Nuclear Qualified Temperature Switches

Similar documents
Big Hermet Pressure Switches

B Temperature Switches

Temperature Switches. General Instructions

534HS Pressure Transmitter

102 Differential Pressure Switch

103 Differential Pressure Switch

T21 Thermal Differential Switch

RF Point Level Control with Sensor Monitor

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

Ultrasonic Two-Wire Point Level Control

TK-6024, TK-6124, TK-8024, TK-8124

1451 Control Valve. General Instructions. Table of Contents

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

DigiTemp. Digital Thermometer

E4-WM5-Y530A00 MOUNTING INSTRUCTION

Electric Actuator Installation, Operation & Maintenance Manual

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

Temperature Regulators

Instructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)

3820 Pressure Switch-Transmitter

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Integrated temperature test and calibration bench Model CBS-SC4000

Electric Actuator Installation, Operation & Maintenance Manual

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

518A00 MOUNTING INSTRUCTION

WARNING: Only perform this installation if you are experienced, fully equipped mechanic.

IMPORTANT! READ THIS FIRST!

Operating Instructions

TEMPERATURE REGULATORS W91/W94 Series

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

T100A,F,M Controllers

E4-WM5-Y556A00 MOUNTING INSTRUCTION

DODGE USAF 200/300 Direct Mount Pillow Block Bearings

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

Series 500. Liquid Level Transmitters. Instruction Manual

Opposed Piston Differential Pressure Switches

Radiator Kit kw Standby Generator Set

HOLLEY LS-SWAP WATER PUMPS WATER PUMP INSTALLATION INSTRUCTIONS FOR GM LS-ENGINE APPLICATIONS:

COOKSON OWNER'S MANUAL

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

Temperature Sensor Series

WATER PUMP INSTALLATION INSTRUCTIONS WEIAND WATER PUMPS ACTION PLUS & TEAM G APPLICATIONS FOR SMALL BLOCK & BIG BLOCK CHEVROLETS

TWM 7284 & TWM Microswitches equipped Thermostats type :

Operating Instructions

SYSTEM CONTROL KIT. Model: CK-41F ITEMS INCLUDED IN KIT:

1450 Control Valve. General Instructions. Table of Contents

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

Exhaust System Installation for Audi S5, S4, and S6 PNs , ,

GPM Hydraulic Flow Meter User Manual

INSTRUCTION MANUAL TEMPERATURE SWITCHES SERIES TXS,TXN,TXA. WEATHERPROOF (Series TXS) AND FLAMEPROOF (Series TXA, TXN)

Fig. 1 Limits for installation angle

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Installation, Operation, and Maintenance Manual

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

BU01S Bumper. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0

For additional information, please visit our website at SENSOR SPECIFICATIONS

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

YCCS TE-6800 Series Temperature Sensors

Gas Actuated Thermometers

Type 2625 and 2625NS Volume Boosters

IMOI 2010 Rev 0

Installation Instructions and Warranty Information

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

DYNATRAC V6.0. WARNING: Only perform this installation if you are experienced, fully equipped mechanic.

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Pressure Transmitter. Informational & Installation Manual

OFI MODEL 60 ATMOSPHERIC CONSISTOMETER INSTRUCTIONAL MANUAL

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Note: Please read through the entire guide before attempting any kind of installation.

Operating and Maintenance Instructions

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Instruction Bulletin. Jockey Pump Controller

Powers Controls TT 184 Temperature Transmitters

Installation Instructions Mineral Insulated (M.I.)

Long Tube Header Installation PNs , 17276

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Industrial Torque Solutions. Contact:

Advanced Torque Products

Fisher 657 Diaphragm Actuator Sizes and 87

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SynergEX Panelboards for Hazardous Locations

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

Start-up and Operation

Industrial Torque Solutions

Installation & Operation Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MSRT 150. Oil Temperature Indicator for Power Transformer type :

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

Transcription:

The SOR temperature switch utilizes a SAMA Class II thermal system. NOTE: This type of system requires that the entire length of the sensing bulb be exposed to the temperature being measured. Nuclear Qualified Temperature Switches General Instructions Recommended Measurement Procedure In considering the validity of a measurement, remember that temperature-sensing devices respond only to the temperature that they experience. It may be considerably different from the temperature one is attempting to measure if the sensor is of improper size or configuration, or if the sensor is not adequately coupled thermally to the media whose temperature re is being measured. The calibration procedures given below will assure accurate and repeatable measurement of the set points of SOR temperature switches. If the switch is normally mounted in a thermowell, consideration n should be given to the effect this may have on the accuracy acy of the switch. It is recommended that a heat transfer r paste or oil be used to thermally couple the sensing bulb to the thermowell, both in service and during testing. NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative in your area for a return authorization number (RMA). This product should only be installed by trained and competent personnel. Design and specifications are subject to change without notice. For latest revision, go to www.sorinc.com Table of Contents Recommended Measurement Procedure...1 N6 Housing...3 TA Housing...4 RT Housing...5 Installation...6 Site Storage...6 Electrical...6 Calibration...7 Form 655 (04.13) SOR Inc. 1/8

Recommended temperature measurement procedure for switches used to sense temperatures of liquids and steam with set points below 200 F: Use a liquid bath (ethylene glycol, water, oil, etc.) with sufficient circulation to provide a uniform bath temperature and efficient transfer of heat from the liquid to the sensing bulb. Fully submerge the sensing bulb into the bath. Direct-mount sensing bulbs should be submerged up to the bottom of the process connection threads. Locate the tip of the temperature measuring standard (thermocouple, RTD, etc.) at the mid point of, and adjacent to the sensing bulb. Locate the sensing bulb and temperature measuring standard so that they do not touch the sides or bottom of the bath or the heating and cooling coils. When the bath temperature is within 3 F of the set points, it is recommended that the temperature of the bath be changed at a rate of 0.1 F per 5 seconds or slower. The minimum and maximum bath temperatures that the switch sees during testing should be duplicated each time the switch is tested. It is recommended that the temperature of the bath be changed from the normal operating temperature to the critical set point and back to the reset. Do not overshoot the critical set point if the switch is going to be cycled more than once during the test. Recommended temperature measurement procedures for switches used to sense temperatures of liquids and steam with set points above 200 F: Recommended procedures for set points above 200 F are identical to those for set points below 200 F with the exception of the bath used to test the switches. We recommend either a circulated oil bath or a fluidized sand bath. The bath should be tested for uniformity of temperature from top to bottom and side to side. If necessary, steps may be taken to improve the uniformity of temperature, such as altering the air flow through a sand bath or improving circulation or stirring. Recommended temperature measurement procedures for switches used to sense air or gas temperature: Switches used to measure the temperature of air or gas should be tested in such a way that it simulates the actual service conditions as closely as possible. Chances of measurement error are much greater in air because of its poor thermal conductivity. Rate of change of temperature, velocity of air flow, location of sensing bulb, and location of standard must be duplicated as closely as possible for successive calibration checks to assure repeatable results. If the switch is being used as a room thermostat, the entire switch should be placed in a test oven for calibration and testing. If only the sensing bulb is exposed to the air or gas being measured, then only the sensing bulb should be inserted into the oven or test apparatus for calibration and testing. In this case the switch housing should be kept at room temperature. 2/8 Form 655 (04.13) SOR Inc.

N6 Housing Direct Mount Cover Screws 1/8 NPT(F) Body Conduit Mounting Holes Process Sensing Bulb Remote Mount Cover Screws Sensing Bulb 1/8 NPT(F) Process Conduit Mounting Holes Retainer Gland Nut Capillary Mounting Hardware Fasteners per SOR Test Report 9058-102 consist of two 1/4-20, Grade 5 screws (not supplied). Torque screws to 70 to 85 in-lbs. Maintenance Replace cover gasket (SOR P/N 8923-180) whenever cover is removed or minimum of once every 5 years, whichever comes first. Remove the four cover screws. Remove the old gasket. Place new gasket between housing and cover. Line up holes in cover, gasket and housing. Insert the 4 screws and torque each to 7 to 10 in-lbs. Form 655 (04.13) SOR Inc. 3/8

TA Housing Direct Mount Cover U-Bolts 1/4 NPT(F) Body Conduit Process Sensing Bulb Remote Mount Cover U-Bolts Sensing Bulb Process Gland Nut 1/4 NPT(F) Conduit Retainer Capillary Mounting Hardware Fasteners per SOR Test Report 9058-102 consist of three standardgrade 1/4-inch U bolts (not supplied). Maintenance Replace cover o-rings (SOR P/N 8923-206 and 8923-207) whenever cover is removed or minimum of once every 5 years, whichever comes first. Unscrew the cover. Remove the old o-rings. Place new o-rings in grooves of cover. Lubricate o-rings with light film of Krytox 240AC grease (or equivalent fluorinated grease). Tighten cover until the flange of the cover makes contact with the housing. 4/8 Form 655 (04.13) SOR Inc.

RT Housing Direct Mount 1/8 NPT(F) Cover Screws Body Conduit Mounting Holes Process Sensing Bulb Remote Mount Sensing Bulb Cover Screws Conduit 1/8 NPT(F) Process Gland Nut Mounting Holes Retainer Capillary Mounting Hardware Fasteners per SOR Test Report 9058-102 consist of two 1/4-20, Grade 5 screws (not supplied). Torque screws to 70 to 85 in-lbs. Maintenance Replace cover gasket (SOR P/N 8923-181) whenever cover is removed or minimum of once every 5 years, whichever comes first. Remove the four cover screws. Remove old gasket. Place new gasket between housing and cover. Line up holes in cover, gasket and housing. Insert the 4 screws and torque each to 7 to 10 in-lbs. Form 655 (04.13) SOR Inc. 5/8

Installation Refer to applicable drawing for mounting dimensions of specific model number. The vent connection must be plugged or vented to dry atmosphere as required by application requirements. Direct Mount Line mount or mount to a rigid mounting surface with process connection down (6 o clock). If the switch must be removed from a thermowell, loosen the process connection by placing a 1-1/4 wrench on the hex adjacent to the process threads. Do not use wrench on the sensing body. (See drawings.) Remote Mount Mount to a rigid mounting surface with retainer down (6 o clock). Secure capillary every two feet. To install sensing bulb, loosen gland nut so that the process connection turns freely. Re-tighten gland nut after process connection is installed. Site Storage Store switch in a dry area in the original shipping package. Shelf life is 10 years for a maximum ambient temperature of 80 F, based on aging data in SOR Test Report 9058-102. Electrical Electrical connections are marked on the insulation of the wire leads. Conduit should be installed without applying strain to the housing. Temperature Permanent Training Pulling Tension Terminating Junction Temperature Minimum Bend Radius for Wire 1/2 R 1 R 1/4 R 6/8 Form 655 (04.13) SOR Inc.

Calibration To adjust temperature at which switch will operate, remove cover and tighten the hex head adjusting nut with a 3/4-inch wrench to increase temperature; loosen to reduce temperature. Sighting across the top of the 3/4-inch hex adjusting nut to the scale gives approximate set point temperature. Use accurate test gear external to the temperature switch to set or check set points. See recommended measurement procedure on Page 1. After calibration is complete, reinstall the cover with new gaskets or o-rings as required by the maintenance instructions. The switching element has been positioned with a dial indicator to a tolerance of +/-.002 inches. Do not move this switching element! Its position has nothing to do with the set point adjustment. Any movement can either render the switch inoperative or cause the switching element to be damaged with over-temperature. Switching Element Adjusting Nut Calibration Scale Form 655 (04.13) SOR Inc. 7/8

Printed in USA www.sorinc.com 14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 USA Fax 913-888-0767 8/8 Form 655 (04.13) SOR Inc.