclosure size. True three phase control The PCS controls all three motor phases for smoother starting and minimal thermal stress on the motor. 3 wire / 6 wire motor connection With 3 wire and 6 wire motor connection compatibility as standard, the PCS offers you flexibility. When configured for 6 wire mode the PCS is able to control larger motors without any cost penalty to the user. Choice of starting & stopping modes PCS soft starters provide the user with a selection of starting and stopping modes as standard. The ability to select and tailor the starting mode ensures the full benefits of soft starting can be achieved in any industrial motor starting application. Side-by-side stacking at 40 ºC 1 ) The PCS can be stacked side-by-side thereby saving further panel space and reducing enclosure size. 24V AC/DC control variant The standard PCS has a wide control supply range of 100-240V AC for ease of installation. In addition, a 24V AC/DC control variant is available, maximising your control options. Notes: 1 ) The PCS can be stacked side-by-side with no space between units. However, frame size one models (1 37 A) require the optional add-on fan attachment (retains same compact footprint). Frame size two models (43...85 A) include fan as standard. 2

Control Mode Overview Control Mode Description Diagram Soft Start Output voltage is ramped from user-adjustable initial torque setting out to user selectable start time. Current Limit User-adjustable current limit start by maintaining a constant current to the motor. Kickstart User-selectable voltage boost at startup to break away loads, and then ramp continues in the mode selected. Coast to Stop Voltage is removed and the motor coasts to rest. Soft Stop Output voltage is ramped down from full voltage to zero voltage according to a user selectable ramp time. 3

Protection features Electronic motor overload protection with user selectable trip class The PCS soft starter provides electronic motor overload protection with adjustable trip class and automatic or manual reset selectivity as standard. Selecting a trip class that closely resembles the driven motor s thermal withstand capabilities, minimises nuisance tripping and maximises machine up-time and plant productivity. The motor full load current is user adjusted via a blue potentiometer located on the front panel. Overload trip class (either OFF, 10, 15 or 20) and automatic or manual reset operation are DIP switch selectable. Phase imbalance protection The phase imbalance on a PCS is a measure of the difference in current between the highest and lowest phases. If the percentage of difference is 65 % or greater, the PCS will fault on a phase imbalance. Shorted SCR Prior to every start, the PCS checks the integrity of its power assembly (SCRs). If the PCS detects a shorted SCR, the start will be aborted. Flash coded LED indication When a fault is detected the PCS will trip and illuminate a flash coded fault LED to protect the motor and assist in the troubleshooting process. Starter over-temperature protection The PCS monitors the temperature of its power circuits (SCRs) by means of internal thermistors. Phase sequence protection The PCS provides a user selectable (ON or OFF) phase sequence protection function as standard. When selected, the PCS will monitor the incoming phases before application of power to the motor. Phase loss protection The PCS provides phase loss protection to both the line and load sides as standard to ensure the motor will not attempt to start when there is a power phase missing. This protects the motor from burnout resulting from single phase starting conditions. Open circuit output (open load) protection The PCS monitors the motor circuit to ensure the motor is connected before it commences its ramp. This feature is aimed at those installations which may have a motor isolator fitted between the starter and the motor, thus preventing a start when the isolator is in the open position. LED Description (Number of Flashes) Solid RUN/ON x 1 Overload x 2 Starter over-temperature x 3 Phase reversal x 4 Phase loss/open load x 5 Phase imbalance x 6 Shorted SCR x 7 Test 4

Typical Applications for the PCS Soft starter ratings are strongly influenced by the starting time and starting current characteristics of the driven machine. NHP have classified the industrial applications listed below as normal duty, defined as 350% FLC for a 10 second start. Note this is intended as a guide only. Individual machine and motor characteristics will determine the actual start current and start time requirements. For technical assistance with soft starter selection, or PCS suitability for applications outside what is listed, consult NHP. Bottle washer Compressor Screw (Unloaded) Conveyor Roller Crusher Cone Crusher Rotary Crusher Vertical Impact Dust Collector Edger Fan Axial (Damped) Fan Centrifugal (Damped) Grinder Hydraulic Power Pack Planer Press Pump Bore Pump Centrifugal Saw Circular Slicer PCS Product Selection 3 wire motor connection, 200 to 480V AC Three-Phase Supply Normal duty Dimensions (mm) Catalogue. No. 1 ) 3.5x FLC, 10 sec W H D 100 240V AC control 24V AC/DC control 3 A 45 140 112 PCS-003-480V PCS-003-480V-024 9 A 45 140 112 PCS-009-480V PCS-009-480V-024 16 A 45 140 112 PCS-016-480V PCS-016-480V-024 19 A 2 ) 45 140 112 PCS-019-480V PCS-019-480V-024 25 A 45 140 112 PCS-025-480V PCS-025-480V-024 30 A 45 140 112 PCS-030-480V PCS-030-480V-024 37 A 2 ) 45 140 112 PCS-037-480V PCS-037-480V-024 43 A 72 206 132 PCS-043-480V PCS-043-480V-024 60 A 72 206 132 PCS-060-480V PCS-060-480V-024 85 A 72 206 132 PCS-085-480V PCS-085-480V-024 For 600V AC supply or ratings for 6 wire motor connection, consult NHP. 1 ) Current ratings at 40 C ambient. Models PCS-003 to PCS-037 rated at 6 starts/hour. Models PCS-043 to PCS-085 rated at 10 starts/hour 2 ) When used with optional fan PCV-064 5

Accessories Side-mounted auxiliary contacts 1 ) 1x N/O contact 1x N/C contact 2x N/O contacts 1x N/O and 1x N/C contact PCS-PA-10 PCS-PA-01 PCS-PA-20 PCS-PA11 Contactor connection modules Connects PCS-003 019 to CA7-9 23 Connects PCS-030 037 to CA7-30 37 PCS-23-CI23 PCS-23-CI37 Remote reset magnets 24 V AC coil CMR7-24VA 240 V AC coil CMR7-230VA 24 V DC coil CMR7-24VDC Cooling fans Field installable fan to suit PCS-003 37 Field installable replacement fan to suit PCS-045 85 PCV-064 PCV-147 Marking tags Marking tag covers (x 100) Transparent cover (x 100) Marking tag stickers (x 100) CA7-FMP CA7-FMC CA7-FMS Notes: 1 ) As standard, the PCS includes a configurable (normal or up-to-speed) normally open (N/O) auxiliary contact. 6

Specifications Category PCS - 3 wire operation PCS - 6 wire operation Motor rating at 415V AC 0.55 to 45 kw 0.55 to 75 kw Current rating 1 to 85 Amps 1.7 to 147 Amps 1 ) Motor connection 3 wire (line) 6 wire (inside delta) Utilisation category to AS/NZS 60947-4-2 AC 53b (internal bypass contactor) No. of controlled phases 3 Supply voltage range (3 phase) PCS-xxx-480-xxx V 200 to 480V AC Control voltage range (+10 % / -15 %) Supply frequency range Soft start modes Stop modes Selectable start times Selectable initial torque Selectable current limit Selectable kick start - 450 % FLC Selectable soft stop Protective functions Enclosure rating Ambient temperature Altitude Relative humidity PCS-xxx-xxx V 100 to 240V AC PCS-xxx-xxx V-024 24V AC/DC 50/60 Hz, 3 phase supply and control Soft Start Current limit Kickstart Soft stop Coast to stop 2, 5, 10, 15, 20, 25, or 30 s 15 %, 25 %, 35 % and 65 % of locked rotor torque 150 %, 250 %, 350 % and 450 % of full load current OFF, 0.5, 1.0, or 1.5 s OFF, 100 %, 200 %, or 300 % of the start time setting when configured Electronic motor overload with adjustable trip class (OFF, 10, 15 or 20) Starter over-temperature Phase sequence/reversal Phase loss Phase imbalance Shorted SCR Open load IP 2X 40 C, with de-rating to 50 C 2000 m 5...95 % (non condensing) Notes: 1 ) Refer NHP for ratings information. For complete PCS specification consult NHP. 7

AUSTRALIA NEW ZEALAND nhp.com.au nhp-nz.com SALES 1300 NHP NHP SALES 0800 NHP NHP sales@nhp.com.au sales@nhp-nz.com NHP Electrical Engineering Products For more in download offering ex catalogues A.B.N. 84 004 304 812 NHP104708_10/18 Copyright NHP 2018 For more information, scan to download the NHP ecatalogues App offering exclusive video content, catalogues and literature